Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Microgrid”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,405 records · Page 78

A Deep Learning Approach for In-Network Synchrophasor Missing Data Recovery Using Programmable Network Switches

Phasor measurement unit (PMU) networks deliver accurate and timely measurements, which is essential for managing today’s electric power systems. To ensure data quality and enhance the cyber-resilience of PMU networks against malicious attacks and data errors, this study presents an online PMU missing data recovery scheme by leveraging P4 programmable switches. The data plane incorporates a customized PMU protocol parser that abstracts the necessary payload data for recovery. Recovery processes are executed in the control plane using a pre-trained machine learning model. Both traditional and advanced ML models, such as transformer and TimeGPT, are explicitly employed for data prediction. This approach ensures rapid and precise data recovery. Performance evaluations focus on recovery speed and accuracy, using a real dataset from a campus microgrid. With 20% missing PMU data, the mean absolute percentage error for voltage magnitude is 0.0384%, and the phase angle error discrepancy is approximately 0.4064%.

Phasor Measurement Unit, Machine Learning, Program↗

Uncovering Droop Control Laws Embedded Within the Nonlinear Dynamics of Van der Pol Oscillators

This paper examines the dynamics of power-electronic inverters in islanded microgrids that are controlled to emulate the dynamics of Van der Pol oscillators. The general strategy of controlling inverters to emulate the behavior of nonlinear oscillators presents a compelling time-domain alternative to ubiquitous droop control methods which presume the existence of a quasistationary sinusoidal steady state and operate on phasor quantities. We present two main results in this paper. First, by leveraging the method of periodic averaging, we demonstrate that droop laws are intrinsically embedded within a slower time scale in the nonlinear dynamics of Van der Pol oscillators. Second, we establish the global convergence of amplitude and phase dynamics in a resistive network interconnecting inverters controlled as Van der Pol oscillators. Furthermore, under a set of nonrestrictive decoupling approximations, we derive sufficient conditions for local exponential stability of desirable equilibria of the linearized amplitude and phase dynamics.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Hierarchical Power Flow Control in Smart Grids: Enhancing Rotor Angle and Frequency Stability with Demand-Side Flexibility

Large-scale integration of renewables in power systems gives rise to new challenges for keeping synchronization and frequency stability in volatile and uncertain power flow states. To ensure the safety of operation, the system must maintain adequate disturbance rejection capability at the time scales of both rotor angle and system frequency dynamics. This calls for flexibility to be exploited on both the generation and demand sides, compensating volatility and ensuring stability at the two separate time scales. This article proposes a hierarchical power flow control architecture that involves both transmission and distribution networks as well as individual buildings to enhance both small-signal rotor angle stability and frequency stability of the transmission network. The proposed architecture consists of a transmission-level optimizer enhancing system damping ratios, a distribution-level controller following transmission commands and providing frequency support, and a building-level scheduler accounting for quality of service and following the distribution-level targets. Furthermore, we validate the feasibility and performance of the whole control architecture through real-time hardware-in-loop tests involving real-world transmission and distribution network models along with real devices at the Stone Edge Farm Microgrid.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Losing Control of Your Linear Network? Try Resilience Theory

Resilience of cyber-physical networks to unexpected failures is a critical need widely recognized across domains. For instance, power grids, telecommunication networks, transportation infrastructures, and water treatment systems have all been subject to disruptive malfunctions and catastrophic cyberattacks. Following such adverse events, we investigate scenarios where a node of a linear network suffers a loss of control authority over some of its actuators. These actuators are not following the controller's commands and are instead producing undesirable outputs. The repercussions of such a loss of control can propagate and destabilize the whole network despite the malfunction occurring at a single node. To assess system vulnerability, we establish resilience conditions for networks with a subsystem enduring a loss of control authority over some of its actuators. Furthermore, we quantify the destabilizing impact on the overall network when such a malfunction perturbs a nonresilient subsystem. We illustrate our resilience conditions on two academic examples, on an islanded microgrid and on the linearized IEEE 39-bus system.

97 MATHEMATICS AND COMPUTING↗

Network Constraints Consideration for Grid-Edge Energy Management System

Increased deployment of distributed energy resources (DER) in distribution system is bringing need for enhanced grid intelligence, control, and flexibility. This is significant at the edge of the grid where DERs, loads or microgrids are located. Integrated DERs in a distribution system need to follow grid codes to avoid violations that results in DER disconnection. To comply with grid code requirements (e.g. IEEE 1547-2018) at the grid edge level, network constrained grid edge energy management system (GEEMS) is proposed in this paper. The objective of GEEMS is to provide economic solution for active and reactive power dispatch set-points at each interval and ensure voltage regulation to support secure interconnection of the grid edge segment to the distribution system. To evaluate the proposed GEEMS framework, four DERs are included into IEEE 13 bus system. GEEMS outperforms the existing economic dispatch-based energy management system by reducing the voltage violation.

Electric vehicle depot charging station↗

An Enhanced Model Predictive Control Using Virtual Space Vectors for Grid-Connected Three-Level Neutral-Point Clamped Inverters

Reliability of power systems can be improved by the use of voltage source inverters (VSIs) with fast dynamic control, which can handle uncertainties induced by renewable energy resources and nonlinear loads. To ensure fast-dynamic response and simplified controller design, various model predictive control (MPC) methods are investigated in this paper. In the conventional MPC design for three-level VSIs, the cost function requires an additional term to ensure the balance of the neutral-point voltage (NP-V), which however can considerably impact the main goal of the MPC. To address this issue, an enhanced MPC using virtual space vectors is proposed, which allows the use of a significantly reduced weighting factor for the term in the cost function for NP-V balancing, while retaining fast-dynamic response. Additionally, the proposed MPC leads to reduced harmonic distortion in the VSI output voltage and current. Both simulation and controller hardware-in-the-loop studies are performed to demonstrate the effectiveness of the proposed enhanced MPC in an operating microgrid under both steady-state and fast-transient conditions.

30 DIRECT ENERGY CONVERSION↗

Allocation Mechanisms in Rationed Markets

Economic theory has come to play an important role in power system operations through the design of wholesale markets that are central to their operation. Furthermore, transactive energy places economic theory as a cornerstone in its operational concept as it seeks to integrate the technical needs of the power system with the preferences of its participants. Traditionally the mechanism employed is the continuous double-auction but de-pending on the circumstances the power system find itself in, this mechanism may or may not be the most appropriate, i.e. a one-size fits all market institution cannot be recommended without regard for the features of the underlying trading environment. This paper seeks to explain the economic rationale that guides the choice of a market institution and takes recourse to a theoretical demonstration in the context of a rationed power system scenario where demand exceeds generation (due to any number of events such as outages, microgrid operation, etc) and electrical energy must be rationed to better understand which types of mechanisms are most appropriate.

transactive energy, power system economics, econom↗

Transactive Energy Rationing in Islanded Electric Power Systems

Extreme weather events, many of which are climate change related, are occurring with increasing frequency and intensity and causing catastrophic outages. One of the major modern-day concerns of utilities is dealing with such extreme outages and consequently, its repercussions on the lives of people in society and social aspects. Traditionally, operators have been using rolling blackouts as a contingency plan to serve critical loads during such events when electricity supply is scarce. However, such blackouts practices are executed on a last-minute mandatory basis, depriving customers having low-capacity high priority loads (i.e. refrigeration, water, telecommunication, etc) that should also be serviced if at all possible. Historically, policymakers have often adopted quota-based regulatory actions or rationing for other commodities (such as gasoline, butter, sugar) to handle scarcity situations. Motivated from such quota based systems, our contribution presented in this work is an alternative transactive rationing mechanism that would provide some minimum level of service to all of the customers and serve the critical loads using market-based control during such scarcity-based contingencies. This is in contrast to the state-of-art TE mechanisms that allocate resources to customers solely based on their willingness-to-pay. The effectiveness of the proposed mechanism is demonstrated through simulation-based evaluation on two real-life use cases having feeder-level and microgrid-level configurations respectively. The simulation results clearly demonstrate the capability of the rationing scheme to serve customers’ high-priority loads through prolonged outages even during extreme scarcity scenarios.

42 ENGINEERING↗

A Data-Driven Passive Islanding Detection Scheme

This paper proposes a simple yet effective statistical parameters based passive islanding scheme. The proposed scheme relies only the voltage data, measured at the point of common coupling (PCC), and is comprised of three stages. The Stage-1 quickly computes what is termed as mean based coarse islanding detection (MID), Stage-2 computes the decaying DC detector (DDCD), and 3) finally, MID is used in conjunction with DDCD as per the statistical digital relay logic (SRDL) is devised in Stage-3 to distinguish between islanding events from non islanding events. Various tests are investigated on the Banshee's industrial Microgrid (MG), modelled in the Real Time Digital Simulator (RTDS), on the basis of the IEEE-1547, UL 1741 standards. The validation of the proposed islanding detection methodology (PIDM) in RTDS platform ensures the viability of the proposed scheme in practical systems. The test results reveal that the PIDM can detect islanding within 2 cycles, and results in a very small non detection zone (NDZ). Moreover, the scheme can very well be used for single-phase MG too as it relies only on the single phase voltage information.

anti-islanding protection↗

D–Q Impedance Based Stability Analysis and Parameter Design of Three-Phase Inverter-Based AC Power Systems

Small-signal stability is an important concern in three-phase inverter-based ac power systems. The impedance-based approach based on the generalized Nyquist stability criterion (GNC) can analyze the stability related with the medium and high-frequency modes of the systems. However,. the GNC involves the right-half-plane (RHP) pole calculation of return-ratio transfer function matrices, which cannot be avoided for stability analysis of complicated ac power systems. Therefore, it necessitates the detailed internal control information of the inverters, which is not normally available for commercial inverters. To address this issue, this paper introduces the component connection method (CCM) in the frequency domain for stability analysis in the synchronous d-q frame, by proposing a method of deriving the impedance matrix of the connection networks of inverter-based ac power systems. Demonstration on a two-area system and a microgrid shows that: The CCM-enabled approach can avoid the RHP pole calculation of return-ratio matrices and enables the stability analysis by using only the impedances of system components, which could be measured without the need for the internal information. A stability analysis method based on d-q impedances, the CCM, and the determinant-based GNC is also proposed to further simplify the analysis process. Inverter controller parameters can be designed as stability regions in parameter spaces, by repetitively applying the proposed stability analysis method. Simulation and experimental results verify the validity of the proposed stability analysis method and the parameter design approach.

42 ENGINEERING↗

High-Frequency Transformer Design for Modular Power Conversion From Medium-Voltage AC to 400 VDC

This paper presents a high-frequency modular medium-voltage AC (4160 VAC or 13.8 kVAC) to low-voltage DC (400 VDC) system that is scalable in order to be used for different scale microgrids. A 15 kW, 500 kHz DC/DC converter is demonstrated as the most important stage of the system overall, which can be scalable to a 225 kW 4160 VAC to 400 VDC system. Motivation of a CLLC resonant converter and its design parameters determination is carefully illustrated. The high-frequency transformer is the key element for the DC/DC converter. Then, the paper focuses on high-frequency transformer design to realize high-voltage insulation, high efficiency, and high density at the same time. Based on a split winding UU core transformer structure, transformer insulation materials and dimension parameters are determined referring to the IEEE insulation standard. The transformer magnetic loss model is reviewed based on which loss design tradeoff is carefully analyzed. Different working frequency impact on transformer design over three different core materials is also presented. Finally, a 500 kHz transformer prototype has been developed and demonstrated with the IEEE standard required insulation tests. A whole CLLC resonant converter is also present with experiments results. Here, the converter holds outstanding 98% efficiency and 2.9 kW/L power density.

42 ENGINEERING↗

Modeling of Grid-Forming and Grid-Following Inverters for Dynamic Simulation of Large-Scale Distribution Systems

Historically, distribution system planning studies mainly focused on steady state and quasi-steady state analysis, with limited attention paid to dynamic analysis. This paper develops three-phase, electromechanical models for both grid-forming and grid-following inverters, and integrates them into an open source, three-phase distribution network solver, thereby enabling dynamic simulation of large-scale, three-phase unbalanced distribution systems with high penetration of inverter-based DERs. The proposed inverter models are validated against electromagnetic simulation and field test data from the CERTS/AEP microgrid testbed, and simulated in an islanded 5252 node distribution system in the GridLAB-D simulation environment. Simulation verifies the effectiveness of the proposed inverter models for large-scale distribution system analysis. Finally, study results show that compared to traditional grid-following inverters, the high penetration of grid-forming inverters can improve the voltage and frequency stability of islanded distribution systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Statistical Behavior of Low-Amplitude Power System Point-on-Wave Measurements

The power grid is undergoing massive changes to ensure resiliency and reliability in a more decentralized world. Distributed energy resources are becoming a prominent source of generation, potentially leading to a lack of centralized generation sources. Due to these new behaviors and system topologies, it is important to install measurement devices that are 1) accurate and 2) self-aware of their measurement quality. In this paper, a residential-scale microgrid is used to generate voltage and current waveforms, captured by Verivolt and National Instruments measurement equipment. A least-squares approach is used to separate the “clean” signals from the noise. Finally, Gaussian mixture modeling is used to approximate noise distributions, and it is shown these higher-order distribution estimates are a better fit to voltage and current noise profiles than single-mode Gaussian estimates.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Distribution Locational Marginal Pricing (DLMP) for Congestion Management and Voltage Support

In this paper, a day-ahead market-clearing model for smart distribution systems is proposed. Various types of distributed energy resources (DERs), such as distributed energy storage, distributed generators, microgrids, and load aggregators, can bid into the day-ahead distribution-level electricity market. Considering system Volt/VAR control, network reconfiguration, and interactions with the wholesale market, an optimization model is built to clear the day-ahead market, through which the distribution locational marginal pricing (DLMPs) for both active power and reactive power are determined. Through derivations of the Lagrangian function and sensitivity factors, DLMPs are decomposed to five components (i.e., marginal costs for active power, reactive power, congestion, voltage support, and loss), which provide price signals to motivate DERs to contribute to congestion management and voltage support. Finally, case studies demonstrate the effectiveness of the proposed method.

congestion management↗

Mobile Emergency Generator Pre-Positioning and Real-Time Allocation for Resilient Response to Natural Disasters

Truck-mounted mobile emergency generators (MEGs) are critical flexibility resources of distribution systems (DSs) for resilient emergency response to natural disasters. However, they are currently under-utilized. For better utilization, this paper proposes dispatching MEGs as distributed generators in DSs to restore critical loads by forming multiple microgrids (MGs). As the travel time of MEGs on road networks (RNs) can greatly influence the outage duration of critical loads, a two-stage dispatch framework consisting of pre-positioning and real-time allocation is introduced, and the traffic issue is considered via the vehicle routing problem. Pre-positioning places MEGs in staging locations prior to a natural disaster, while real-time allocation sends MEGs from staging locations to restore critical loads by forming MGs in DSs after the natural disaster strikes. Specifically, with the objective of minimizing the expected outage duration of loads considering their priorities and demand sizes, pre-positioning is done via a scenario-based two-stage stochastic optimization problem, in which the first-stage pre-positioning decisions are evaluated by numbers of second-stage real-time allocation problems corresponding to considered scenarios of DS damage and RN damage/congestion. A scenario decomposition algorithm is applied to solve this problem. Illustrative cases demonstrate the effectiveness of the proposed dispatch scheme and algorithm.

Lei, Shunbo (ORCID:0000000181690821)↗

Distributed Load Restoration in Unbalanced Active Distribution Systems

We present that the resilience of modern power systems has been constantly threatened by various natural disasters and manmade attacks. Under those threats, fast and automatic restoration actions are critical for restoring impacted systems to normal operating conditions and preventing from additional disastrous consequences. Smart grid technologies, such as distributed energy resources (DERs) and microgrids, provide both opportunities and challenges for distribution system restoration. In this paper, distributed load restoration (DLR), in unbalanced active distribution networks is developed using the alternating direction method of multipliers (ADMM) algorithm. The step-by-step restoration actions are provided to schedule the output of DERs and distribution system control devices, as well as the power consumption from transmission system restoration. The nonlinearities from three-phase unbalanced power flow and distribution components modeling are relaxed into a convex quadratic programming model. Then, the problem is decomposed into subproblems for each node by applying ADMM-DLR; and solves through each agent by exchanging limited information with neighboring nodes in an iterative procedure. The developed models and algorithms are validated and demonstrated through testing of the IEEE 13-node and 123-node test feeders. Lastly, simulation results demonstrate the effectiveness of restoring unbalanced distribution system with the hybrid bottom-up and top-down restoration strategies.

14 SOLAR ENERGY↗

Coordinating Multiple Sources for Service Restoration to Enhance Resilience of Distribution Systems

When a major outage occurs on a distribution system due to extreme events, microgrids, distributed generators, storage devices, and other local resources can be used to restore critical loads and enhance resiliency. This paper proposes a decision-making method to determine the optimal restoration strategy coordinating multiple sources to serve critical loads after a major outage. The critical load restoration problem is formulated as a mixed -integer semidefinite program. The objective is maximizing the number of loads restored, weighted by their priority. The unbalanced three-phase power flow constraint and operational constraints are considered. An iterative algorithm is proposed to deal with integer variables and can attain the global optimum of the critical load restoration problem by solving a few semidefinite programs under mild conditions. The effectiveness of the proposed models and algorithm is validated by numerical simulation with the modified IEEE 13-node test feeder and the modified IEEE123-node test feeder under a large number of scenarios. The results indicate that the optimal restoration strategy can be determined efficiently in most scenarios

Wang, Ying↗

A Novel Framework for Optimizing Ramping Capability of Hybrid Energy Storage Systems

Hybrid Energy Storage System has been widely applied in aerospace, electric vehicle, and microgrid applications. The advantages are that they include complimentary technologies with both high power and energy capabilities. HESS have the potential to be useful to the bulk power systems, for example to increase the value of energy produced by variable generation resource through enabling participation in ancillary service markets. Actualizing the benefits of HESSs requires optimizing the combined ramping capability of aggregated HESS resources. To provide quality ancillary service, source of HESSs locating at multiple sites of variable generation resource must be optimally sized and cohesively controlled. Optimizing aggregated resources can be formulated as an optimization problem. Successfully solving this problem not only requires using effective solution methods but also depends on accurately and rapidly setting the necessary parameters in the problem formula. This article proposes a novel framework with double-layer structure to solve the optimization problem of aggregating ramping capability. Program developed on the upper layer focuses on solving the optimization of aggregating ramping capability among multiple HESSs and is compatible with most existing optimization algorithms. Program on lower layer of the framework targets at optimizing the local control of a single HESS based on a thorough analytics of HESS operation strategy presented in this article. Result of local optimization is also provided to upper layer program for updating the parameters in formula of optimization problem. Real time hardware-in-the-loop test is conducted to verify the performance of the optimization framework developed. The work presented is expected to provide guidance for implementing this framework in practical operation.

Luo, Yushen↗