Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Oxidation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,405 records · Page 78

233 U oxide Measurement Campaign Data: Passive and Active Neutron Multiplicity Measurements of Uranium Oxide Samples at Oak Ridge National Laboratory

During FY2023, three measurement campaigns were conducted at Oak Ridge National Laboratory. The goal was to quantify the neutron signatures of samples of uranium oxide containing uranium 233 and uranium-235. This report presents the neutron multiplicity data obtained using the large volume active well coincidence counter (LV-AWCC).

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Mechanisms of Water-Stimulated Mg 2+ Intercalation in Vanadium Oxide: Toward the Development of Hydrated Vanadium Oxide Cathodes for Mg Batteries

As lithium-ion batteries approach their theoretical limits for energy density, magnesium-ion batteries are emerging as a promising next-generation energy storage technology. However, progress in magnesium-ion battery research has been stymied by a lack of available high capacity cathode materials that can reversibly insert magnesium ions. Vanadium Oxide (V 2 O 5 ) has emerged as one of the more promising candidate cathode materials, owing to its high theoretical capacity, facile synthesis methods, and relatively high operating voltage. This review focuses on the outlook of hydrated V 2 O 5 structures as a high capacity cathode material for magnesium-ion batteries. In general, V 2 O 5 structures exhibit poor experimental capacity for magnesium-ion insertion due to sluggish magnesium-ion insertion kinetics and poor electronic conductivity. However, several decades ago, it was discovered that the addition of water to organic electrolytes significantly improves magnesium-ion insertion into V 2 O 5 . This review clarifies the various mechanisms that have been used to explain this observation, from charge shielding to proton insertion, and offers an alternative explanation that examines the possible role of structural hydroxyl groups on the V 2 O 5 surface. While the mechanism still needs to be further studied, this discovery fueled new research into V 2 O 5 electrodes that incorporate water directly as a structural element. The most promising of these hydrated V 2 O 5 materials, many of which incorporate conductive additives, nanostructured architectures, and thin film morphologies, are discussed. Ultimately, however, these hydrated V 2 O 5 structures still face a significant barrier to potential applications in magnesium-ion batteries. During full cell electrochemical cycling, these hydrated structures tend to leach water into the electrolyte and passivate the surface of the magnesium anode, leading to poor cycle life and low capacity retention. Recently, some promising strides have been made to remedy this problem, including the use of artificial solid electrolyte interphase layers as an anode protection scheme, but a call to action for more anode protection strategies that are compatible with trace water and magnesium metal is required.

25 ENERGY STORAGE↗

High-pressure crystal growth and magnetic and electrical properties of the quasi-one dimensional osmium oxide Na{sub 2}OsO{sub 4}

Na{sub 2}OsO{sub 4} crystals were grown by a NaCl flux method under high pressure. It crystallizes in the Ca{sub 2}IrO{sub 4}-type structure without having additional elements or metal vacancies, which are usually accommodated. It appears that Na{sub 2}OsO{sub 4} is a metal-stoichiometric Ca{sub 2}IrO{sub 4}-type compound never been synthesized to date. Na{sub 2}OsO{sub 4} has the octahedral environment of Os{sup 6+}O{sub 6} so that the electronic configuration is 5d{sup 2}, suggesting the magnetic S=1 ground state. However, magnetization, electrical resistivity, and specific heat measurements indicated that the non-magnetic S=0 state is much likely for Na{sub 2}OsO{sub 4} than the S=1 state. Band structure calculations and the structure analysis found that the disagreement is probably due to the statically uniaxial compression of the OsO{sub 6} octahedra, resulting in splitting of the t{sub 2{sub g}} band. - Graphical abstract: Na{sub 2}OsO{sub 4} crystals were grown by a NaCl flux method under high pressure. It crystallizes in the Ca{sub 2}IrO{sub 4}-type structure comprising infinite Os{sup 6+}O{sub 6} octahedra (5d{sup 2}) chains. The crystal growth, the crystal structure, and the magnetic and electrical properties are reported.

36 MATERIALS SCIENCE↗

Electrochemical Stiffness Changes in Lithium Manganese Oxide Electrodes

In situ strain and stress measurements are performed on composite electrodes to monitor potential‐dependent stiffness changes in lithium manganese oxide (LiMn 2 O 4 ). Lithium insertion and removal results in asynchronous strain and stress generation in the electrode. Electrochemical stiffness changes are calculated by combining coordinated stress and strain measurements. The electrode experiences dramatic changes in electrochemical stiffness due to potential‐dependent Li + ion intercalation mechanisms. The development of stress in the early stages of delithiation (at ≈3.95 V) due to a kinetic barrier at the electrode surface gives rise to stiffness changes in the electrode. Strain generation due to phase transformations reduces stiffness in the electrode at 4.17 V during delithiation and at 4.11 V during lithiation. During lithiation, stress generation due to Coulombic repulsions between occupied and incoming Li + ions leads to stiffening of the electrode at 3.96 V. The electrode also experiences greater changes in stiffness during delithiation compared to lithiation. These changes in electrochemical stiffness provide insight into the interplay between mechanical and electrochemical properties which control electrode response to lithiation and delithiation.

Çapraz, Ömer Özgür↗

Dioxygen activation by non-adiabatic oxidative addition to a single metal center [O 2 activation by non-adiabatic oxidative addition to a single metal center]

A chromium(I) dinitrogen complex reacts rapidly with O 2 to form the mononuclear dioxo complex [Tp tBu,Me Cr V (O) 2 ] (Tp tBu,Me =hydrotris(3- tert -butyl-5-methylpyrazolyl)borate), whereas the analogous reaction with sulfur stops at the persulfido complex [Tp tBu,Me Cr III (S 2 )]. The transformation of the putative peroxo intermediate [Tp tBu,Me Cr III (O 2 )] (S= 3 / 2 ) into [Tp tBu,Me Cr V (O) 2 ] (S= 1 / 2 ) is spin-forbidden. The minimum-energy crossing point for the two potential energy surfaces has been identified. Finally, although the dinuclear complex [(Tp tBu,Me Cr) 2 (μ-O) 2 ] exists, mechanistic experiments suggest that O 2 activation occurs on a single metal center, by an oxidative addition on the quartet surface followed by crossover to the doublet surface.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

In situ liquid SIMS analysis of uranium oxide

Trace analysis of nuclear materials in solid particles collected in the environment or particles in liquid slurry generated in nuclear material manufacturing processes can pinpoint elemental, organic, and isotopic signatures of nuclear fuel cycle activities and processes. Such information can support nuclear safeguards programs by increasing our ability to detect undeclared nuclear materials, routine activities for safeguarding at declared facilities, and illicit activities. However, trace radioactive material analysis in liquids and slurries is challenging using bulk approaches. For example, one drawback of sensitive analysis such as inductively coupled plasma mass spectrometry (ICP-MS) is that sample is consumed or destroyed as a result of the technical approach. We developed a vacuum compatible microfluidic interface to enable surface analysis of liquids and liquid-solid interactions using time-of-flight secondary ion mass spectrometry (ToF-SIMS). In this work, we illustrate initial results of liquid standards containing uranium using in situ liquid SIMS. Specifically a series of diluted uranium standards used for ICPMS analysis were studied and the limit of detection was estimated. Since the liquid SIMS analysis is almost nondestructive, the same sample can be analyzed by other more destructive approaches afterwards or saved for future references. Consequently, multimodal analysis is possible. Our results demonstrate that in situ liquid SIMS can be used as a new approach to analyze radioactive materials in liquid and slurry forms of relevance to the IAEA safeguards missions.

In situ liquid ToF-SIMS, uranium, limit of detecti↗

Comparison of Different Ion Mobility Setups Using Poly (Ethylene Oxide) PEO Polymers: Drift Tube, TIMS, and T-Wave Comparison of Different Ion Mobility Setups Using Poly (Ethylene Oxide) PEO Polymers: Drift Tube, TIMS, and T-Wave

Over the years, polymer analyses using ion mobility-mass spectrometry (IM-MS) measurements have been performed on different ion mobility spectrometry (IMS) setups. In order to be able to compare literature data taken on different IM(-MS) instruments, ion heating and ion temperature evaluations have already been explored. Nevertheless, extrapolations to other analytes are difficult and thus straightforward same-sample instrument comparisons seem to be the only reliable way to make sure that the different IM(-MS) setups do not greatly change the gas-phase behavior. We used a large range of degrees of polymerization (DP) of poly(ethylene oxide) PEO homopolymers to measure IMS drift times on three different IM-MS setups: a homemade drift tube (DT), a trapped (TIMS), and a traveling wave (T-Wave) IMS setup. The drift time evolutions were followed for increasing polymer DPs (masses) and charge states, and they are found to be comparable and reproducible on the three instruments. .

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗