At least 1,405 records · Page 78

Putting Data to Work: Using Building Energy Performance Data to Expand the Market for Energy Efficiency in Buildings

An increasing number of state and local jurisdictions are implementing building performance reporting laws, which generate large quantities of useful data on the characteristics and resource consumption of the building stock. Yet, to realize the potential of these policies, the data must not only be disclosed, but put to work to drive energy savings. Under a three-year pilot, Washington DC (DC), New York City (NYC) and their partners are pioneering the use of data from building performance reporting in energy efficiency programs. To minimize the administrative burden of managing, combining, and sharing these data sets, the cities are utilizing the U.S. Department of Energy’s (DOE) open-source Standard Energy Efficiency Data (SEED) Platform. The Putting Data to Work project team is working with efficiency program administrators to develop and implement new and innovative ways in which the data collected through benchmarking, energy audits, and related policies can be used to improve energy policies and planning, unlock data directly for market use, scale-up the market for energy efficiency services, drive competition, better target utility incentive programs, and inform measurement and verification. This paper details achievements and key findings in DC and NYC to date, including the importance of high compliance, data quality, and data cleansing in using the information collected; methods that the cities are using to apply data to drive maximum energy efficiency; and the importance of inter- and intra-agency collaboration in program success. We also outline the path forward and detail expected outcomes and scalability of project activities.

Beddingfield, Erin↗

Energy Savings Modeling and Inspection Guidelines for Commercial Building Federal Tax Deductions for Buildings in 2016 and Later

This document provides guidance for modeling and inspecting energy-efficient property in commercial buildings for certification of the energy and power cost savings related to Section 179D of the Internal Revenue Code (IRC) enacted in Section 1331 of the 2005 Energy Policy Act (EPAct) of 2005, noted in Internal Revenue Service (IRS) Notices 2006-52 (IRS 2006), 2008-40 (IRS 2008) and 2012-26 (IRS 2012), and updated by the Protecting Americans from Tax Hikes (PATH) Act of 2015. Specifically, Section 179D provides federal tax deductions for energy-efficient property related to a commercial building's envelope; interior lighting; heating, ventilating, and air conditioning (HVAC); and service hot water (SHW) systems. This document applies to buildings placed in service on or after January 1, 2016.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Strengthening Retrofit Markets for Comprehensive Savings in Multifamily Buildings (Interim Final Report)

Energy efficiency is vitally important in Maine. Nearly 70% of Maine households rely on fuel oil as their primary energy source for home heating, a higher share than in any other state. Coupled with the state's long, cold winters, Maine's dependence on oil renders homeowners particularly vulnerable to fluctuating fuel costs. With $\$$4.5 million in seed funding from the Energy Department's Better Buildings Neighborhood Program, the Governor's Energy Office (GEO), through Efficiency Maine Trust (the Trust), is spurring Maine landlords to lower their monthly energy bills and improve comfort for their tenants during the state's cold winter months and increasingly warmer summers. Maine's aging multifamily housing stock can be expensive to heat and costly to maintain. It is not unusual to find buildings with little or no insulation, drafty windows, and significant air leaks, making them ideal candidates for energy efficiency upgrades. Maine modeled its Multifamily Efficiency Program (MEP) after the state's highly successful Home Energy Savings Program (HESP) for single-family homes. HESP provided cash incentives and financing opportunities to owners of one-to four-unit structures, which resulted in thousands of energy assessments and whole-house energy upgrades in 225 communities. Maine's new MEP multifamily energy efficiency upgrade and weatherization initiative focuses on small to medium-sized (i.e., five to 20 units) apartment buildings. The program's energy efficiency upgrades will provide at least 20% energy savings for each upgraded multifamily unit. The Trust’s MEP relies on a network of approved program partners who help move projects through the pipeline from assessment to upgrade. MEP has two components: benchmarking and development of an Energy Reduction Plan (ERP). Using the ENERGY STAR® Portfolio Manager benchmarking tool, MEP provides an assessment of current energy usage in the building, establishes a baseline for future energy efficiency improvements, and enables tracking and monitoring of future energy usage at the building— all at no cost to the building owner. The ERP is developed by a program partner using either the Trust’s approved modeling or prescriptive tools; it provides detailed information about the current energy related conditions in the building and recommends energy efficiency, health, and safety improvements. The Trust's delivery contractor provides quality assurance and controls throughout the process. Through this effort, MEP's goal is to establish a self-sustaining, market-driven program, demonstrating the value of energy efficiency to other building owners. The increasing value of properties across the state will help incentivize these owners to continue upgrades after the grant period has ended. Targeting urban areas in Maine with dense clusters of multifamily units—such as Portland, Lewiston- Auburn, Bangor, and Augusta—MEP engaged a variety of stakeholder groups early on to design its multifamily program. Through direct emails and its website, program officials invited lending institutions, building professionals, engineering firms, equipment distributors, and local property owners associations to attend open meetings around the state to learn about the goals of the multifamily program and to help define its parameters. These meetings helped program administrators understand the diversity of the customer base: some owners are individuals with a single building, while other owners are groups of people or management companies with an entire portfolio of multifamily buildings. The diversity of the customer base notwithstanding, owners see MEP as an opportunity to make gains in their respective properties. Consistently high turnouts at stakeholder meetings fueled greater customer interest as awareness of the program spread through word of mouth. The program also gained traction by utilizing the program partner networks and building on the legacy of the Trust’s successful HESP for single-family residences. MEP offers significant incentives for building owners to participate in the upgrade program. Wholebuilding benchmarking services are available to most multifamily housing buildings free of charge. The service provides the building owner with an assessment of the building's current energy efficiency as compared to other multifamily buildings on a national scale, establishes a baseline to measure future improvements, and enables owners to track monthly energy consumption using the ENERGY STAR Portfolio Manager. Once the benchmarking process is complete, the program links building owners with approved program partners (e.g., energy professionals, home performance contractors) to identify and implement specific energy-saving opportunities in the building. Program partners can also provide project quotes with estimated financing incentives and payback period calculations that enable building owners to make informed decisions. What's more, the Trust provides two financial incentives for successful completion of program milestones. The first is a per-unit incentive for completion of an approved ERP (i.e., $\$$100 per unit if a prescriptive path is followed, and $\$$200 per unit for a modeled ERP). Upon final inspection of the installed project scope of work, an incentive of $\$$1,400 per unit or 50% of installed cost—whichever is less—is paid. The Trust originally established a $\$$1 million loan-loss reserve fund (LLRF) to further enhance financing opportunities for qualified multifamily building owners. This funding mechanism was designed to connect building owners with lenders that retain the mortgages for their properties and encourages the lenders to offer financing for energy efficiency improvements. However, there has been no interest in the LLRF and therefore the LLRF has been reduced. Ultimately, MEP plans to build an online tool for building owners to assess opportunities to make upgrades in their multifamily units. The tool will include a performance rating system to provide a way for building owners to more easily understand energy use in their building, and how it could be improved with energy efficiency upgrades. Prospective tenants will also be able to use the rating system to make informed decisions about where to rent. Furthermore, the rating can be incorporated into real estate listings as a way for prospective home buyers and the real estate financial community to evaluate a home's operating costs. The Trust’s MEP has identified the state's most experienced energy professionals, vendors, suppliers, and contractors that install energy efficiency equipment in the multifamily sector to be qualified program partners. To be eligible for partnership, energy assessment professionals and contractors are required to have demonstrated experience in the multifamily sector and hold associated professional certifications, such as Building Operator Certification (BOC), Certified Energy Manager (CEM), Professional Engineer (PE), or Building Performance Institute (BPI) Multifamily Building Analyst. Widespread program interest has enabled the Trust to redirect funds that might otherwise be needed for program promotion to building capacity through contractor training. In addition to boosting professional training and certification opportunities, MEP teaches its partners how to market the multifamily program to prospective multifamily homeowners.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Path to Subsurface Closure: When Real and Predicted Data Don't Match, Central Nevada Test Area (CNTA) - 19560

The Central Nevada Test Area, Nevada, was the site of an underground nuclear test in 1968, which resulted in residual contamination at and near the detonation depth of 975 meters (3200 feet). The environmental corrective action strategy for the site was conducted in accordance with the Federal Facility Agreement and Consent Order and all applicable Nevada Division of Environmental Protection (NDEP) policies and regulations. The corrective action strategy initiated in 1999 included developing a conceptual site model, preparing a numerical flow and transport model, calculating contaminant boundaries, negotiating compliance boundaries with NDEP, performing model validation, and monitoring groundwater. This strategy was executed through the Corrective Action Decision Document/Corrective Action Plan phase, when it was determined that the flow and transport model could not be validated because it failed to adequately predict groundwater elevations in the monitoring/validation (MV) wells (MV-1, MV-2, and MV-3) drilled subsequent to the modeling effort. This led to a change in the corrective action strategy that is now designed to validate the compliance boundary through monitoring and institutional controls, rather than relying predominantly on a numerical flow and transport model. This new approach included enhancements to the monitoring well network and additional monitoring to confirm that data were sufficient to proceed to closure. The corrective action activities were completed in 2015, and the Closure Report, which established the long-term postclosure monitoring program, was approved in 2016. The postclosure monitoring program is designed to (1) assess the effectiveness of the compliance boundary by monitoring for the radionuclides of interest and (2) evaluate the effectiveness of monitoring locations within the groundwater flow system by monitoring water elevations to ensure that monitoring wells are located along the potential migration pathways. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Systemwide Planning with a Branch-and-Price Algorithm for Pavement-Marking Assessment Data Collection via the Mobile Retroreflectivity Unit Routing Model

The visibility of pavement markings is one of the most critical factors for traffic safety, and a periodical assessment plan is crucial for maintaining this function. Traditional assessment methods, such as visual windshield surveys or manual testing using handheld devices, are unsafe, time-consuming, and labor-intensive. In recent years, transportation agencies have begun to adopt the use of mobile retroreflectivity units (MRUs) for condition assessment of pavement markings. MRUs, different from other manual methods, can be utilized to collect large-scale retroreflectivity data in an efficient manner. However, no relevant research has yet proposed a mathematical optimization model for arranging the evaluation schedule and paths of MRUs. This study aims to propose a MRU routing model, and an efficient solution methodology. A branch-and-price algorithm, including column generation and branch-and-bound, was implemented. Computational experiments have been conducted based on actual tasks from the Florida MRU program for validation. In conclusion, results show that the proposed solution methodology with a set partitioning model in this study not only finds the optimal solution for problems with tasks less than 60, but also effectively narrows the solution gap to be within 1.0% for problems with tasks less than 131.

42 ENGINEERING↗

Securing Future Energy Supplies: From Renewables to Microreactors

This session will provide insight into how future energy deployments, critical to national-level programs focused on reducing carbon emissions, can be secured-by-design using lessons learned from current energy infrastructure. It will begin with an overview of current threats and risks associated with renewable energy assets and systems, primarily wind and solar, focusing on their control architecture and key system functions for both efficient and safe operations. This talk will then translate the key takeaways from current renewable infrastructure into applications for securing future energy systems, including microreactors and small modular reactors (SMRs), based on planned concepts of operations and control. Microreactors and SMRs are intended to be factory-assembled with commercially available components and deployed in more remote or distributed environments, necessitating centralized control centers, remote monitoring, and offsite maintenance and technical support. All of these factors lead these assets to a security posture and controls more similar to today's renewable energy assets than today's nuclear reactors, which represents a significant shift in mindset for the nuclear industry. This talk will provide justification for this shift as well as a path forward to motivate securing these groundbreaking technologies from the outset of their design and deployment.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Miniature Piezoelectric Shaker for Distribution of Unconsolidated Samples to Instrument Cells

The planned Mars Science Laboratory mission requires inlet funnels for channeling unconsolidated powdered samples from the sampling and sieving mechanisms into instrument test cells, which are required to reduce cross-contamination of the samples and to minimize residue left in the funnels after each sample transport. To these ends, a solid-state shaking mechanism has been created that requires low power and is lightweight, but is sturdy enough to survive launch vibration. The funnel mechanism is driven by asymmetrically mounted, piezoelectric flexure actuators that are out of the load path so that they do not support the funnel mass. Each actuator is a titanium, flextensional piezoelectric device driven by a piezoelectric stack. The stack has Invar endcaps with a half-spherical recess. The Invar is used to counteract the change in stress as the actuators are cooled to Mars ambient temperatures. A ball screw is threaded through the actuator frame into the recess to apply pre-stress, and to trap the piezoelectric stack and endcaps in flexure. During the vibration cycle of the flextensional actuator frame, the compression in the piezoelectric stack may decrease to the point that it is unstressed; however, because the ball joint cannot pull, tension in the piezoelectric stack cannot be produced. The actuators are offset at 120 . In this flight design, redundancy is required, so three actuators are used though only one is needed to assist in the movement. The funnel is supported at three contact points offset to the hexapod support contacts. The actuator surface that does not contact the ring is free to expand. Two other configurations can be used to mechanically tune the vibration. The free end can be designed to drive a fixed mass, or can be used to drive a free mass to excite impacts (see figure). Tests on this funnel mechanism show a high density of resonance modes between 1 and 20 kHz. A subset of these between 9 and 12 kHz was used to drive the CheMin actuators at 7 V peak to peak. These actuators could be driven by a single resonance, or swept through a frequency range to decrease the possibility that a portion of the funnel surface was not coincident with a nodal line (line of no displacement). The frequency of actuation can be electrically controlled and monitored and can also be mechanically tuned by the addition of tuning mass on the free end of the actuator. The devices are solid-state and can be designed with no macroscopically moving parts. This design has been tested in a vacuum at both Mars and Earth ambient temperatures ranging from 30 to 25 C

Sherrit, Stewart↗

Computing Proximity to Threat Along Uncertain Trajectory to Support Urban Air Mobility

Many airspace threats affect the selection of a flight route, such as terrain, physical obstacles, adverse weather, and special-use airspace, among others. Threat avoidance during Urban Air Mobility (UAM) and Low Altitude Mobility (LAM) flights is especially challenging due to their lower cruising altitudes. These operations may be exposed to buildings, towers, trees, terrain undulations, etc., along much of their flight route. Moreover, these low-altitude flights in urban environments are expected to encounter very busy airspace, increasing the workload associated with threat avoidance. The Proximity to Threat (PtT) function aims to support onboard or remote pilots by computing the risk from geospatial threats in the airspace along an aircraft’s flight path. The threats are both static entities and dynamic airspace restrictions that have been modeled and stored in geo-referenced mapping databases. The flight path may be specified by waypoints, airways, or similar discrete route elements or by a time series of closely spaced position and altitude points. Flight path uncertainty can also be taken into account by assuming both the position and altitude to be sampled from two normal distributions, each being specified by a mean and variance. PtT uses this additional information to verify that the flight path remains clear of threats along a wider path or if a position is reached earlier or later than anticipated, assuring the pilot or operator that there will be an available safety margin even if the aircraft deviates due to one or more occurrences of unexpected wind gusts, mechanical failures, airspeed changes, collision avoidance maneuvers, etc. The client can specify an uncertainty confidence level to bound the set of trajectories evaluated for threats so that the confidence level corresponds to the client’s risk tolerance under the expected conditions. PtT can be used as a pre-flight planning tool to determine a safe route through known threats and in-flight to avoid emerging or changing threats. In this report, we present the PtT function, discuss how the trajectory uncertainty is incorporated into the PtT function, and describe the use of this PtT function in a representative scenario.

urban air mobility↗

Statistical Methodologies to Integrate Experimental and Computational Research

Development of advanced algorithms for simulating engine flow paths requires the integration of fundamental experiments with the validation of enhanced mathematical models. In this paper, we provide an overview of statistical methods to strategically and efficiently conduct experiments and computational model refinement. Moreover, the integration of experimental and computational research efforts is emphasized. With a statistical engineering perspective, scientific and engineering expertise is combined with statistical sciences to gain deeper insights into experimental phenomenon and code development performance; supporting the overall research objectives. The particular statistical methods discussed are design of experiments, response surface methodology, and uncertainty analysis and planning. Their application is illustrated with a coaxial free jet experiment and a turbulence model refinement investigation. Our goal is to provide an overview, focusing on concepts rather than practice, to demonstrate the benefits of using statistical methods in research and development, thereby encouraging their broader and more systematic application.

Parker, P. A.↗

Development of an Integrated Waste Plan for Chalk River Laboratories - 13376

To further its Strategic Planning, the Atomic Energy of Canada Limited (AECL) required an effective approach to developing a fully integrated waste plan for its Chalk River Laboratories (CRL) site. Production of the first Integrated Waste Plan (IWP) for Chalk River was a substantial task involving representatives from each of the major internal stakeholders. Since then, a second revision has been produced and a third is underway. The IWP remains an Interim IWP until all gaps have been resolved and all pathways are at an acceptable level of detail. Full completion will involve a number of iterations, typically annually for up to six years. The end result of completing this process is a comprehensive document and supporting information that includes: - An Integrated Waste Plan document summarizing the entire waste management picture in one place; - Details of all the wastes required to be managed, including volume and timings by waste stream; - Detailed waste stream pathway maps for the whole life-cycle for each waste stream to be managed from pre-generation planning through to final disposition; and - Critical decision points, i.e. decisions that need to be made and timings by when they need to be made. A waste inventory has been constructed that serves as the master reference inventory of all waste that has been or is committed to be managed at CRL. In the past, only the waste that is in storage has been effectively captured, and future predictions of wastes requiring to be managed were not available in one place. The IWP has also provided a detailed baseline plan at the current level of refinement. Waste flow maps for all identified waste streams, for the full waste life cycle complete to disposition have been constructed. The maps identify areas requiring further development, and show the complexities and inter-relationships between waste streams. Knowledge of these inter-dependencies is necessary in order to perform effective options studies for enabling facilities that may be necessary for multiple related waste streams. The next step is to engage external stakeholders in the optioneering work required to provide enhanced confidence that the path forward identified within future iterations of the IWP will be acceptable to all. (authors)

54 ENVIRONMENTAL SCIENCES↗

Design and Closed‐Loop Motion Planning of an Untethered Swimming Soft Robot Using 2D Discrete Elastic Rods Simulations

Despite tremendous progress in the development of untethered soft robots in recent years, existing systems lack the mobility, model‐based control, and motion planning capabilities of their piecewise rigid counterparts. As in conventional robotic systems, the development of versatile locomotion of soft robots is aided by the integration of hardware design and control with modeling tools that account for their unique mechanics and environmental interactions. Here, a framework for physics‐based modeling, motion planning, and control of a fully untethered swimming soft robot is introduced. This framework enables offline co‐design in the simulation of robot parameters and gaits to produce effective open‐loop behaviors and enables closed‐loop planning over motion primitives for feedback control of a frog‐inspired soft robot testbed. This pipeline uses a discrete elastic rods (DERs) physics engine that discretizes the soft robot as many stretchable and bendable rods. On hardware, an untethered aquatic soft robot that performs frog‐like rowing behaviors is engineered. Hardware validation verifies that the simulation has sufficient accuracy to find the best candidates for sets of parameters offline. The simulator is then used to generate a trajectory library of the robot's motion in simulation that is used in real‐time closed‐loop path following experiments on hardware.

Huang, Xiaonan↗

Cross-Cutting Computational Modeling Project: Integrative Modeling Approach

A wide range of computational models and analyses have been applied to spaceflight risk assessment and countermeasure development. The benefits of using computational modeling to enhance Human Research Program (HRP) goals include the ability to mathematically represent physiological systems, integrate multiple, discrete experimental measures, span multiple temporal and spatial scales, determine important factors within the system and provide estimates of unmeasurable quantities. In the area of application, computational models provide a means of developing simulations to test hypotheses, determining key factors of the system to aid experimental design and bridging gaps in sparse data by mathematically simulating large populations. Specifically, computational models and their supporting analysis tools have the proven potential to integrate analyses of risk factors to enhance mission planning and preparation capabilities and to inform spacecraft design and countermeasure development. Appropriately applied, computational models may allow intelligent, unbiased physiological parameter assessment to enable hypothesis testing and model based design of experiments. HRP recently formed the Computational Modeling Project (CMP), managed out of Glenn Research Center, as a cross-cutting activity aimed at leveraging the growing power and acceptance of computational modeling in informing clinical, physiological, and biological studies. This presentation will provide an overview of the challenges and opportunities in implementing various forms of computational models in support of the HRPs path to risk reduction.

biomechanics↗

SU-E-T-224: Considerations for the Proper Treatment of Multiple Cranial Metastases with Single Isocenter Volumetric Modulated Arc Therapy

Purpose: To investigate some limitations of single isocenter VMAT for cranial multiple met cases. Methods: A single isocenter VMAT plan (Varian, Eclipse AAA10 commissioned down to 1 cm) was designed for two 7mm diameter spherical targets in a rectangular Solid Water (Gammex) phantom. The targets were separated by a distance of 6cm and the isocenter was centered in one of the targets. The plan was delivered (Varian, Truebeam STx) three separate times with different artificial couch angle errors of 0, 0.5 and 1 degree. The coronal dose distributions were measured with calibrated EBT3 film placed at mid-phantom. EBT3 film dosimetry was also performed on the delivery of separate multiple arc vmat plans to targets below 6mm in diameter. Results: Measurements of the sup/inf dose profiles through the high dose distributions show no movement of the central axis high dose region and shifts of the high dose region intended for the off-axis target. For the 1 degree rotation error, the high dose region was shifted 1.04mm from the target. This corresponds to the shift expected from triangulation (60mmxTan(1deg)=1.047mm). Furthermore, a streak of 10% interleaf leakage dose was observed and is likely a Result of the off axis target traveling a wide path such that a long length of MLC is exposed for the whole arc. The calculated dose was about 10% to 15% low compared to that measured on film for a 5mm diameter target. Conclusion: Judicious use of additional margin for off axis targets or limits on the span of multiple mets treated with one isocenter is recommended. The magnitude of the margin should be based on the rotational errors evaluated for the positioning system and the distance of the target from the isocenter. A lower limit of lesion size that can be accurately treated with VMAT should be determined.

60 APPLIED LIFE SCIENCES↗

Design Analysis of a High Temperature Radiator for the Variable Specific Impulse Magnetoplasma Rocket (VASIMR)

The Variable Specific Impulse Magnetoplasma Rocket (VASIMR), currently under development by Ad Astra Rocket Company, is a unique propulsion system that can potentially change the way space propulsion is performed. VASIMR's efficiency, when compared to that of a conventional chemical rocket, reduce propellant needed for exploration missions by a factor of 10. Currently plans include flight tests of a 200 kW VASIMR system, titled VF-200, on the International Space Station. The VF-200 will consist of two 100 kW thruster units packaged together in one engine bus. Each thruster unit has a unique heat rejection requirement of about 27 kW over a firing time of 15 minutes. In order to control rocket core temperatures, peak operating temperatures of about 300 C are expected within the thermal control loop. Design of a high temperature radiator is a unique challenge for the vehicle design. This paper will discuss the path taken to develop a steady state and transient based radiator design. The paper will describe radiator design options for the VASIMR thermal control system for use on ISS as well as future exploration vehicles.

Sheth, Rubik B.↗

Colorado State University (CSU) X-Band Precipitation Radar Plan Position Indicator Data Processed with Corrected Moments in Antenna Coordinates (CMAC) Value-Added Product Report

In 2010 the U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) user facility procured 3- and 5-cm wavelength radars for documenting the macrophysical, microphysical, and dynamical structure of precipitating systems. To maximize the scientific impact, ARM supported the development of an application chain to correct for various phenomena in order to retrieve the “point” values of moments of the radar spectrum and polarimetric measurements. We have now used the lessons learned from the processing of the 3- and 5-cm wavelength radars obtained by ARM to help process X-band radar data from the Surface Atmospheric Integrated Field Laboratory (SAIL) field campaign. This report details the motivation, science, and progress to date as well as charting a path forward.

54 ENVIRONMENTAL SCIENCES↗

SU-F-J-194: Development of Dose-Based Image Guided Proton Therapy Workflow

Purpose: To implement image-guided proton therapy (IGPT) based on daily proton dose distribution. Methods: Unlike x-ray therapy, simple alignment based on anatomy cannot ensure proper dose coverage in proton therapy. Anatomy changes along the beam path may lead to underdosing the target, or overdosing the organ-at-risk (OAR). With an in-room mobile computed tomography (CT) system, we are developing a dose-based IGPT software tool that allows patient positioning and treatment adaption based on daily dose distributions. During an IGPT treatment, daily CT images are acquired in treatment position. After initial positioning based on rigid image registration, proton dose distribution is calculated on daily CT images. The target and OARs are automatically delineated via deformable image registration. Dose distributions are evaluated to decide if repositioning or plan adaptation is necessary in order to achieve proper coverage of the target and sparing of OARs. Besides online dose-based image guidance, the software tool can also map daily treatment doses to the treatment planning CT images for offline adaptive treatment. Results: An in-room helical CT system is commissioned for IGPT purposes. It produces accurate CT numbers that allow proton dose calculation. GPU-based deformable image registration algorithms are developed and evaluated for automatic ROI-delineation and dose mapping. The online and offline IGPT functionalities are evaluated with daily CT images of the proton patients. Conclusion: The online and offline IGPT software tool may improve the safety and quality of proton treatment by allowing dose-based IGPT and adaptive proton treatments. Research is partially supported by Mevion Medical Systems.

60 APPLIED LIFE SCIENCES↗

Regulatory Technology Development Plan - Sodium Fast Reactor: Mechanistic Source Term – Trial Calculation

The potential release of radioactive material during a plant incident, referred to as the source term, is a vital design metric and will be a major focus of advanced reactor licensing. The U.S. Nuclear Regulatory Commission has stated an expectation for advanced reactor vendors to present a mechanistic assessment of the potential source term in their license applications. The mechanistic source term presents an opportunity for vendors to realistically assess the radiological consequences of an incident, and may allow reduced emergency planning zones and smaller plant sites. However, the development of a mechanistic source term for advanced reactors is not without challenges, as there are often numerous phenomena impacting the transportation and retention of radionuclides. This project sought to evaluate U.S. capabilities regarding the mechanistic assessment of radionuclide release from core damage incidents at metal fueled, pool-type sodium fast reactors (SFRs). The purpose of the analysis was to identify, and prioritize, any gaps regarding computational tools or data necessary for the modeling of radionuclide transport and retention phenomena. To accomplish this task, a parallel-path analysis approach was utilized. One path, led by Argonne and Sandia National Laboratories, sought to perform a mechanistic source term assessment using available codes, data, and models, with the goal to identify gaps in the current knowledge base. The second path, performed by an independent contractor, performed sensitivity analyses to determine the importance of particular radionuclides and transport phenomena in regards to offsite consequences. The results of the two pathways were combined to prioritize gaps in current capabilities.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗