Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PV system”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,405 records · Page 78

Interconnection Assessment Methodology and Cost Benefit Analysis for High-Penetration PV Deployment in the Arizona Public Service System

In an effort to better understand the impacts of high penetrations of photovoltaic (PV) generators on distribution systems, Arizona Public Service and its partners completed a multi-year project to develop the tools and knowledge base needed to safely and reliably integrate high penetrations of utility- and residential-scale PV. Building upon the APS Community Power Project-Flagstaff Pilot, this project investigates the impact of PV on a representative feeder in northeast Flagstaff. To quantify and catalog the effects of the estimated 1.3 MW of PV that will be installed on the feeder (both smaller units at homes and large, centrally located systems), high-speed weather and electrical data acquisition systems and digital 'smart' meters were designed and installed to facilitate monitoring and to build and validate comprehensive, high-resolution models of the distribution system. These models are being developed to analyze the impacts of PV on distribution circuit protection systems (including coordination and anti-islanding), predict voltage regulation and phase balance issues, and develop volt/VAr control schemes. This paper continues from a paper presented at the 2014 IEEE PVSC conference that described feeder model evaluation and high penetration advanced scenario analysis, specifically feeder reconfiguration. This paper presents results from Phase 5 of the project. Specifically, the paper discusses tool automation; interconnection assessment methodology and cost benefit analysis.

14 SOLAR ENERGY↗

A GaN-Based Active Power Decoupling Approach for Enhancing the Efficiency and Reliability of Residential PV Microinverters

It is a common sense that, the reliability of a system is dictated by the life-time of its weakest component. In terms of a single-phase solar photovoltaic (PV) system, including PV panel and the microinverter, the reliability of the system is confined by the electrolytic dc-link capacitor at the input of its microinverter. To enhance the reliability of the system by providing the possibility of employing film capacitors, with higher life-time rather than their electrolytic counterparts, this paper presents a novel modeling, design, and control of a PV-side active power decoupling (APD) approach. Besides, GaN FETs are employed to achieve a superior efficiency and power density of the APD. The proposed methodology is verified through a thorough design, loss modeling, and numerical analysis.

14 SOLAR ENERGY↗

Holographic Spectrum Splitting Demonstration System for Duel Photovoltaic and Biofuel Operation

Spectrum splitting is an optical technique that can increase conversion efficiency or add energy storage capability to a photovoltaic (PV) energy system. In this Sandia National Laboratory Campus Executive project, two distinct types of Diffractive Optical Elements (DOEs) for spectrum splitting were developed, fabricated and measured. The first DOE was an algorithmically-designed freeform surface relief structure. A parametric study of the Broadband Gerchberg-Saxton algorithm was performed to show the effect of design variables on device performance. Two DOE designs were fabricated using a grayscale Maskless Lithography Tool (MLT) and measured. The second DOE was a volume holographic lens. This concept was explored in the context of hybrid PV/biofuel implementation, and was later applied to a multiple-bandgap PV module. A design process was developed to ensure diffraction into a single order across the lens and to enable spectral tuning of diffracted light. A proof-of-concept off-axis holographic lens was fabricated and measured. The report concludes with a summary of spectrum splitting performance and discussion of areas for improvement and future work.

09 BIOMASS FUELS↗

Machine Learning-Based PV Reserve Determination Strategy for Frequency Control on the WECC System: Preprint

Frequency control from Photovoltaic (PV) plants has great potential to address the frequency response challenge of the power system with high renewable penetration. However, using model-based approaches to determine the optimal PV headroom reserve requires significant online computation and is intractable for an interconnection level system. This paper proposes a machine learning based strategy, that is suitable for real-time operation, to determine the optimal PV reserve for frequency control. The proposed machine learning algorithm is trained and tested on 1,987 offline simulations of a 60% renewable penetration Western Electricity Coordinating Council (WECC) system. Furthermore, the proposed reserve determination strategy is applied on a realistic one-day operation profile of the WECC system and demonstrates over 40% PV headroom saving compared to a conservative approach. It is evident that the proposed strategy can efficiently and effectively determine the optimal PV frequency control reserve for realistic interconnection systems.

41 EE - Solar Energy Technologies Office (EE-4S)↗

High-Penetration Photovoltaic Planning Methodologies

The main objective of this report is to provide an overview of select U.S. utility methodologies for performing high-penetration photovoltaic (HPPV) system planning and impact studies. This report covers the Federal Energy Regulatory Commission's orders related to photovoltaic (PV) power system interconnection, particularly the interconnection processes for the Large Generation Interconnection Procedures and Small Generation Interconnection Procedures. In addition, it includes U.S. state interconnection standards and procedures. The procedures used by these regulatory bodies consider the impacts of HPPV power plants on the networks. Technical interconnection requirements for HPPV voltage regulation include aspects of power monitoring, grounding, synchronization, connection to the overall distribution system, back-feeds, disconnecting means, abnormal operating conditions, and power quality. This report provides a summary of mitigation strategies to minimize the impact of HPPV. Recommendations and revisions to the standards may take place as the penetration level of renewables on the grid increases and new technologies develop in future years.

14 SOLAR ENERGY↗

Approaches to Demonstrating Bankability and Differentiating Product Quality (Presentation)

As the PV Industry has matured, there is increasing interest in quantifying higher quality so that customers may select products that meet their needs, and investors are demanding high confidence before committing millions of dollars. The community is developing the knowledge and standard methods needed to address these. This talk will give an overview of new developments in the last year including descriptions and status of Qualification Plus (a test protocol that goes beyond the standard qualification tests), a PV-specific version of ISO 9001 (for increased confidence in manufacturing consistency), and the Regional Test Centers (where new products can be tested to quantify performance and durability in multiple climate zones.) Development of PV system-level certification will also be described.

14 SOLAR ENERGY↗

Selecting Solar: Insights into Residential Photovoltaic (PV) Quote Variation

Before investing in a system, a prospective PV customer must not only have initial concept 'buy in,' but also be able to evaluate the tradeoffs associated with different system parameters. Prospective customers might need to evaluate disparate costs for each system attribute by comparing multiple bids. The difficulty of making such an evaluation with limited information can create a cognitive barrier to proceeding with the investment. This analysis leverages recently available data from EnergySage, an online solar marketplace, to offer the first data-driven characterization of quote variation faced by prospective PV customers, lending early insight into the decisions customers face once they have initial buy-in.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Performance and Techno-Economic Evaluation of a Three-Phase, 50-kW SiC-Based PV Inverter

The technical capabilities and benefits of silicon carbide (SiC) compared to silicon (Si) based power electronics converters as well as the premium associated with using SiC instead of Si are well understood. This work proves that the benefits provided by SiC, such as increased efficiency, would result in a lower levelized cost of energy (LCOE) compared to both commercially available, state-of-the-art inverters and the benchmark commercial system cost calculated for the U.S. Department of Energy Solar Energy Technologies Office's SunShot program. The LCOE is calculated to be same as the commercial benchmark despite the installed system cost being 8% more than the benchmark. The LCOE calculation is based on both experiential values obtained from testing the SiC photovoltaic (PV) inverter and on the bottoms-up modeled volume cost for the same 50-kW SiC-based inverter. The PV system used for the LCOE model is also explained, and the system cost breakout is presented in this paper. Furthermore, multiple scenarios with variations in the PV system are presented to show their effect on the system LCOE.

14 SOLAR ENERGY↗

FTIR Investigation of EVA Chemical Bonding Environment and Its Impact on Debond Energy

The chemical makeup of ethylene vinyl acetate (EVA) interfaces in photovoltaic (PV) modules is probed via Fourier-transform infrared spectroscopy (FTIR) to determine the impact of the EVA formulation on the adhesion degradation. EVA samples laminated with glass particles are used to demonstrate the effect of damp heat exposure on the glass-EVA interface, showing that increasing silane content increases chemical stability. Delamination interfaces created in one cell modules demonstrate a high correlation between the siloxane bonding at the silicon cell-EVA interface and the debond energy. A significant decrease in debond energy after UV exposure is also shown to be due in part to decreasing siloxane bond density at the interface. However, FTIR results indicated contributions to the adhesion beyond the chemical interface, and a basic tensile test indicates increasing bulk mechanical properties with increasing silane. These results demonstrate the importance of the EVA formulation on its adhesion performance and long-term reliability. Furthermore, it is shown that FTIR is a capable technique for assessing and quantifying chemical mechanisms within PV modules. These results can then be used to more effectively model module lifetimes and to better design polymer systems for PV modules.

14 SOLAR ENERGY↗

Segmented Energy Routing for a Modular AC/DC Hybrid System

This article presents a modular ac/dc system with both distributed and centralized power ports for energy router (ER) applications. In each module of the described system, photovoltaic (PV) power generation units, battery-type energy storage (ES) units, and critical loads are connected to the cascaded H-bridge (CHB)-organized medium-voltage (MV) dc links, with fully distributed low-voltage (LV) dc power ports. Copies of modules share the centralized load bus and interact with an MV ac grid in parallel. Hybrid power port (HPO) assigns flexibility to the system but makes energy routings a necessity for stable operation. In this article, a segmented energy management strategy for the HPO-ER is proposed. In terms of the grid-side power transferring, the system ratings are intentionally designed to match significant power imbalance. Focally, a segmented energy management strategy is proposed to realize fully autonomous energy routing involving MV ac grid, distributed PV generations, distributed battery storages, and LV load. The system is proven to be stable using the derived impedance-based model considering the interaction between power blocks. The feasibility of the topology and control strategy is also verified through software simulation, laboratorial hardware prototype experiment, and hardware-in-the-loop (HIL) emulation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Common Mode Voltage Reduction of Single-Phase Quasi-Z-Source Inverter-Based Photovoltaic System

A common mode voltage (CMV) reduction method is proposed for the active power filter (APF) integrated single-phase quasi-Z-source inverter (qZSI) based photovoltaic (PV) power system. The APF integrated qZSI completely compensates the dc-side double-line-frequency (2ω) ripple through the APF capacitor, while maintaining low qZS inductance and capacitance. The proposed method reduces the CMV amplitude to half of that using the traditional sinusoidal pulse width modulation (SPWM). The switching and conduction power losses are analyzed. Simulation and experimental results demonstrate the proposed method reduces CMV without comprising performance and efficiency of the APF integrated single-phase qZSI.

42 ENGINEERING↗

Effect of Torque-Tube Parameters on Rear-Irradiance and Rear-Shading Loss for Bifacial PV Performance on Single-Axis Tracking Systems

The emergence of cost-competitive bifacial PV modules has raised the question of the additional value of bifacial 1-axis tracking arrays, in particular when considering rear-irradiance losses from the tracker system itself. In this work, the effect of different geometries and materials of torque tubes is evaluated through ray-trace simulations and found to cause rear irradiance shading factors between 2% to 8% for systems without gap between the modules in 2-UP configuration. Inclusion of a gap between the modules can offset the shading factor. Electrical mismatch is also evaluated for the various configurations, and a methodology to apply shading factor and electrical mismatch loss to rear irradiance from the calculated loss in DC power, which averages 1% for the systems explored here, is proposed.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Simplified Method for Modeling the Impact of Arbitrary Partial Shading Conditions on PV Array Performance: Preprint

It is often difficult to model the effects of partial shading conditions on PV array performance, as shade losses are nonlinear and depend heavily on a system's particular configuration. This work describes and implements a simple method for modeling shade loss: a database of shade impact results (loss percentages), generated using a validated, detailed simulation tool and encompassing a wide variety of shading scenarios. The database is intended to predict shading losses in crystalline silicon PV arrays and is accessed using basic inputs generally available in any PV simulation tool. Performance predictions using the database are within 1-2% of measured data for several partially shaded PV systems, and within 1% of those predicted by the full, detailed simulation tool on an annual basis. The shade loss database shows potential to considerably improve performance prediction for partially shaded PV systems.

14 SOLAR ENERGY↗

PV Fleet Performance Data Initiative Final Technical Report (FTR)

Improved analysis and reporting of photovoltaic (PV) field performance increases the certainty of owners and financiers that systems will perform as expected. Advanced module technologies (e.g., PERC, HJT, and bifacial) introduce new degradation mechanisms and performance characteristics. This project will leverage data from the ever-increasing PV fleet to develop models and understanding of the field performance of existing and new technologies. Please see our list of public reports at https://www.nrel.gov/pv/fleet-performance-data-initiative.html. Objective 1: Support the global PV industry with scalable, robust data analysis tools that reduce the uncertainty of PV system performance and loss calculation. Objective 2: Reduce perceived risk arising from degradation rate, soiling loss, and system availability by publishing detailed statistics on U.S. fleet performance. Objective 3: Highlight factors leading to system underperformance including module type, climate, mounting configuration, etc. Objective 4: Enable continued high system performance in modern PV systems, as turnover and advances in technology bring new suppliers and high-efficiency modules into the market.

14 SOLAR ENERGY↗

Overview of the Habitat Demonstration Unit Power System Integration and Operation at Desert RATS 2010

A habitat demonstration unit (HDU) was constructed at NASA Johnson Space Center (JSC) and designed by a multicenter NASA team led out of NASA Kennedy Space Center (KSC). The HDU was subsequently utilized at the 2010 Desert Research and Technology Studies (RATS) program held at the Black Point Lava Flow in Arizona. This report describes the power system design, installation and operation for the HDU. The requirements for the power system were to provide 120 VAC, 28 VDC, and 120 VDC power to the various loads within the HDU. It also needed to be capable of providing power control and real-time operational data on the load's power consumption. The power system had to be capable of operating off of a 3 phase 480 VAC generator as well as 2 solar photovoltaic (PV) power systems. The system operated well during the 2 week Desert RATS campaign and met all of the main goals of the system. The power system is being further developed to meet the future needs of the HDU and options for this further development are discussed.

Colozza, Anthony J.↗

Feasibility Study of Economics and Performance of Solar Photovoltaics at Johnson County Landfill

The U.S. Environmental Protection Agency (EPA), in accordance with the RE-Powering America's Land initiative, selected the Johnson County Landfill in Shawnee, Kansas, for a feasibility study of renewable energy production. Citizens of Shawnee, city planners, and site managers are interested in redevelopment uses for landfills in Kansas that are particularly well suited for grid-tied solarphotovoltaic (PV) installation. This report assesses the Johnson County Landfill for possible grid-tied PV installations and estimates the cost, performance, and site impacts of three different PV options: crystalline silicon (fixed tilt), crystalline silicon (single-axis tracking), and thin film (fixed tilt). Each option represents a standalone system that can be sized to use an entire available site area. In addition, the report outlines financing options that could assist in the implementation of a system. The feasibility of PV systems installed on landfills is highly impacted by the available area for an array, solar resource, operating status, landfill cap status, distance to transmission lines, and distance to major roads. The report findings are applicable to other landfills in the surrounding area.

14 SOLAR ENERGY↗

PV Generation Enhancement with a Virtual Inertia Emulator to Provide Inertial Response to the Grid

With high-penetration levels of renewable generating sources being integrated into the existing electric power grid, conventional generators are being replaced and grid inertial response is deteriorating. This technical challenge is more severe with photovoltaic (PV) generation than with wind generation because PV generation systems cannot provide inertial response unless special countermeasures are adopted. To enhance the inertial response, this paper proposes to synthesize a virtual inertia emulator (VIE) by using a battery energy storage system (BESS) and a three-phase grid-tied inverter to simulate a traditional generator such that the inertial response can be appropriately enhanced without sacrificing energy efficiency. Control systems for the VIE are presented in this paper, along with simulation results from PSCAD and MATLAB to validate the effectiveness of the proposed scheme.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Recent Improvements in PV+Battery Modeling in NREL's System Advisor Model

This poster covers recent updates to the NREL System Advisor Model's battery model that can be coupled to the PV model to add value to both front of meter and behind the meter systems. Topics include new dispatch algorithms focusing on smoothing the output of a PV plant to meet ramp rate requirements and responding to price signals to maximize system revenue, validated battery lifetime models, grid outage simulations and resiliency metrics, and the new levelized cost of storage (LCOS) metric. We will also share preliminary results from NREL analysis projects using these features.

battery↗