Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PUMPING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,405 records · Page 78

Attosecond-pump attosecond-probe x-ray spectroscopy of liquid water

Attosecond-pump/attosecond-probe experiments have long been sought as the most straightforward method for observing electron dynamics in real time. Although there has been much success with overlapped near-infrared femtosecond and extreme ultraviolet attosecond pulses combined with theory, true attosecond-pump/attosecond-probe experiments have been limited. Here we used a synchronized attosecond x-ray pulse pair from an x-ray free-electron laser to study the electronic response to valence ionization in liquid water through all x-ray attosecond transient absorption spectroscopy (AX-ATAS). Our analysis showed that the AX-ATAS response is confined to the subfemtosecond timescale, eliminating any hydrogen atom motion and demonstrating experimentally that the 1b 1 splitting in the x-ray emission spectrum is related to dynamics and is not evidence of two structural motifs in ambient liquid water.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The Exciton–Polariton Dispersion Law under the Action of Strong Pumping in the Region of the M-Band of Luminescence

The double-pulse interaction with excitons and biexcitons in semiconductors is studied theoretically. It is shown that the dispersion law of carrier wave has three branches under the action of a powerful pumping in the region of the M-band of luminescence. Values of parameters at which the dispersion law branches can intersect due to the degeneration of the exciton level energy have been found. The effect of a significant change in the force of coupling between the exciton and photon of a weak pulse with a change in the pumping intensity is predicted.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Adaptive Stiffness Power Take-Off System for a Hydraulic Hose-Pump Point Absorber Wave Energy Converter

Two crucial challenges faced in the design of ocean wave energy converters (WECs) are maintaining high capacity factors and remaining robust in everchanging, harsh ocean environments. This study introduces a novel mechanism for achieving reactive WEC control with a soft hydraulic power take-off, thereby addressing both challenges. The device of interest involves a hydraulic pump, constructed from a fluidic flexible matrix composite (F2MC), which is cyclically stretched by driving waves and pressurizes working fluid through a turbine-generator. This class of fiber-reinforced stretch hoses is established for ocean use as robust moorings and shock absorbers. The dynamic properties of the F2MC pump depend on internal pressure, which can be controlled by a continuously variable transmission between the turbine and generator, allowing the system to be adapted for better performance over a wide range of wave conditions. This work presents a dynamic model for operation and adaptive behavior of this power take-off system, experimentally validates components of the model, and performs dynamic simulations of the system that show increases in power production and capacity factor compared to non-adaptive operation for a variety of driving wave conditions. This work develops the basis for future large-scale experimental testing and controller design of this system.

Wave energy conversion, fluidic flexible matrix co↗

Groundwater Remediation with Pump-and-Treat Technology

Pump-and-treat (P&T) is a widely used remediation technology that involves pumping groundwater from extraction wells in the subsurface, removing contaminants of concern from the groundwater in an aboveground treatment system, reintroducing treated water into the environment – often by injection back into the groundwater aquifer or by discharge to the surface–, and groundwater monitoring to evaluate performance. In this chapter we explore how the Hanford Site uses the P&T remediation approach to treat contaminated groundwater. Six P&T facilities currently operate at the Hanford Site; however, this chapter uses the 100 Area DX and HX P&T facilities' treatment of hexavalent chromium as a case study to discuss this remediation approach. Located in the River Corridor, HX and DX P&T facilities are much closer to reaching closure than the younger 200W P&T facility located in the Central Plateau’s 200W Area. As such, one can follow the historical design, operation, and optimization steps that have led these facilities closer to closure.

Saslow, Sarah A.↗

Identifying a forward-scattering superconductor through pump-probe spectroscopy

Electron-boson scattering that is peaked in the forward direction has been suggested as an essential ingredient for enhanced superconductivity observed in FeSe monolayers. Here, we study the superconducting state of a system dominated by forward scattering in the time domain and contrast its behavior against the standard isotropic BCS case for both s- and d-wave symmetries. An analysis of the electron's dynamics in the pump-driven non-equilibrium state reveals that the superconducting order in the forward-focused case is robust and persistent against the pump-induced perturbations. The superconducting order parameter also exhibits a non-uniform melting in momentum space. We show that this behavior is in sharp contrast to the isotropic interaction case and propose that time-resolved approaches are a potentially powerful tool to differentiate the nature of the dominant coupling in correlated materials.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Multi-atmosphere picosecond CO 2 amplifier optically pumped at 4.3 μm

The possibility of the amplification of picosecond 10 μmpulses to GW powers in an optically pumped 20 atmosphere CO 2 laser is shown using numerical simulations. Here, multi-mJ 4.3 μm pulses generated by a tunable Fe:ZnSe laser are considered for pumping.

43 PARTICLE ACCELERATORS↗

Direct diode pumped Ti:sapphire ultrafast regenerative amplifier system

Here, we report on a direct diode-pumped Ti:sapphire ultrafast regenerative amplifier laser system producing multi-uJ energies with repetition rate from 50 to 250 kHz. By combining cryogenic cooling of Ti:sapphire with high brightness fiber-coupled 450nm laser diodes, we for the first time demonstrate a power-scalable CW-pumped architecture that can be directly applied to demanding ultrafast applications such as coherent high-harmonic EUV generation without any complex post-amplification pulse compression. Initial results promise a new era for Ti:sapphire amplifiers not only for ultrafast laser applications, but also for tunable CW sources. We discuss the unique challenges to implementation, as well as the solutions to these challenges.

07 ISOTOPE AND RADIATION SOURCES↗

High-average-power, 2-μm femtosecond optical parametric oscillator synchronously pumped by a thin-disk, mode-locked laser

A high-energy, extended-cavity femtosecond BiBO optical parametric oscillator synchronously pumped by a 1.0-ps, 1030-nm Yb:YAG, thin-disk pump laser is presented. The oscillator operated near degeneracy in a noncollinear interaction geometry, producing signal wavelength tunability from 1.99 to 2.20 μm. The signal pulses have an average power exceeding 2 W, producing 455-fs pulses at 7.08 MHz with energies up to 350 nJ, showing increased potential for tunable sources of scalable ultrafast pulses in the infrared.

36 MATERIALS SCIENCE↗

Final amplifier of an ultra-intense all-OPCPA system with 13-J output signal energy and 41% pump-to-signal conversion efficiency

Optical parametric chirped-pulse amplification (OPCPA) using high-energy Nd:glass lasers has the potential to produce ultra-intense pulses (>10 23 W/cm 2 ). We report on the performance of the final high-efficiency amplifier in an OPCPA system based on large-aperture (63 × 63-mm 2 ) partially deuterated potassium dihydrogen phosphate (DKDP) crystals. The seed beam (180-nm bandwidth, 110 mJ) was provided by the preceding OPCPA stages. A maximum pump-to-signal conversion efficiency of 41% and signal energy up to 13 J were achieved with a 52-mm-long DKDP crystal due to the flattop super-Gaussian pump beam profile and flat-in-time pulse shape.

47 OTHER INSTRUMENTATION↗

Amplification of 10 μm picosecond pulses in a compact optically pumped multiatmosphere CO 2 laser

Picosecond pulses, generated by a commercial mid-IR optical parametric source (∼0.5 ps, 1-5 μJ), have been regeneratively amplified to an energy of ≤2 mJ in a palm-size high-pressure CO 2 amplifier optically pumped by a Q-switched 2.8 μm Cr:Er:YSGG laser. The characteristics of the amplified pulses have been studied as a function of seed wavelength centered around 10.3 or 10.6 μm, and the pressure in the gain medium. The measured amplified pulse length is ∼5 ps. Numerical modeling suggests that pulses as short as ∼0.5 ps with multi-GW peak power can be generated in a mixture of CO 2 isotopes. Robustness of the output of a compact CO 2 regenerative amplifier to the seed and pump fluctuations measured at 3 Hz and a perfect Gaussian beam profile indicates the potential of such laser technology for producing high-power ultrashort long-wave infrared pulses at high repetition rates.

43 PARTICLE ACCELERATORS↗

Pump–probe spectrometer for measuring x-ray induced strain

A hard x-ray pump–probe spectrometer using a multi-crystal Bragg reflector is demonstrated at a third generation synchrotron source. This device derives both broadband pump and monochromatic probe pulses directly from a single intense, broadband x-ray pulse centered at 8.767 keV. In conclusion, we present a proof-of-concept experiment which directly measures x-ray induced crystalline lattice strain.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

On the importance of electron impact processes in excimer-pumped alkali laser-induced plasmas

We present that the excimer-pumped alkali laser (XPAL) system has recently been demonstrated in several different mixtures of alkali vapor and rare gas. Without special preventive measures, plasma formation during operation of XPAL is unavoidable. Some recent advancements in the availability of reliable data for electron impact collisions with atoms and molecules have enabled development of a complete reaction mechanism to investigate XPAL-induced plasmas. Here, we report on pathways leading to plasma formation in an Ar/C 2 H 6 /CsAr/C2H6/Cs XPAL sustained at different cell temperatures. We find that depending on the operating conditions, the contribution of electron impact processes can be as little as bringing the excitation of Cs(P 2 ) states to higher level Cs** states, and can be as high as bringing Cs(P 2 ) excited states to a full ionization. Increasing the input pumping power or cell temperature, or decreasing the C 2 H 6 mole fraction leads to electron impact processes dominating in plasma formation over the energy pooling mechanisms previously reported in literature.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Demonstration of a compact, multi-joule, diode-pumped Tm:YLF laser

We report the demonstration of a diode-pumped Tm:YLF laser operating at 1.88 µm that produces pulse energies up to 3.88 J in 20 ns. The compact system consists of a Q-switched cavity-dumped oscillator generating 18 mJ pulses, which are then amplified in a 4-pass power amplifier. Energies up to 38.1 J were obtained with long-pulse amplifier operation. These results illustrate the high energy storage and extraction capabilities of diode-pumped Tm:YLF, opening the path to high peak and average power mid-infrared solid-state lasers

47 OTHER INSTRUMENTATION↗

Ultrabroadband two-dimensional electronic spectroscopy in the pump–probe geometry using conventional optics

We report ultrabroadband two-dimensional electronic spectroscopy (2D ES) measurements obtained in the pump–probe geometry using conventional optics. A phase-stabilized Michelson interferometer provides the pump-pulse delay interval,τ 1 , necessary to obtain the excitation-frequency dimension. Spectral resolution of the probe beam provides the detection-frequency dimension,ω 3 . The interferometer incorporates active phase stabilization via a piezo stage and feedback from interference of a continuous-wave reference laser detected in quadrature. To demonstrate the method, we measured a well-characterized laser dye sample and obtained the known peak structure. The vibronic peaks are modulated as a function of the waiting time,τ 2 , by vibrational wave packets. The interferometer simplifies ultrabroadband 2D ES measurements and analysis.

Optics↗

Single-shot picosecond pump coherent Rayleigh scattering thermometry

A single-shot coherent Rayleigh scattering (CRS) technique capable of measurement times less than 10 ns is presented. Here, the use of a mode-locked picosecond pump laser yields repeatable electrostrictive forcing compared to previous CRS experiments using unseeded nanosecond pump pulses, which are beset by shot-to-shot variations. Quantitative measurements are achieved by dispersing the CRS signal onto an EMCCD sensor using a virtually imaged phased array and comparing the experimental spectra to an existing kinetic model with a least-squares fitting routine. Measurements are demonstrated at ambient and low-pressure (2 Torr), low-temperature (100 K) conditions where the CRS measurement is within the collisionless regime. Single-shot statistics indicated precision and accuracy within 4% at ambient conditions and within 8% at low density and temperature conditions. This single-shot CRS technique is a powerful diagnostic tool with potential for multi-parameter measurements in complex flow environments, including high-speed aerodynamic ground test facilities.

Senior, William Charles Bowman [Sandia National La↗

Radiative pumping of exciton-polaritons in 2D hybrid perovskites

In addition to their attractive technological applications in photovoltaics and light emitters, the perovskite family of semiconductors has recently emerged as an excellent excitonic material for fundamental studies. Specifically, the 2D hybrid organic-inorganic perovskite (HOIP) offers the added advantage of room temperature investigations owing to their large exciton binding energy. In this work, we strongly couple excitons in 2D HOIP crystals to planar microcavity photons sustaining exciton-polaritons under ambient conditions resulting in a Rabi splitting of 290 meV. Dark excitons directly pump the polariton branch along its dispersion in resonance with the Stokes shifted emission state (radiative pumping), creating a high density of polaritons at higher in-plane momentum ( k || ). We further probe the nonlinear polariton dispersion dynamics at varying input laser fluence, which indicates efficient polariton-polariton scattering and decay to k || = 0 from higher k || . The observation of Stokes shift-assisted energy exchange of dark states with lower polaritons coupled with evidence of efficient polariton-polariton scattering makes 2D HOIPs an attractive platform to study exciton-polariton many-body physics and Bose-Einstein like condensation (BEC) at room temperature.

36 MATERIALS SCIENCE↗

Natural Variation in the Multidrug Efflux Pump SGE1 Underlies Ionic Liquid Tolerance in Yeast

Imidazolium ionic liquids (IILs) have a range of biotechnological applications, including as pretreatment solvents that extract cellulose from plant biomass for microbial fermentation into sustainable bioenergy. However, residual levels of IILs, such as 1-ethyl-3-methylimidazolium chloride ([C 2 C 1 im]Cl), are toxic to biofuel-producing microbes, including the yeast Saccharomyces cerevisiae. S. cerevisiae strains isolated from diverse ecological niches differ in genomic sequence and in phenotypes potentially beneficial for industrial applications, including tolerance to inhibitory compounds present in hydrolyzed plant feedstocks. We evaluated >100 genome-sequenced S. cerevisiae strains for tolerance to [C 2 C 1 im]Cl and identified one strain with exceptional tolerance. By screening a library of genomic DNA fragments from the [C 2 C 1 im]Cl-tolerant strain for improved IIL tolerance, we identified SGE1, which encodes a plasma membrane multidrug efflux pump, and a previously uncharacterized gene that we named ionic liquid tolerance 1 (ILT1), which encodes a predicted membrane protein. Analyses of SGE1 sequences from our panel of S. cerevisiae strains together with growth phenotypes implicated two single nucleotide polymorphisms (SNPs) that associated with IIL tolerance and sensitivity. We confirmed these phenotypic effects by transferring the SGE1 SNPs into a [C 2 C 1 im]Cl-sensitive yeast strain using CRISPR/Cas9 genome editing. Further studies indicated that these SNPs affect Sge1 protein stability and cell surface localization, influencing the amount of toxic IILs that cells can pump out of the cytoplasm. Our results highlight the general potential for discovering useful biotechnological functions from untapped natural sequence variation and provide functional insight into emergent SGE1 alleles with reduced capacities to protect against IIL toxicity.

09 BIOMASS FUELS↗

QA/QC of the East River, Colorado, discharge and geochemical time series datasets (Almont, BCC, and Pump House) to be used for modeling of hydrogeochemical balance

The following datasets were QA/QC-ed (Quality Assurance/Quality Control): 1. Brush Creek Confluence (BCC) discharge data (from Helen Malenda, USGS, Colorado School of Mines), which were calculated using the pressure transducer data and rating curves. The original 15 min time series data were presented as mean daily discharge. 2. Almont discharge data from United States Geological Survey (USGS). The original data were in 15 min time intervals, and were averaged to mean daily discharge time series. 3. Pump House discharge data as mean daily discharge (downloaded from the SFA portal). 4. BCC and Pump House chemistry data from SFA data portal and/or original spreadsheets provided by Roelof Versteeg. The following challenging QA/QC problems of the datasets were resolved: Missing data with the duration of gaps up to >1 month; Duplicated dates; Anomalies and outliers of discharge and concentrations; Time stamps of measurements of the discharge and concentrations are not aligned (hydrogeochemical balance calculations require the timestamps to be aligned). All QA/QC-ed datasets are given as csv files. The csv files were prepared using the xts files with multiple worksheets, which are also included in the data packages. Figures of the QA/QC-ed datasets are given in the jpeg and pdf formats. The QA/QC-ed datasets have been used to quantify discharge and chemical concentrations in river water in order to understand riverine exports of water and dissolved constituents in the East River watershed. These datasets served as a basis in the presentation given by P. Fox et al. at the 2021 Goldschmidt Conference.

54 ENVIRONMENTAL SCIENCES↗