Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Optics and Optical Instruments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,405 records · Page 78

The Octopus processor for the CMS L1 muon trigger for High Luminosity LHC

The upgraded L1 muon trigger system of the CMS experiment in the High Luminosity Large Hadron Collider is based on custom processors featuring large Field Programmable Gate Arrays (FPGAs) connected by large numbers of optical links. These provide the I/O bandwidth and power necessary to process the complex algorithms used during the collection of physics data. The design and performance requirements of these processors creates significant challenges in signal integrity, power delivery, and thermal management. In this paper we describe the Octopus processor, featuring a large Xilinx Virtex Ultrascale+ FPGA and up to 128 links interfaced to optics through high quality twin-ax copper cables. Results on signal integrity at 25 Gb/s and the first demonstration of 50+ Gb/s links with pluggable optics in CMS are also shown, demonstrating bit error rates below 10 –15 at a 95% confidence level. The thermal performance is measured inside an Advanced-TCA crate with acceptable thermal margins up to 200 W of chip power. Future improvements are mentioned, potentially allowing operation at up to 300 W.

Instruments & Instrumentation↗

Cosmological preference for a negative neutrino mass

The most precise determination of the sum of neutrino masses from cosmological data, derived from analysis of the cosmic microwave background (CMB) and baryon acoustic acoustic oscillations (BAO) from the Dark Energy Spectroscopic Instrument (DESI), favors a value below the minimum inferred from neutrino flavor oscillation experiments. We explore which data is most responsible of this puzzling aspect of the current constraints on neutrino mass and whether it is related to other anomalies in cosmology. We demonstrate conclusively that the preference for negative neutrino masses is a consequence of larger than expected lensing of the CMB in both the two- and four-point lensing statistics. Furthermore, we show that this preference is robust to changes in likelihoods of the BAO and CMB optical depth analyses given the available data. We then show that this excess clustering is not easily explained by changes to the expansion history and is likely distinct from the preference for for dynamical dark energy in DESI BAO data. Finally, we discuss how future data may impact these results, including an analysis of Planck CMB with mock DESI 5-year data. Here, we conclude that the negative neutrino mass preference is likely to persist even as more cosmological data is collected in the near future.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

DeepZipper: A Novel Deep-learning Architecture for Lensed Supernovae Identification

Large-scale astronomical surveys have the potential to capture data on large numbers of strongly gravitationally lensed supernovae (LSNe). To facilitate timely analysis and spectroscopic follow-up before the supernova fades, an LSN needs to be identified soon after it begins. To quickly identify LSNe in optical survey data sets, we designed ZipperNet, a multibranch deep neural network that combines convolutional layers (traditionally used for images) with long short-term memory layers (traditionally used for time series). We tested ZipperNet on the task of classifying objects from four categories—no lens, galaxy-galaxy lens, lensed Type-Ia supernova, lensed core-collapse supernova—within high-fidelity simulations of three cosmic survey data sets: the Dark Energy Survey, Rubin Observatory’s Legacy Survey of Space and Time (LSST), and a Dark Energy Spectroscopic Instrument (DESI) imaging survey. Among our results, we find that for the LSST-like data set, ZipperNet classifies LSNe with a receiver operating characteristic area under the curve of 0.97, predicts the spectroscopic type of the lensed supernovae with 79% accuracy, and demonstrates similarly high performance for LSNe 1–2 epochs after first detection. We anticipate that a model like ZipperNet, which simultaneously incorporates spatial and temporal information, can play a significant role in the rapid identification of lensed transient systems in cosmic survey experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Observation of Undulator Radiation Generated by a Single Electron Circulating in a Storage Ring and Possible Applications

An experimental study into the undulator radiation, generated by a single electron was carried out at the Integrable Optics Test Accelerator (IOTA) storage ring at Fermilab. The individual photons were detected by a Single Photon Avalanche Diode (SPAD) at an average rate of 1 detection per 300 revolutions in the ring. The detection events were continuously recorded by a picosecond event timer for as long as 1 minute at a time. The collected data were used to test if there is any deviation from the classically predicted Poissonian photostatistics. It was motivated by the observation * of sub-Poissonian statistics in a similar experiment. The observation * could be an instrumentation effect related to low detection efficiency and long detector dead time. In our experiment, the detector (SPAD) has a much higher efficiency (65%) and a much lower dead time. In addition, we show that the collected data (recorded detection times) can be used to study the synchrotron motion of a single electron and infer some parameters of the ring. For example, by comparing the results of simulation and measurement for the synchrotron motion we were able to estimate the magnitude of the RF phase jitter.

43 PARTICLE ACCELERATORS↗

Experimental Report: Multi-Instrument Comparison of AAF Condensation Particle Counters

Condensation particle counters (CPCs), also known as condensation nucleus counters (CNCs) are sophisticated instruments designed to measure the concentration of aerosol particles in the atmosphere. These devices are pivotal in environmental monitoring, industrial applications, and scientific research, particularly in atmospheric studies. CPCs are vital for understanding the role of aerosols in climate systems. Aerosols influence cloud formation, radiative forcing, and atmospheric chemistry. By providing accurate measurements of particle concentrations and distributions, CPCs contribute to models that predict atmospheric impact and weather patterns (Mei et al. 2021). CPCs operate by enlarging submicron particles, including those as small as a few nanometers, to sizes detectable by optical methods. This report delves into the mechanisms, importance, and contributions of CPCs to atmospheric research at the U.S. Department of Energy Atmospheric Radiation Measurement (ARM) Aerial Facility (AAF), highlighting their role in advancing air quality assessment, pollution control, and atmospheric studies.

54 ENVIRONMENTAL SCIENCES↗

Near-infrared Census of RR Lyrae Variables in the Messier 3 Globular Cluster and the Period–Luminosity Relations

We present new near-infrared (NIR), JHK {sub s}, time-series observations of RR Lyrae variables in the Messier 3 (NGC 5272) globular cluster using the WIRCam instrument at the 3.6 m Canada–France–Hawaii Telescope. Our observations cover a sky area of ∼21′ × 21′ around the cluster center and provide an average of 20 epochs of homogeneous JHK {sub s}-band photometry. New homogeneous photometry is used to estimate robust mean magnitudes for 175 fundamental-mode (RRab), 47 overtone-mode (RRc), and 11 mixed-mode (RRd) variables. Our sample of 233 RR Lyrae variables is the largest thus far obtained in a single cluster with time-resolved, multiband NIR photometry. NIR-to-optical amplitude ratios for RR Lyrae in Messier 3 exhibit a systematic increase moving from RRc to short-period (P < 0.6 day) and long-period (P ≳ 0.6 day) RRab variables. We derive JHK {sub s}-band period–luminosity relations for RRab, RRc, and the combined sample of variables. Absolute calibrations based on the theoretically predicted period–luminosity–metallicity relations for RR Lyrae stars yield a distance modulus, μ=15.041±0.017 (statistical)±0.036 (systematic) mag, to Messier 3. When anchored to trigonometric parallaxes for nearby RR Lyrae stars from the Hubble Space Telescope and the Gaia mission, our distance estimates are consistent with those resulting from the theoretical calibrations, albeit with relatively larger systematic uncertainties.

79 ASTRONOMY AND ASTROPHYSICS↗

Spectral and temporal shaping of spectrally incoherent pulses in the infrared and ultraviolet

Laser–plasma instabilities (LPIs) hinder the interaction of high-energy laser pulses with targets. Simulations show that broadband spectrally incoherent pulses can mitigate these instabilities. Optimizing laser operation and target interaction requires controlling the properties of these optical pulses. We demonstrate closed-loop control of the spectral density and pulse shape of nanosecond spectrally incoherent pulses after optical parametric amplification in the infrared (∼1053 nm) and sum–frequency generation to the ultraviolet (∼351 nm) using spectral and temporal modulation in the fiber front end. The high versatility of the demonstrated approaches can support the generation of high-energy, spectrally incoherent pulses by future laser facilities for improved LPI mitigation.

47 OTHER INSTRUMENTATION↗

Resolving the Radio Emission from the Quasar P172+18 at z = 6.82

We present high angular resolution imaging of the quasar PSO J172.3556+18.7734 at z = 6.82 with the Very Long Baseline Array (VLBA). This source currently holds the record of being the highest redshift radio-loud quasar. These observations reveal a dominant radio source with a flux density of 398.4 ± 61.4 μJy at 1.53 GHz, a deconvolved size of 9.9 × 3.5 mas (52.5 × 18.6 pc), and an intrinsic brightness temperature of (4.7 ± 0.7) × 10{sup 7} K. A weak unresolved radio extension from the main source is also detected at the ∼3.1σ level. The total flux density recovered with the VLBA at 1.53 GHz is consistent with that measured with the Very Large Array (VLA) at a similar frequency. The quasar is not detected at 4.67 GHz with the VLBA, suggesting a steep spectral index with a limit of α{sub 4.67}{sup 1.53}<−1.55. The quasar is also not detected with the VLBA at 7.67 GHz. The overall characteristics of the quasar suggest that it is a very young radio source similar to lower redshift gigahertz peaked spectrum radio sources, with an estimated kinematic age of ∼10{sup 3} yr. The VLA observations of this quasar revealed a second radio source in the field 23.″1 away. This radio source, which does not have an optical or IR counterpart, is not detected with the VLBA at any of the observed frequencies. Its nondetection at the lowest observed VLBA frequency suggests that it is resolved out, implying a size larger than ∼0.″17. It is thus likely situated at lower redshift than the quasar.

47 OTHER INSTRUMENTATION↗

Modeling and Proof-of-Concept of a Blackbody-Based Calibration Method in the InfraBREAD Detector

The Broadband Reflector Experiment for Axion Detection (BREAD) is an ongoing collaboration searching for the conversion of yet undiscovered axion-like dark matter particles to photons in the presence of a magnetic field. InfraBREAD, a pilot experiment realization of BREAD, uses a superconducting nanowire single photon detector (SNSPD), a high-efficiency and low-noise device, to specifically detect infrared-range photons produced by $\mathcal{O}$(eV) axion-like particles. The unique BREAD coaxial reflector setup allows for the focusing of converted signal photons to a 1mm $\times$ 1mm SNSPD. However, when the detector is cooled to cryogenic temperatures during operation, uneven thermal contraction of reflector components may lead to a small shift in the location of the focal spot. A novel calibration method using blackbody radiation is proposed to locate the true focal spot of the detector \textit{in situ}. Through ray tracing simulations done in FRED Optical Engineering Software, this method is demonstrated to locate the focus to within $\SI{50}{\micro\metre}$ in the axial dimension. Additionally, it is demonstrated that the blackbody photon source used in this calibration must be at a temperature of at least $\SI{15}{\kelvin}$ to $\SI{40}{\kelvin}$, depending on the sensitivity of the SNSPD.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance of microchannel plate based detectors for <25 keV x rays: Monte Carlo simulations and comparisons with experimental results

We present the results of Monte Carlo simulations of the microchannel plate (MCP) response to x rays in the 250 eV to 25 keV energy range as a function of both x-ray energy and impact angle and their comparisons with the experimental results from the X8A beamline at the National Synchrotron Light Source at Brookhaven National Laboratory. Incoming x rays interact with the lead glass of the microchannel plate, producing photoelectrons. Transport of the photoelectrons is neglected in this model, and it is assumed that photoelectrons deposit all their energy at the point they are created. This deposition leads to the generation of many secondary electrons, some fraction of which diffuse to the MCP pore surface where they can initiate secondary electron cascades in the pore under an external voltage bias. X-ray penetration through multiple MCP pore walls is increasingly important above 5 keV, and the effect of this penetration on MCP performance is studied. In agreement with past measurements, we find that the dependence of MCP sensitivity with angle relative to the pore bias changes from a cotangent dependence to angular independence and then proceeds to a secant dependence as the x-ray energy increases. We also find that with the increasing x-ray energy, the MCP gain sensitivity as a function of bias voltage decreases. The simulations also demonstrate that for x rays incident normal to the MCP surface, spatial resolution shows little dependence on the x-ray energy but degrades with the increasing x-ray energy as the angle of incidence relative to the surface normal increases. This agrees with experimental measurements. Simulation studies have also been completed for MCPs gated with a subnanosecond voltage pulse. In this work, we find that the optical gate profile width increases as the x-ray energy is increased above 5 keV, a consequence of increased x-ray penetration at energies >5 keV. Simulations of the pulsed dynamic range show that the dynamic range varies between ~100 and 1000 depending on x-ray energy and peak voltage.

47 OTHER INSTRUMENTATION↗

Bragg grating inscription in photosensitive materials by an optical replication process

This paper examines the feasibility of producing multiplexed Bragg gratings for use as diffractive optical elements (DOEs) by coherent optical replication of a surface-relief phase grating into thick-film photosensitive materials. The use of such DOEs in light guide plates (LGPs) for optical imaging systems ensures energy-efficient light input into and output from LGPs and allows one to minimise their weight and size. We present simulation results for the interference structure fabrication process and recording of a series of multiplexed diffraction gratings in photosensitive materials. (paper)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Defect modeling in semiconductors: the role of first principles simulations and machine learning

Abstract Point defects in semiconductors dictate their electronic and optical properties. Vacancies, interstitials, substitutional defects, and defect complexes can form in the semiconductor lattice and significantly impact its performance in applications such as solar absorption, light emission, electronics, and catalysis. Understanding the nature and energetics of point defects is essential for the design and optimization of next-generation semiconductor technologies. Here, we provide a comprehensive overview of the current state of research on point defects in semiconductors, focusing on the application of density functional theory (DFT) and machine learning (ML) in accelerating the prediction and understanding of defect properties. DFT has been instrumental in accurately calculating defect formation energies, charge transition levels, and other defect-related properties such as carrier recombination rates and lifetimes, and ion migration barriers. ML techniques, particularly neural networks, have emerged as powerful tools for enabling rapid prediction of defect properties at DFT-accuracy in order to overcome the expense of using large supercells and advanced functionals. We begin this article with a discussion of different types of point defects and complexes, their impact on semiconductor properties, and the experimental and DFT approaches typically used for their characterization. Through multiple case studies, we explore how DFT has been successfully applied to understand defect behavior across a variety of semiconductors, and how ML approaches integrated with DFT can efficiently predict defect properties and facilitate the discovery of new materials with tailored defect behavior. Overall, the advent of ‘DFT+ML’ promises to drive advancements in semiconductor technology, catalysis, and renewable energy applications, paving the way for the development of high-performance semiconductors which are defect-tolerant or have desirable dopability.

Rahman, Md Habibur (ORCID:000000027705984X)↗

Improved Throughput and Analysis of Scratch Test Results via Automation and Machine Learning

A data analysis automation interface that incorporates machine learning (ML) has been developed to improve productivity, efficiency, and consistency in identifying and defining critical load values (or other values associated with optically identifiable characteristics) of a coating when a scratch test is performed. In this specific program, the machine learning component of the program has been trained to identify the Critical Load 2 (L C2 ) value by analyzing images of the scratch tracks created in each test. An optical examination of the scratch by a human operator is currently used to determine where this value occurs. However, the vagueness of the standard has led to varying interpretations and nonuniform usage by different operators at different laboratories where the test is implemented, resulting in multiple definitions of the desired parameter. Using a standard set of training and validation images to create the dataset, the critical load can be identified consistently amongst different laboratories using the automation interface without requiring the training of human operators. When the model was used in conjunction with an instrument manufacturer's scratch test software, the model produced accurate and repeatable results and defined L C2 values in as little as half of the time compared to a human operator. When combined with a program that automates other aspects of the scratch testing process usually conducted by a human operator, scratch testing and analysis can occur with little to no intervention from a human beyond initial setup and frees them to complete other work in the lab.

36 MATERIALS SCIENCE↗

Using sub-limb observations to measure gravity waves excited by convection

Convective gravity waves are a major driver of atmospheric circulation, including the stratospheric and mesospheric quasi-biennial oscillation (QBO) and the Brewer–Dobson circulation. Previous work shows clear evidence that these waves can be excited by both single convective cells and by mesoscale convective complexes acting as a single unit. However, the partitioning of the generated waves and, crucially for atmospheric model development, the flux of momentum they transport between these two types of excitation process remains highly uncertain due to a fundamental lack of suitable observations at the global scale. Here, we use both theoretical calculations and sampled output from a high-resolution weather model to demonstrate that a satellite instrument using a sub-limb geometry would be well suited to characterising the short-vertical short-horizontal gravity waves these systems produce, and hence to provide the scientific knowledge needed to identify the relative wave-driving contribution of these two types of convective wave excitation.

54 ENVIRONMENTAL SCIENCES↗

Pulse shape measurements for neutron/gamma discrimination using the TOFPET2 ASIC

Many highly pixelated organic scintillator detection systems would benefit from independent readout of each scintillator pixel. Recent advances in Silicon Photomultiplier (SiPM) technology makes this goal feasible, however the data acquisition from potentially hundreds or thousands of channels requires a low-cost and compact solution. For pixelated neutron detection with organic scintillators, the capability to distinguish between neutron and gamma interactions using Pulse Shape Discrimination (PSD) is required along with pulse charge and time of arrival. The TOFPET2 ASIC from PETsys Electronics is a 64-channel readout chip providing pulse time and charge integration measurements from SiPMs, and is specifically designed for time-of-flight positron-emission tomography. Using an 8 × 8 array of 6 mm × 6 mm J-series SiPMs from SensL/OnSemi (ArrayJ-60035-64P-PCB), we have studied the energy and PSD performance of the TOFPET2 ASIC using a 4 × 4 array of 6 mm × 6 mm × 30 mm trans -Stilbene crystals from Inrad Optics and a custom SiPM routing board from PETsys Electronics. In conclusion, using a time-over-threshold method, we measure a maximum PSD figure-of-merit of approximately 1.2 at 478 keV (the Compton edge of 662 keV) for a J-series SiPM operating at an over-voltage of 3V.

47 OTHER INSTRUMENTATION↗

Multichannel angular spectrometer

A multichannel angular spectrometer includes an array of fiber pickups having an arcuate arrangement and focused about a sample volume. A broadband light source is configured to illuminate a sample within the sample volume. At least one dispersion element is in optical communication with the array of fiber pickups. An imaging sensor is in optical communication with the array of fiber pickups. The imaging sensor is configured to image the broadband light received by the array of fiber pickups and dispersed by the at least one dispersion element. A processor is in electrical communication with the imaging sensor. The processor has a power supply and computer-readable memory.

47 OTHER INSTRUMENTATION↗

Measurement of the liquid argon scintillation pulse shape using differentiable simulation in the coherent CAPTAIN-Mills experiment

The coherent CAPTAIN-Mills (CCM) experiment is a liquid argon (LAr) light collection detector searching for MeV-scale neutrino and beyond Standard Model physics signatures. Two hundred eight-inch photomultiplier tubes instrument the seven-ton fiducial volume with 50% photocathode coverage to detect light produced by charged particles. CCM’s light-based approach reduces requirements of LAr purity, compared to other detection technologies, such that sub-MeV particles can be reliably detected without additional LAr filtration and with 𝒪⁡(1) parts per million of common contaminants. We present a measurement of LAr light production and propagation parameters, with uncertainties, obtained from a sample of MeV-scale electromagnetic events. The optimization of this high-dimensional parameter space was facilitated by a differentiable optical photon Monte Carlo simulation and detailed photomultiplier tube response characterization. This result accurately predicts the timing and spatial distribution of light due to scintillation and Cherenkov emission in the detector. This is the first description of photon propagation in LAr to include several effects, including anomalous dispersion of the index of refraction near the ultraviolet resonance, Mie scattering from impurities, and Cherenkov light production.

Cherenkov detectors↗

Deployment of POLARBEAR-2b

POLARBEAR-2b (PB-2b) is the second receiver in the Simons Array, a cosmic microwave background (CMB) polarization experiment. The Simons Array uses dichroic polarization sensitive lenslet-coupled sinuous antennas and transition-edge sensor (TES) bolometers made of superconducting films. These bolometers are read out with frequency multiplexing electronics. PB-2b contains ~7500 detectors in two bands at 90 and 150 GHz with arcminute resolution. The polarization of these detectors is modulated by a cryogenic continuously rotating half-wave plate. PB-2b was installed on its telescope in 2022 in the Atacama Desert at an altitude of 5.2 km. This paper will detail initial readout commissioning, test of a new loopgain monitoring method, and focusing the optics. Work is ongoing to commission the remaining ambient temperature readout electronics, measure detector time constants, and observe with the cryogenic half-wave plate spinning.

47 OTHER INSTRUMENTATION↗