Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Particle accelerator sciences”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,405 records · Page 78

Nevada Test Site-Directed Research and Development, FY 2007 Report

The Nevada Test Site-Directed Research and Development (SDRD) program completed a very successful year of research and development activities in FY 2007. Twenty-nine new projects were selected for funding this year, and eight projects started in FY 2006 were brought to conclusion. The total funds expended by the SDRD program were $5.67 million, for an average per-project cost of $153 thousand. An external audit conducted in September 2007 verified that appropriate accounting practices were applied to the SDRD program. Highlights for the year included: programmatic adoption of 8 SDRD-developed technologies; the filing of 9 invention disclosures for innovation evolving from SDRD projects; participation in the tri-Lab Laboratory Directed Research and Development (LDRD) and SDRD Symposium that was broadly attended by Nevada Test Site (NTS), National Nuclear Security Administration (NNSA), LDRD, U.S. Department of Homeland Security (DHS), and U.S. Department of Defense (DoD) representatives; peer reviews of all FY 2007 projects; and the successful completion of 37 R&D projects, as presented in this report. In response to a company-wide call, authors throughout the NTS complex submitted 182 proposals for FY 2007 SDRD projects. The SDRD program has seen a dramatic increase in the yearly total of submitted proposals--from 69 in FY 2002 to 182 this year--while the number of projects funded has actually decreased from a program high of 57 in FY 2004. The overall effect of this trend has helped ensure an increasingly competitive program that benefited from a broader set of innovative ideas, making project selection both challenging and rewarding. Proposals were evaluated for technical merit, including such factors as innovation, probability of success, potential benefit, and mission applicability. Authors and reviewers benefited from the use of a shortfalls list entitled the 'NTS Technology Needs Assessment' that was compiled from NTS, National Weapons Laboratory (NWL), and NNSA sources. This tool continues to be of considerable value in aligning the SDRD program with mission priorities, and was expanded in FY 2007 to include technology development needs from the DHS and other agencies with missions closely aligned to that of the NTS.

43 PARTICLE ACCELERATORS↗

Guidelines for beamline and front-end radiation shielding design at the Advanced Photon Source.

Shielding for the APS will be such that the individual radiation worker dose will be as low as reasonably achievable (ALARA). The ALARA goals for the APS are to keep the total of the work-related radiation exposure (exposure coming from other than natural or medical sources) as far below 500 person-mrem per year, collective total effective dose equivalent, as reasonably achievable. For an individual APS radiation worker, the goal is to keep the maximum occupational total effective dose equivalent of any one employee as far below 200 mrem/yr as reasonably achievable. The ALARA goal for APS beamline scientists is to keep the total of the work-related radiation exposure (exposure coming from other than natural or medical sources) as far below 100 person-mrem per year, collective total effective dose equivalent, as reasonably achievable. For an individual APS beamline scientist, the goal is to keep the maximum occupational total effective dose equivalent of any one scientist as far below 50 mrem/yr as reasonably achievable. The dose is actively monitored by the radiation monitors on the storage ring wall in each sector and by the frequent area surveys performed by the health physics personnel. For cases in which surveys indicate elevated hourly dose rates that may impact worker exposure, additional local shielding is provided to reduce the radiation field to an acceptable level. Passive area monitors are used throughout the facility to integrate doses in various areas. The results are analyzed for trends of increased doses, and shielding in these areas is evaluated and improved, as appropriate. The APS policy for on-site nonradiation workers in the vicinity of the APS facilities requires that the average nonradiation worker dose be below 0.2 mSv/yr (20 mrem/yr). In addition, the dose at the site boundary from all pathways is required to be below 0.1 mSv/yr (10 mrem/yr). For future modifications of the facility, the doses shall be evaluated and additional shielding provided to meet the policy requirements.

43 PARTICLE ACCELERATORS↗

Integrated Program of Experimental Diagnostics at the NNSS. An Integrated, Prioritized Work Plan for Diagnostic Development and Maintenance and Supporting Capability

This Integrated Program of Experimental Diagnostics at the NNSS is an integrated prioritized work plan for the Nevada National Security Site (NNSS), formerly the Nevada Test Site (NTS), program that is independent of individual National Security Enterprise Laboratories’ (Labs) requests or specific Subprograms being supported. This prioritized work plan is influenced by national priorities presented in the Predictive Capability Framework (PCF) and other strategy documents (Primary and Secondary Assessment Technologies Plans and the Plutonium Experiments Plan). This document satisfies completion criteria for FY 2010 MRT milestone #3496: Document an integrated, prioritized work plan for diagnostic development, maintenance, and supporting capability. This document is an update of the 3-year NNSS plan written a year ago, September 21, 2009, to define and understand Lab requests for diagnostic implementation. This plan is consistent with Lab interpretations of the PCF, Primary Assessment Technologies, and Plutonium Experiment plans.

43 PARTICLE ACCELERATORS↗

High Precision Magnetic Field Measurement for the Muon g-2 Experiment

The Muon g-2 experiment at Fermilab will measure the anomalous magnetic moment of the muon, aµ with a precision of 140 ppb, a four-fold improvement over the former BNL E821 result. If the current discrepancy of about 3.5σ between the Standard Model value for aµ and the former experiments was real, then the new experiment would verify the deviation with >7σ significance. The experiment uses muons with the magic momentum of 3.09 GeV/c stored in a very homogeneous magnetic field of a 45 m long storage ring. The determination of aµ requires the precise knowledge of both the anomalous muon spin precession, ωa, and the magnetic field, ωp, expressed in terms of the free-proton Larmor frequency. The field measurement uses the high precision tool of pulsed Nuclear Magnetic Resonance (pNMR) and requires cross-calibrating a set of probes: a very accurate NMR probe calibrates the 17 probes on the in-vacuum field mapping system (the so-called trolley). This trolley in turn is used to map the field over the full azimuth of the storage ring. The trolley measurement also provides the calibration of the 378 fixed probes around the ring that constantly monitor the field drift. This article presents the summary of the entire field measurement system needed to determine ωp. This work was supported in part by the US DOE, Fermilab and US DOE OHEP under contract No. KA2201020.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The NOvA Test Beam Program

NOvA is a long-baseline oscillation neutrino experiment designed to study and measure a wide range of important topics for neutrino physics such as the neutrino mixing parameters, the neutrino mass hierarchy, and CP violation in the lepton sector. The NOvA Test Beam experiment uses a scaled-down detector of 30 tons to analyze tagged beamline particles. A new tertiary beamline deployed at Fermilab can select and identify electrons, muons, pions, kaons and protons with momenta from 0.2 to 2 GeV/c. Using these data, the Test Beam program will provide NOvA with a better understanding of the largest systematic uncertainties impacting the analyses, including the detector response, calibration, and hadronic and electromagnetic energy resolution. The status and future plans for the NOvA Test beam program, along with preliminary results, are presented in these Proceedings.

43 PARTICLE ACCELERATORS↗

NuMI Beam Monitoring Simulation and Data Analysis Status and Progress

With the Main Injector Neutrino Oscillation Search (MINOS) experiment decommissioned, muon and hadron monitors became an important diagnostic tool for the NuMI O↵- axis vμ Appearance (NOvA) experiment at Fermilab to monitor the Neutrinos at the Main Injector (NuMI) beam. The goal of this study is to maintain the quality of the monitor signals and to establish correlations with the neutrino beam profile. And we carry out a systematic study of the response of the muon monitors to the changes in the parameters of the proton beam and lattice parameters. We report here on the progress of the beam data analysis and comparison with the simulation results.

43 PARTICLE ACCELERATORS↗

Improvement of the technique of identification of electrons and positrons with use of electromagnetic calorimeter of the CLAS detector

We study the dependence of the sensitivity of response of the electromagnetic calorimeter of CLAS plant on the momenta of electrons and positrons. We made calculation of this dependence and elaborated a method for its employment in identification of e- and e+. We have shown that the new method of selection of e- and e+ improves the quality of identification by about 10%. We used the experimental data obtained with the plant CLAS of linear accelerator at Jefferson laboratory (USA).

43 PARTICLE ACCELERATORS↗

Radiation Hard Silicon for Medical, Space and High Energy Physics Applications

The objective of this paper is to give an overview on how silicon particle detector would survive operational in extremely harsh radiation environment after luminosity upgrade of the CERN LHC (Large Hadron Collider). The Super-LHC would result in an integrated fluence 1 x 10{sup 16} p/cm{sup 2} and that is well beyond the radiation tolerance of even the most advanced semiconductor detectors fabricated by commonly adopted technologies. The Czochralski silicon (Cz-Si) has intrinsically high oxygen concentration. Therefore Cz-Si is considered as a promising material for the tracking systems in future very high luminosity colliders. The fabrication process issues of Cz-Si are discussed and the formation of thermal donors is especially emphasized. N{sup +}/p{sup -}/p{sup +} and p{sup +}/n{sup -}/n{sup +} detectors have been processed on magnetic Czochralski (MCz-Si) wafers. We show measurement data of AC-coupled strip detectors and single pad detectors as well as experimental results of intentional TD doping. Data of spatial homogeneity of electrical properties, full depletion voltage and leakage current, is shown and n and p-type devices are compared. Our results show that it is possible to manufacture high quality n{sup +}/p{sup -}/p{sup +} and p{sup +}/n{sup -}/n{sup +} particle detectors from high resistivity Czochralski silicon.

43 PARTICLE ACCELERATORS↗

First Results from the VULCAN Diffractometer at the SNS

On Friday June 26, 2009, the neutron beam shutter for the VULCAN diffractometer at the SNS was opened for the first time. Initial measurements to characterize the instrument performance are reported. It is shown that the measurement results are by and large in agreement with design calculations. New research opportunities with VULCAN are discussed.

43 PARTICLE ACCELERATORS↗

Broadband hard X-ray attosecond pulses from extremely chirped electron beams

Attosecond pulses from free-electron lasers have opened the doors to atomic site-specific studies of bound electronic dynamics on their natural, sub-femtosecond timescales. Key to their success has been electron beam shaping techniques enabling the generation of sub-femtosecond current spikes with peak currents on the order of 10 kA. We demonstrate in an RF linac the generation of current spikes with extreme chirps on the order of 350 MeV/micron, directly competitive with the chirps expected from beam-driven plasma wakefield accelerators. Leveraging chirp-taper compensation, we use these highly chirped beams to generate hard X-ray attosecond pulses with bandwidths exceeding 30 eV, a factor of two beyond previous demonstrations. We simultaneously present the first explicit experimental evidence of chirp-taper compensation in an attosecond XFEL, finding that optimal tapering improves the bandwidth and pulse energy by factors of two and five, respectively, for our conditions. In addition to the immediate utility of such broadband hard X-ray pulses, electron beams with such extreme chirps can be utilized for unique new experimental modalities by performing further compression after the undulators. Such post-lasing compression can enable subsequent superradiant light emission at longer wavelengths, or direct excitation of quantum systems with the beam's intense space-charge field for unique attosecond pump-probe possibilities.

43 PARTICLE ACCELERATORS↗

Protection of Hardware: Powering Systems (Power Converter, Normal Conducting, and Superconducting Magnets)

Along with the protection of magnets and power converters, we have added a section on personnel protection because this is our highest priority in the design and operation of power systems. Thus, our topics are the protection of people, power converters, and magnet loads (protected from the powering equipment), including normal conducting magnets and superconducting magnets.

43 PARTICLE ACCELERATORS↗

Beam-Material Interaction

Th is paper is motivated by the growing importance of better understanding of the phenomena and consequences of high-intensity energetic particle beam interactions with accelerator, generic target, and detector components. It reviews the principal physical processes of fast-particle interactions with matter, effects in materials under irradiation, materials response, related to component lifetime and performance, simulation techniques, and methods of mitigating the impact of radiation on the components and environment in challenging current and future applications.

43 PARTICLE ACCELERATORS↗

The Fermilab Short-Baseline Program: MicroBooNE

The MicroBooNE experiment is the first of three detectors of the Fermilab short-baseline neutrino program that started operation in the Booster Neutrino Beamline in October 2015 [1]. When completed, the three-detector lineup will explore short-baseline neutrino oscillations and will be sensitive to sterile neutrino scenarios. MicroBooNE in itself is now starting its own physics program, with the measurement of neutrino-argon cross sections in the ~1GeV range being one of its main physics goals. These proceedings describe the status of the detector, the start of operation, and the automated reconstruction of the first neutrino events observed with MicroBooNE. Prospects for upcoming cross section measurements are also given.

43 PARTICLE ACCELERATORS↗

The Advanced Energetic Pair Telescope for Gamma-Ray Polarimetry

The Advanced Energetic Pair Telescope (AdEPT), a future NASA/GSFC MIDEX mission, is being developed to perform high-sensitivity medium-energy (5-200 MeV) astronomy and revolutionary gamma-ray polarization measurements. The enabling technology for AdEPT is the Three- Dimensional Track Imager (3-DTI), a large volume gaseous time projection chamber with 2- dimentional micro-well detector (MWD) readout. The low density and high spatial resolution of the 3-DTI allows AdEPT to achieve high angular resolution (~0.5 at 67.5 MeV) and, for the first time, exceptional gamma-ray polarization sensitivity. These capabilities enable a wide range of scientific discovery potential for AdEPT. The key science goals of the AdEPT mission include: 1) Explore fundamental processes of particle acceleration in active astrophysical objects, 2) Reveal the magnetic field configuration of the most energetic accelerators in the Universe, 3) Explore the origins and acceleration of cosmic rays and the Galactic MeV diffuse emission, 4) Search for dark matter in the Galactic center, and 5) Test relativity with polarization measurements. We report on the latest developments of the MWDs for the 3-DTI.

Hunter, Stanley D.↗

Scanning Transmission X-ray Microscopy: Applications in Atmospheric Aerosol Research

Scanning transmission x-ray microscopy (STXM) combines x-ray microscopy and near edge x-ray absorption fine structure spectroscopy (NEXAFS). This combination provides spatially resolved bonding and oxidation state information. While there are reviews relevant to STXM/NEXAFS applications in other environmental fields1-4 (and magnetic materials5) this chapter focuses on atmospheric aerosols. It provides an introduction to this technique in a manner approachable to non-experts. It begins with relevant background information on synchrotron radiation sources and a description of NEXAFS spectroscopy. The bulk of the chapter provides a survey of STXM/NEXAFS aerosol studies and is organized according to the type of aerosol investigated. The purpose is to illustrate the current range and recent growth of scientific investigations employing STXM-NEXAFS to probe atmospheric aerosol morphology, surface coatings, mixing states, and atmospheric processing.

43 PARTICLE ACCELERATORS↗

X-ray Topography to Characterize Surface Damage on CdZnTe Crystals

Synthetic CdZnTe or 'CZT' crystals can be used for room temperature detection of {gamma}-radiation. Structural/morphological heterogeneities within CZT, such as twinning, secondary phases (often referred to as inclusions or precipitates), and poly-crystallinity can affect detector performance. As part of a broader study using synchrotron radiation techniques to correlate detector performance to microstructure, x-ray topography (XRT) has been used to characterize CZT crystals. We have found that CZT crystals almost always have a variety of residual surface damage, which interferes with our ability to observe the underlying microstructure for purposes of crystal quality evaluation. Specific structures are identifiable as resulting from fabrication processes and from handling and shipping of sample crystals. Etching was found to remove this damage; however, our studies have shown that the radiation detector performance of the etched surfaces was inferior to the as-polished surface due to higher surface currents which result in more peak tailing and less energy resolution. We have not fully investigated the effects of the various types of inducible damage on radiation detector performance.

43 PARTICLE ACCELERATORS↗