Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Modal Testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,405 records · Page 78

Wireless Sensing, Monitoring and Optimization for Campus-Wide Steam Distribution

The US Congress has passed legislation dictating that all government agencies establish a plan and process for improving energy efficiencies at their sites. In response to this legislation, Oak Ridge National Laboratory (ORNL) has recently conducted a pilot study to explore the deployment of a wireless sensor system for a real-time measurement-based energy efficiency optimization. With particular focus on the 12-mile long steam distribution network in our campus, we propose an integrated system-level approach to optimize energy delivery within the steam distribution system. Our approach leverages an integrated wireless sensor and real-time monitoring capability. We make real time state assessment on the steam trap health and steam flow estimate of the distribution system by mounting acoustic sensors on the steam pipes/traps/valves and observing measurements of these sensors with state estimators for system health. Our assessments are based on a spectral-based energy signature scheme that interprets acoustic vibration sensor data to estimate steam flow rates and assess steam traps status. Experimental results show that the energy signature scheme has the potential to identify different steam trap states and it has sufficient sensitivity to estimate flow rate. Moreover, results indicate a nearly quadratic relationship over the test region between the overall energy signature factor and flow rate in the pipe. We are able to present the steam flow and steam trap status, sensor readings, and the assessed alerts as an interactive overlay within a web-based Google Earth geographic platform that enables decision makers to take remedial action. The goal is to achieve significant energy-saving in steam lines by monitoring and acting on leaking steam pipes/traps/valves. We believe our demonstration serves as an instantiation of a platform that extends implementation to include newer modalities to manage water flow, sewage and energy consumption.

54 ENVIRONMENTAL SCIENCES↗

Creating a Vibration Data Visualization and Analysis Graphical User Interface in Matlab [Poster]

Vibration testing in W-14 results in large amounts of data that need to be preprocessed before being used in reports or for model verification. It can take a large amount of time to accomplish simple, repetitive tasks on many channels of data. A Graphical User Interface (GUI) streamlines visualization and simple processing of the data to make the process faster as well as more intuitive. Simple editing methods, such as data segmentation and axis conversion, put the data in a form that can be easily moved into a more advanced modal analysis or data plotting package.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Neuroscience Investigations: An Overview of Studies Conducted

The neural processes that mediate human spatial orientation and adaptive changes occurring in response to the sensory rearrangement encountered during orbital flight are primarily studied through second and third order responses. In the Extended Duration Orbiter Medical Project (EDOMP) neuroscience investigations, the following were measured: (1) eye movements during acquisition of either static or moving visual targets, (2) postural and locomotor responses provoked by unexpected movement of the support surface, changes in the interaction of visual, proprioceptive, and vestibular information, changes in the major postural muscles via descending pathways, or changes in locomotor pathways, and (3) verbal reports of perceived self-orientation and self-motion which enhance and complement conclusions drawn from the analysis of oculomotor, postural, and locomotor responses. In spaceflight operations, spatial orientation can be defined as situational awareness, where crew member perception of attitude, position, or motion of the spacecraft or other objects in three-dimensional space, including orientation of one's own body, is congruent with actual physical events. Perception of spatial orientation is determined by integrating information from several sensory modalities. This involves higher levels of processing within the central nervous system that control eye movements, locomotion, and stable posture. Spaceflight operational problems occur when responses to the incorrectly perceived spatial orientation are compensatory in nature. Neuroscience investigations were conducted in conjunction with U. S. Space Shuttle flights to evaluate possible changes in the ability of an astronaut to land the Shuttle or effectively perform an emergency post-landing egress following microgravity adaptation during space flights of variable length. While the results of various sensory motor and spatial orientation tests could have an impact on future space flights, our knowledge of sensorimotor adaptation to spaceflight is limited, and the future application of effective countermeasures depends, in large part, on the results from appropriate neuroscience investigations. Therefore, the objective of the neuroscience investigations could have a negative effect on mission success. The Neuroscience Laboratory, Johnson Space Center (JSC), implemented three integrated Detailed Supplementary Objectives (DSO) designed to investigate spatial orientation and the associated compensatory responses as a part of the EDOMP. The four primary goals were (1) to establish a normative database of vestibular and associated sensory changes in response to spaceflight, (2) to determine the underlying etiology of neurovestibular and sensory motor changes associated with exposure to microgravity and the subsequent return to Earth, (3) to provide immediate feedback to spaceflight crews regarding potential countermeasures that could improve performance and safety during and after flight, and (4) to take under consideration appropriate designs for preflight, in-flight, and postflight countermeasures that could be implemented for future flights.

Reschke, Millard F.↗

Modal Analysis and Correlation of International Space Station Early Configurations

This paper will summarize the modal analysis and model refinement results for the International Space Station (ISS) Flight-2A mated configuration. To maintain structural integrity of the ISS, structural loading distributions have been rigorously analyzed through numerical simulation and taken into account during the design of the structure and mission operations. The accuracy of the analysis results is directly affected by the precision of mathematical models and estimated input forces. A mathematical model of an ISS configuration is composed of individual component math models. Each component model is required to be correlated with ground test data.

Kaouk, Mohamed↗

Multiplexed Cancer Biomarker Detection Using Quartz-based Photonic Crystal Surfaces

A photonic crystal (PC) surface is demonstrated as a high-sensitivity platform for detection of a panel of 21 cancer biomarker antigens using a sandwich enzyme-linked immunosorbent assay (ELISA) microarray format. A quartz-based PC structure fabricated by nanoimprint lithography, selected for its low autofluorescence, supports two independent optical resonances that simultaneously enable enhancement of fluorescence detection of biomarkers and label-free quantification of the density of antibody capture spots. A detection instrument is demonstrated that supports fluorescence and label-free imaging modalities, with the ability to optimize the fluorescence enhancement factor on a pixel-by-pixel basis throughout the microarray using an angle-scanning approach for the excitation laser that automatically compensates for variability in surface chemistry density and capture spot density. Measurements show that the angle-scanning illumination approach reduces the coefficient of variation of replicate assays by 20–99% compared to ordinary fluorescence microscopy, thus supporting reduction in limits of detectable biomarker concentration. Using the PC resonance, biomarkers in mixed samples were detectable at the lowest concentrations tested (2.1–41 pg/mL), resulting in a three-log range of quantitative detection.

Huang, Cheng-Sheng↗

FY2018 Discovery Through Situational Awareness: Anomalies, Oscillations, and Classification

This technical report is a summary of work performed under the DOE GMLC program under the task titled “Discovery through Situational Awareness”. The focus of this work was to apply big data, statistical techniques to PMU data to do the following: 1) baseline PMU data and find anomalies with a focus on phase angle pairs, 2) identify the frequencies of dominant modal oscillations between different parts of a power system, and 3) identify and classify frequency events in PMU data. This work was performed on PMU data from the Western Interconnect. Many of these algorithms will be applied to wide area phase angle pair data on the Eastern Interconnect in a tool called ESAMS (Eastern Interconnect Situational Awareness Monitoring System). ESAMS was built by EPG (Electric Power Group) and PNNL and is currently being installed on the Eastern Interconnect. The results discussed in this report were made from 14 PMUs from data ranging from Oct 2016 to May 2018. The PMU data were measured 60 times each second. Fourteen phase angle pairs were included, with reactive and active power being calculated at 14 sites. All results have been de-identified for this report. The methodologies applied in the ESAMS tool are described in Section 2. A baseline of PMU data is created using the last 120 days of data. This baseline describes typical behavior as understood from the data. The baseline is then applied to the next day’s data and anomalies from that baseline are identified. Plots are created to help describe what is anomalous during that specific moment in time. These algorithms are currently being installed on the Eastern Interconnect. FY19 work will include discussing the results and findings from the ESAMS tool. A new method of identifying the frequencies of dominant modal oscillations between different parts of a power system is described in Section 3. A list of 199 frequency events provided by Bonneville Power Administration were used to create algorithms to detect frequency events and to create classification rules that can be used to identify future frequency events. Section 4 discusses the results the performance of 7 different event detection, clustering-based methods. Accuracy percentages ranged from 93.59% to 99.16%, with most methods being very fast. GBM (Gradient Boosting Machine) performed well and quickly. These 7 different methods were also tested to determine how well each built classification rules on training data and then applied those rules to identify future frequency events. Accuracy percentages ranged from 89.09% to 99.9%, with all methods performing quickly. GLM (General Linear Model) was viewed as the top performer when considering accuracy and processing time. Because the list of events consisted of 80% of them as active power events and only 20% as faults, all methods struggled to identify events as faults. Small faults were especially difficult to identify. A separate algorithm was created to help with this. Additional work will be done in FY19 on event detection using more data and more events and refinements to the methods.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Multi-Bandwidth Frequency Selective Surfaces for Near Infrared Filtering: Design and Optimization

Frequency selective surfaces are widely used in the microwave and millimeter wave regions of the spectrum for filtering signals. They are used in telecommunication systems for multi-frequency operation or in instrument detectors for spectroscopy. The frequency selective surface operation depends on a periodic array of elements resonating at prescribed wavelengths producing a filter response. The size of the elements is on the order of half the electrical wavelength, and the array period is typically less than a wavelength for efficient operation. When operating in the optical region, diffraction gratings are used for filtering. In this regime the period of the grating may be several wavelengths producing multiple orders of light in reflection or transmission. In regions between these bands (specifically in the infrared band) frequency selective filters consisting of patterned metal layers fabricated using electron beam lithography are beginning to be developed. The operation is completely analogous to surfaces made in the microwave and millimeter wave region except for the choice of materials used and the fabrication process. In addition, the lithography process allows an arbitrary distribution of patterns corresponding to resonances at various wavelengths to be produced. The design of sub-millimeter filters follows the design methods used in the microwave region. Exacting modal matching, integral equation or finite element methods can be used for design. A major difference though is the introduction of material parameters and thicknesses tha_ may not be important in longer wavelength designs. This paper describes the design of multi-bandwidth filters operating in the I-5 micrometer wavelength range. This work follows on previous design [1,2]. In this paper extensions based on further optimization and an examination of the specific shape of the element in the periodic cell will be reported. Results from the design, manufacture and test of linear wedge filters built using micro-lithographic techniques and used ir spectral imaging applications will be presented.

Cwik, Tom↗

Variability of Gross Tumor Volume Delineation in Head-and-Neck Cancer Using PET/CT Fusion, Part II: The Impact of a Contouring Protocol

The purpose of this study was to assess the efficacy of a gross tumor volume (GTV) contouring protocol on interobserver variability between 4 physicians in positron emission therapy/computed tomography (PET/CT) treatment planning of head-and-neck cancer. A GTV contouring protocol for PET/CT treatment planning was developed utilizing 4 stages: Preliminary contouring on CT alone, determination of appropriate PET windowing, accurate image registration, and modification of CT contouring with correctly formatted PET/CT display and rules for modality disagreement. Two neuroradiologists and 2 radiation oncologists (designated as A, B, C, and D, respectively) were given a tutorial of PET/CT coregistered imaging individualized to their skill level, which included a step-by-step explanation of the protocol with clinical examples. Opportunities for questions and hands-on practice were given. The physicians were asked to re-contour 16 head-and-neck patients from Part I on PET/CT fusion imaging. Differences in volume magnitude were analyzed for statistical significance by analysis of variance (ANOVA) and paired t-tests ({alpha} < 0.05). Volume overlap was analyzed for statistical significance using Wilcoxon signed-rank tests ({alpha} < 0.05). Volume overlap increased significantly from Part I to Part II (p < 0.05). One previously significant difference between physicians disappeared with the protocol in place. The mean fusion volume of Physician C, however, remained significantly larger than that of Physician D (p < 0.01). This result is unchanged from Part I. The multidisciplinary contouring protocol significantly improved the coincidence of GTVs contoured by multiple physicians. The magnitudes of the volumes showed marginal improvement in consistency. Developing an institutional contouring protocol for PET/CT treatment planning is highly recommended to reduce interobserver variability.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Effective DQE (eDQE) for monoscopic and stereoscopic chest radiography imaging systems with the incorporation of anatomical noise

Purpose: Stereoscopic chest biplane correlation imaging (stereo/BCI) has been proposed as an alternative modality to single view chest x-ray (CXR). The metrics effective modulation transfer function (eMTF), effective normalized noise power spectrum (eNNPS), and effective detective quantum efficiency (eDQE) have been proposed as clinically relevant metrics for assessing clinical system performance taking into consideration the magnification and scatter effects. This study compared the metrics eMTF, eNNPS, eDQE, and detectability index for stereo/BCI and single view CXR under isodose conditions at two magnifications for two anthropomorphic phantoms of differing sizes.Methods: Measurements for the eMTF were taken for two phantom sizes with an opaque edge test device using established techniques. The eNNPS was measured at two isodose conditions for two phantoms using established techniques. The scatter was measured for two phantoms using an established beam stop method. All measurements were also taken at two different magnifications with two phantoms. A geometrical phantom was used for comparison with prior results for CXR although the results for an anatomy free phantom are not expected to vary for BCI.Results: Stereo/BCI resulted in improved metrics compared to single view CXR. Results indicated that magnification can potentially improve the detection performance primarily due to the air gap which reduced scatter by ∼20%. For both phantoms, at isodose, eDQE(0) for stereo/BCI was ∼100 times higher than that for CXR. Magnification at isodose improved eDQE(0) by ∼10 times for stereo/BCI. Increasing the dose did not improve eDQE. The detectability index for stereo/BCI was ∼100 times better than single view CXR for all conditions. The detectability index was also not improved with increased dose.Conclusions: The findings indicate that stereo/BCI with magnification may improve detectability of subtle lung nodules compared to single view CXR. Results were improved with magnification for the smaller phantom but not for the larger phantom. The effective DQE and the detectability index did not improve with increasing dose.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

TU-AB-202-11: Tumor Segmentation by Fusion of Multi-Tracer PET Images Using Copula Based Statistical Methods

Purpose: Multi-tracer PET imaging is getting more attention in radiotherapy by providing additional tumor volume information such as glucose and oxygenation. However, automatic PET-based tumor segmentation is still a very challenging problem. We propose a statistical fusion approach to joint segment the sub-area of tumors from the two tracers FDG and FMISO PET images. Methods: Non-standardized Gamma distributions are convenient to model intensity distributions in PET. As a serious correlation exists in multi-tracer PET images, we proposed a new fusion method based on copula which is capable to represent dependency between different tracers. The Hidden Markov Field (HMF) model is used to represent spatial relationship between PET image voxels and statistical dynamics of intensities for each modality. Real PET images of five patients with FDG and FMISO are used to evaluate quantitatively and qualitatively our method. A comparison between individual and multi-tracer segmentations was conducted to show advantages of the proposed fusion method. Results: The segmentation results show that fusion with Gaussian copula can receive high Dice coefficient of 0.84 compared to that of 0.54 and 0.3 of monomodal segmentation results based on individual segmentation of FDG and FMISO PET images. In addition, high correlation coefficients (0.75 to 0.91) for the Gaussian copula for all five testing patients indicates the dependency between tumor regions in the multi-tracer PET images. Conclusion: This study shows that using multi-tracer PET imaging can efficiently improve the segmentation of tumor region where hypoxia and glucidic consumption are present at the same time. Introduction of copulas for modeling the dependency between two tracers can simultaneously take into account information from both tracers and deal with two pathological phenomena. Future work will be to consider other families of copula such as spherical and archimedian copulas, and to eliminate partial volume effect by considering dependency between neighboring voxels.

60 APPLIED LIFE SCIENCES↗

Test of a model for trace element partition during closed-system solidification of a silicate liquid

Trace-element concentrations in separated minerals and rock fragments from a coarsely crushed and sieved sample of medium-grained lunar basalt are determined by high-precision instrumental neutron activation analysis for three main purposes. These are: (1) to test a previously proposed model for describing trace-element behavior during solidification of a silicate liquid under conditions of a closed system; (2) to compare trace-element concentrations among different size fractions of a comminuted basalt; and (3) to investigate small-scale heterogeneity within a single medium-grained basalt. It is found that an excellent mass balance for the whole rock is attained in terms of the trace-element concentrations of the component minerals and mesostasis, that the mixing model describing this mass balance yields a superior modal analysis for the whole rock, and that different size fractions of the coarsely crushed basalt vary in mineral composition. The closed-system model is shown to account properly for the average behavior of the trace elements during solidification of the basalt, and values of distribution coefficients are obtained for incompatible elements in that rock.

Haskin, L. A.↗

Closed Loop Control Compact Exercise Device for Use on MPCV

Long duration space travel to Mars or to an asteroid will expose astronauts to extended periods of reduced gravity. To combat spaceflight physiological deconditioning, astronauts will use resistive and aerobic exercise regimens for the duration of the space flight to minimize the loss of bone density, muscle mass and aerobic capacity that occurs during exposure to a reduced gravity environment. Unlike the International Space Station (ISS), the mass and volume available for an exercise device in the next generation of spacecraft is limited. Therefore, compact exercise device prototypes are being developed for human in the loop evaluations. The NASA Human Research Program (HRP) is managing Advanced Exercise Concepts (AEC) requirements development and candidate technology maturation for all exploration mission profiles from Multi-Purpose Crew Vehicle (MPCV) exploration missions (e.g., EM-2, up to 21 day) to Mars Transit (up to 1000 day) missions. Numerous technologies have been considered and evaluated against HRP-approved functional requirements and include flywheel, pneumatic and closed-loop microprocessor-controlled motor driven power plants. Motor driven technologies offer excellent torque density and load accuracy characteristics as well as the ability to create custom mechanical impedance (the dynamic relationship between force and velocity) and custom load versus position exercise algorithms. Further, closed-loop motor-driven technologies offer the ability to monitor exercise dose parameters and adapt to the needs of the crewmember for real time optimization of exercise prescriptions. A simple proportional-integral-derivative (PID) controller is demonstrated in a prototype motor driven exercise device with comparison to resistive static and dynamic load set points and aerobic work rate targets. The resistive load term in the algorithm includes a constant force component (Fcmg) as well as inertial component (Fima) and a discussion of system tuning is presented in terms of addressing key functional requirements and human interfaces. The device aerobic modality is modelled as a rowing exercise using ground data sets obtained from Concept 2 rowers as well as competitive rowing1. A discussion of software and electronic implementations are presented which demonstrate unique approaches to meeting the constrained mass, volume and power requirements of the MPCV. . In addition to utilizing traditional PID control, controllers utilizing state feedback with gains solved using a Linear Quadratic Regulator will be developed. Controllability and observability will be utilized to investigate the need for state measurement in the design. As the control system directly interacts with human test subjects, robust methods such as H-infinity are also being investigated.1. Kleshnev V. Biomechanics. In: Rowing, Handbook of Sports Medicine and Science. ed. by Secher N., Voliantis S. IOC Medical Commission, Blackwell Pub. pp. 22-34, 2007

microgravity↗

Impact of Wide-Area Oscillation Damping Control using Measurement-Driven Approach on System Separation - Saudi Grid Case Study

In any interconnected power grid, low-frequency oscillations is a major problem that can limit the power transfer capability and deteriorate power system security due to potential low-damped or even undamped oscillations. Synchronized measurements provided by PMUs enable the design and development of wide-area oscillation damping controllers (WADC) based on measurement-driven model to overcome the limitations of traditional controllers. This work focuses on the impact of a W ADC based on a measurement-driven approach on system separation for the Saudi Electricity Company (SEC) grid. A grid model is provided by SEC for this study. Modal analysis is performed to identify the oscillation mode of interest for which the controller is designed. Damping the dominant oscillation mode helps slightly to improve transient stability of the system. Considering bus frequency at different locations in SEC's system as the candidate observation signals, the optimal observation signal is chosen for the W ADC by using the FFT method. The system transfer function model is constructed by utilizing probing measurements. Then, the W ADC parameters are calculated based on the identified model. The performance of the designed W ADC is tested under different contingencies.

Altarjami, Ibrahim↗

Serum Transforming Growth Factor-β1 Change After Neoadjuvant Chemoradiation Therapy Is Associated With Postoperative Pulmonary Complications in Esophageal Cancer Patients Undergoing Combined Modality Therapy

Purpose: Our aim was to investigate the association of clinical factors, dosimetric parameters, and biomarkers with postoperative pulmonary complications (PPCs) in patients with locally advanced esophageal squamous cell carcinoma (ESCC) treated by neoadjuvant concurrent chemoradiation therapy (CCRT) under strict pulmonary dose constraints and esophagectomy. Methods and Materials: We prospectively enrolled 112 patients undergoing trimodality treatment (including radiation therapy [40 Gy], concurrent taxane-/5-fluorouracil-based regimens, and radical esophagectomy) for ESCC. A PPC was defined as pneumonia or acute respiratory distress syndrome within 30 days after surgery. Serum samples were collected before and within 1 month after CCRT. The association of serum biomarkers with PPCs was detected by proximity ligation assay (PLA) and verified by enzyme-linked immunosorbent assay. Associations of clinical factors, lung dosimetric parameters, and biomarkers with PPC were tested statistically. Results: Thirty-three patients (29.5%) had PPCs. None of the dosimetric parameters was associated with PPCs. Preoperative functional vital capacity (FVC) was significantly associated with PPCs (P=.004). Of the 15 PLA-screened biomarkers, posttreatment transforming growth factor-β1 (TGF-β1) was borderline significantly associated with PPCs (P=.087). Patients with PPCs had significantly larger pre-CCRT to post-CCRT decrease in serum TGF-β1 concentration (−11,310 vs −5332 pg/mL, P=.005) and higher pre-CCRT to post-CCRT percent decline in serum TGF-β1 concentration (−37.4% vs −25.0%, P=.009) than patients without PPCs. On multivariate analysis, preoperative FVC (P=.003) and decrease in TGF-β1 >7040 pg/mL (P=.014) were independent factors associated with PPCs. Conclusions: Preoperative FVC and decrease in serum TGF-β1 level after dose-limited CCRT to the lung are associated with the development of PPCs.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Noninvasive Assessment of Right Ventricular Function in Patients with Pulmonary Arterial Hypertension and Left Ventricular Assist Device

Purpose of Review: Right ventricular (RV) failure in patients with pulmonary arterial hypertension (PAH) and left ventricular assist device (LVAD) is associated with increased hospitalizations, worsening functional class, and poor survival. Accurate RV function assessment is essential in diagnosing RV failure, guiding therapies, and determining prognosis. Noninvasive imaging techniques provide fast and reliable quantification of RV morphology and function. Recent Findings: We review echocardiography, nuclear medicine, and cardiac magnetic resonance imaging (MRI) uses for RV function assessment in patients with PAH and LVAD. We identify current knowledge gaps in utilizing noninvasive tests to assess RV function. Summary: Echocardiography is most widely used to quantify RV function in patients with PAH and LVAD, followed by cardiac MRI for RV morphology and function measurement in PAH patients. The first-pass radionuclide angiography with radiolabeled RBC is the gold standard for calculating RV function. Gated blood pool SPECT can be an alternative as it separates the cardiac chambers well and provides accurate assessment of the RV function with high reproducibility, which is particularly useful for monitoring treatment. More research is needed to compare and validate these modalities in evaluating RV function.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Predicting 3D Motions from Single-Camera Optical Test Data

In a typical optical test, a stereo camera pair is required to measure the three-dimensional motion of a test article; one camera typically only measures motions in the image plane of the camera, and measurements in the out-of-plane direction are missing. Finite element expansion techniques provide a path to estimate responses from a test at unmeasured degrees of freedom. Treating the case of a single camera as a measurement with unmeasured degrees of freedom, a finite element model is used to expand to the missing third dimension of the image data, allowing a full-field, three-dimensional measurement to be obtained from a set of images from a single camera. The key to this technique relies on the mapping of finite element deformations to image deformations, creating a set of mode shape images that are used to filter the response in the image into modal responses. These modal responses are then applied to the finite element model to estimate physical responses at all finite element model degrees of freedom. The mapping from finite element model to image is achieved using synthetic images produced by a rendering software. Finally, the technique is applied first to a synthetic deformation image, and then is validated using an experimental set of images.

47 OTHER INSTRUMENTATION↗

Comparison study of the partial-breast irradiation techniques: Dosimetric analysis of three-dimensional conformal radiation therapy, electron beam therapy, and helical tomotherapy depending on various tumor locations

The partial-breast irradiation (PBI) technique, an alternative to whole-breast irradiation, is a beam delivery method that uses a limited range of treatment volume. The present study was designed to determine the optimal PBI treatment modalities for 8 different tumor locations. Treatment planning was performed on computed tomography (CT) data sets of 6 patients who had received lumpectomy treatments. Tumor locations were classified into 8 subsections according to breast quadrant and depth. Three-dimensional conformal radiation therapy (3D-CRT), electron beam therapy (ET), and helical tomotherapy (H-TOMO) were utilized to evaluate the dosimetric effect for each tumor location. Conformation number (CN), radical dose homogeneity index (rDHI), and dose delivered to healthy tissue were estimated. The Kruskal-Wallis, Mann-Whitney U, and Bonferroni tests were used for statistical analysis. The ET approach showed good sparing effects and acceptable target coverage for the lower inner quadrant—superficial (LIQ-S) and lower inner quadrant—deep (LIQ-D) locations. The H-TOMO method was the least effective technique as no evaluation index achieved superiority for all tumor locations except CN. The ET method is advisable for treating LIQ-S and LIQ-D tumors, as opposed to 3D-CRT or H-TOMO, because of acceptable target coverage and much lower dose applied to surrounding tissue.

61 RADIATION PROTECTION AND DOSIMETRY↗

Unsteady design-point flow phenomena in transonic compressors

High-frequency response probes which had previously been used exclusively in the MIT Blowndown Facility were successfully employed in two conventional steady state axial flow compressor facilities to investigate the unsteady flowfields of highly loaded transonic compressors at design point operation. Laser anemometry measurements taken simultaneously with the high response data were also analyzed. The time averaged high response data of static and total pressure agreed quite well with the conventional steady state instrumentation except for flow angle which showed a large spread in values at all radii regardless of the type of instrumentation used. In addition, the time resolved measurements confirmed earlier test results obtained in the MIT Blowdown Facility for the same compressor. The results of these tests have further revealed that the flowfields of highly loaded transonic compressors are heavily influenced by unsteady flow phenomena. The high response measurements exhibited large variations in the blade to blade flow and in the blade passage flow. The observed unsteadiness in the blade wakes is explained in terms of the rotor blades' shed vorticity in periodic vortex streets. The wakes were modeled as two-dimensional vortex streets with finite size cores. The model fit the data quite well as it was able to reproduce the average wake shape and bi-modal probability density distributions seen in the laser anemometry data. The presence of vortex streets in the blade wakes also explains the large blade to blade fluctuations seen by the high response probes which is simply due to the intermittent sampling of the vortex street as it is swept past a stationary probe.

Gertz, J. B.↗