Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Multiplex”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,405 records · Page 78

Low Global Warming Potential Refrigerants for Commercial Refrigeration Systems

Supermarket refrigeration systems account for approximately 50% of supermarket energy use, placing this class of equipment among the highest energy consumers in the commercial building domain. In addition, the commonly used refrigeration system in supermarket applications is the multiplex direct expansion (DX) system, which is prone to refrigerant leaks due to its long lengths of refrigerant piping. This leakage reduces the efficiency of the system and increases the impact of the system on the environment. The high Global Warming Potential (GWP) of the hydrofluorocarbon (HFC) refrigerants commonly used in these systems, coupled with the large refrigerant charge and the high refrigerant leakage rates leads to significant direct emissions of greenhouse gases into the atmosphere. Environmental concerns are driving regulations for the heating, ventilating, air-conditioning and refrigeration (HVAC&R) industry towards lower GWP alternatives to HFC refrigerants. Existing lower GWP refrigerant alternatives include hydrocarbons, such as propane (R-290) and isobutane (R-600a), as well as carbon dioxide (R-744), ammonia (R-717), and R-32. In addition, new lower GWP refrigerant alternatives are currently being developed by refrigerant manufacturers, including hydrofluoro-olefin (HFO) and unsaturated hydrochlorofluorocarbon (HCFO) refrigerants. The selection of an appropriate refrigerant for a given refrigeration application should be based on several factors, including the GWP of the refrigerant, the energy consumption of the refrigeration system over its operating lifetime, and leakage of refrigerant over the system lifetime. For example, focusing on energy efficiency alone may overlook the significant environmental impact of refrigerant leakage; while focusing on GWP alone might result in lower efficiency systems that result in higher indirect impact over the equipment lifetime. Thus, the objective of this Collaborative Research and Development Agreement (CRADA) between Honeywell and the Oak Ridge National Laboratory (ORNL) is to develop a Life Cycle Climate Performance (LCCP) modeling tool for optimally designing HVAC&R equipment with lower life cycle greenhouse gas emissions, and the selection of alternative working fluids that reduce the greenhouse gas emissions of HVAC&R equipment. In addition, an experimental evaluation program is used to measure the coefficient of performance (COP) and refrigerating capacity of various refrigerant candidates, which have differing GWP values, in commercial refrigeration equipment. Through a cooperative effort between industry and government, alternative working fluids will be chosen based on maximum reduction in greenhouse gases at minimal cost impact to the consumer. This project will ultimately result in advancing the goals of reducing greenhouse gas emissions through the use of low GWP working fluids and technologies for HVAC&R and appliance equipment, resulting in cost-competitive products and systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Particle integrity, sampling, and application of a DNA-tagged tracer for aerosol transport studies

Aerosols are an ever-present part of our daily environment and have extensive effects on both human and environmental health. Particles in the inhalable range (1-10 μm diameter) are of particular concern because their deposition in the lung can lead to a variety of illnesses including allergic reactions, viral or bacterial infections, and cancer. Understanding the transport of inhalable aerosols across both short and long distances is necessary to predict human exposures to aerosols. To assess the transport of hazardous aerosols, surrogate tracer particles are required to measure their transport through occupied spaces. These tracer particles must not only possess similar transport characteristics to those of interest but also be easily distinguished from the background at low levels and survive the environmental conditions of the testing environment. A previously-developed DNA-tagged particle (DNATrax), composed of food-grade sugar and a DNA oligonucleotide as a “barcode” label, shows promise as a new aerosol tracer. Herein, the use of DNATrax material is validated for use in both indoor and outdoor environments. Utilizing passive samplers made of materials commonly found in indoor environments followed by quantitative polymerase chain reaction (qPCR) assay for endpoint particle detection, particles detection was achieved up to 90 m from the aerosolization location and across shorter distances with high spatial resolution. The unique DNA label and PCR assay specificity were leveraged to perform multiple simultaneous experiments. This allowed the assessment of experimental reproducibility, a rare occurrence among aerosol field tests. To transition to outdoor testing, the solid material provides some protection of the DNA label when exposed to ultraviolet (UV) radiation, with 60% of the DNA remaining intact after 60 minutes under a germicidal lamp and the rate of degradation declining with irradiation time. Additionally, exposure of the DNATrax material using formulations of two different food-grade sugars (maltodextrin and erythritol) to humidity as high as 66% had no significant effect on the DNA label’s degradation or the particle’s aerodynamic diameter, confirming particle stability under such conditions. In summary, confirmation of the DNATrax particles’ size and label integrity under variable conditions combined with experiment multiplexing and high resolution sampling provides a powerful experimental design for modeling aerosol transport through occupied indoor and outdoor locations.

54 ENVIRONMENTAL SCIENCES↗

Fast Switching Magnet for Heavy Ion Beam Separation

Fast magnets for multiplexing ion beams between different beamlines are technologically challenging and expensive, but there is an ever-growing need to develop such systems for beam separation at research and industrial facilities. For example, The Argonne Tandem Linac Accelerator System (ATLAS) is planning to expand its operations as a multi-user facility and there is a clear need, presently unmet by the industry, for a switching magnet system with the sub-millisecond transient times.In response to this problem, RadiaBeam Technologies is developing a novel pulsed switching magnet system capable of producing a 1.1T peak field over 45 cm length with a short (<1 ms) rise and fall time. The key enabling innovation in this project is an introduction of a solid-state interposed modulator architecture, which enables to improve magnet performance and reliability and reduce the cost to a practical level.

43 PARTICLE ACCELERATORS↗

Optical Encoding Technology for Viral Screening Panels Final Report CRADA No TC02132.0

This was a collaborative effort between Lawrence Livermore National Security, LLC, Lawrence Livermore National Laboratory (LLNL) and Parallel Synthesis Technologies, Inc. (PSTI), to develop Optical Encoding Technology for Viral Screening Panels. The goal for this effort was to prepare a portable bead reader system that would enable the development of viral and bacterial screening panels which could be used for the detection of any desired set of bacteria or viruses in any location. The main objective was to determine if the combination of a bead-based, PCR suspension array technology, formulated from Parallume encoded beads and PSTI’s multiplex assay reader system (MARS), could provide advantages in terms of the number of simultaneously measured samples, portability, ruggedness, ease of use, accuracy, precision or cost as compared to the Luminexbased system developed at LLNL. The project underwent several no cost extensions however the overall goal of demonstrating the utility of this new system was achieved. As a result of the project a significant change to the type of bead PSTI used for the suspension system was implemented allowing better performance than the commercial Luminex system.

59 BASIC BIOLOGICAL SCIENCES↗

A Full Mesh ATCA-based General Purpose Data Processing Board (Pulsar II)

The Pulsar II is a custom ATCA full mesh enabled FPGA-based processor board which has been designed with the goal of creating a scalable architecture abundant in flexible, non-blocking, high bandwidth interconnections. The design has been motivated by silicon-based tracking trigger needs for LHC experiments. In this technical memo we describe the Pulsar II hardware and its performance, such as the performance test results with full mesh backplanes from different vendors, how the backplane is used for the development of low-latency time-multiplexed data transfer schemes and how the inter-shelf and intra-shelf synchronization works.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Next Generation Qualification: Guralp Systems Affinity Digitizer Evaluation

Sandia National Laboratories has tested and evaluated a new digitizer, the Affinity, manufactured by Guralp Systems Ltd. These digitizers are used to record sensor output for seismic and infrasound monitoring applications. The purpose of the digitizer evaluation was to measure the performance characteristics in such areas as power consumption, input impedance, sensitivity, full scale, self-noise, dynamic range, system noise, response, passband, and timing. The Affinity digitizer is Guralp's latest release in their digitizer product line. The Affinity is available with either 4 or 8 channels at 24 bit resolution. In addition to the 24 bit channels, 16 multiplexed low resolution channels are provided. Other features include the means to accept multiple types of timing sources (e.g. GPS, NTP and PTP) and a web page interface for command and control of the unit.

47 OTHER INSTRUMENTATION↗

Time Dependent Analysis of Laser Heating of Metal Parts in Contact with HE

We consider the time dependent heat transfer of laser energy impinging on metal parts that are in contact with high explosives (HE). The predecessor to this calculation was TN-J4-17-2109, “Heat Transfer Analysis from Laser Energy on Metal Parts in Contact with HE”, which considered the time independent heat transfer and compared to experimental results. The intent here is to extend those results to the time dependent case. The steady-state results were developed because they were the “worst case” from a safety perspective: the steady state represents the highest possible temperature excursion. However, we found that the temperatures achieved were well above the safety limits established by the DOE High Explosives Safety Manual. Moreover, they were well above the safety limit published by the LANL / Weapons Facilities Operations (WFO) in WFO-OS-ES-48, which establishes an upper temperature limit of 70°C for metal in contact with High Explosive (HE). The J-4 response to the original results was to design, build, and deploy an interlock system for DARHT that would ensure no laser energy on the firing point when both personnel and HE were present. This system was tested and proved effective, refer TP-DARHT-1150, (12/19/2016). It was reviewed and approved by the LANL Explosives Instrumentation Review Committee, refer PRES-J4-16-2140, “DARHT Laser Diagnostics Interlock System: Presentation to the EIRC”, (2016). Although the interlock system prevented personnel from being on the firing point under conditions where the diagnostic lasers would heat metal above the WFO limit, the WFO limit was still exceeded during the Multiplexed Photonic Doppler Velocimetry (MPDV) tuning process. The only practical solution is to limit the amount of time that the MPDV lasers are engaged at full power. The diagnostics interlock system was implemented with laser shutters that can fully interrupt the beams, and these shutters can be used to limit the amount of time that the lasers will impinge on the hydrotest assembly. It is the purpose of this paper to provide quantitative guidance on what length of time can be permitted during this tuning process. Therefore, we will solve the time-dependent heat transfer equation to determine the temperature increase as a function of time. This function can be inverted to determine the maximum allowable time for energizing the lasers based on the maximum allowable temperature at the metal to HE interface.

42 ENGINEERING↗

Vibro-acoustic Testing for Microstructure Characterization and Metrology: Technology Commercialization Fund—Fiscal Year 2017

There is a need in nuclear reactors to inspect irradiated materials and structures. A portable scanning infrastructure for a material characterization technique called vibro acoustography (VA) is being developed by the Idaho National laboratory for nuclear applications to characterize fuel, cladding materials, and structures. The proposed VA technology is based on ultrasound and acoustic waves; however, it provides information beyond what is available from the traditional ultrasound techniques and can expand the knowledge on nuclear material characterization and microstructure evolution. VA technique has several advantages over traditional characterization techniques. VA is a non-contact submersion technique that is inherently wireless transmission and reception (from the ultrasonic transmitter to the acoustic receiver). The transmission medium can be most liquids used for reactor cooling such as water and sodium. For nuclear in-pile applications, the Ultrasonic Transducer (UT) will need to have a line of sight location that is within lower radiation flux zones. Multiple UT sources can be frequency multiplexed to allow a single hydrophone receiver to monitor several locations. The reactor structure can also be an integral part of the transmission system acting as waveguides to deliver the acoustic signal to an acoustic receiver. Because of the long wavelength of the acoustic signal, the acoustic receiver does not have to be line of sight with respect to the component under test. The focusing and generation of the acoustic beat frequency from two ultrasonic waves allows for the potential to ultrasonically image complex shapes. These features will significantly reduce experiment complexity, installation times and cost while being safe and easy to use.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Laser-Driven Megavolt X-Ray and Neutron Source Optimization

This 4-month feasibility study assessed the options, trade-offs and major issues in using National Ignition Facility (NIF) and Advanced Radiographic Capability (ARC)-class laser beams for multipulse MeV x-ray and neutron radiography of high explosives (HE) driven experiments. It was performed in close collaboration with a second FS evaluating future HE radiography requirements and expected laser-based source data quality with respect to existing and alternate radiography sources. The study first reviewed the existing published data on MeV x-ray and neutron sources compared to requirements on yield (10 14 /sr for X-rays, > 10 13 /sr for neutrons), spot size (< 1 mm) and duration (< 20 ns). For MeV neutron sources, the preferred options are DTfilled exploding pusher targets or stagnating DT plasmas, each source requiring 50 kJ level. few ns beam irradiation at 0.5 or 0.35 micron wavelength. The preferred X-ray MeV source option to be fully assessed by a follow-up SI is an angularly and temporally-multiplexed multi-burst version of a Bremsstrahlung source (Courtois et al. 2011) irradiated by up to 7 10 ps, kJ-class 1 micron wavelength lasers beams. This multi-burst laser mode, submitted as an ROI and patent, should increase final laser optics damage energy thresholds based on 2 pulse tests and hence allow near full extraction of the 15 kJ of 1 micron laser energy available on a NIF beamline. Hydrodynamic simulations were used to evaluate the effects of preceding pulse irradiation on target integrity, and show that this can be mitigated by using 3D structured targets.

47 OTHER INSTRUMENTATION↗

A Platform for Genome-Scale Design, Redesign, and Optimization of Bacterial Systems

This project was a collaboration between the Gill and Knight labs at University of Colorado Boulder, the Arkin lab at University of California Berkeley, and the Maness group at the National Renewable Energy Laboratory. There were two main objectives for this project: Objective 1: Integrated, genome-scale strategy for “chassis” strain design and construction. Objective 2: Genome “re-design” framework using multiplex synbio and genome-engineering technologies.

59 BASIC BIOLOGICAL SCIENCES↗

Development and refinement of an in situ ‘molecular microscope’ utilizing ultrahigh resolution mass spectrometry

The ability to elucidate complex metabolic behavior of living organisms in situ and with cellular resolution is a bioanalytical grand challenge that is yet to be realized. Mass spectrometry imaging (MSI) using laser ablation electrospray ionization mass spectrometry (LAESI) has recently been demonstrated, and holds promise for direct spatially resolved molecular profiling in a variety of living systems of DOE relevance (e.g., plant leaf, stem, and root tissue). The LAESI MSI approach has revealed cell-to-cell heterogeneity of metabolites within living plant tissue, in a multiplexed fashion and without the need for labeling. Cellular resolution by in situ, ambient pressure MSI methods are far from routine, however, and have inadequate spatial resolution for many biological questions of interest. We propose to develop next-generation LAESI approaches, using advanced fiber optics and transmission-based geometries, in efforts to attain dynamic bioanalysis of living systems at better than 20 µm lateral resolution. In parallel with LAESI innovations, attendant increases in sensitivity and dynamic range of the mass spectrometer system will also be necessary for detection of the limited amount of material being ionized. To respond to this need, a new, high magnetic field (21 Tesla) Fourier Transform Ion Cyclotron Resonance (FTICR) MS at the EMSL/PNNL will be coupled with the newly developed LAESI source. This mass spectrometer, currently being assembled, will be one of only two such systems in the world, and the only one in a DOE laboratory or user facility. Fundamentally, all key figures of merits of FTICR MS performance improve with increased magnetic field strength, providing the ability to achieve unparalleled molecular specificity (near unequivocal molecular constituent identification) at the highest possible mass resolving power and sensitivity. The work proposed here will greatly increase the utility of this FTICR MS instrument, providing unique capabilities to support BER-relevant science. The research plan is comprised of three tasks, two of which are directed by the academic leads (University of Missouri and George Washington University), and one of which will be performed in conjunction with the BER user facility at EMSL/PNNL. In task 1, advancements of the LAESI technology will be achieved, with oversight and leadership of Professor Akos Vertes of George Washington University. In task 2, incorporation of this ion source with EMSL’s new 21T FTICR MS system will be undertaken, supplemented by global omics measurements and calibrated against more conventional MSI platforms also available at EMSL (Drs. Pasa-Tolic, Anderton, and Koppenaal team). In the final task, the resultant innovations and advancements will be tested and validated by addressing important BER relevant science questions on model systems of interest under the direction of Professor Gary Stacey of the University of Missouri. This research follows on key recommendations of the recent BER “Research in Sustainable Bioenergy” report that, for example, stressed that “The design of sustainable biofuel systems requires knowledge about key plant-microbe-environment interactions that provide a range of ecosystem services.” This task will focus on validation of the instrumentation developed through this proposal, advertising this capability to the community through demonstration and, finally, discovering new biology relevant to the BER mission. This final objective will make use of Setaria viridis, a model C4 grass species, as well as switchgrass and sorghum, two promising biofuel crops. Specifically, we will demonstrate applicability to plant-microbe rhizosphere interactions focusing on the biological nitrogen fixation by monitoring metabolic changes in real-time with nutrient, growth condition, and other perturbations.

09 BIOMASS FUELS↗

Develop and Test TXM Battery Cells

Summary of the specific research and project accomplishments: The team combined their knowledge and expertise in x-ray science and electrochemistry to quantify lithium concentration gradients for commercially relevant metal oxide cathodes at rates up to 6C. Completion of the project required several significant technical developments including new x-ray experimental methodologies, high-speed and high-accuracy sample multiplexers and a new class of x-ray compatible cells. The results from thin and thick electrodes demonstrated that both spatial heterogeneity and concentration gradients through the thickness of the cathode may be present. The relevance of either phenomena appears to be correlated to aspects of the electrode such as calendaring in addition to the configuration of the experiment (e.g. force between the anode and cathode).

25 ENERGY STORAGE↗

Astro2020 APC White Paper: The MegaMapper: a z > 2 Spectroscopic Instrument for the Study of Inflation and Dark Energy

MegaMapper is a proposed ground-based experiment to measure Inflation parameters and Dark Energy from galaxy redshifts at 2¡z¡5. A 6.5-m Magellan telescope will be coupled with DESI spectrographs to achieve multiplexing of 20,000. MegaMapper would be located at Las Campanas Observatory to fully access LSST imaging for target selection.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Maunakea Spectroscopic Explorer

The Maunakea Spectroscopic Explorer is a next-generation massively multiplexed spectroscopic facility currently under development in Hawaii. It is completely dedicated to large-scale spectroscopic surveys and will enable transformative science. In this white paper we summarize the science case and describe the current state of the project.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SpecTel: A 10-12 meter class Spectroscopic Survey Telescope

We recommend a conceptual design study for a spectroscopic facility in the southern hemisphere comprising a large diameter telescope, fiber system, and spectrographs collectively optimized for massively-multiplexed spectroscopy. As a baseline, we propose an 11.4-meter aperture, optical spectroscopic survey telescope with a five square degree field of view. Using current technologies, the facility could be equipped with 15,000 robotically-controlled fibers feeding spectrographs over 360<λ<1330 nm with options for fiber-fed spectrographs at high resolution and a panoramic IFU at a separate focus. This would enable transformational progress via its ability to access a larger fraction of objects from Gaia, LSST, Euclid, and WFIRST than any currently funded or planned spectroscopic facility. An ESO-sponsored study (arXiv:1701.01976) discussed the scientific potential in ambitious new spectroscopic surveys in Galactic astronomy, extragalactic astronomy, and cosmology. The US community should establish links with European and other international communities to plan for such a powerful facility and maximize the potential of large aperture multi-object spectroscopy given the considerable investment in deep imaging surveys.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Jiangsu Nanjing – Lawrence Berkeley Life Sciences Center for Translational Medicine (CRADA AWD00000392)

Project 1: Our previous work demonstrated that the CES biomarker can be an approximate measure for the levels of chromosomal instability (CIN) in cancer, and that the CES (for Centromere and kinetochore gene Expression Score) biomarker effectively predicts which cancer patients benefit from adjuvant chemotherapies in lung and other cancer types. Such a utility can potentially reduce overtreatment that is common in lung cancer treatment. We determined performance of the multiplex Quantigene RNA assay platform for measuring mRNA levels of CES genes using clinical tumor samples. These experiments determined sensitivity, specificity and detection limit of 12 CES genes and 5 control genes using clinical tumor samples with paired normal tissue samples. We determined how sample concentration and storage conditions affect measurement sensitivity and specificity, and whether sample storage over time affects result reproducibility. Importantly, we confirmed that early stage lung cancer CES values are significantly higher than those of paired normal tissues in all cases. This result greatly extended our bioinformatic data mining by confirming that we can measure CES values directly from patient tumor tissue, and that tumors have higher CES values than normal tissues. Unfortunately, our CRADA partner in China did not finish measuring CES expression levels for a larger group of ~100 tumor samples, due to the long period time required for human subject review in China. This delay prevented us from generating enough additional data to generate a significant statistical model. We finished analyzing all the data acquired during the CRADA, and are trying to work collaboratively with the Shanghai University Lung Cancer Hospital to complete the analysis of more tumor samples. Although no publications have resulted from this research, the findings are crucial for ongoing efforts to obtain funding to develop the technology to address problems in deciding on appropriate treatment regimens for individual patients, in clinical settings. Project 2: The overarching milestones of CRADA Project 2 were to investigate the role of FAM83 family members in cancer progression. Two publications resulted from this work which are highlighted below. The first major goal of the CRADA was to broadly assess the role of FAM83 family oncogenes in human cancer using a multi-omic bioinformatic approach (Snijders et al 2017 Mol. Oncol 11). The second major goal was to specifically assess the role of FAM83D in a cancer progression and metastasis (Yin et al 2019 Cell Oncol; in revision). Role of FAM83 family oncogenes in human cancers Recent studies from our laboratory as well as other groups have demonstrated that FAM83 family members have oncogenic properties and have significantly elevated expression levels in multiple human tumor types, including breast cancers (BC). We performed an integrative multi-omics bio-informatic analysis of the role of FAM83 family oncogenes in human cancers. Our findings were published in the journal Molecular Oncology (Snijders et al; Mol Oncol. 2017 Feb;11(2):167-179). Highlights from this manuscript are: • Transcriptional levels of FAM83 family members are frequently and dramatically elevated across tumor types in human • DNA copy number increase appears to be a potential mechanism for increased expression of FAM83 genes • FAM83 family gene signature is associated with poor survival across human tumor types • FAM83 gene alterations are significantly correlated with TP53, PIK3CA and Ecadherin mutations. In conclusion, this analysis of FAM83 family members opened up a new horizon for further understanding the significance of FAM83 genes in cancer and clinical applications in diagnosis, prognosis and therapy. Role of FAM83D in human non-small cell lung cancer (NSCLC) metastasis and its impact on chemotherapy. Lung cancer is one of the most common malignant tumors in the world and non-small cell lung cancer (NSCLC) accounts for 80~85% of all diagnosed lung cancer cases, one of the deadliest cancers worldwide. FAM83D has been proposed as an oncoprotein in several types of human cancer, yet its role and molecular mechanism in human non-small cell lung cancer (NSCLC) metastasis and its impact on chemotherapy are poorly understood. We evaluated the expression of FAM83D in NSCLC cells and cancerous tissues and its prognostic significance, then investigated the effect of FAM83D on tumorigenic phenotypes such as cell proliferation, EMT and invasive capability, and finally assessed impact of FAM83D on NSCLC chemo-drug resistance. The results of this study are currently in revision at the journal Cellular Oncology. Highlights from this manuscript are: • FAM83D expression is elevated in NSCLC cells and tissues and associated with poor prognosis • FAM83D promotes NSCLC cell proliferation • FAM83D induces EMT in NSCLC cells • FAM83D promotes NSCLC cell migration and invasion • FAM83D promotes EMT and invasive capability of NSCLC cells by regulating AKT/mTOR pathway • FAM83D silencing increases cisplatin sensitivity of NSCLC cells In summary, this second study demonstrated for the first time that FAM83D promoted EMT and metastasis of NSCLC cells through AKT/mTOR signal pathway as well as increased the sensitivity of NSCLC to cisplatin. This study may provide potential targets for advanced NSCLC treatment and personalized therapy.

59 BASIC BIOLOGICAL SCIENCES↗

Subsequent R + O 2 Chemistry of Intermediates Formed in Low-Temperature R + O 2 Reactions: Potential Importance in Modeling Autoignition Behavior

Comprehensive chemical kinetics models used in the simulation of hydrocarbon and biofuel oxidation rely on accurate prescription of the underlying reaction mechanisms and rate parameters of associated elementary reactions. For practical transportation fuels, such models contain thousands of elementary reactions, which collectively define chain-initiation, -propagation, -branching, and -inhibition pathways. In the low-temperature regime, below approximately 1000 K where R + O 2 reactions dominate, primary oxidation intermediates including cyclic ethers, carbonyls, and conjugate alkenes are formed in abundance via unimolecular decomposition of either chemically activated or thermalized radicals, specifically organic peroxy (ROO) or hydroperoxyalkyl species (QOOH). Experimental results from multiplexed photoionization mass spectrometry (MPIMS) experiments are detailed herein for several intermediates, derived initially from R + O 2 reactions of hydrocarbons and biofuels, and show that intermediate species formed in the initial steps of oxidation undergo similar reactions to those of the parent molecule, including through QOOH-mediated pathways. Products from QOOH decomposition via chain-inhibition and chain-propagation pathways, namely conjugate alkenes, carbonyls, and cyclic ethers, are detected directly. Despite such rich chemistry involving QOOH radicals, most comprehensive chemical kinetics models neglect the complete description of primary oxidation intermediates, and rather consider a restricted number of reaction pathways. It is suggested that exclusion of the details of the oxidation of these intermediate products may affect the interpretation of combustion simulations using such models.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

TRANSENSOR: Transformer Real-time Assessment INtelligent System with Embedded Network of Sensors and Optical Readout. Final Report

Utilities across the world are wrestling with evolving market dynamics, population growth and climate change. Distributed Energy Resources (DERs) such as solar photovoltaics, distributed generators and energy storage systems are becoming important parts of the U.S. energy mix. These factors are driving an increasing need for low-cost grid asset monitoring. Aside from being costly, traditional utility monitoring systems are not sufficiently robust and do not provide real-time visibility into the condition of grid assets such as transformers. Lack of accurate real-time measurements on performance has resulted in the use of lagging indicators, such as oil sample analysis. To address this need, an innovative embedded optical sensing technology, Transformer Real-time Assessment Intelligent System (TRANSENSOR) was developed, validated and demonstrated in this project. To date, TRANSENSOR has focused on transformers but is extendable to other grid assets. In addition to the technology being embedded into new transformers during manufacturing, a retrofit configuration that can be installed on existing transformers in the field was also developed. It is anticipated that the ability to retrofit existing transformers will help accelerate adoption of the underlying TRANSENSOR technology. Phase 1 of the project focused on laboratory development and qualification of the technology. Following iterations and exploration of relevant optical sensing modalities and multiplexed configurations of interest for the transformer environment, an effective candidate configuration was agreed upon, down-selected and custom-designed for embedding into General Electric (GE) network transformers. Two new GE 500 kilovolt ampere (kVA), 27 kilovolt (kV) distribution network transformers were built with embedded fiber-optic (FO) sensors and successfully qualified per industry standards at GE’s Shreveport, Louisiana facility during Phase 1 of the project. Following the successful completion of Phase 1, the team proceeded to Phase 2, which focused on a field demonstration of the technology. Over Phase 2, the first new GE transformer built with embedded fiber-optic sensors was installed in an above-ground cage and connected to the grid at Con Edison’s Astoria facility. A second transformer equipped with TRANSENSOR was installed in an underground vault. Additionally, an older (1982 year model) GE transformer in an above-ground cage was retrofitted with fiber- optic sensors and reconnected to the grid at ConEd’s facility. Analysis of data acquired from the sensors showed interesting correlations with transformer loading. Additionally, key events such as transformer low-voltage network connection, primary-side energizing, and a pressure loss event from an oil sampling were detected by the TRANSENSOR system. Online data processing/feature extraction algorithms for the second transformer in the underground vault detected key features and event alerts that were transmitted through a wireless 4G connection. The remote deployment concept showed promising results with data collection running for a total of 8 months across the three (3) GE transformers instrumented for the Phase 2 field demonstration. This sets the stage well for further development and commercialization.

24 POWER TRANSMISSION AND DISTRIBUTION↗