Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Modal”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,405 records · Page 78

Revealing Nanoscale Chemical Heterogeneities in Polycrystalline Mo-BiVO 4 Thin Films

The activity of polycrystalline thin film photoelectrodes is impacted by local variations of the material properties due to the exposure of different crystal facets and the presence of grain/domain boundaries. Here a multi-modal approach is applied to correlate nanoscale heterogeneities in chemical composition and electronic structure with nanoscale morphology in polycrystalline Mo-BiVO 4 . By using scanning transmission X-ray microscopy, the characteristic structure of polycrystalline film is used to disentangle the different X-ray absorption spectra corresponding to grain centers and grain boundaries. Comparing both spectra reveals phase segregation of V 2 O 5 at grain boundaries of Mo-BiVO 4 thin films, which is further supported by X-ray photoelectron spectroscopy and many-body density functional theory calculations. Theoretical calculations also enable to predict the X-ray absorption spectral fingerprint of polarons in Mo-BiVO 4 . After photo-electrochemical operation, the degraded Mo-BiVO 4 films show similar grain center and grain boundary spectra indicating V 2 O 5 dissolution in the course of the reaction. Overall, these findings provide valuable insights into the degradation mechanism and the impact of material heterogeneities on the material performance and stability of polycrystalline photoelectrodes.

36 MATERIALS SCIENCE↗

Nanoscale Imaging and Control of Volatile and Non-Volatile Resistive Switching in VO 2

Control of the metal-insulator phase transition is vital for emerging neuromorphic and memristive technologies. The ability to alter the electrically driven transition between volatile and non-volatile states is particularly important for quantum-materials-based emulation of neurons and synapses. The major challenge of this implementation is to understand and control the nanoscale mechanisms behind these two fundamental switching modalities. In this study, in situ X-ray nanoimaging is used to follow the evolution of the nanostructure and disorder in the archetypal Mott insulator VO 2 during an electrically driven transition. Our findings demonstrate selective and reversible stabilization of either the insulating or metallic phases achieved by manipulating the defect concentration. This mechanism enables us to alter the local switching response between volatile and persistent regimes and demonstrates a new possibility for nanoscale control of the resistive switching in Mott materials.

36 MATERIALS SCIENCE↗

Hollow Ptychography: Toward Simultaneous 4D Scanning Transmission Electron Microscopy and Electron Energy Loss Spectroscopy

With the recent development of high-acquisition-speed pixelated detectors, 4D scanning transmission electron microscopy (4D-STEM) is becoming routinely available in high-resolution electron microscopy. 4D-STEM acts as a “universal” method that provides local information on materials that is challenging to extract from bulk techniques. It extends conventional STEM imaging to include super-resolution techniques and to provide quantitative phase-based information, such as differential phase contrast, ptychography, or Bloch wave phase retrieval. However, an important missing factor is the chemical and bonding information provided by electron energy loss spectroscopy (EELS). 4D-STEM and EELS cannot currently be acquired simultaneously due to the overlapping geometry of the detectors. Here, the feasibility of modifying the detector geometry to overcome this challenge for bulk specimens is demonstrated, and the use of a partial or defective detector for ptycholgaphic structural imaging is explored. Here, results show that structural information beyond the diffraction-limit and chemical information from the material can be extracted together, resulting in simultaneous multi-modal measurements, adding the additional dimensions of spectral information to 4D datasets.

4D-scanning transmitting electron microscopy (STEM↗

Nozzle-Free Printing of CNT Electronics Using Laser-Generated Focused Ultrasound

Printed electronics have made remarkable progress in recent years and inkjet printing (IJP) has emerged as one of the leading methods for fabricating printed electronic devices. However, challenges such as nozzle clogging, and strict ink formulation constraints have limited their widespread use. To address this issue, a novel nozzle-free printing technology is explored, which is enabled by laser-generated focused ultrasound, as a potential alternative printing modality called Shock-wave Jet Printing (SJP). Specifically, the performance of SJP-printed and IJP-printed bottom-gated carbon nanotube (CNT) thin film transistors (TFTs) is compared. While IJP required ten print passes to achieve fully functional devices with channel dimensions ranging from tens to hundreds of micrometers, SJP achieved comparable performance with just a single pass. For optimized devices, SJP demonstrated six times higher maximum mobility than IJP-printed devices. Furthermore, the advantages of nozzle-free printing are evident, as SJP successfully printed stored and unsonicated inks, delivering moderate electrical performance, whereas IJP suffered from nozzle clogging due to CNT agglomeration. Moreover, SJP can print significantly longer CNTs, spanning the entire range of tube lengths of commercially available CNT ink. The findings from this study contribute to the advancement of nanomaterial printing, ink formulation, and the development of cost-effective printable electronics.

47 OTHER INSTRUMENTATION↗

Multi‐fidelity digital twin structural model for a sub‐scale downwind wind turbine rotor blade

Abstract This paper presents the development of a multi‐fidelity digital twin structural model (virtual model) of an as‐built wind turbine blade. The goal is to develop and demonstrate an approach to produce an accurate and detailed model of the as‐built blade for use in verifying the performance of the operating two‐bladed, downwind rotor. The digital twin model development methodology, presented herein, involves a novel calibration process to integrate a wide range of information including design specifications, manufacturing information, and structural testing data (modal and static) to produce a multi‐fidelity digital twin structural model: a detailed high‐fidelity model (i.e., 3D finite element analysis [FEA]) and consistent beam‐type models for aeroelastic simulation. A key element is that the multi‐fidelity structural digital twin method follows the rotor from the stages of design, to manufacturing, then to the ground testing and field operation. The result of this comprehensive approach is an accurate multi‐fidelity digital twin structural model for the geometric, structural, and structural dynamic properties of the as‐built blade within a 1% match in mass properties, 3.2% in blade frequencies, and 6% in deflection. The different stages of processing this information within the methodology are discussed. The rotor examined is the SUMR‐Demonstrator (SUMR‐D), which was installed on the Controls Advanced Research Testbed (CART‐2) wind turbine at the National Wind Technology Center. The digital twin model developed here was utilized to design controllers to safely operate SUMR‐D in field tests, which are providing additional data for further evaluation and development of the multi‐fidelity digital twin structural model.

Chetan, Mayank↗

Squeeze Film Damper Experimental and Numerical Correlation: Test Setup Description and Parameter Identification of Dry System

The process of characterizing a damper involves both experimental techniques and model simulation. Experiments characterize dynamic behavior of a system through empirical modal analysis using impact and shaker testing. The layout of the test setup is crucial for a low-mass, nonlinear system. Physical arrangement, orientation of the system, and instrumentation affect the results that are discussed in this paper. These results can be used to validate a numerical simulation of the same system. With a validated model, important physical input parameters and modeling techniques can be determined and implemented in future designs. In other words, this modeling can be used with confidence to design alternative dampers that may be difficult, costly, and time-consuming to characterize experimentally.

Cook, Jason↗

Rethinking Programming Paradigms in the QC-HPC Context

Programming for today’s quantum computers is making significant strides toward modern workflows compatible with high performance computing (HPC), but fundamental challenges still remain in the integration of these vastly different technologies. Quantum computing (QC) programming languages share some common ground, as well as their emerging runtimes and algorithmic modalities. In this short paper, we explore avenues of refinement for the quantum processing unit (QPU) in the context of many-tasks management, asynchronous or otherwise, in order to understand the value it can play in linking QC with HPC. Through examples, we illustrate how its potential for scientific discovery might be realized.

Wong, Elaine↗

Performance Assessment of Several Low-Cost Consumer-Grade Analog-to-Digital Conversion Devices

The Oak Ridge National Laboratory (ORNL) has pioneered an approach where low-cost consumer-grade electronics can be used as the basis of a highly reliable data acquisition architecture. One twenty-channel system based on this approach has been operating almost 4 years at ORNL. The architecture allows a mix-and-match level of configurability so the designer can select devices that best match the desired performance trade-offs. The most important device to be selected is the analog-to-digital converter. This paper explores the performance of several candidate audio recording devices that can be used as high-speed analog-to-digital converters for such measurement systems. Various performance metrics are explored including frequency response, noise floor, and synchronous sampling. Sample rates as high as 192 KHz are supported with 16 and 24-bit resolution. While most of the devices are dual-channel, there are multi-channel devices now available that will allow modal type of synchronous sampling. One such device was tested and is discussed is this paper.

Wetherington Jr, G↗

Deep Data Analytics in Structural and Functional Imaging of Nanoscale Materials

Recent advances in scanning probe microscopy and scanning transmission electron microscopy have opened unprecedented opportunities in probing the materials structural parameters and electronic properties in real space on a picometre-scale. At the same time, the ability of modern day microscopes to quickly produce large, high-resolution datasets has created a challenge for rapid physics-guided analysis of data that typically contain several hundreds to several thousand atomic or molecular units per image. Here it is demonstrated how the advanced statistical analysis and machine learning techniques can be used for extracting relevant physical and chemical information from microscope data on multiple functional materials. Specifically, the following three case studies are discussed (i) application of a combination of convolutional neural network and Markov model for analyzing positional and orientational order in molecular self-assembly; (ii) a combination of sliding window fast Fourier transform, Pearson correlation matrix and canonical correlation analysis methods to study the relationships between lattice distortions and electron scattering patterns in graphene; (iii) application of a non-negative matrix factorization with physics-based constraints and Moran’s analysis of spatial associations to extracting electronic responses linked to different types of structural domains from multi-modal imaging datasets on iron-based superconductors. The approaches demonstrated here are universal in nature and can be applied to a variety of microscopic measurements on different materials.

Ziatdinov, Maxim↗

Domain Optimization for an Acoustic Waveguide Scattering Problem

We consider a domain optimization problem of an unbounded domain, which models scattering of a time-harmonic acoustic wave at the junction of two closed waveguides. Solutions of our problem fulfill the Helmholtz equation with a real wavenumber, a modal radiation condition and homogeneous Dirichlet boundary conditions. We derive an a-priori bound for the solution on a certain class of domains (which is compact in the Hausdorff metric topology) and show that within this class the solution depends H{sup 1}-continuously on the domain. Furthermore, we show some numerical examples to illustrate our results, which were calculated using the domain (or shape) derivative of our problem.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Asymptotic Representation for the Eigenvalues of a Non-selfadjoint Operator Governing the Dynamics of an Energy Harvesting Model

We consider a well known model of a piezoelectric energy harvester. The harvester is designed as a beam with a piezoceramic layer attached to its top face (unimorph configuration). A pair of thin perfectly conductive electrodes is covering the top and the bottom faces of the piezoceramic layer. These electrodes are connected to a resistive load. The model is governed by a system consisting of two equations. The first of them is the equation of the Euler–Bernoulli model for the transverse vibrations of the beam and the second one represents the Kirchhoff’s law for the electric circuit. Both equations are coupled due to the direct and converse piezoelectric effects. The boundary conditions for the beam equations are of clamped-free type. We represent the system as a single operator evolution equation in a Hilbert space. The dynamics generator of this system is a non-selfadjoint operator with compact resolvent. Our main result is an explicit asymptotic formula for the eigenvalues of this generator, i.e., we perform the modal analysis for electrically loaded (not short-circuit) system. We show that the spectrum splits into an infinite sequence of stable eigenvalues that approaches a vertical line in the left half plane and possibly of a finite number of unstable eigenvalues. This paper is the first in a series of three works. In the second one we will prove that the generalized eigenvectors of the dynamics generator form a Riesz basis (and, moreover, a Bari basis) in the energy space. In the third paper we will apply the results of the first two to control problems for this model.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Ureteral pseudodiverticulosis and urothelial cell carcinoma: rethinking the association

Purpose: To compare frequency of new and recurrent urothelial cell carcinoma (UCC) among patients with and without pseudodiverticulosis on imaging. Methods: This retrospective case–control study compared all 113 sequential patients with ureteral pseudodiverticulosis on radiographic urography between 1/1/2002 and 12/31/2012. Six patients were lost to follow-up. 107 patients without pseudodiverticulosis were matched by imaging modality, clinical indication, and tumor grade. Known UCC and primary outcome of new or recurrent UCC were determined through pathology on cystoscopy or clinical follow-up. Results: Nearly half of patients with pseudodiverticulosis had known UCC at the time of imaging (49/107, 46%). Mean cystoscopy follow-up was 7.0 and 4.6 years for pseudodiverticulosis cases with and without known UCC, respectively, and 7.5 and 7.3 years for controls, respectively. Mean clinic follow-up was 7.5 and 6.0 years for pseudodiverticulosis cases with and without known UCC, respectively, and 6.4 and 7.6 years for controls, respectively. Among patients with known UCC at the time of imaging, similar rates of recurrent UCC were demonstrated on follow-up among patients with pseudodiverticulosis (6/49, 12%) and without (7/49, 14%). Among patients with no known history of UCC at the time of imaging, no patients with pseudodiverticulosis developed UCC on follow-up and 5% (3/58) of patients without pseudodiverticulosis developed UCC. Conclusion: Although half of patients with ureteral pseudodiverticulosis have a known diagnosis of UCC, the presence of pseudodiverticulosis did not signify an increased likelihood of developing new or recurrent UCC over the follow-up period.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Role of dual energy CT to improve diagnosis of non-traumatic abdominal vascular emergencies

Computed tomography angiography (CTA) is the modality of choice to evaluate abdominal vascular emergencies (AVE). CTA protocols are often complex and require acquisition of multiple phases to enable a variety of diagnosis such as acute bleeding, pseudoaneurysms, bowel ischemia, and dissection. With single energy CT (SECT), differentiating between calcium, coagulated blood, and contrast agents can be challenging based on their attenuation, especially when in small quantity or present as a mixture. With dual-energy CT (DECT), virtual monoenergetic (VM) and material decomposition (MD) image reconstructions enable more robust tissue characterization, improve contrast-enhancement, and reduce beam hardening artifacts. This article will demonstrate how radiologists can utilize DECT for various clinical scenarios in assessment of non-traumatic AVE.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Double contrast-enhanced ultrasound improves the detection and localization of occult lesions in the pancreatic tail: a initial experience report

Purpose: The aim of this study is to review our initial experience of Double contrast-enhanced ultrasonography (DCEUS) in the preoperative detection of pancreatic tail occult tumors. Methods: Thirty-five patients were recruited to undergo DCEUS of the pancreas suspected by occult lesions of pancreatic with MRI or clinical evidence. The radiologists assessed the images (conventional US, DCEUS, and MRI) for enhancement phases, tumor presence, location, enhancement characteristics, and tumor conspicuity. The differences in the onset times of the phases between DCEUS and MRI were noted. Tumor conspicuity was graded on a four-point scale for conspicuity comparison among three imaging modalities. Results: Pancreatic tail tumors were missed on conventional transabdominal US in 11 of 35 patients. DCEUS revealed 12 lesions of 35 patients. Pancreatic tail tumors were identified on MRI in 10 of 35 patients. The sensitivity and specificity of DCEUS for depicting occult lesions of ≤ 2.2 cm were 92% and 95%, respectively. In contrast, the sensitivity and specificity of conventional US were 67% and 66%, respectively. The sensitivity and specificity of MRI were 91% and 88%, respectively. The conspicuity ratings of the three phases did not significantly differ between the DCEUS and MRI groups (P > 0.05). The DCEUS phases started much earlier than the corresponding MRI phases. Conclusion: DCEUS is a promising technique in the detection of occult pancreatic tail tumors and is possibly superior to dynamic enhanced MRI in the case of some peripheral lesions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Pathological variants of hepatocellular carcinoma on MRI: emphasis on histopathologic correlation

Hepatocellular carcinoma (HCC) is a unique tumor because it is one of the few cancers which can be treated based on imaging alone. Magnetic resonance imaging (MRI) carries higher sensitivity and specificity for the diagnosis of HCC than either computed tomography (CT) or ultrasound. MRI is imaging modality of choice for the evaluation of complex liver lesions and HCC because of its inherent ability to depict cellularity, fat, and hepatocyte composition with high soft tissue contrast. The imaging features of progressed HCC are well described. However, many HCC tumors do not demonstrate classical imaging features, posing a diagnostic dilemma to radiologists. Some of these can be attributed to variations in tumor biology and histology, which result in radiological features that differ from the typical progressed HCC. This pictorial review seeks to demonstrate the appearance of different variants of HCC on MRI imaging, in relation to their histopathologic features.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

CT imaging of inflatable penile prosthesis complications: a pictorial essay

Purpose: Inflatable penile prostheses (IPPs) are widely used in the United States, for patients with erectile dysfunction refractory to other treatments. Complications subsequent to IPP insertion include infection, hematoma, fluid leak, component (cylinder/pump/reservoir) complications, and retained previous IPP components. Radiologists are often called upon to identify and characterize these complications utilizing CT prior to intervention. Our paper aims to provide a guide to familiarize radiologists with normal IPP component imaging and review the CT findings of commonly encountered complications. Methods: In this study, we retrospectively reviewed CT reports with descriptions of IPPs from 108 patients. We collected CT images of normal IPP components as well as reevaluated the CT findings of 33 patients with an IPP complication and correlated with immediately subsequent operative report. Results: The CT appearance of appropriately positioned normal IPP components in asymptomatic patients and each complication were described and compared to previous literature. Conclusions: CT is a very useful modality to assess an IPP-related complication. It is inexpensive, fast, and immediately available in emergent situations, e.g., infection, hematoma, and component erosion. Additionally, CT is very sensitive and makes it easier to diagnose a system leak. It can identify most cylinder complications and pump malposition and can be extremely helpful to the surgeon in preoperative planning if revision is needed. After this review, the radiologist should be able to identify normal IPP components and their complications.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Imaging in the pre-operative staging of ovarian cancer

The main prognostic factor in ovarian cancer is the stage of disease at diagnosis. The staging system in use (FIGO classification, updated in 2014) is based on the surgical-pathological findings. Although surgical staging is the gold standard in ovarian cancer, the initial patient management depends on the imaging-based pre-surgical staging assessment, in order to identify unresectable or difficult to resect disease. Radiologists need to be aware of the strengths of the available imaging modalities, as well as the imaging pitfalls. Clear understanding of pattern of disease spread and review areas are critical for accurate staging and treatment planning. The current standard of care for pre-surgical staging is CT of the thorax, abdomen, and pelvis. This allows a rapid evaluation of disease extent and is fairly accurate in identifying bulky disease but has definite limitations in assessing the extent of small volume disease and in the confirmation of certain sites of disease beyond the abdomen. Functional MRI has been reported to be superior in detecting small peritoneal deposits. PET/CT may be used as a problem-solving tool in some patients where determination remains unclear, particularly in confirmation of advanced stage beyond the abdomen.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Judging the J pouch: a pictorial review

Restorative total proctocolectomy with ileal pouch-anal anastomosis is the surgery of choice for patients with medically refractory ulcerative colitis, ulcerative colitis with high-grade dysplasia or multi-focal low-grade dysplasia, and for patients with familial adenomatous polyposis. The natural history of the surgery is favorable, and patients generally experience improved quality of life and acceptable long-term functional outcome. However, some patients experience significant long-term morbidity from early and/or late pouch-related complications. When complications arise, radiologists must understand the advantages and disadvantages of the various imaging modalities that can be used to assess the pouch. Radiologist familiarity with the surgical technique, pouch anatomy, and imaging appearance of the various potential early and late complications will help facilitate appropriate clinical and surgical decision-making. This review provides an anatomic-based imaging review of the pouch and pouch-related complications, including numerous illustrative fluoroscopic and cross-sectional imaging examples.

62 RADIOLOGY AND NUCLEAR MEDICINE↗