Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Measurement error”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,405 records · Page 78

A Dynamically-Reconfigurable Burst-Mode Link Using a Nanosecond Photonic Switch

Fast optical circuit switching has great potential to solve scaling issues with traditional packet-switch based networks and improve bandwidth and power efficiency in datacenter and high-performance computing applications. One difficultly in utilizing a fast optical switch is that the optical signal must be rapidly reacquired after each switching event so as to not significantly impact the overall throughput of the system. In this work we present a system-level integration of a nanosecond-scale $2 \times 2$ silicon photonic switch with a 25-Gbps burst-mode receiver that can lock in 31 ns. A novel FPGA-based control plane was used to generate test data, control the silicon photonic switch and burst-mode receiver, and measure bit errors at 12.5 and 20 Gbps. Error-free links (BER $< 10^{-12}$ ) with system-level reconfiguration times below 60 ns (at 20 Gbps) and 90 ns (at 12.5 Gbps) including bit- and frame-synchronization are demonstrated.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Introducing Human Mandible Identification [(hu)MANid]: A Free, Web‐Based GUI to Classify Human Mandibles

Abstract Statistical programs have revolutionized the way in which forensic anthropologists conduct casework by allowing practitioners to use computationally complex analytics at the click of a button. Importantly, the products of these statistical programs are reproducible and contain measures of error or uncertainty, thereby strengthening conclusions. This paper is an introduction to (hu) MAN id, a free, web‐based application that uses linear and mixture discriminant function analyses to classify human mandibles into one of many worldwide and/or periodic reference groups. The mechanics, development, and use of the application will be discussed. Further, the program was tested against other software to compare model performances and classifications. Total correct classifications among the test cases and programs were identical. Ten mandibles were tested using both statistical procedures. Mixture discriminant analysis improved classification by an average of 9.3% and correctly identified three more mandibles than LDA . Therefore, we believe (hu) MAN id will be an asset to the anthropological community.

Berg, Gregory E.↗

Melting point of group IV and V transition metal diborides

The environmental conical nozzle levitator system enables cooling trace experiments above 4000 K. These cooling trace experiments were used to determine the melting points through observation of thermal arrest of group IV and V transition metal diborides (TiB 2 , T m = 3313 ± 33 K; ZrB 2 , T m = 3404 ± 38 K; HfB 2 , T m = 3529 ± 33 K; and TaB 2 , T m = 3284 ± 10 K; note: mean ± 2 standard error). Temperature measurements were conducted utilizing dual single-color pyrometers at wavelengths of 0.9 and 0.65 µm. This system utilizes aerodynamic levitation and dual laser heating to achieve temperatures approaching 4000 K. The samples were synthesized from commercial powders using ceramic gel-casting to produce high-density spherical components. The measurements obtained were compared to previously reported melting temperature values and were generally found to be in agreement with most of the published values.

Materials science↗

SU-E-I-84: Accuracy Comparison of Multi-Modality Image-Based Volumes of Rodent Solid Tumors Using In-Air Micro-CT Image Volume

Purpose: Tumor volume is considered as a better predictor for therapy response monitoring and tumor staging over Response Evaluation Criteria In Solid Tumors (RECIST) or World Health Organization (WHO) criteria. In this study, the accuracy of subcutaneous rodent tumor volumes using preclinical magnetic resonance imaging (MRI), micro-computed tomography (micro-CT) and ultrasound (US) equipment and with an external caliper was compared using in-air micro-CT image volume of excised tumors determined as reference tumor volume in our prior study. Methods: MR, US and micro-CT images of subcutaneous SCC4 head and neck tumor xenografts were acquired 4, 6, 9, 11 and 13 days after tumor cell inoculation. Before MR and US scans, caliper measurements were made. After tumors were excised, in-air micro-CT imaging and ex vivo caliper measurements were performed. Tumor volumes were calculated using formula V = (π/6)*a*b*c where a, b and c are the maximum diameters in three perpendicular dimensions determined by the three image modalities and caliper, and compared with reference tumor volume by linear regression analysis as well as Bland-Altman plots. A one-way Analysis of Variance (ANOVA) test was also performed to compare volumes among caliper measurements. Results: The correlation coefficients (R2) of the regression lines for tumor volumes measured by the three imaging modalities and caliper were 0.9939, 0.9669, 0.9806, 0.9274, 0.9619 and 0.9819 for MRI, US and micro-CT, caliperbeforeMRI, caliperbeforeUS and ex vivo caliper respectively. In Bland-Altman plots, the average of tumor volume difference from reference tumor volume (bias) was significant for caliper and micro- CT, but not for MRI and US. Comparison of caliper measurements showed a significant difference (p < 0.05). Conclusion: Using the in-air micro-CT image volume, tumor volume measured by MRI was the most accurate among the three imaging modalities. In vivo caliper volume measurements showed unreliability while ex vivo caliper measurements reduced errors.

60 APPLIED LIFE SCIENCES↗

MO-FG-204-01: Improved Noise Suppression for Dual-Energy CT Through Entropy Minimization

Purpose: In dual energy CT (DECT), noise amplification during signal decomposition significantly limits the utility of basis material images. Since clinically relevant objects contain a limited number of materials, we propose to suppress noise for DECT based on image entropy minimization. An adaptive weighting scheme is employed during noise suppression to improve decomposition accuracy with limited effect on spatial resolution and image texture preservation. Methods: From decomposed images, we first generate a 2D plot of scattered data points, using basis material densities as coordinates. Data points representing the same material generate a highly asymmetric cluster. We orient an axis by minimizing the entropy in a 1D histogram of these points projected onto the axis. To suppress noise, we replace pixel values of decomposed images with center-of-mass values in the direction perpendicular to the optimal axis. To limit errors due to cluster overlap, we weight each data point’s contribution based on its high and low energy CT values and location within the image. The proposed method’s performance is assessed on physical phantom studies. Electron density is used as the quality metric for decomposition accuracy. Our results are compared to those without noise suppression and with a recently developed iterative method. Results: The proposed method reduces noise standard deviations of the decomposed images by at least one order of magnitude. On the Catphan phantom, this method greatly preserves the spatial resolution and texture of the CT images and limits induced error in measured electron density to below 1.2%. In the head phantom study, the proposed method performs the best in retaining fine, intricate structures. Conclusion: The entropy minimization based algorithm with adaptive weighting substantially reduces DECT noise while preserving image spatial resolution and texture. Future investigations will include extensive investigations on material decomposition accuracy that go beyond the current electron density calculations. This work was supported in part by the National Institutes of Health (NIH) under Grant Number R21 EB012700.

60 APPLIED LIFE SCIENCES↗

Poster - 48: Clinical assessment of ExacTrac stereoscopic imaging of spine alignment for lung SBRT

Purpose: To evaluate the validity of using spine as a surrogate for tumor positioning with ExacTrac stereoscopic imaging in lung stereotactic body radiation therapy (SBRT). Methods: Using the Novalis ExacTrac x-ray system, 39 lung SBRT patients (182 treatments) were aligned before treatment with 6 degrees (6D) of freedom couch (3 translations, 3 rotations) based on spine matching on stereoscopic images. The couch was shifted to treatment isocenter and pre-treatment CBCT was performed based on a soft tissue match around tumor volume. The CBCT data were used to measure residual errors following ExacTrac alignment. The thresholds for re-aligning the patients based on CBCT were 3mm shift or 3° rotation (in any 6D). In order to evaluate the effect of tumor location on residual errors, correlations between tumor distance from spine and individual residual errors were calculated. Results: Residual errors were up to 0.5±2.4mm. Using 3mm/3° thresholds, 80/182 (44%) of the treatments required re-alignment based on CBCT soft tissue matching following ExacTrac spine alignment. Most mismatches were in sup-inf, ant-post, and roll directions which had larger standard deviations. No correlation was found between tumor distance from spine and individual residual errors. Conclusion: ExacTrac stereoscopic imaging offers a quick pre-treatment patient alignment. However, bone matching based on spine is not reliable for aligning lung SBRT patients who require soft tissue image registration from CBCT. Spine can be a poor surrogate for lung SBRT patient alignment even for proximal tumor volumes.

60 APPLIED LIFE SCIENCES↗

Precision Q0 Measurement of an SRF Cavity with a Digital RF Techniques

Direct measurement of the quality factor of SRF cavity using traditional RF techniques is essential for cavity production and development. Systematic effects of the measurement can contribute significant amounts of error to these measurements if not accounted for. This paper will present measurements taken at Fermilab using a digital RF system to characterize and correct for these systematic effects and directly measure the quality factor versus gradient curve for a single spoke resonator in the Spoke Test Cryostat at Fermilab. These measurements will be compared to traditional calorimetric measurements, and a discussion of improving/extending these techniques to other testing situations will be included.

43 PARTICLE ACCELERATORS↗

Distributed Sensor Coordination for Advanced Energy Systems

Motivation: The ability to collect key system level information is critical to the safe, efficient and reliable operation of advanced power systems. Recent advances in sensor technology have enabled some level of decision making directly at the sensor level. However, coordinating large numbers of sensors, particularly heterogeneous sensors, to achieve system level objectives such as predicting plant efficiency, reducing downtime or predicting outages requires sophisticated coordination algorithms. Indeed, a critical issue in such systems is how to ensure the interaction of a large number of heterogenous system components do not interfere with one another and lead to undesirable behavior. Objectives and Contributions: The long-term objective of this work is to provide sensor deployment, coordination and networking algorithms for large numbers of sensors to ensure the safe, reliable, and robust operation of advanced energy systems. Our two specific objectives are to: 1. Derive sensor performance metrics for heterogeneous sensor networks. 2. Demonstrate effectiveness, scalability and reconfigurability of heterogeneous sensor network in advanced power systems. The key technical contribution of this work is to push the coordination step to the design of the objective functions of the sensors, allowing networks of heterogeneous sensors to be controlled. By ensuring that the control and coordination is not specific to particular sensor hardware, this approach enables the design and operation of large heterogeneous sensor networks. In addition to the coordination coordination mechanism, this approach allows the system to be reconfigured in response to changing needs (e.g., sudden external events requiring new responses) or changing sensor network characteristics (e.g., sudden changes to plant condition). Impact: The impact of this work extends to a large class of problems relevant to the National Energy Technology Laboratory including sensor placement, heterogeneous sensor coordination, and sensor network control in advanced power systems. Each application has specific needs, but they all share the one crucial underlying problem: how to ensure that the interactions of a large number of heterogenous agents lead to coordinated system behavior. This proposal describes a new paradigm that addresses that very issue in a systematic way. Key Results and Findings: All milestones have been completed. Our results demonstrate that by properly shaping agent objective functions, we can develop large (up to 10,000 devices) heterogeneous sensor networks with key desirable properties. The first milestone shows that properly choosing agent-specific objective functions increases system performance by up to 99.9% compared to global evaluations. The second milestone shows evolutionary algorithms learn excellent sensor network coordination policies prior to network deployment, and these policies can be refined online once the network is deployed. The third milestone shows the resulting sensor networks networks are extremely robust to sensor noise, where networks with up to 25% sensor noise are capable of providing measurements with errors on the order of 10 -3 . The fourth milestone shows the resulting sensor networks are extremely robust to sensor failure, with 25% of the sensors in the system failing resulting in no significant performance losses after system reconfiguration.

42 ENGINEERING↗

Simulating Single Qubit Random

Single qubit RB is used to measure the error of gates via average gate fidelity. A single qubit RB program was made to calculate this. To filter out potential hardware issues, RB was executed through creating a simulator. Upon simulating both noisy and noise-less gates, we determined that there is a mix of both hardware and program issues.

Anguiano, Efren↗

Super Resolving Unrolled Neural Networks for Remote Sensing

In remote sensing systems, the capabilities of the system are constrained by the complex interactions between size, weight, and power (SWAP) of potential designs. In electro-optical (EO) systems, examples of these critical parameters include the system’s sensitivity and resolution. Those parameters can be increased by ever larger optical apertures and focal planes but at the cost of more SWAP. Multi-image super resolution (MISR) techniques allow resolution to be enhanced via computation rather than more sophisticated optical hardware. These algorithms combine multiple images together into a single, higher resolution image, trading temporal resolution and computation for spatial resolution. Fielded MISR techniques, such as Drizzle, can require several hundred images to create a single super resolved image, implying reduced temporal resolution, increased data acquisition load, and limiting mission applications. Iterative techniques, such as model-based image reconstruction and compressive sensing, have been shown to create super resolved images using fewer images than Drizzle. They do this by posing an optimization problem that balances accuracy between a highly accurate physical model and an image model. In the case of super resolution, the physical model is defined by the relation between low resolution input images and the desired high resolution output image. The image model encodes some assumptions about the super resolved image. These assumptions are meant to suppress reconstruction artifacts that arise due to deterministic physical model error, stochastic measurement noise, and potential undersampling. In practice, the performance of iterative methods are limited by imaging models compatible with optimization. Deep learning-based methods can effectively learn image models of arbitrary complexity, but lack the theoretical explainability and robustness of iterative techniques. Consensus equilibrium (CE) generalizes the iterative techniques beyond optimization, enabling blackbox algorithms such as traditional and neural image denoisers to be used as the image model. CE-based approaches retain much of the explainability and robustness of iterative techniques while allowing the expressiveness of machine learning image models to be used. Additionally, by unrolling iterations of CE with an embedded image denoiser, the image denoiser can be further trained and specialized to the specific application with potentially higher quality reconstructions. Under this project, we demonstrated the feasibility of training an unrolled neural network based upon CE. While we didn’t train one, we showed that the CE process is differentiable and its gradient can be tractably computed. We also explored the usage of a variants of CE akin to generative neural works. Most importantly, we applied the CE framework to a number of problems including non-blind deconvolution, upsampling, single-image super resolution, MISR, event-based sensing, and saturated deconvolution. Our MISR prototype creates high quality reconstructions with an order of magnitude fewer images than previous approaches and, critically, produces these reconstructions fast enough for practical usage.

47 OTHER INSTRUMENTATION↗

GLEAM: Galaxy Line Emission & Absorption Modeling

We present Galaxy Line Emission & Absorption Modeling (gleam), a Python tool for fitting Gaussian models to emission and absorption lines in large samples of 1D extragalactic spectra. gleam is tailored to work well in batch mode without much human interaction. With gleam, users can uniformly process a variety of spectra, including galaxies and active galactic nuclei, in a wide range of instrument setups and signal-to-noise regimes. gleam also takes advantage of multiprocessing capabilities to process spectra in parallel. With the goal of enabling reproducible workflows for its users, gleam employs a small number of input files, including a central, user-friendly configuration in which fitting constraints can be defined for groups of spectra and overrides can be specified for edge cases. For each spectrum, gleam produces a table containing measurements and error bars for the detected spectral lines and continuum and upper limits for nondetections. For visual inspection and publishing, gleam can also produce plots of the data with fitted lines overlaid. In the present paper, we describe gleam’s main features, the necessary inputs, expected outputs, and some example applications, including thorough tests on a large sample of optical/infrared multi-object spectroscopic observations and integral field spectroscopic data. gleam is developed as an open-source project hosted at https://github.com/multiwavelength/gleam and welcomes community contributions.

79 ASTRONOMY AND ASTROPHYSICS↗

Methods for Incorporating Model Uncertainty into Exoplanet Atmospheric Analysis

A key goal of exoplanet spectroscopy is to measure atmospheric properties, such as abundances of chemical species, in order to connect them to our understanding of atmospheric physics and planet formation. In this new era of high-quality JWST data, it is paramount that these measurement methods are robust. When comparing atmospheric models to observations, multiple candidate models may produce reasonable fits to the data. Typically, conclusions are reached by selecting the best-performing model according to some metric. This ignores model uncertainty in favor of specific model assumptions, potentially leading to measured atmospheric properties that are overconfident and/or incorrect. In this paper, we compare three ensemble methods for addressing model uncertainty by combining posterior distributions from multiple analyses: Bayesian model averaging, a variant of Bayesian model averaging using leave-one-out predictive densities, and stacking of predictive distributions. We demonstrate these methods by fitting the Hubble Space Telescope (HST) + Spitzer transmission spectrum of the hot Jupiter HD 209458b using models with different cloud and haze prescriptions. All of our ensemble methods lead to uncertainties on retrieved parameters that are larger but more realistic and consistent with physical and chemical expectations. Since they have not typically accounted for model uncertainty, uncertainties of retrieved parameters from HST spectra have likely been underreported. We recommend stacking as the most robust model combination method. Our methods can be used to combine results from independent retrieval codes and from different models within one code. They are also widely applicable to other exoplanet analysis processes, such as combining results from different data reductions.

79 ASTRONOMY AND ASTROPHYSICS↗

Emitter surface temperature distribution for a miniature thermionic diode

Brightness temperatures have been observed from five hohlraums equally spaced on a diameter of a 0.635 cm thermionic emitter surface. The hohlraums are 0.0381 cm in diameter and are 0.114 cm deep. The surface was mounted in a simulated diminiode geometry and was heated from the backside, according to the design, by electron bombardment. Several temperature observations were made at each hohlraum at four different levels of input power. Within experimental error no measurable temperature gradients across the emitter surface were observed at any input power level.

Lancashire, R. B.↗

Evaluate ERTS imagery for mapping and detection of changes of snowcover on land and on glaciers

The author has identified the following significant results. The standard error of measurement of snow covered areas in major drainage basins in the Cascade Range, Washington, using single measurements of ERTS-1 images, was found to range from 11% to 7% during a typical melt season, but was as high as 32% in midwinter. Many dangerous glacier situations in Alaska, Yukon, and British Columbia were observed on ERTS-1 imagery. Glacier dammed lakes in Alaska are being monitored by ERTS-1. Embayments in tidal glaciers show changes detectable by ERTS-1. Surges of Russell and Tweedsmuir Glaciers, now in progress, are clearly visible. The Tweedsmuir surge is likely to dam the large Alsek River by mid-November, producing major floods down-river next summer. An ERTS-1 image of the Pamir Mountains, Tadjik S.S.R., shows the surging Medvezhii (Bear) Glacier just after its surge of early summer which dammed the Abdukagor Valley creating a huge lake and later a flood in the populous Vanch River Valley. A map was compiled from an ERTS-1 image of the Lowell Glacier after its recent surge, compared with an earlier map compiled from pain-stakingly compiled from a mosaic of many aerial photographs, in a total elapsed time of 1.5 hours. This demonstrates the value of ERTS-1 for rapid mapping of large features.

Meier, M. F.↗