Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PHASE DETECTOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,405 records · Page 78

India-based neutrino observatory (INO): Physics reach and status report

We present a review of the physics reach and current status of the proposed India-based Neutrino Observatory (INO). We briefly outline details of the INO location and the present status of detector development. We then present the physics goals and simulation studies of the main detector, the magnetised Iron Calorimeter (ICAL) detector, to be housed in INO. The ICAL detector would make precision measurements of neutrino oscillation parameters with atmospheric neutrinos including a measurement of the neutrino mass hierarchy. Additional synergies with other experiments due to the complete insensitivity of ICAL to the CP phase are also discussed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Beam tracking approach for single–shot retrieval of absorption, refraction, and dark-field signals with laboratory x-ray sources

We present the translation of the beam tracking approach for x-ray phase-contrast and dark-field imaging, recently demonstrated using synchrotron radiation, to a laboratory setup. A single absorbing mask is used before the sample, and a local Gaussian interpolation of the beam at the detector is used to extract absorption, refraction, and dark–field signals from a single exposure of the sample. Multiple exposures can be acquired when high resolution is needed, as shown here. A theoretical analysis of the effect of polychromaticity on the retrieved signals, and of the artifacts this might cause when existing retrieval methods are used, is also discussed.

43 PARTICLE ACCELERATORS↗

Ultra-high-bandwidth polarization interferometry and optimal quadratic phase detection

A novel homodyne interferometer and analysis method are described which use orthogonal polarization components to measure large rapid changes in interferometric phase, in quadrature, in the presence of strong time-dependent attenuation of the scene beam. Here, this approach overcomes the major sources of error associated with homodyne interferometry (sensitivity nulls, ambiguity in the direction of phase change when passing through a sensitivity null, and intolerance to beam power variations) while maintaining its intrinsic simplicity and speed, enabling extremely high-bandwidth, high-dynamic range measurements limited only by available detector technology. Using this technique, electron density in a magnetized plasma shock was measured with unprecedented bandwidth and resolution, revealing short-timescale features not previously observed.

47 OTHER INSTRUMENTATION↗

Centrality determination with a forward detector in the RHIC Beam Energy Scan

Recently, Chatterjee et al [1] used a hadronic transport model to estimate the resolution with which various experimental quantities select the impact parameter of relativistic heavy ion collisions at collision energies relevant to the Beam Energy Scan (BES) program at the Relativistic Heavy Ion Collider (RHIC). Measures based on particle multiplicity at forward rapidity were found to be significantly worse than those based on midrapidity multiplicity. Using the same model, we show that a slightly more sophisticated measure greatly improves the resolution based on forward rapidity particles; this improvement persists even when the model is filtered through a realistic simulation of a recent upgrade detector to the STAR experiment. Furthermore, these results highlight the importance of optimizing centrality measures based on particles detected at forward rapidity, especially for experimental studies that search for a critical point in the QCD phase diagram. Such measurements usually focus on proton multiplicity fluctuations at midrapidity, hence selecting events based on multiplicity at midrapidity raises the possibility of nontrivial autocorrelations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Status of NICA project

The project of Nuclotron-based Ion Collider fAcility NICA/MPD (+MultiPurpose Detector) under development at JINR (Dubna) is presented. The general goals of the project are providing of colliding beams for experimental studies of both hot and dense strongly interacting baryonicmatter and search for the mixed phase and critical endpoint and spin physics in collisions of polarized protons (deuterons). The first program requires providing of heavy-ion collisions in the energy range of {radical}s{sub NN} = 4 - 11 GeV at average luminosity of L = 1 Multiplication-Sign 10{sup 27} cm{sup -2} s{sup -1} for {sup 197}Au{sup 79+}. The polarized beams mode is proposed to be used in energy range of {radical}s = 12 - 27 GeV (protons) at luminosity of L {>=} 1 Multiplication-Sign 10{sup 30} cm{sup -2} s{sup -1}. The report contains description of the facility scheme and characteristics in heavy-ion operation mode, status and plans of the project development.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

TTDAQ: A Continuous Flow, Timing and Trigger DAQ System

Final Scientific/Technical Report for DOE Award DE-SC0019581, “TTDAQ: A Continuous Flow, Timing and Trigger DAQ System.” The report summarizes Telluric Labs’ Phase II STTR work developing silicon-photonic building blocks for a software-defined, continuous-flow, trigger-less data acquisition system for next-generation high-energy and nuclear-physics detectors. The project focused on radiation-hard photonic integrated circuits, remote optical illumination, dense wavelength-division multiplexing, and a differential microring-resonator transceiver architecture designed to improve high-speed optical link stability and bandwidth. The report describes project objectives, technical accomplishments, AIM Photonics tape-outs, bench characterization, radiation-hardness testing, deferred integration work, and potential applications beyond physics readout.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Review of Heavy Flavor Physics at the Tevatron

The D0 and CDF detectors at the Fermilab Tevatron have each accumulated more that 9 fb{sup -1} of integrated luminosity. The corresponding large datasets enable the two experiments to perform unprecedented studies of heavy flavor hadron properties. We present recent D0 and CDF measurements, focusing on rare decays and CP violation in B-meson decays. Flavor Physics probes new phenomena by either searching for small deviations from the Standard Model (SM) based theoretical predictions or by measuring quantities which are highly suppressed within the SM. Searching for small deviations from the SM are performed using large strange, charm or bottom hadron samples, mostly by kaon experiments of B factories. Measurements of highly suppressed quantities, such as CP violation phases and asymmetries in the neutral B{sub s}-meson system or searches for rare B decays, are performed with the hope that new physics effects would be large enough to significantly affect the measured quantities and so, lead to observations of deviations from the SM expectations. The D0 and CDF detectors at the Fermilab Tevatron have each accumulated more that 9 fb{sup -1} of integrated luminosity. The corresponding large datasets enable the two experiments to perform unprecedented studies of heavy flavor hadron properties. We present recent D0 and CDF measurements, focusing on rare decays and CP violation in B-meson decays.

43 PARTICLE ACCELERATORS↗

A contactless approach for respiratory gating in PET using continuous-wave radar

Purpose: Respiratory gating is commonly used to reduce motion artifacts in positron emission tomography (PET). Clinically established methods for respiratory gating in PET require contact to the patient or a direct optical line between the sensor and the patient’s torso and time consuming preparation. In this work, a contactless method for capturing a respiratory signal during PET is presented based on continuous-wave radar. Methods: The proposed method relies on the principle of emitting an electromagnetic wave and detecting the phase shift of the reflected wave, modulated due to the respiratory movement of the patient’s torso. A 24 GHz carrier frequency was chosen allowing wave propagation through plastic and clothing with high reflections at the skin surface. A detector module and signal processing algorithms were developed to extract a quantitative respiratory signal. The sensor was validated using a high precision linear table. During volunteer measurements and [{sup 18}F] FDG PET scans, the radar sensor was positioned inside the scanner bore of a PET/computed tomography scanner. As reference, pressure belt (one volunteer), depth camera-based (two volunteers, two patients), and PET data-driven (six patients) signals were acquired simultaneously and the signal correlation was quantified. Results: The developed system demonstrated a high measurement accuracy for movement detection within the submillimeter range. With the proposed method, small displacements of 25 μm could be detected, not considerably influenced by clothing or blankets. From the patient studies, the extracted respiratory radar signals revealed high correlation (Pearson correlation coefficient) to those derived from the external pressure belt and depth camera signals (r = 0.69–0.99) and moderate correlation to those of the internal data-driven signals (r = 0.53–0.70). In some cases, a cardiac signal could be visualized, due to the representation of the mechanical heart motion on the skin. Conclusions: Accurate respiratory signals were obtained successfully by the proposed method with high spatial and temporal resolution. By working without contact and passing through clothing and blankets, this approach minimizes preparation time and increases the convenience of the patient during the scan.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Next Generation Muon g-2 Experiments

I report on the progress of two new muon anomalous magnetic moment experiments, which are in advanced design and construction phases. The goal of Fermilab E989 is to reduce the experimental uncertainty of $a_\mu$ from Brookhaven E821 by a factor of 4; that is, $\delta a_\mu \sim 16 \times 10^{-11}$, a relative uncertainty of 140~ppb. The method follows the same magic-momentum storage ring concept used at BNL, and pioneered previously at CERN, but muon beam preparation, storage ring internal hardware, field measuring equipment, and detector and electronics systems are all new or upgraded significantly. In contrast, J-PARC E34 will employ a novel approach based on injection of an ultra-cold, low-energy, muon beam injected into a small, but highly uniform magnet. Only a small magnetic focusing field is needed to maintain storage, which distinguishes it from CERN, BNL and Fermilab. E34 aims to roughly match the previous BNL precision in their Phase~1 installation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Inorganic Halide Perovskitoid TlPbI 3 for Ionizing Radiation Detection

Room temperature semiconductor detector (RTSD) materials for γ-ray and X-ray radiation are in great demand for the nonproliferation of nuclear materials as well as for biomedical imaging applications. Halide perovskites have attracted great attention as emerging and promising RTSD materials. In this contribution, the material synthesis, purification, crystal growth, crystal structure, photoluminescence properties, ionizing radiation detection performance, and electronic structure of the inorganic halide perovskitoid compound TlPbI 3 are reported on. This compound crystallizes in the ABX 3 non-perovskite crystal structure with a high density of d = 6.488 g·cm –3 , has a wide bandgap of 2.25 eV, and melts congruently at a low temperature of 360 °C without phase transitions, which allows for facile growth of high quality crystals with few thermally-activated defects. High-quality TlPbI 3 single crystals of centimeter-size are grown using the vertical Bridgman method using purified raw materials. A high electrical resistivity of ≈10 12 Ω·cm is readily obtainable, and detectors made of TlPbI 3 single crystals are highly photoresponsive to Ag K α X-rays (22.4 keV), and detects 122 keV γ-rays from 57 Co radiation source. The electron mobility-lifetime product µ e τ e was estimated at 1.8 × 10 –5 cm 2 ·V –1 . A high relative static dielectric constant of 35.0 indicates strong capability in screening carrier scattering and charged defects in TlPbI 3 .

36 MATERIALS SCIENCE↗

Analysis of the D+ --> K- pi+ e+ nu_e decay channel

Using 347.5 fb{sup -1} of data recorded by the BABAR detector at the PEP-II electron-positron collider, 244 x 10{sup 3} signal events for the D{sup +} {yields} K{sup -}{pi}{sup +}e{sup +}{nu}{sub e} decay channel are analyzed. This decay mode is dominated by the {bar K}*(892){sup 0} contribution. We determine the {bar K}*(892){sup 0} parameters: m{sub K*(892){sup 0}} = (895.4{+-}0.2{+-}0.2) MeV/c{sup 2}, {Lambda}{sub K*(892){sup 0}}{sup 0} = (46.5{+-}0.3{+-}0.2) MeV/c{sup 2} and the Blatt-Weisskopf parameter r{sub BW} = 2.1{+-}0.5{+-}0.5 (GeV/c){sup -1} where the first uncertainty comes from statistics and the second from systematic uncertainties. We also measure the parameters defining the corresponding hadronic form factors at q{sup 2} = 0 (r{sub V} = V(0)/A{sub 1}(0) = 1.463{+-}0.017{+-}0.031, r{sup 2} = A{sub 2}(0)/A{sub 1}(0) = 0.801{+-}0.020{+-}0.020) and the value of the axial-vector pole mass parameterizing the q{sup 2} variation of A{sub 1} and A{sub 2}: m{sub A} = (2.63{+-}0.10{+-}0.13) GeV/c{sup 2}. The S-wave fraction is equal to (5.79{+-}0.16{+-}0.15)%. Other signal components correspond to fractions below 1%. Using the D{sup +} {yields} K{sup -}{pi}{sup +}{pi}{sup +} channel as a normalization, we measure the D{sup +} semileptonic branching fraction: {Beta}(D{sup +} {yields} K{sup -}{pi}{sup +}e{sup +}{nu}{sub e}) = (4.00 {+-} 0.03 {+-} 0.04 {+-} 0.09) x 10{sup -2} where the third uncertainty comes from external inputs. We then obtain the value of the hadronic form factor A{sub 1} at q{sup 2} = 0: A{sub 1}(0) = 0.6200 {+-} 0.0056 {+-} 0.0065 {+-} 0.0071. Fixing the P-wave parameters we measure the phase of the S-wave for several values of the K{pi} mass. These results confirm those obtained with K{pi} production at small momentum transfer in fixed target experiments.

79 ASTRONOMY AND ASTROPHYSICS↗

General Failure Modes and Effects Analysis for Accelerator and Detector Magnet Design at JLab

The aim of this article is to develop a risk management procedure, which could be applied to the magnet design process, for both superconducting and normal magnets at the Jefferson Laboratory (JLab). This procedure allowed us to identify the key risks at each of the critical phases of design and propose procedures, tests, and checks to mitigate each risk. In this article, we present a qualitative and quantitative risk management procedure commonly referred to a “failure modes and effects analysis.” As part of this procedure, we calculated a risk priority number (RPN) for each activity of the process, identified the most critical activities and proposed mitigation activities, which in turn resulted in a revised RPN. Additionally, another benefit of this procedure was the identification of appropriate “control and hold” points within the design process, which allowed one to review and approve a particular outcome before proceeding to the next sequential activity.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

First model-independent Dalitz analysis of B 0 → DK* 0 , D→K$^{0}_{S}$π + π – decay

We report a measurement of the amplitude ratio r S of B 0 → D 0 K* 0 and B 0 → D 0 ¯K* 0 decays with a Dalitz analysis of D → K$^{0}_{S}$π + π – decays, for the first time using a model-independent method. We set an upper limit rS<0.87 at the 68\% confidence level, using the full data sample of 772×10 6 BB¯ pairs collected at the Υ(4S) resonance with the Belle detector at the KEKB e + e – collider. This result is obtained from observables x–= +0.4$^{+1.0+0.0}_{–0.6–0.1}$ ± 0.0, y– = –0.6$^{+0.8+0.1}_{–1.0–0.0}$ ± 0.1, x + = +0.1$^{+0.7+0.0}_{–0.4–0.1}$ ± 0.1 and y + = +0.3$^{+0.5+0.0}_{–0.8–0.1}$ ± 0.1, where x ± = r S cos(δ S ± Φ 3 ), y ± = r S sin(δ S ± Φ 3 ) and Φ 3 (δ S ) is the weak (strong) phase difference between B 0 → D 0 K* 0 and B 0 → D¯ 0 K* 0 .

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Focal construct geometry for high intensity energy dispersive x-ray diffraction based on x-ray capillary optics

We presented a focal construct geometry (FCG) method for high intensity energy dispersive X-ray diffraction by utilizing a home-made ellipsoidal single-bounce capillary (ESBC) and a polycapillary parallel X-ray lens (PPXRL). The ESBC was employed to focus the X-rays from a conventional laboratory source into a small focal spot and to produce an annular X-ray beam in the far-field. Additionally, diffracted polychromatic X-rays were confocally collected by the PPXRL attached to a stationary energy-resolved detector. Our FCG method based on ESBC and PPXRL had achieved relatively high intensity diffraction peaks and effectively narrowed the diffraction peak width which was helpful in improving the potential d-spacing resolution for material phase analysis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Prospects for GRB science with the Fermi Large Area Telescope

The Large Area Telescope (LAT) instrument on the Fermi mission will reveal the rich spectral and temporal gamma-ray burst (GRB) phenomena in the >100 MeV band. The synergy with Fermi 's Gamma-ray Burst Monitor detectors will link these observations to those in the well explored 10-1000 keV range; the addition of the >100 MeV band observations will resolve theoretical uncertainties about burst emission in both the prompt and afterglow phases. Trigger algorithms will be applied to the LAT data both onboard the spacecraft and on the ground. Furthermore, the sensitivity of these triggers will differ because of the available computing resources onboard and on the ground. Here we present the LAT's burst detection methodologies and the instrument's GRB capabilities.

79 ASTRONOMY AND ASTROPHYSICS↗

PROSPECTS FOR GRB SCIENCE WITH THE FERMI LARGE AREA TELESCOPE

The Large Area Telescope (LAT) instrument on the Fermi mission will reveal the rich spectral and temporal gamma-ray burst (GRB) phenomena in the >100 MeV band. The synergy with Fermi's Gamma-ray Burst Monitor detectors will link these observations to those in the well explored 10-1000 keV range; the addition of the >100 MeV band observations will resolve theoretical uncertainties about burst emission in both the prompt and afterglow phases. Trigger algorithms will be applied to the LAT data both onboard the spacecraft and on the ground. The sensitivity of these triggers will differ because of the available computing resources onboard and on the ground. Here we present the LAT's burst detection methodologies and the instrument's GRB capabilities.

79 ASTRONOMY AND ASTROPHYSICS↗

Using a primordial gravitational wave background to illuminate new physics

A primordial spectrum of gravitational waves serves as a backlight to the relativistic degrees of freedom of the cosmological fluid. Any change in the particle physics content, due to a change of phase or freeze-out of a species, will leave a characteristic imprint on an otherwise featureless primordial spectrum of gravitational waves and indicate its early-Universe provenance. Here, we show that a gravitational wave detector such as the Laser Interferometer Space Antenna would be sensitive to physics near 100 TeV in the presence of a sufficiently strong primordial spectrum. Such a detection could complement searches at newly proposed 100 km circumference accelerators such as the Future Circular Collider at CERN and the Super Proton-Proton Collider in China, thereby providing insight into a host of beyond standard model issues, including the hierarchy problem, dark matter, and baryogenesis.

79 ASTRONOMY AND ASTROPHYSICS↗

First nuclear ultraheavy dark matter search in argon time projection chambers with the DarkSide-50 experiment

We report on the first search for nuclear ultraheavy dark matter (UHDM) in a dual-phase liquid argon time projection chamber using the DarkSide-50 experiment. Unlike conventional weakly interacting massive particles, a nuclear UHDM model may be composed of many dark nucleons and scatter numerous times while passing through the detector. Accounting for energy loss through the Earth’s overburden, we apply selection criteria optimized for multiscatter event topologies using the 532-day low-radiation campaign of the DarkSide-50 detector. Excluded limits on the UHDM-nucleon scattering cross section for dark nucleon masses of m χ = 10 , 50 , 100 , 500 GeV / c 2 are presented.

Agnes, P. [GSSI, Aquila; Gran Sasso]↗