Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Modal Analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,405 records · Page 78

SU-E-T-01: (In)dependence of Plan Quality On Treatment Modalities and Target-To-Critical Structure Geometry for Brain Tumor

Purpose: To evaluate and test the hypothesis that plan quality may be systematically affected by treatment delivery techniques and target-tocritical structure geometric relationship in radiotherapy for brain tumor. Methods: Thirty-four consecutive brain tumor patients treated between 2011–2014 were analyzed. Among this cohort, 10 were planned with 3DCRT, 11 with RadipArc, and 13 with helical IMRT on TomoTherapy. The selected dosimetric endpoints (i.e., PTV V100, maximum brainstem/chiasm/ optic nerve doses) were considered as a vector in a highdimensional space. A Pareto analysis was performed to identify the subset of Pareto-efficient plans.The geometric relationships, specifically the overlapping volume and centroid-of-mass distance between each critical structure to the PTV were extracted as potential geometric features. The classification-tree analyses were repeated using these geometric features with and without the treatment modality as an additional categorical predictor. In both scenarios, the dominant features to prognosticate the Pareto membership were identified and the tree structures to provide optimal inference were recorded. The classification performance was further analyzed to determine the role of treatment modality in affecting plan quality. Results: Seven Pareto-efficient plans were identified based on dosimetric endpoints (3 from 3DCRT, 3 from RapicArc, 1 from Tomo), which implies that the evaluated treatment modality may have a minor influence on plan quality. Classification trees with/without the treatment modality as a predictor both achieved accuracy of 88.2%: with 100% sensitivity and 87.1% specificity for the former, and 66.7% sensitivity and 96.0% specificity for the latter. The coincidence of accuracy from both analyses further indicates no-to-weak dependence of plan quality on treatment modality. Both analyses have identified the brainstem to PTV distance as the primary predictive feature for Pareto-efficiency. Conclusion: Pareto evaluation and classification-tree analyses have indicated that plan quality depends strongly on geometry for brain tumor, specifically PTV-tobrain-stem-distance but minimally on treatment modality.

60 APPLIED LIFE SCIENCES↗

Aerosol Complexity and Implications for Predictability and Short-Term Forecasting

There are clear NWP and climate impacts from including aerosol radiative and cloud interactions. Changes in dynamics and cloud fields affect aerosol lifecycle, plume height, long-range transport, overall forcing of the climate system, etc. Inclusion of aerosols in NWP systems has benefit to surface field biases (e.g., T2m, U10m). Including aerosol affects has impact on analysis increments and can have statistically significant impacts on, e.g., tropical cyclogenesis. Above points are made especially with respect to aerosol radiative interactions, but aerosol-cloud interaction is a bigger signal on the global system. Many of these impacts are realized even in models with relatively simple (bulk) aerosol schemes (approx.10 -20 tracers). Simple schemes though imply simple representation of aerosol absorption and importantly for aerosol-cloud interaction particle-size distribution. Even so, more complex schemes exhibit a lot of diversity between different models, with issues such as size selection both for emitted particles and for modes. Prospects for complex sectional schemes to tune modal (and even bulk) schemes toward better selection of size representation. I think this is a ripe topic for more research -Systematic documentation of benefits of no vs. climatological vs. interactive (direct and then direct+indirect) aerosols. Document aerosol impact on analysis increments, inclusion in NWP data assimilation operator -Further refinement of baseline assumptions in model design (e.g., absorption, particle size distribution). Did not get into model resolution and interplay of other physical processes with aerosols (e.g., moist physics, obviously important), chemistry

Predictability↗

Distant Metastases Following Permanent Interstitial Brachytherapy for Patients With Clinically Localized Prostate Cancer

Purpose: Recent publications have suggested high-risk patients undergoing radical prostatectomy have a lower risk of distant metastases and improved cause-specific survival (CSS) than patients receiving definitive external beam radiation therapy (XRT). To date, none of these studies has compared distant metastases and CSS in brachytherapy patients. In this study, we evaluate such parameters in a consecutive cohort of brachytherapy patients. Methods and Materials: From April 1995 to June 2007, 1,840 consecutive patients with clinically localized prostate cancer were treated with brachytherapy. Risk groups were stratified according to National Comprehensive Cancer Network ( (www.nccn.org)) guidelines. Subgroups of 658, 893, and 289 patients were assigned to low, intermediate, and high-risk categories. Median follow-up was 7.2 years. Along with brachytherapy implantation, 901 (49.0%) patients received supplemental XRT, and 670 (36.4%) patients received androgen deprivation therapy (median duration, 4 months). The mode of failure (biochemical, local, or distant) was determined for each patient for whom therapy failed. Cause of death was determined for each deceased patient. Multiple parameters were evaluated for impact on outcome. Results: For the entire cohort, metastases-free survival (MFS) and CSS at 12 years were 98.1% and 98.2%, respectively. When rates were stratified by low, intermediate, and high-risk groups, the 12-year MFS was 99.8%, 98.1%, and 93.8% (p < 0.001), respectively. CSS rates were 99.8%, 98.0%, and 95.3% (p < 0.001) for low, intermediate, and high-risk groups, respectively. Biochemical progression-free survival was 98.7%, 95.9% and 90.4% for low, intermediate, and high-risk patients, respectively (p < 0.001). In multivariate Cox-regression analysis, MFS was mostly closely related to Gleason score and year of treatment, whereas CSS was most closely associated with Gleason score. Conclusions: Excellent CSS and MFS rates are achievable with high-quality brachytherapy for low, intermediate, and high-risk patients. These results compare favorably to alternative treatment modalities. In particular, our MFS and CSS rates for high-risk patients appear superior to those of published radical prostatectomy series.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Framework for Structural Online Health Monitoring of Aging and Degradation of Secondary Systems due to some Aspects of Erosion

This report describes the current state of research related to critical aspects of erosion and selected aspects of degradation of secondary components in nuclear power plants. The report also proposes a framework for online health monitoring of aging and degradation of secondary components. The framework consists of an integrated multi-sensor modality system which can be used to monitor different piping configurations under different degradation conditions. The report analyses the currently known degradation mechanisms and available predictive models. Based on this analysis, the structural health monitoring framework is proposed. The Light Water Reactor Sustainability Program began to evaluate technologies that could be used to perform online monitoring of piping and other secondary system structural components in commercial NPPs. These online monitoring systems have the potential to identify when a more detailed inspection is needed using real-time measurements, rather than at a pre-determined inspection interval. This transition to condition-based, risk informed automated maintenance will contribute to a significant reduction of operations and maintenance costs that account for the majority of nuclear power generation costs. There is unanimous agreement between industry experts and academic researchers that identifying and prioritizing inspection locations in secondary piping systems (for example, in raw water piping or diesel piping) would eliminate many excessive in-service inspections. The proposed structural health monitoring framework takes aim at answering this challenge by combining long-range guided wave technologies with other monitoring techniques, which can significantly increase the inspection length and pinpoint the locations that degraded the most. More widely, the report suggests research efforts aimed at developing, validating, and deploying online corrosion monitoring techniques for complex geometries, which are pervasive in NPPs.

47 OTHER INSTRUMENTATION↗

FRAMEWORK FOR STRUCTURAL ONLINE HEALTH MONITORING OF AGING AND DEGRADATION OF SECONDARY PIPING SYSTEMS DUE TO SOME ASPECTS OF EROSION

This paper describes the current state of research related to critical aspects of erosion and selected aspects of degradation of secondary components in nuclear power plants (NPPs). The paper also proposes a framework for online health monitoring of aging and degradation of secondary components. The framework consists of an integrated multi-sensor modality system, which can be used to monitor different piping configurations under different degradation conditions. The report analyses the currently known degradation mechanisms and available predictive models. Based on this analysis, the structural health monitoring framework is proposed. The Light Water Reactor Sustainability Program began to evaluate technologies that could be used to perform online monitoring of piping and other secondary system structural components in commercial NPPs. These online monitoring systems have the potential to identify when a more detailed inspection is needed using real time measurements, rather than at a pre-determined inspection interval. This transition to condition-based, risk-informed automated maintenance will contribute to a significant reduction of operations and maintenance costs that account for the majority of nuclear power generation costs. Furthermore, of the operations and maintenance costs in U.S. plants, approximately 80% are labor costs. To address the issue of rising operating costs and economic viability, in 2017, companies that operate the national nuclear energy fleet started the Delivering the Nuclear Promise Initiative, which is a 3 year program aimed at maintaining operational focus, increasing value, and improving efficiency. There is unanimous agreement between industry experts and academic researchers that identifying and prioritizing inspection locations in secondary piping systems (for example, in raw water piping or diesel piping) would eliminate many excessive in-service inspections. The proposed structural health monitoring framework takes aim at answering this challenge by combining long range guided wave technologies with other monitoring techniques, which can significantly increase the inspection length and pinpoint the locations that degraded the most. More widely, the report suggests research efforts aimed at developing, validating, and deploying online corrosion monitoring techniques for complex geometries, which are pervasive in NPPs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-G-TeP1-09: Modality-Specific Dose Gradient Modeling for Prostate IMRT Using Spherical Distance Maps of PTV and Isodose Contours

Purpose: Overlapping volume histogram (OVH) and distance-to-target histogram (DTH) calculations rely on the assumption that dose gradients are symmetric with respect to primary target volume (PTV) expansion and minimum distance to PTV surface, respectively. It is desirable to lift this assumption and instead account for achievable modality-specific dose gradients (MSDG) for a given PTV shape. Methods: From a library of 96 prostate 7-beam IMRT plans, we computed spherical distance maps (SDMs) for PTVs and 3 iso-dose contours. Each SDM contains the minimum distances between plan isocenter and the object’s surface for a fixed set of azimuthal and polar angles. We performed principal component analysis (PCA)-based missing data recovery with PTV SDM as input and a single iso-dose contour SDM as output. Repeating this process for the set of iso-dose contours sparsely reconstructed the MSDG for a given PTV. DVH points were computed from the MSDG for bladder and rectum (OARs) as a natural way of casting patient-specific geometric information into modality-specific dose space (vs. OVH and DTH where data is purely geometric). For comparison, we implemented a cumulative (c)DTH-based prediction algorithm, and produced DVH for both OARs separately. We then computed linear regressions between each method and the DVH of the original patient plan for three different OAR DVH points. Results: R-squared for MSD-Gcomputed DVH vs. original plan DVH at V90%, V80% and V60% of max dose were 0.86, 0.83, and 0.78, for bladder and 0.36, 0.52, and 0.55 for rectum, respectively; R-squared for cDTH-based predicted DVH vs. original plan DVH were 0.67, 0.81, and 0.83, for bladder and 0.44, 0.50, and 0.51, for rectum, respectively. Conclusion: By simply modeling the MSDG about a given PTV, we are able to reproduce DVHs consistent with a validated cDTH-based DVH prediction. Regression analysis suggests MSDG could further improve predictions.

60 APPLIED LIFE SCIENCES↗

Analysis of electrically conductive adhesives in shingled solar modules by X-ray imaging techniques

The failure mechanisms of electrically conductive adhesives (ECAs) in solar modules are difficult to study since the ECA layer is not easily accessible within the module package. In this work, we present two complementary imaging modalities—X-ray radiography and X-ray microcomputed tomography (XCT)—that reveal important morphological features of the ECA within a shingled module. X-ray radiography uses single X-ray projections to provide fast and non-destructive imaging of the shingled interconnection, illuminating the alignment of the ECA relative to the busbars, the size and shape of the ECA, and the presence of voids within it. Through X-ray radiography, we observed, for example, that the average void coverage area of ECA segments reduced from 36.7% to 4.4% when an ECA was cured for 60 s prior to module lamination. XCT is a three-dimensional imaging technique that can identify regions in which the ECA makes electrical contact to busbars on cells and regions in which the ECA has cracked, among other features. XCT can also be used to image the individual metal particles within ECA, from which the metal volume fraction of an ECA was found here to be 70.4%. This is a quantity that is not often reported by ECA manufacturers but is important to ensure isotropic conduction. As X-ray projections can be performed non-destructively on full modules, the technique may be used to pinpoint ECA failures in accelerated degradation testing. XCT is complementary and is suited to forensic analysis of failing modules.

14 SOLAR ENERGY↗

Rapid iterative reanalysis for automated design

A method for iterative reanalysis in automated structural design is presented for a finite-element analysis using the direct stiffness approach. A basic feature of the method is that the generalized stiffness and inertia matrices are expressed as functions of structural design parameters, and these generalized matrices are expanded in Taylor series about the initial design. Only the linear terms are retained in the expansions. The method is approximate because it uses static condensation, modal reduction, and the linear Taylor series expansions. The exact linear representation of the expansions of the generalized matrices is also described and a basis for the present method is established. Results of applications of the present method to the recalculation of the natural frequencies of two simple platelike structural models are presented and compared with results obtained by using a commonly applied analysis procedure used as a reference. In general, the results are in good agreement. A comparison of the computer times required for the use of the present method and the reference method indicated that the present method required substantially less time for reanalysis. Although the results presented are for relatively small-order problems, the present method will become more efficient relative to the reference method as the problem size increases. An extension of the present method to static reanalysis is described, ana a basis for unifying the static and dynamic reanalysis procedures is presented.

Bhatia, K. G.↗

Impact of Insurance Status on Radiation Treatment Modality Selection Among Potential Candidates for Prostate, Breast, or Gynecologic Brachytherapy

Purpose: The Patient Protection and Affordable Care Act looks to expand both private and Medicaid insurance. To evaluate how these changes may affect the field of radiation oncology, we evaluated the association of insurance status with the use of brachytherapy in cancers for which this treatment technique is used. Methods and Materials: A total of 190,467 patients met the inclusion criteria, of whom 95,292 (50.0%) had breast cancer, 61,096 (32.1%) had prostate cancer, 28,194 (14.8%) had endometrial cancer, and 5885 (3.1%) had cervical cancer. A multivariate logistic regression model was used to determine the association between insurance status and receipt of brachytherapy among patients treated definitively for prostate and cervical cancer or postoperatively for breast and endometrial cancer. Results: The rates of non-Medicaid insurance were 49.9% (cervical), 85.3% (endometrial), 87.4% (breast), and 90.9% (prostate) (P<.001). In a logistic regression, patients who received radiation therapy were less likely to receive brachytherapy if they had Medicaid coverage (odds ratio [OR] 0.57, 95% confidence interval [CI] 0.53-0.61, P<.001) or did not have insurance coverage (OR 0.50, 95% CI 0.45-0.56, P<.001) compared with those with non-Medicaid insurance. On subset analysis, patients with Medicaid coverage or without insurance coverage were significantly less likely to receive brachytherapy than were those with non-Medicaid insurance for all 4 sites, except for patients with endometrial cancer. Conclusions: Despite being a cost-effective treatment modality, brachytherapy is less often used in the definitive or postoperative management of cancer in patients with Medicaid coverage or without insurance. Upcoming health policy changes resulting in the expansion of private insurance and Medicaid will likely increase access to and demand for brachytherapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Aerodynamically forced vibration analysis of turbomachines

An account is given of theoretical considerations for the determination of turbomachine response under aerodynamic excitation, as in the cases of advanced turboprop rotors with highly swept blades and axial flow compressors. Dynamic response is characterized in terms of the normal modal coordinates of tuned rotating cyclic structures for both rigid and flexible hubs/disks. Implementation of the scheme is in NASTRAN; coriolis and centripetal accelerations are included, together with differential stiffness effects. Analytically predicted vibratory stresses for the blades of two different advanced turboprops are compared to those determined by wind tunnel tests conducted by NASA-Lewis.

Elchuri, V.↗

Operational Analysis in the Launch Environment

The launch environment is a challenging regime to work due to changing system dynamics, changing environmental loading, joint compression loads that cannot be easily applied on the ground, and control effects. Operational testing is one of the few feasible approaches to capture system level dynamics since ground testing cannot reproduce all of these conditions easily. However, the most successful applications of Operational Modal Testing involve systems with good stationarity and long data acquisition times. This paper covers an ongoing effort to understand the launch environment and the utility of current operational modal tools. This work is expected to produce a collection of operational tools that can be applied to non-stationary launch environment, experience dealing with launch data, and an expanding database of flight parameters such as damping. This paper reports on recent efforts to build a software framework for the data processing utilizing existing and specialty tools; understand the limits of current tools; assess a wider variety of current tools; and expand the experience with additional datasets as well as to begin to address issues raised in earlier launch analysis studies.

James, George↗

Proton Beam Therapy and Concurrent Chemotherapy for Esophageal Cancer

Purpose: Proton beam therapy (PBT) is a promising modality for the management of thoracic malignancies. We report our preliminary experience of treating esophageal cancer patients with concurrent chemotherapy (CChT) and PBT (CChT/PBT) at MD Anderson Cancer Center. Methods and Materials: This is an analysis of 62 esophageal cancer patients enrolled on a prospective study evaluating normal tissue toxicity from CChT/PBT from 2006 to 2010. Patients were treated with passive scattering PBT with two- or three-field beam arrangement using 180 to 250 MV protons. We used the Kaplan-Meier method to assess time-to-event outcomes and compared the distributions between groups using the log-rank test. Results: The median follow-up time was 20.1 months for survivors. The median age was 68 years (range, 38-86). Most patients were males (82%) who had adenocarcinomas (76%) and Stage II-III disease (84%). The median radiation dose was 50.4 Gy (RBE [relative biologic equivalence]) (range, 36-57.6). The most common grade 2 to 3 acute toxicities from CChT/PBT were esophagitis (46.8%), fatigue (43.6%), nausea (33.9%), anorexia (30.1%), and radiation dermatitis (16.1%). There were two cases of grade 2 and 3 radiation pneumonitis and two cases of grade 5 toxicities. A total of 29 patients (46.8%) received preoperative CChT/PBT, with one postoperative death. The pathologic complete response (pCR) rate for the surgical cohort was 28%, and the pCR and near CR rates (0%-1% residual cells) were 50%. While there were significantly fewer local-regional recurrences in the preoperative group (3/29) than in the definitive CChT/PBT group (16/33) (log-rank test, p = 0.005), there were no differences in distant metastatic (DM)-free interval or overall survival (OS) between the two groups. Conclusions: This is the first report of patients treated with PBT/CChT for esophageal cancer. Our data suggest that this modality is associated with a few severe toxicities, but the pathologic response and clinical outcomes are encouraging. Prospective comparison with more traditional approach is warranted.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

WE-AB-207B-07: Dose Cloud: Generating “Big Data” for Radiation Therapy Treatment Plan Optimization Research

Purpose: To provide a tool to generate large sets of realistic virtual patient geometries and beamlet doses for treatment optimization research. This tool enables countless studies exploring the fundamental interplay between patient geometry, objective functions, weight selections, and achievable dose distributions for various algorithms and modalities. Methods: Generating realistic virtual patient geometries requires a small set of real patient data. We developed a normalized patient shape model (PSM) which captures organ and target contours in a correspondence-preserving manner. Using PSM-processed data, we perform principal component analysis (PCA) to extract major modes of variation from the population. These PCA modes can be shared without exposing patient information. The modes are re-combined with different weights to produce sets of realistic virtual patient contours. Because virtual patients lack imaging information, we developed a shape-based dose calculation (SBD) relying on the assumption that the region inside the body contour is water. SBD utilizes a 2D fluence-convolved scatter kernel, derived from Monte Carlo simulations, and can compute both full dose for a given set of fluence maps, or produce a dose matrix (dose per fluence pixel) for many modalities. Combining the shape model with SBD provides the data needed for treatment plan optimization research. Results: We used PSM to capture organ and target contours for 96 prostate cases, extracted the first 20 PCA modes, and generated 2048 virtual patient shapes by randomly sampling mode scores. Nearly half of the shapes were thrown out for failing anatomical checks, the remaining 1124 were used in computing dose matrices via SBD and a standard 7-beam protocol. As a proof of concept, and to generate data for later study, we performed fluence map optimization emphasizing PTV coverage. Conclusions: We successfully developed and tested a tool for creating customizable sets of virtual patients suitable for large-scale radiation therapy optimization research.

60 APPLIED LIFE SCIENCES↗

Initial transport and turbulence analysis and gyrokinetic simulation validation in NSTX-U L-mode plasmas

Transport analysis, ion-scale turbulence measurements, and initial linear and nonlinear gyrokinetic simulations are reported for a transport validation study based on low aspect ratio NSTX-U L-mode discharges. The relatively long, stationary L-modes enabled by the upgraded centerstack provide a more ideal target for transport validation studies that were not available during NSTX operation. Transport analysis shows that anomalous electron transport dominates energy loss while ion thermal transport is well described by neoclassical theory. Linear gyrokinetic GYRO analysis predicts that ion temperature gradient (ITG) modes are unstable around normalized radii ρ=0.6-0.8, although E×B shearing rates are larger than the linear growth rates over much of that region. Deeper in the core (ρ=0.4-0.6), electromagnetic microtearing modes (MTM) are unstable as a consequence of the relatively high beta and collisionality in these particular discharges. Consistent with the linear analysis, local, nonlinear ion-scale GYRO simulations predict strong ITG transport at ρ=0.76, whereas electromagnetic MTM transport is important at ρ=0.47. The prediction of ion-scale turbulence is consistent with 2D beam emission spectroscopy (BES) that measures the presence of broadband ion-scale fluctuations. Interestingly, the BES measurements also indicate the presence of bi-modal poloidal phase velocity propagation that could be indicative of two different turbulence types. Furthermore, in the region between (ρ=0.56, 0.66), ion-scale simulations are strongly suppressed by the locally large E×B shear. Instead, electron temperature gradient (ETG) turbulence simulations predict substantial transport, illustrating electron-scale contributions can be important in low aspect ratio L-modes, similar to recent analysis at conventional aspect ratio. However, agreement within experimental uncertainties has not been demonstrated, which requires additional simulations to test parametric sensitivities. The potential need to include profile-variation effects (due to the relatively large value of ρ&lowast;=ρ i /a at low aspect ratio), including electromagnetic and possibly multi-scale effects, is also discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Initial transport and turbulence analysis and gyrokinetic simulation validation in NSTX-U L-mode plasmas

Transport analysis, ion-scale turbulence measurements, and initial linear and nonlinear gyrokinetic simulations are reported for a transport validation study based on low aspect ratio NSTX-U L-mode discharges. The relatively long, stationary L-modes enabled by the upgraded centerstack provide a more ideal target for transport validation studies that were not available during NSTX operation. Transport analysis shows that anomalous electron transport dominates energy loss while ion thermal transport is well described by neoclassical theory. Linear gyrokinetic GYRO analysis predicts that ion temperature gradient (ITG) modes are unstable around normalized radii $\rho$=0.6-0.8, although $E\timesB$ shearing rates are larger than the linear growth rates over much of that region. Deeper in the core ($\rho$=0.4-0.6), electromagnetic microtearing modes (MTM) are unstable as a consequence of the relatively high beta and collisionality in these particular discharges. Consistent with the linear analysis, local, nonlinear ion-scale GYRO simulations predict strong ITG transport at $\rho$=0.76, whereas electromagnetic MTM transport is important at $\rho$=0.47. The prediction of ion-scale turbulence is consistent with 2D beam emission spectroscopy (BES) that measures the presence of broadband ion-scale fluctuations. Interestingly, the BES measurements also indicate the presence of bi-modal poloidal phase velocity propagation that could be indicative of two different turbulence types. However, in the region between ($\rho$=0.56, 0.66), ion-scale simulations are strongly suppressed by the locally large $E\timesB$ shear. Instead, electron temperature gradient (ETG) turbulence simulations predict substantial transport, illustrating electron-scale contributions can be important in low aspect ratio L-modes, similar to recent analysis at conventional aspect ratio. However, agreement within experimental uncertainties has not been demonstrated, which requires additional simulations to test parametric sensitivities. The potential need to include profile-variation effects (due to the relatively large value of $\rho_*$=$\rho_i$/a at low aspect ratio), including electromagnetic and possibly multi-scale effects, is also discussed.

Validation↗

Microstructurally resolved electrochemical evolution of mechanical- and irradiation-induced damage in nuclear alloys

Abstract There is a need for high-throughput, scale-relevant, and direct electrochemical analysis to understand the corrosion behavior and sensitivity of nuclear materials that are exposed to extreme (high pressure, temperature, and radiation exposure) environments. We demonstrate the multi-scale, multi-modal application of scanning electrochemical cell microscopy (SECCM) to electrochemically profile corrosion alterations in nuclear alloys in a microstructurally resolved manner. Particularly, we identify that both mechanically deformed and irradiated microstructures show reduced charge-transfer resistance that leads to accelerated oxidation. We highlight that the effects of mechanical deformation and irradiation are synergistic, and may in fact, superimpose each other, with implications including general-, galvanic-, and/or irradiation-activated stress-corrosion cracking. Taken together, we highlight the ability of non-destructive, electrochemical interrogations to ascertain how microstructural alterations result in changes in the corrosion tendency of a nuclear alloy: knowledge which has implications to rank, qualify and examine alloys for use in nuclear construction applications.

Chen, Xin↗

Mshock HED Council Request FY24 [Slides]

ICF and HEDP experiments experience complicated loadings including successive shocks, but modeling and analytic work has mostly engaged the simpler shock or shock-reshock case. This is because the co propagating case is difficult to achieve with conventional (non-HED) drivers. Successive shocks will be challenging to model in BHR or modal model interpretations: 1) Ex: Consider the case where long wavelength modes re-invert coherently, but short wavelength nonlinear modes are spun up turbulently. 2) Necessitates more advanced diagnostics and analysis than simple “mixing layers.” High resolution spectral information (concomitant with Ω-EP campaigns) and higher-order moment analyses will be necessary to stress and validate the reduced BHR-type models.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗