Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Portable Performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,405 records · Page 78

Understanding Materials Characteristics of Palladium Lanthanide Cermet Wires as a Mimic of Californium Wire Production

Californium-252 (Cf-252) has been synthesized on a large scale (mg) since the 1970s for use as a portable neutron source. With a half-life of 2.645 years and a spontaneous fission fraction of 3.09%, Cf-252 emits 2.31 × 10 12 neutrons/gram second. Today most of the Cf-252 produced in the world is made at Oak Ridge National Laboratory (ORNL) using the High Flux Isotope Reactor (HFIR) and the Radiochemical Engineering Development Center (REDC). Because of its highly radioactive nature, all manipulations of Cf-252 need to be performed in hot cell facilities by highly trained personnel. The Cf-252 produced at ORNL is done at the REDC, which is conveniently located next to the HFIR. Cf-252 is sold as bulk wire, which has been described as palladium (Pd) metal incasing californium oxide (Cf 2 O 3 ). The process was developed by Mosley et al. at Savannah River Laboratory (SRL) where it was modeled after the thorium work done by Fuschillo et al. This process has been used since the 1970s to synthesize this unique wire, but its fundamental chemistry and materials characteristics were never openly reported. Here we aim to better understand the chemistry and the materials characteristics of Cf-252 wire production for process improvements and to better our fundamental understanding of the mid-late actinides. Though there are many challenges in working with radioactive elements such as Cf, the isotope Cf-252 is even more complicated due to its neutron emission. One challenge with neutron emission is the ability of neutrons to penetrate much deeper through materials, causing radiation damage. This makes using instrumentation to characterize the chemistry and materials properties of this process difficult. For this reason, this study will first focus on terbium (Tb) as a surrogate for Cf. Currently Tb is used as a carrier or filler in Cf production when small amounts of Cf are being processed. This, along with their similar size and charge, makes Tb a reasonable surrogate for this study.

36 MATERIALS SCIENCE↗

Fault Injection for TensorFlow Applications

As machine learning (ML) has seen increasing adoption in safety-critical domains (e.g., autonomous vehicles), the reliability of ML systems has also grown in importance. While prior studies have proposed techniques to enable efficient error-resilience (e.g., selective instruction duplication), a fundamental requirement for realizing these techniques is a detailed understanding of the application’s resilience. In this work, we present TensorFI 1 and TensorFI 2, high-level fault injection (FI) frameworks for TensorFlow-based applications. TensorFI 1 and 2 are able to inject both hardware and software faults in any general TensorFlow 1 and 2 program respectively. Both are configurable FI tools that are flexible, easy to use, and portable. They can be integrated into existing TensorFlow programs to assess their resilience for different fault types (e.g., bit-flips in particular operations or layers). We use the TensorFI 1 and TensorFI 2 to evaluate the resilience of 12 and 10 ML programs written in TensorFlow, including DNNs used in the autonomous vehicle domain. The results give us insights into why some of the models are more resilient. We also measure the performance overheads of the two injectors, and present 4 case studies, two for each tool, to demonstrate their utility.

97 MATHEMATICS AND COMPUTING↗

Fifty years of lithium-ion batteries and what is next?

Here, the first rechargeable lithium batteries were built 50 years ago, at the same time as the Materials Research Society was formed. Great strides have been made since then taking a dream to domination of portable energy storage. During the past two decades, the demand for the storage of electrical energy has mushroomed both for portable applications such as for the iPhone and electric vehicles and for more than 1 GWh grid applications. As storage and power demands have increased, the batteries have evolved with their chemistries being pushed to the limits. This has resulted in the energy densities almost doubling and the cost dropping by more than an order of magnitude. However, the present electrochemical systems are still too costly to penetrate major new markets, still higher performance is required, and environmentally acceptable and sustainable materials are required.

25 ENERGY STORAGE↗

Development and testing of a portable wind sensitive directional air sampler

A portable wind-sensitive directional air sampler has been developed as part of an air pollution source identification system. The system is designed to identify sources of air pollution based on the directional collection of field air samples and their analysis for TSP and trace element characteristics. Sources can be identified by analyzing the data on the basis of pattern recognition concepts. Functional testing of a prototype sampler is described; all items exhibited performance and life sufficient to carry out field performance test operations. Life testing of the wind direction sensor and the directional porting valves, which are critical to reliable operation, was emphasized with successful results.

Deyo, J.↗

High Performance FORTRAN

High performance FORTRAN is a set of extensions for FORTRAN 90 designed to allow specification of data parallel algorithms. The programmer annotates the program with distribution directives to specify the desired layout of data. The underlying programming model provides a global name space and a single thread of control. Explicitly parallel constructs allow the expression of fairly controlled forms of parallelism in particular data parallelism. Thus the code is specified in a high level portable manner with no explicit tasking or communication statements. The goal is to allow architecture specific compilers to generate efficient code for a wide variety of architectures including SIMD, MIMD shared and distributed memory machines.

Mehrotra, Piyush↗

Motor and cognitive testing of bone marrow transplant patients after chemoradiotherapy

Assessment of cognitive and motor performance of bone marrow transplant patients prior to, during, and following intensive toxic chemoradiotherapy may provide an important adjunct to measures of physiological and medical status. The present study is an attempt to assess whether, as side-effects, these aggressive treatments result in cognitive performance deficits, and if so, whether such changes recover posttreatment. Measurement of cognitive ability in this situation presents special problems not encountered with one-time tests intended for healthy adults. Such tests must be sensitive to changes within a single individual, which emphasizes the crucial importance of high reliability, stability across repeated-measures, and resistance to confounding factors such as motivation and fatigue. The present research makes use of a microbased portable test battery developed to have reliable and sensitive tests which were adapted to study the special requirements of transplant patients who may suffer cognitive deficits as a result of treatment. The results showed slight but significant changes in neuropsychological capacity when compared to baseline levels and controls, particularly near the beginning of treatment. The sensitivity of the battery in detecting such subtle temporary changes is discussed in terms of past research showing effects of other stressors, such as stimulated high altitude and ingestion of alcohol, on these measures.

Non-NASA Center↗

Endosafe(R)-Portable Test System (PTS)

The Portable Test System (PTS) is a hand-held device for monitoring the presence of potentially hazardous bacteria in the environment. It uses an immunological method derived from the horseshoe crab (Limulus polyphemus) to detect bacterial cell membranes and other molecular components of a cell. Further modifications of the PTS will allow detection of individual hazardous species of bacteria. This study was a follow-up of previous PTS and other immunological tests performed on the KC-135 during 2002-2003 (Maule et al., 2003, J. Gravit. Physiol.) and in the underwater habitat Aquarius during NEEMO 5 (Maule et al., 2005, Appl. Environ. Microbiol in prep.). The experiments described here were part of a final testing phase prior to use of the PTS on the International Space Station (ISS), scheduled for launch on 12A.1 on February 9th 2006. The specific aspects of PTS operation studied were those involving a fluid component: pumping, mixing, incubations and pipetting into the instrument. The PTS uses a stepper motor to move fluid along small channels, which may be affected by reduced gravity.

Maule, Jake↗

Small Aircraft RF Interference Path Loss Measurements

Interference to aircraft radio receivers is an increasing concern as more portable electronic devices are allowed onboard. Interference signals are attenuated as they propagate from inside the cabin to aircraft radio antennas mounted on the outside of the aircraft. The attenuation level is referred to as the interference path loss (IPL) value. Significant published IPL data exists for transport and regional category airplanes. This report fills a void by providing data for small business/corporate and general aviation aircraft. In this effort, IPL measurements are performed on ten small aircraft of different designs and manufacturers. Multiple radio systems are addressed. Along with the typical worst-case coupling values, statistical distributions are also reported that could lead to more meaningful interference risk assessment.

Nguyen, Truong X.↗

Small Aircraft RF Interference Path Loss

Interference to aircraft radio receivers is an increasing concern as more portable electronic devices are allowed onboard. Interference signals are attenuated as they propagate from inside the cabin to aircraft radio antennas mounted on the outside of the aircraft. The attenuation level is referred to as the interference path loss (IPL) value. Significant published IPL data exists for transport and regional category airplanes. This report fills a void by providing data for small business/corporate and general aviation aircraft. In this effort, IPL measurements are performed on ten small aircraft of different designs and manufacturers. Multiple radio systems are addressed. Along with the typical worst-case coupling values, statistical distributions are also reported that could lead to better interference risk assessment.

Nguyen, Truong X.↗

PLSS 2.5 Fan Design and Development

NASA is building a high fidelity prototype of an advanced portable life support system (PLSS) as part of the Advanced Exploration Systems Program. This new PLSS, designated as PLSS 2.5, will advance component technologies and systems knowledge in order to inform a future flight program. The oxygen ventilation loop of its predecessor, PLSS 2.0, is driven by a centrifugal fan developed using specifications from the Constellation Program. PLSS technology and system parameters have matured to the point where the existing fan will not perform adequately for the new prototype. In addition, areas of potential improvement have been identified with the existing fan that could be addressed in a new design. As a result, a new fan was designed and tested for the PLSS 2.5.

Quinn, Gregory↗

Utilizing a Suited Manikin Test Apparatus and Space Suit Ventilation Loop to Evaluate Carbon Dioxide Washout

NASA is pursuing technology development of an Advanced Extravehicular Mobility Unit (AEMU) which is an integrated assembly made up of primarily a pressure garment system and a portable life support subsystem (PLSS). The PLSS is further composed of an oxygen subsystem, a ventilation subsystem, and a thermal subsystem. One of the key functions of the ventilation system is to remove and control the carbon dioxide (CO2) delivered to the crewmember. Carbon dioxide washout is the mechanism by which CO2 levels are controlled within the space suit helmet to limit the concentration of CO2 inhaled by the crew member. CO2 washout performance is a critical parameter needed to ensure proper and robust designs that are insensitive to human variabilities in a space suit. A suited manikin test apparatus (SMTA) was developed to augment testing of the PLSS ventilation loop in order to provide a lower cost and more controlled alternative to human testing. The CO2 removal function is performed by the regenerative Rapid Cycle Amine (RCA) within the PLSS ventilation loop and its performance is evaluated within the integrated SMTA and Ventilation Loop test system. This paper will provide a detailed description of the schematics, test configurations, and hardware components of this integrated system. Results and analysis of testing performed with this integrated system will be presented within this paper.

Chullen, Cinda↗

A portable fiber optic sensor for the luminescent sensing of cobalt ions using carbon dots

Cobalt is critical to energy-relevant technologies, and demand for cobalt will increase significantly with growing global adoption of renewables. However, supply chain stability is threatened by economic and geopolitical factors, incentivizing domestic cobalt production from alternative resources such as coal, coal utilization byproducts (e.g., ash, acid mine drainage) and electronic waste. Rapid, inexpensive, and portable characterization techniques are needed to reduce production costs associated with cobalt prospecting and process monitoring. Here, in this research, we develop a compact, portable fiber optic luminescent probe for cobalt using phosphorus and nitrogen co-doped carbon dots as the sensing material. The carbon dot emission overlaps well with the cobalt absorption band at ~510 nm, leading to a selective decrease in emission as a function of cobalt concentration. The system responds nearly instantly to the presence of cobalt, with detection limits of 0.7 and 3.5 ppm in water and pH 1.68 buffer, respectively, providing comparable performance to a commercial spectrometer at a significantly lower cost. Moreover, the sensor is selective for cobalt in the presence of 13 of the most common metal ions encountered in coal utilization byproducts and is responsive to cobalt when spiked into an acid mine drainage leachate sample, highlighting the sensor's potential for real-world deployment in challenging matrices. In addition, integrating the carbon dots with a filter paper substrate produced ‘test strip’ sensors that exhibited a selective and sensitive visual response to cobalt using a handheld UV lamp. Taken together, the sensing system represents a significant step forward in the development of low-cost practical sensors for high-value metals in complex streams.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A Survey on the Expanding Scope and Interdisciplinary Opportunities for Processing-in-Memory Techniques

Processing-in-Memory (PIM) is emerging as a practical path to overcome the limitations of traditional von Neumann architectures. At its core, PIM systems implement computing primitives such as logic operations and multiply-accumulate acceleration through compute-in-memory, near-memory processing, or hybrid designs. The role of memory cells varies widely across technologies, acting as inputs, outputs, or analog accumulators through bit-lines and sense amplifiers. This diversity creates trade-offs in precision, bandwidth, latency, and programmability, making it difficult to build a unified understanding on the progress of the field. In this survey, we organize recent advances of PIM into three areas. First, we discuss the progress on the architectural optimizations of PIM and its integration with both DRAM and emerging non-volatile memories. Second, we examine how PIM is being used to accelerate key computing domains, including generative AI workloads and high-performance kernels, along with new approaches. Third, we highlight the growing adoption of PIM in computational sciences, where it is being applied to solve interdisciplinary problems such as genome analysis, mRNA quantification, mass spectrometry, quantum circuit simulation, wave modeling, and secure computation. Finally, we synthesize the major challenges that continue to slow PIM adoption, including manufacturing constraints, power delivery, thermal reliability, data consistency, runtime and memory-management coordination, and the difficulty of building portable software abstractions without sacrificing commercial viability. This work provides an updated, structured perspective on PIM’s potential across computing and computational sciences and the barriers that must be solved for it to reach its full impact.

Asifuzzaman, Kazi [Oak Ridge National Laboratory (↗

A market survey of geothermal wellhead power generation systems

The market potential for a portable geothermal wellhead power conversion device is assessed. Major study objectives included identifying the most promising applications for such a system, the potential impediments confronting their industrialization, and the various government actions needed to overcome these impediments. The heart of the study was a series of structured interviews with key decision-making individual in the various disciplines of the geothermal community. In addition, some technical and economic analyses of a candidate system were performed to support the feasibility of the basic concept.

Leeds, M. W.↗

Ultra Small Aperture Terminal: System Design and Test Results

The Ultra Small Aperture Terminal (USAT) has been developed to test and demonstrate remote and broadcast satcom applications via the Advanced Communications Technology Satellite (ACTS). The design of these ground stations emphasize small size, low power consumption, portable and rugged terminals. Each ground station includes several custom design parts such as 35 cm diameter antenna, 1/4 Watt transmitter with built-in upconverter, and 4.0 dB Noise Figure (NF) receiver with built-in downconverter. In addition, state-of-the-art commercial parts such as highly stable ovenized crystal oscillators and dielectric resonator oscillators are used in the ground station design. Presented in this paper are system level design description, performance, and sample applications.

Sohn, Philip Y.↗

PLSS 2.5 Fan Design and Development

NASA is building a high fidelity prototype of an advanced portable life support system (PLSS) as part of the Advanced Exploration Systems Program. This new PLSS, designated as PLSS 2.5, will advance component technologies and systems knowledge in order to inform a future flight program. The oxygen ventilation loop of its predecessor, PLSS 2.0, is driven by a centrifugal fan developed using specifications from over five years ago. PLSS technology and system parameters have matured to the point where the existing fan will not perform adequately for the new prototype. In addition, areas of potential improvement have been identified with the existing fan that could be addressed in a new design. As a result, a new fan was designed and tested for the PLSS 2.5. The PLSS 2.5 fan is a derivative of the one used in PLSS 2.0. It uses the same basic non-metallic can around the motor, but with a larger volute and impeller to meet the higher pressure drop requirements of the PLSS 2.5 loop. This allows it to operate at rotational speeds that are matched to rolling element bearings, and which create reasonably low impeller tip speeds. Development of the fan also considered a shrouded impeller design that allows larger clearances for greater oxygen safety and better performance.

Converse, David↗

Evaluating Sensory Augmentation as A Non-Pharmaceutical Tool to Mitigate Motion Sickness and Enhance Sensorimotor Task Performance: A Pilot Study Using Simulated Capsule Wave Motion

Wave motion during capsule recovery operations can result in motion sickness and performance decrements exacerbating reentry sickness following long duration spaceflight. The purpose of this pilot study was (1) to validate a capsule wave motion simulation as a platform to evaluate motion sickness countermeasures and (2) to evaluate a sensory augmentation belt providing vibrotactile feedback of gravitational upright. Ten healthy subjects ages 38.0 ± 10.1 (6M|4F) were exposed to complex wave motions on a six degree-of-freedom platform that included pitch, roll, and heave at provocative stimulus frequencies (0.1-0.25 Hz) while seated in an illuminated cabin deprived of external visual cues. Subjects reported acute symptoms for up to three consecutive 15 min trials or until they reached a motion sickness endpoint of 8 pts on the Pensacola Diagnostic Index (PDI). Five subjects were randomly assigned to the Sensory Augmentation (SA) group while the other five served as controls (CN group). Based on a Motion Sickness Susceptibility Questionnaire, the two groups had similar motion sickness histories (susceptibility percentile ranking of CN group = 27.5 ± 63.6 in the CN group versus 27.5 ± 37.0 in the SA group, median ± IQR). The vibrotactile feedback consisted of a single array of 8 electromechanical tactors positioned around the torso on an adjustable belt (Engineering Acoustics, Inc) that utilized an integrated inertial measurement unit (IMU) to indicate the direction of upright (e.g., subject’s back tactor on during forward tilt). During each wave motion trial subjects performed a battery of four different tasks: tracking Earth vertical using a joystick with and without a secondary task (Paced Auditory Serial Addition Test), an eye-hand target acquisition task on a cabin-fixed tablet, and the psychomotor vigilance test (PVT). All ten subjects reported varying levels of motion sickness with 6 of 10 reaching a symptom endpoint. Interestingly, subjects anecdotally reported that engagement in the joystick tracking task was less provocative than tasks involving the cabin-fixed tablet or periods of no activity. Sensory augmentation appeared to delay symptom onset, with 2 of 5 subjects reaching an endpoint within the first 15 min trial in the CN group versus none in the SA group (PDI after 15 min = 6.0 ± 2.5 in the CN group versus 3.4 ± 2.5 in the SA group, mean ±std). Sensory augmentation also improved performance on the joystick tracking task at lower stimulus frequencies (0.1 Hz in roll and 0.2 Hz in pitch). Both CN and SA groups maintained a consistent level of performance on the eye-hand target acquisition and PVT throughout the baseline (no motion) and wave motion periods. Our results validated that the simulated capsule wave motion paradigm provides an effective motion sickness stressor. This paradigm is currently being used to investigate the efficacy of intranasal scopolamine to mitigate motion sickness. Sensory augmentation using vibrotactile feedback appears to improve spatial awareness and delay symptom onset during complex passive motion. One advantage of this portable belt design is that it incorporates all tactor drive and IMU circuitry and therefore could continue to be worn by crewmembers and serve as a balance aid during egress and ambulation with recovery operations.

A M Bollinger↗

Comparison of Physical Workload Across Eva-Simulation Analog Environments: Hybrid Space Suit Simulator and Pressurized Suit Testing

NASA conducts research, testing, and training across a variety of analog environments to support characterization of human performance during Extravehicular Activities (EVAs). Time utilizing pressurized suits in an offloaded environment is both limited and expensive, making it challenging to carry out extensive research with these suits. The Human Physiology, Performance, Protection, and Operations (H-3PO) Laboratory at NASA Johnson Space Center designed a Hybrid Space Suit Simulator (HS3) as a low-cost, workload approximator and easy access research tool to provide relevant physical and cognitive workloads during simulated EVAs. A pilot study was conducted in a 1g analog environment where six healthy subjects (3 male, 3 female) underwent simulated 5-hour EVAs in the HS3. This study used a COSMED K5 portable metabolic analyzer and a Polar H10 heart rate monitor to evaluate physical workload during the EVAs. For direct comparison, EVA tasks and timelines were modeled after a similar study conducted in pressurized suits (Mark-III spacesuit, n=3 male; small xPGS spacesuit, n=3 female) at NASA’s Active Response Gravity Offload System (ARGOS) offloaded to Lunar gravity (1/6 g). The 1g HS3 data demonstrated increased metabolic rate when compared to pressurized, Lunar-offloaded suited simulated EVAs for certain tasks including the kneeling scoop (HS3: 1194±199 BTU/hr, ARGOS: 860±170 BTU/hr, p < 0.05) and 20 lb object relocation (HS3: 1651±136 BTU/hr, ARGOS: 1048±252.8 BTU/hr, p < 0.05), but it did not demonstrate any significant differences in heart rate (p > 0.05). Other simulated EVA tasks, such as a 500 m traverse (HS3: 1431±177 BTU/hr, ARGOS: 1212±294 BTU/hr, p > 0.05), showed similar workload profiles with no significant workload differences between HS3 and ARGOS. The HS3 is a useful research tool for increasing workloads in EVA research without pressurized suits, though it may overestimate workload during certain EVA tasks when used in 1g environments.

Zachary Wusk↗