Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Multiplex”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,405 records · Page 78

A framework for quantitative analysis of spectral data in two channels

Simultaneous acquisition of emission intensity from two channels in dual-color fluorescence measurements can be used to determine the spectral properties of an emitter. We detail a method to extract quantitative information from dual-color measurements by considering two models: a single spectral component model for peak wavelength determination and a dual spectral component model for relative strength determination. The former model is useful for spectral characterization and establishing heterogeneity within an emitter species, while the latter model is useful for analyzing energy transfer efficiency. Both models are formalized to yield probability distributions that reflect uncertainties due to shot noise. We applied these analysis tools to single-particle measurements of CdSe/CdS quantum dots. Isolated emitters had narrow spectral-intensity distributions that reflected their static emission profiles and fluorescence stability. Small assemblies of mixed donor/acceptor particles exhibited dynamic behavior where emission configuration changes reveal different spectral characteristics due to energy transfer.

36 MATERIALS SCIENCE↗

Direct experimental measurement of SRS-induced spectral tilt in multichannel multispan communication systems

Nonlinear SRS-induced tilt of the spectrum of a multichannel DWDM signal is studied experimentally in standard singlemode fibreoptic communication lines. It is found that at a fixed spectral bandwidth and total power the nonlinear SRS tilt is independent of the number of channels, radiation source type, and the initial tilt (positive or negative). In a multispan line consisting of identical spans the total nonlinear tilt of the spectrum (in dB) is proportional to the number of spans, spectral width and total power. (optical fibres, lasers and amplifiers. properties and applications)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Experimental study and numerical modelling of a 3 × 100G DP-QPSK superchannel

Crosstalk effects are studied experimentally in a DWDM line with 100G DP-QPSK channels at a frequency convergence of the channels (three channels with a frequency separation of 50, 37.5 and 33 GHz) in the C-band. Spans of 100 km in length are used, with the number of spans varying from one to six. The required optical signal-to-noise ratio (OSNR{sub R}) is determined experimentally for a different number of spans, interchannel intervals and input power. We propose a theoretical model based on the numerical modelling that describes the influence of adjacent channels at a strong convergence. The model is calibrated using the obtained experimental data. Based on the proposed model, we calculate the maximal value of the spectral efficiency in systems with a dense arrangement of 100G DP-QPSK channels (∼3.2 bit s{sup −1} Hz{sup −1}). (fibre-optic communication)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Symptomatic Plasmodium vivax Infection in Rwanda

Here, we report a Plasmodium vivax infection in a Rwandan child misdiagnosed with Plasmodium falciparum and administered artemether-lumefantrine. Antigen detection revealed an absence of P falciparum histidine-rich protein 2 (HRP2) and presence of Plasmodium vivax lactate dehydrogenase. Nested and real-time polymerase chain reactions verified that the sample only contained P vivax deoxyribonucleic acid.

60 APPLIED LIFE SCIENCES↗

Learning broken symmetries with approximate invariance

Recognizing symmetries in data allows for significant boosts in neural network training, which is especially important where training data are limited. In many cases, however, the exact underlying symmetry is present only in an idealized dataset, and is broken in actual data, due to asymmetries in the detector, or varying response resolution as a function of particle momentum. Standard approaches, such as data augmentation or equivariant networks fail to represent the nature of the full, broken symmetry, effectively overconstraining the response of the neural network. We propose a learning model which balances the generality and asymptotic performance of unconstrained networks with the rapid learning of constrained networks. This is achieved through a dual-subnet structure, where one network is constrained by the symmetry and the other is not, along with a learned symmetry factor. In a simplified toy example that demonstrates violation of Lorentz invariance, our model learns as rapidly as symmetry constrained networks but escapes its performance limitations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Development of an MKID frequency-to-pixel LED mapper for SPT-3G+

SPT-3G+ is the next-generation camera for the South Pole Telescope (SPT). SPT is designed to measure the cosmic microwave background (CMB) and the mm/sub-mm sky. The planned focal plane consists of 34,000 microwave kinetic inductance detectors (MKIDs), divided among three observing bands centered at 220, 285, and 345 GHz. Each readout line is designed to measure 800 MKIDs over a 500 MHz bandwidth, which places stringent constraints on the accuracy of the frequency placement required to limit resonator collisions that reduce the overall detector yield. To meet this constraint, we are developing a two-step process that first optically maps the resonance to a physical pixel location, and then next trims the interdigitated capacitor (IDC) to adjust the resonator frequency. We present a cryogenic LED apparatus operable at 300 mK for the optical illumination of SPT-3G+ detector arrays. We demonstrate integration of the LED controls with the GHz readout electronics (RF-ICE) to take data on an array of prototype SPT-3G+ detectors. We show that this technique is useful for characterizing defects in the resonator frequency across the detector array and will allow for improvements in the detector yield.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Modeling of Hypervelocity Impact Experiments Using Gamma-SPH Technique

Hypervelocity impact research has been conducted using light gas guns to characterize materials under shock conditions. Hypervelocity impact produces high pressure and temperature states during the projectile-target interaction. Projectile and target materials both experience severe localized deformation under these conditions, which creates stretching, bending, and complete perforation in thin target plates. Relatively thick target plates show several failure modes, such as spalling, petalling, discing, and plugging. These failure modes are mostly controlled by several factors such as impact velocity, material properties, loading geometry, etc. Gas gun experiments were performed to measure the plastic deformation of steel plates during hypervelocity impact. The MPDV system was used to measure free surface velocity during these experiments. Simulation models developed in the IMPETUS AFEA Gamma SPH solver show that the physical measurements of impact cratering and bulge are in reasonable agreement with simulation results. Velocity profiles are in general agreement with the experiments capturing all the major features observed experimentally.

36 MATERIALS SCIENCE↗

Microfluidic molecular assay platform for the detection of miRNAs, mRNAs, proteins, and post-translational modifications at single-cell resolution

In this study, cell signaling is a dynamic and complex process. A typical signaling pathway may begin with activation of cell surface receptors, leading to activation kinase cascade that culminates in induction of mRNA and non-coding miRNA production in the nucleus, followed by modulation of mRNA expression by miRNAs in the cytosol, and end with production of proteins in response to the signaling pathway. Signaling pathways involve proteins, miRNA, and mRNAs, along with various forms of transient post-translational modifications, and detecting each type of signaling molecule requires categorically different sample preparation methods such as Western blotting for proteins, PCR for nucleic acids, and flow cytometry for post-translational modifications. Since we know that cells in populations behave heterogeneously1, especially in the cases of stem cells, cancer, and hematopoiesis, there is need for a new technology that provides capability to detect and quantify multiple categories of signaling molecules in intact single cells to provide a comprehensive view of the cell’s physiological state. In this technical brief, we describe our microfluidic platform with a portfolio of customized molecular assays that can detect nucleic acids, proteins, and post-translational modifications in single intact cells with >95% reduction in reagent requirement in under 8 hours.

42 ENGINEERING↗

A multiple-alignment based primer design algorithm for genetically highly variable DNA targets

Background: Primer design for highly variable DNA sequences is difficult, and experimental success requires attention to many interacting constraints. The advent of next-generation sequencing methods allows the investigation of rare variants otherwise hidden deep in large populations, but requires attention to population diversity and primer localization in relatively conserved regions, in addition to recognized constraints typically considered in primer design. Results: Design constraints include degenerate sites to maximize population coverage, matching of melting temperatures, optimizing de novo sequence length, finding optimal bio-barcodes to allow efficient downstream analyses, and minimizing risk of dimerization. To facilitate primer design addressing these and other constraints, we created a novel computer program (PrimerDesign) that automates this complex procedure. We show its powers and limitations and give examples of successful designs for the analysis of HIV-1 populations. Conclusions: PrimerDesign is useful for researchers who want to design DNA primers and probes for analyzing highly variable DNA populations. It can be used to design primers for PCR, RT-PCR, Sanger sequencing, next generation sequencing, and other experimental protocols targeting highly variable DNA samples.

59 BASIC BIOLOGICAL SCIENCES↗

Multipoint sensing with a low-coherence source using single-arm frequency-shifted interferometry

We demonstrate that multiple-site sensing along an optical fiber can be done with incoherent continuous-wave light. Here, using a broadband low-coherence noise source, a slow detector, and an optical modulator, we construct a single-arm frequency-shifted interferometer (SA-FSI) capable of simultaneously sensing multiple weak-reflection sites distributed either in parallel or in series along fiber links. By scanning the driving frequency of an electro-optic amplitude modulator in the range of 2.7–3.2 GHz at steps of 41.7 KHz, we demonstrate a spatial resolution of 0.3 m and a measurement range of over 1 km.

36 MATERIALS SCIENCE↗

Power Excursion Mitigation for Flexgrid Defragmentation With Machine Learning

Flexgrid optical networking relies on spectrum defragmentation to groom channel wavelengths and improve spectral efficiency. Various defragmentation methods—hop, make-before-break, and sweep—interact with the power dynamics of erbium-doped fiber amplifiers (EDFA) differently and result in undesired power excursions that exacerbate the post-EDFA power variance. Here we present a machine learning engine that characterizes the channel dependence of power excursions from historical data. We further demonstrate that post-EDFA power variance during hop, make-before-break, and sweep defragmentation methods can be greatly mitigated by the trained machine learning engine with automated and expedited power adjustment predictions.

42 ENGINEERING↗

Demonstration of a Hitless Bypass Switch Using Nanomechanical Perturbation for High-bitrate Transparent Networks

We demonstrate an optical hitless bypass switch based on nanomechanical proximity perturbation for high-bitrate transparent networks. Embedded in a single-level {pi}-imbalanced Mach-Zehnder interferometer, the two nanomechanical-based {Delta}{beta}-directional couplers permit broadband signal rerouting on-chip, while the selected wavelength remains unaffected at all times for optical filter reconfiguration. The optical hitless switch is implemented in the silicon nanophotonics platform, with experimental measurements matching well with numerical and theoretical modeling.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Nonlocal subpicosecond delay metrology using spectral quantum interference

Precise knowledge of position and timing information is critical to support elementary protocols such as entanglement swapping on quantum networks. While approaches have been devised to use quantum light for such metrology, they largely rely on time-of-flight (ToF) measurements with single-photon detectors and, therefore, are limited to picosecond-scale resolution owing to detector jitter. In this work, we demonstrate an approach to distributed sensing that leverages phase modulation to map changes in the spectral phase to coincidence probability, thereby overcoming the limits imposed by single-photon detection. By extracting information about the joint biphoton phase, we measure a generalized delay—the difference in signal–idler arrival, relative to local radio frequency (RF) phase modulation. For nonlocal ranging measurements, we achieve (2$σ$) precision of ±0.04 ps and for measurements of the relative RF phase, (2$σ$) precision of ±0.7°. We complement this fine timing information with ToF data from single-photon time-tagging to demonstrate absolute measurement of time delay. By relying on off-the-shelf telecommunications equipment and standard quantum resources, this approach has the potential to reduce overhead in practical quantum networks.

42 ENGINEERING↗

Fueling the Future: The Emergence of Self-Powered Enzymatic Biofuel Cell Biosensors

Self-powered biosensors are innovative devices that can detect and analyze biological or chemical substances without the need for an external power source. These biosensors can convert energy from the surrounding environment or the analyte itself into electrical signals for sensing and data transmission. The self-powered nature of these biosensors offers several advantages, such as portability, autonomy, and reduced waste generation from disposable batteries. They find applications in various fields, including healthcare, environmental monitoring, food safety, and wearable devices. While self-powered biosensors are a promising technology, there are still challenges to address, such as improving energy efficiency, sensitivity, and stability to make them more practical and widely adopted. This review article focuses on exploring the evolving trends in self-powered biosensor design, outlining potential advantages and limitations. With a focal point on enzymatic biofuel cell power generation, this article describes various sensing mechanisms that employ the analyte as substrate or fuel for the biocatalyst’s ability to generate current. Technical aspects of biofuel cells are also examined. Research and development in the field of self-powered biosensors is ongoing, and this review describes promising areas for further exploration within the field, identifying underexplored areas that could benefit from further investigation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗