Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MONTE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,405 records · Page 78

Monte Carlo simulation for excessive Balmer line broadening generated by transport of fast H Atoms in an abnormal glow discharge

Monte Carlo code for fast hydrogen atom transport and generating of excessively Doppler broadened profiles based on the collision model is presented. Results for the initial monoenergetic atom beam and for a more realistic energy distribution of H atoms are reported. Line profiles obtained from the simulation are compared to our experimentally obtained data. Initial energy distribution for atoms is approximately calculated from the measured line profiles while the initial angle distribution was taken to be cosine. Balmer alpha intensity was found to exponentially decay in the negative glow region, which concurs with the experimental results. These agreements between the simulation and experiment support the collision model for excessive line broadening.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Characteristics of nanosecond pulse needle-to-plane discharges at high pressure: a particle-in-cell Monte Carlo collision simulation

A model of one dimensional in position and three dimensional in velocity space self-consistent particle in cell with Monte Carlo collision technique was employed to simulate the argon discharge between the needle and plane electrodes at high pressure, in which a nanosecond rectangular pulse was applied to the needle electrode. The work focused on the investigation of the spatiotemporal evolution of the discharge versus the needle tip size and working gas pressure. The simulation results showed that the discharge occurred mainly in the region near the needle tip at atmospheric pressure, and that the small radius of the needle tip led to easy discharge. Reducing the gas pressure gave rise to a transition from a corona discharge to a glowlike discharge along the needle-to-plane direction. The microscopic mechanism for the transition can arguably be attributed to the peak of high-energy electrons occurring before the breakdown; the magnitude of the number of these electrons determined whether the breakdown can take place.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Dose profile measurement using an imaging plate: Evaluation of filters using Monte Carlo simulation of 4 MV x-rays

Computed radiography (CR) is gradually replacing film. The application of CR for two-dimensional profiles and off-axis ratio (OAR) measurement using an imaging plate (IP) in a CR system is currently under discussion. However, a well known problem for IPs in dosimetry is that they use high atomic number (Z) materials, such as Ba, which have an energy dependency in a photon interaction. Although there are some reports that it is possible to compensate for the energy dependency with metal filters, the appropriate thicknesses of these filters and where they should be located have not been investigated. The purpose of this study is to find the most suitable filter for use with an IP as a dosimetric tool. Monte Carlo simulation (Geant4 8.1) was used to determine the filter to minimize the measurement error in OAR measurements of 4 MV x-rays. In this simulation, the material and thickness of the filter and distance between the IP and the filter were varied to determine most suitable filter conditions that gave the best fit to the MC calculated OAR in water. With regard to changing the filter material, we found that using higher Z and higher density material increased the effectiveness of the filter. Also, increasing the distance between the filter and the IP reduced the effectiveness, whereas increasing the thickness of the filter increased the effectiveness. The result of this study showed that the most appropriate filter conditions consistent with the calculated OAR in water were the ones with the IP sandwiched between two 2 mm thick lead filters at a distance of 5 mm from the IP or the IP sandwiched directly between two 1 mm lead filters. Using these filters, we measured the OAR at 10 cm depth with 100 cm source-to-surface distance and surface 10x10 cm{sup 2} field size. The results of this measurement represented that it is possible to achieve measurements with less than within 2.0% and 2.0% in the field and with less than 1.1% and 0.6% out of the field by using 2 and 1 mm lead filters, respectively.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Monte-Carlo Quantum Chemistry of Biogene Amines. Laser and Neutron Capture Effects

Monte-Carlo quantum calculation of the cluster consisting of the serotonine ST (histamine HM) molecules and 100 molecules of water is carried out. It is found that the zwitterion appears as expected to be strongly favoured with respect to neutral molecule. The perspective possibilities of laser and neutron capture action on different biomolecules are indicated.

74 ATOMIC AND MOLECULAR PHYSICS↗

Particle-in-cell with Monte Carlo collision modeling of the electron and negative hydrogen ion transport across a localized transverse magnetic field

The control of the electron temperature and charged particle transport in negative hydrogen ion sources has a crucial role for the performance of the system. It is usually achieved by the use of a magnetic filter--localized transverse magnetic field, which reduces the electron temperature and enhances the negative ion yield. There are several works in literature on modeling of the magnetic filter effects based on fluid and kinetic modeling, which, however, suggest rather different mechanisms responsible for the electron cooling and particle transport through the filter. Here a kinetic modeling of the problem based on the particle-in-cell with Monte Carlo collisions method is presented. The charged particle transport across a magnetic filter is studied in hydrogen plasmas with and without including volume production of negative ions, in a one-dimensional Cartesian geometry. The simulation shows a classical (collisional) electron diffusion across the magnetic filter with reduction in the electron temperature but no selective effect in electron energy is observed (Coulomb collisions are not considered). When a bias voltage is applied, the plasma is split into an upstream electropositive and a downstream electronegative regions. Different configurations with respect to bias voltage and magnetic field strength are examined and discussed. Although the bias voltage allows negative ion extraction, the results show that volume production of negative ions in the downstream region is not really enhanced by the magnetic filter.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Monte Carlo Simulation of the Irradiation of Alanine Coated Film Dosimeters with Accelerated Electrons

The Monte Carlo code PENELOPE was used to simulate the irradiation of alanine coated film dosimeters with electron beams of energies from 1 to 5 MeV being produced by a high-current industrial electron accelerator. This code includes a geometry package that defines complex quadratic geometries, such as those of the irradiation of products in an irradiation processing facility. In the present case the energy deposited on a water film at the surface of a wood parallelepiped was calculated using the program PENMAIN, which is a generic main program included in the PENELOPE distribution package. The results from the simulation were then compared with measurements performed by irradiating alanine film dosimeters with electrons using a 150 kW Dynamitron electron accelerator. The alanine films were placed on top of a set of wooden planks using the same geometrical arrangement as the one used for the simulation. The way the results from the simulation can be correlated with the actual measurements, taking into account the irradiation parameters, is described. An estimation of the percentage difference between measurements and calculations is also presented.

61 RADIATION PROTECTION AND DOSIMETRY↗

High order Chin actions in path integral Monte Carlo

High order actions proposed by Chin have been used for the first time in path integral Monte Carlo simulations. Contrary to the Takahashi-Imada action, which is accurate to the fourth order only for the trace, the Chin action is fully fourth order, with the additional advantage that the leading fourth-order error coefficients are finely tunable. By optimizing two free parameters entering in the new action, we show that the time step error dependence achieved is best fitted with a sixth order law. The computational effort per bead is increased but the total number of beads is greatly reduced and the efficiency improvement with respect to the primitive approximation is approximately a factor of 10. The Chin action is tested in a one-dimensional harmonic oscillator, a H{sub 2} drop, and bulk liquid {sup 4}He. In all cases a sixth-order law is obtained with values of the number of beads that compare well with the pair action approximation in the stringent test of superfluid {sup 4}He.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Monte Carlo Simulation of Heavy Nuclei Photofission at Intermediate Energies

A detailed description of photofission process at intermediate energies (200 to 1000 MeV) is presented. The study of the reaction is performed by a Monte Carlo method which allows the investigation of properties of residual nuclei and fissioning nuclei. The information obtained indicate that multifragmentation is negligible at the photon energies studied here, and that the symmetrical fission is dominant. Energy and mass distributions of residual and fissioning nuclei were calculated.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Simulation of the DIII-D Beam Ion Heating Experiment Using A Monte-Carlo Particle Code Combined With a Full Wave Code

To fully account for finite drift orbit effect of fast ions on wave-particle interaction in ion-cyclotron radio frequency (ICRF) heating experiments in tokamaks, the 5-D finite orbit Monte-Carlo plasma distribution solver ORBIT-RF is coupled with the 2-D full wave code AORSA in a self-consistent way. Comparison results of ORBIT-RF/AORSA simulation against fast-ion D{sub {alpha}}(FIDA) measurement of fast-ion distribution as well as CQL3D/ray-tracing simulation with zero-orbit approximation in the DIII-D ICRF wave beam-ion acceleration experiment are presented. Preliminary ORBIT-RF/AORSA results suggest that finite orbit width effects may explain the outward radial shift of the spatial profile measured by FIDA.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Simulation of charge breeding of rubidium using Monte Carlo charge breeding code and generalized ECRIS model

A Monte Carlo charge breeding code (MCBC) is being developed by FAR-TECH, Inc. to model the capture and charge breeding of 1+ ion beam in an electron cyclotron resonance ion source (ECRIS) device. The ECRIS plasma is simulated using the generalized ECRIS model which has two choices of boundary settings, free boundary condition and Bohm condition. The charge state distribution of the extracted beam ions is calculated by solving the steady state ion continuity equations where the profiles of the captured ions are used as source terms. MCBC simulations of the charge breeding of Rb+ showed good agreement with recent charge breeding experiments at Argonne National Laboratory (ANL). MCBC correctly predicted the peak of highly charged ion state outputs under free boundary condition and similar charge state distribution width but a lower peak charge state under the Bohm condition. The comparisons between the simulation results and ANL experimental measurements are presented and discussed.

43 PARTICLE ACCELERATORS↗

Computation of Ion Charge State Distributions After Inner-Shell Ionization In Ne, Ar And Kr Atoms Using Monte Carlo Simulation

Atomic reorganization starts by filling the initially inner-shell vacancy by a radiative transition (x-ray) or by a non-radiative transition (Auger and Coster-Kronig processes). New vacancies created during this atomic reorganization may in turn be filled by further radiative and non-radiative transitions until all vacancies reach the outermost occupied shells. The production of inner-shell vacancy in an atom and the de-excitation decays through radiative and non-radiative transitions may result in a change of the atomic potential; this change leads to the emission of an additional electron in the continuum (electron shake-off processes). In the present work, the ion charge state distributions (CSD) and mean atomic charge ions produced from inner-shell vacancy de-excitation decay are calculated for neutral Ne, Ar and Kr atoms. The calculations are carried out using Monte Carlo (MC) technique to simulate the cascade development after primary vacancy production. The radiative and non-radiative transitions for each vacancy are calculated in the simulation. In addition, the change of transition energies and transition rates due to multi vacancies produced in the atomic configurations through the cascade development are considered in the present work. It is found that considering the electron shake--off process and closing of non-allowed non-radiative channels improves the results of both charge state distributions (CSD) and average charge state. To check the validity of the present calculations, the results obtained are compared with available theoretical and experimental data. The present results are found to agree well with the available theoretical and experimental values.

36 MATERIALS SCIENCE↗

A Monte Carlo Simulation of PET of a Real Patient with GATE

The objective of this work is to perform a Monte Carlo simulation with GATE software tool of a realistic numerical phantom of a real patient. Results from the simulation, in terms of simulated decays, recorded coincidences and simulation time, are presented. Output data are reconstructed using the Software for Tomographic Image Reconstruction (STIR) package. Two different STIR image reconstruction algorithms are used to perform the reconstruction-Filtered Back Projection/3DRP and Ordered Subset Maximum A Posteriori One-Step Late algorithms. Reconstructed images are also presented.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Monte-Carlo Analysis of the Accuracy of a Novel Thomson Scattering Lidar Approach for Determination of the Electron Temperature in Fusion Plasmas

The accuracy of a novel Thomson scattering lidar approach for determination of the electron temperature in fusion plasmas is investigated by statistical Monte-Carlo modeling of the measurement process. The approach is based on the unambiguous temperature dependence of the ratio of the signal powers of two wide Thomson scattering spectral regions. It is shown that the accuracy of the novel approach is comparable with those of the center-of-mass wavelength approach we have developed recently and the commonly used fitting approach. Thus, such an approach would be advantageous by the possibility of using essentially simpler hardware consisting of only two receiving spectral channels.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

MUSiC - An Automated Scan for Deviations between Data and Monte Carlo Simulation

A model independent analysis approach is presented, systematically scanning the data for deviations from the standard model Monte Carlo expectation. Such an analysis can contribute to the understanding of the CMS detector and the tuning of event generators. The approach is sensitive to a variety of models of new physics, including those not yet thought of.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Effect of monomer sequences on conformations of copolymers grafted on spherical nanoparticles: A Monte Carlo simulation study

Functionalizing nanoparticles with organic ligands, such as oligomers, polymers, DNA, and proteins, is an attractive way to manipulate the interfacial interactions between the nanoparticles and the medium the particles are placed in, and thus control the nanoparticle assembly. In this paper we have conducted a Monte Carlo simulation study on copolymer grafted spherical nanoparticles to show the tremendous potential of using monomer sequence on the copolymers to tune the grafted chain conformation, and thus the effective interactions between copolymer grafted nanoparticles. We have studied AB copolymers with alternating, multiblock, or diblock sequences, where either A monomers or B monomers have monomer-monomer attractive interactions. Our focus has been to show the nontrivial effect of monomer sequence on the conformations of the grafted copolymers at various particle diameters, grafting densities, copolymer chain lengths, and monomer-monomer interactions in an implicit small molecule solvent. We observe that the monomer sequence, particle diameter, and grafting density dictate whether (a) the grafted chains aggregate to bring attractive monomers from multiple grafted chains together (interchain and intrachain monomer aggregation) if the enthalpy gained by doing so offsets the entropic loss caused by stretching of chains, or (b) each grafted chain folds onto itself to bring its attractive monomers together (only intrachain monomer aggregation) if the entropic loss from interchain aggregation cannot be overcome by the enthalpic gain. For six copolymers of chain length N=24 grafted on a spherical particle of diameter D=4, interchain and intrachain monomer aggregation occurs, and the radius of gyration varies nonmonotonically with increasing blockiness of the monomer sequence. At larger particle diameters the grafted chains transition to purely intrachain monomer aggregation. The radius of gyration varies monotonically with monomer sequence for intrachain monomer aggregation because as the sequence becomes blockier (like monomers are grouped together), the copolymer chain has to fold less compactly to maximize the enthalpically favorable contacts while maintaining high conformational entropy. The radius of gyration of alternating and diblock copolymers scales with chain length N through a power law <R{sub g}{sup 2}>{sup 1/2}={alpha}N{sup {nu}} with the prefactor {alpha} and scaling exponent {nu}, varying with monomer sequence and monomer-monomer attraction strength.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Quantitative Elemental Microanalysis Of Individual Particles With Use Of X-Ray Fluorescence Method And Monte Carlo Simulation

Recently a considerable interest has been triggered in the investigation of the composition of individual particles by X-ray fluorescence microanalysis. The sources of these micro-samples are mostly diversified. These samples come from space dust, air and ash, soil as well as environment and take the shape of a sphere or an oval. In analysis this kind of samples the geometrical effects caused by different sizes and shapes influence on accuracy of results. This fact arises from the matrix effect. For these samples it is not possible to find analytically a solution of equation taking into account an absorption of X-rays. Hence, a way out is to approximate the real sample shape with the other one or to use Monte Carlo (MC) simulation method. In current work authors utilized the iterative MC simulation to assess an elemental percentage of individual particles. The set of glass micro-spheres, made of NIST K3089 material of known chemical composition, with diameters in the range between 25 and 45 {mu}m was investigated. The microspheres were scanned with X-ray tube primary radiation. Results of MC simulation were compared with these of some analytical approaches based on particle shape approximation. An investigation showed that the low-Z elements (Si, Ca, Ti) were the most sensitive on changes of particle shape and sizes. For high-Z elements (Fe--Pb) concentrations were nearly equal regardless of method used. However, for the all elements considered, results of MC simulation were more accurate then these of analytical relationships taken into comparison.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Monte Carlo Simulation of Electron Transport in 4H- and 6H-SiC

The Monte Carlo (MC) simulation of electron transport properties at high electric field region in 4H- and 6H-SiC are presented. This MC model includes two non-parabolic conduction bands. Based on the material parameters, the electron scattering rates included polar optical phonon scattering, optical phonon scattering and acoustic phonon scattering are evaluated. The electron drift velocity, energy and free flight time are simulated as a function of applied electric field at an impurity concentration of 1x10{sup 18} cm{sup 3} in room temperature. The simulated drift velocity with electric field dependencies is in a good agreement with experimental results found in literature. The saturation velocities for both polytypes are close, but the scattering rates are much more pronounced for 6H-SiC. Our simulation model clearly shows complete electron transport properties in 4H- and 6H-SiC.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗