Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MAGNETIC RESONANCE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,405 records · Page 78

31P MAS-NMR study of flux-grown rare-earth element orthophosphate (monazite/xenotime) solid solutions: Evidence of random cation distribution from paramagnetically shifted NMR resonances

We present 31P magic angle spinning nuclear magnetic resonance (MAS-NMR) spectra of flux-grown solid solutions of La1-xCexPO4 ( x between 0.027 and 0.32) having the monoclinic monazite structure, and of Y1-xMxPO4 (M = Vn+, Ce3+, Nd3+, x between 0.001 and 0.014) having the tetragonal zircon structure. Paramagnetically shifted NMR resonances are observed in all samples due to the presence of paramagnetic Vn+, Ce3+, and Nd3+ in the diamagnetic LaPO4 or YPO4. As a first-order observation, the number and relative intensity of these peaks is related to the symmetry and structure of the diamagnetic host phase. The presence of paramagnetic shifts allows for increased resolution between NMR resonances for distinct atomic species which leads to the observation of low intensity peaks related to PO4 species having more than one paramagnetic neighbor two or four atomic bonds away. Through careful analysis of peak areas and comparison with predictions for simple models, it was determined that solid solutions in the systems examined here are characterized by complete disorder (random distribution) of diamagnetic La3+ or Y3+ with the paramagnetic substitutional species Ce3+ and Nd3+. The increased resolution given by the paramagnetic interactions also leads to the observation of splitting of specific resonances in the 31P NMR spectra that may be caused by local, small-scale distortions from the substitution of ions having dissimilar ionic radii.

Palke, A. C.↗

Magnetic properties of the frustrated spin-$\frac{1}{2}$ capped-kagome antiferromagnet (CsBr)Cu 5 V 2 O 10

Here, the structural and magnetic properties of a spin-$\frac{1}{2}$ averievite (CsBr)⁢Cu 5⁢ V 2 ⁢O 10 are investigated by means of temperature-dependent x-ray diffraction, magnetization, heat capacity, and 51 V nuclear magnetic resonance (NMR) measurements. The crystal structure (trigonal, $P\bar{3}$) features a frustrated capped-kagome lattice of the magnetic Cu 2+ ions. Magnetic susceptibility analysis indicates a large Curie-Weiss temperature of $\theta$ CW ≃ -175K. Heat capacity signals the onset of a magnetic long-range-order (LRO) at T N ≃21.5K at zero magnetic field due to the presence of significant inter-planer coupling in this system. The magnetic LRO below 27 K is further evident from the drastic change in the 51 V NMR signal intensity and rapid enhancement in the 51 V spin-lattice relaxation rate in a magnetic field of 6.3 T. The frustration index ƒ=|⁢$\theta$ CW ⁢|/⁢T N ≃ 8 ascertains strong magnetic frustration in this compound. From the high-temperature value of the 51 V NMR spin-lattice relaxation rate, the leading antiferromagnetic exchange interaction between the Cu 2+ ions is calculated to be J/k B ≃ 136K.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

NMR determination of an incommensurate helical antiferromagnetic structure in EuCo 2 As 2

In this paper, we report 153 Eu, 75 As, and 59 Co nuclear magnetic resonance (NMR) results on EuCo 2 As 2 single crystal. Observations of 153 Eu and 75 As NMR spectra in zero magnetic field at 4.3 K below an antiferromagnetic (AFM) ordering temperature T N = 45 K and its external magnetic field dependence clearly evidence an incommensurate helical AFM structure in EuCo 2 As 2 . Furthermore, based on 59 Co NMR data in both the paramagnetic and the incommensurate AFM states, we have determined the model-independent value of the AFM propagation vector k = (0,0,0.73 ± 0.07)2π/c, where c is the c lattice parameter. Finally, the incommensurate helical AFM state was characterized by only NMR data with model-independent analyses, showing NMR to be a unique tool for determination of the spin structure in incommensurate helical AFMs.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

SU-C-BRD-05: Non-Invasive in Vivo Biodosimetry in Radiotherapy Patients Using Electron Paramagnetic Resonance (EPR) Spectroscopy

Purpose: Medical intervention following a major, unplanned radiation event can elevate the human whole body exposure LD50 from 3 to 7 Gy. On a large scale, intervention cannot be achieved effectively without accurate and efficient triage. Current methods of retrospective biodosimetry are restricted in capability and applicability; published human data is limited. We aim to further develop, validate, and optimize an automated field-deployable in vivo electron paramagnetic resonance (EPR) instrument that can fill this need. Methods: Ionizing radiation creates highly-stable, carbonate-based free radicals within tooth enamel. Using a process similar to nuclear magnetic resonance, EPR directly measures the presence of radiation-induced free radicals. We performed baseline EPR measurements on one of the upper central incisors of total body irradiation (TBI) and head and neck (H&N) radiotherapy patients before their first treatment. Additional measurements were performed between subsequent fractions to examine the EPR response with increasing radiation dose. Independent dosimetry measurements were performed with optically-stimulated luminescent dosimeters (OSLDs) and diodes to more accurately establish the relationship between EPR signal and delivered radiation dose. Results: 36 EPR measurements were performed over the course of four months on two TBI and four H & N radiotherapy patients. We observe a linear increase in EPR signal with increasing dose across the entirety of the tested range. A linear least squares-weighted fit of delivered dose versus measured signal amplitude yields an adjusted R-square of 0.966. The standard error of inverse prediction (SEIP) is 1.77 Gy. For doses up to 7 Gy, the range most relevant to triage, we calculate an SEIP of 1.29 Gy. Conclusion: EPR spectroscopy provides a promising method of retrospective, non-invasive, in vivo biodosimetry. Our preliminary data show an excellent correlation between predicted signal amplitude and delivered dose. With further development, a robust means of predicting delivered radiation dose from EPR measurements is expected. This project was funded by the Biomedical Advanced Research and Development Authority (BARDA) within the U.S. Department of Health and Human Services subcontracted through the Geisel School of Medicine at Dartmouth and by the Dartmouth Physically-Based Biodosimetry Center for Medical Countermeasures Against Radiation (Dart-Dose CMCR) Pilot Program.

60 APPLIED LIFE SCIENCES↗

Amyloid Structure and Assembly: Insights from Scanning Transmission Electron Microscopy

Amyloid fibrils are filamentous protein aggregates implicated in several common diseases such as Alzheimer's disease and type II diabetes. Similar structures are also the molecular principle of the infectious spongiform encephalopathies such as Creutzfeldt-Jakob disease in humans, scrapie in sheep, and of the so-called yeast prions, inherited non-chromosomal elements found in yeast and fungi. Scanning transmission electron microscopy (STEM) is often used to delineate the assembly mechanism and structural properties of amyloid aggregates. In this review we consider specifically contributions and limitations of STEM for the investigation of amyloid assembly pathways, fibril polymorphisms and structural models of amyloid fibrils. This type of microscopy provides the only method to directly measure the mass-per-length (MPL) of individual filaments. Made on both in vitro assembled and ex vivo samples, STEM mass measurements have illuminated the hierarchical relationships between amyloid fibrils and revealed that polymorphic fibrils and various globular oligomers can assemble simultaneously from a single polypeptide. The MPLs also impose strong constraints on possible packing schemes, assisting in molecular model building when combined with high-resolution methods like solid-state nuclear magnetic resonance (NMR) and electron paramagnetic resonance (EPR).

59 BASIC BIOLOGICAL SCIENCES↗

The fixed probe storage ring magnetometer for the Muon g-2 experiment at Fermi National Accelerator Laboratory

The goal of the FNAL E989 experiment is to measure the muon magnetic anomaly to unprecedented accuracy and precision at the Fermi National Accelerator Laboratory. To meet this goal, the time and space averaged magnetic environment in the muon storage volume must be known to better than 70 ppb. A new pulsed proton nuclear magnetic resonance (NMR) magnetometer was designed and built at the University of Washington, Seattle to track the temporal stability of the 1.45 T magnetic field in the muon storage ring at this precision. It consists of an array of 378 petroleum jelly based NMR probes that are embedded in the walls of muon storage ring vacuum chambers and custom electronics built with readily available modular radio frequency (RF) components. We give NMR probe construction details and describe the functions of the custom electronic subsystems. The excellent performance metrics of the magnetometer are discussed, where after 8 years of operation the median single shot resolution of the array of probes remains at 650 ppb.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-QI-19: Evaluation of a Clinical 1.5T MRI for Prostate Cancer MRS Imaging Using a In Vivo Tumor Model

Purpose: Magnetic resonance spectroscopic (MRS) imaging may provide important bio-markers to distinguish normal/cancerous prostate tissue. While MRS imaging requires a high uniform magnetic field, the ability of a clinical 1.5T MRI to achieve a comparable MRS signal is of interest for radiation treatment planning/assessment. This study is to evaluate the MRS imaging of a 1.5T clinical MRI for prostate cancers by comparing with a small animal 7T MRS scanner. Methods: A tumor model was developed by implanting LNCaP tumor cells in nude mice prostates. Tumor was monitored 3 weeks after implantation using MRI, and MRS imaging was performed on the tumor area when the tumor reached around 1cm in diameter. The 1.5T GE clinical MR scanner and the 7T Bruker small animal MR scanner were used for each mouse. MR spectrums acquired with these scanners were analyzed and compared. The signals of Choline and Citrate were considered. Results: The prostate tumor MR spectrum under the 1.5T clinical MRI showed a similar spectrum pattern to that acquired using the 7T animal MRI. The Choline signal (3.2ppm) is clear and there is no clear peak for Citrate (2.6ppm). However, the signal magnitude for Choline is not dominant compared to the background signal under 1.5T MRI. Typical cancerous prostate tissue MR spectrum with an increased Choline signal and a reduced Citrate signal was observed. In addition, signal variation is noticeable between repeated spectrum scans. The average of these scans showed a comparable and consistent spectrum to those under 7T MRI. Conclusion: The clinical 1.5T MRI is able to acquire a MR spectrum for prostate cancer comparable to those acquired using a dedicated 7T MRS scanner. However, to achieve a consistent and reliable spectrum, multiple repeated scans were necessary to get a statistical result and reduce the noise-induced artifact. This work was supported in part by the National Cancer Institute Grant R21 CA131979 and R01CA172638.

60 APPLIED LIFE SCIENCES↗

Predictive Modeling in Actinide Chemistry and Catalysis

These are slides from a presentation on predictive modeling in actinide chemistry and catalysis. The following topics are covered in these slides: Structures, bonding, and reactivity (bonding can be quantified by optical probes and theory, and electronic structures and reaction mechanisms of actinide complexes); Magnetic resonance properties (transition metal catalysts with multi-nuclear centers, and NMR/EPR parameters); Moving to more complex systems (surface chemistry of nanomaterials, and interactions of ligands with nanoparticles); Path forward and conclusions.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Robust absolute magnetometry with organic thin-film devices

Magnetic field sensors based on organic thin-film materials have attracted considerable interest in recent years as they can be manufactured at very low cost and on flexible substrates. However, the technological relevance of such magnetoresistive sensors is limited owing to their narrow magnetic field ranges (~30mT) and the continuous calibration required to compensate temperature fluctuations and material degradation. Conversely, magnetic resonance (MR)- based sensors, which utilize fundamental physical relationships for extremely precise measurements of fields, are usually large and expensive. Here we demonstrate an organic magnetic resonance-based magnetometer, employing spin-dependent electronic transitions in an organic diode, which combines the low-cost thin-film fabrication and integration properties of organic electronics with the precision of a MR-based sensor. We show that the device never requires calibration, operates over large temperature and magnetic field ranges, is robust against materials degradation and allows for absolute sensitivities of <50nTHz -1/2 .

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Modified Newton-Raphson GRAPE methods for optimal control of spin systems

Quadratic convergence throughout the active space is achieved for the gradient ascent pulse engineering (GRAPE) family of quantum optimal control algorithms. We demonstrate in this communication that the Hessian of the GRAPE fidelity functional is unusually cheap, having the same asymptotic complexity scaling as the functional itself. This leads to the possibility of using very efficient numerical optimization techniques. In particular, the Newton-Raphson method with a rational function optimization (RFO) regularized Hessian is shown in this work to require fewer system trajectory evaluations than any other algorithm in the GRAPE family. This communication describes algebraic and numerical implementation aspects (matrix exponential recycling, Hessian regularization, etc.) for the RFO Newton-Raphson version of GRAPE and reports benchmarks for common spin state control problems in magnetic resonance spectroscopy.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

L-H transition trigger physics in ITER-similar plasmas with applied n = 3 magnetic perturbations

The L–H transition power threshold PLH is observed to increase with applied n = 3 resonant magnetic perturbations (RMP) in ITER-similar-shape plasmas with balanced neutral beam torque injection in DIII-D. The increase is most pronounced with added electron–cyclotron heating: PLH increases with decreasing edge plasma collisionality as PLH/PLH-08 ~ (ν*)−0.5, where PLH-08 is the 2008 ITPA multi-machine power threshold scaling. This result raises concerns for H-mode access at low edge collisionality in ITER, where RMP may have to be applied before the L–H transition to safely suppress the first edge-localized mode. Non-axisymmetric modifications with RMP include a simultaneous reduction of the radial electric field (Er) well depth and E × B shear. This can be attributed to increasing edge toroidal co-current rotation, and is consistent with substantially increased local long-wavelength turbulence (measured via beam emission spectroscopy). At high RMP perturbation strength the edge electric field Er reverses sign locally (becomes positive), with changes in dominant turbulence modes. Edge magnetic stochasticity provides an attractive explanation of the observed modifications, and the observed changes in toroidal rotation and Er are consistent with a simple fluid model describing radial electron current flow along stochastic fieldlines. The observed collisionality dependence of the L-mode edge electric field with applied RMP is also qualitatively consistent with this model. Reflectometry data indicate a significant reduction of the normalized L-mode radial density gradient a/Ln at high RMP field with simultaneous increase in radial particle flux and electron thermal flux from power balance analysis. We conjecture that the increase of PLH with RMP results from the combined effects of reduced E × B flow shear (increasing turbulent transport levels) and toroidal/poloidal flow modulation due to edge stochasticity. Initial experiments indicate that non-resonant n = 3 magnetic perturbations lead only to relatively small changes in Er, E × B shear and fluctuation characteristics, and have less impact on the L–H transition power threshold. This motivates further exploration of the RMP spectrum dependence of PLH for possible mitigation of the observed threshold increase.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Coexisting structural disorder and robust spin-polarization in half-metallic FeMnVAl

We report half-metallic ferromagnets (HMFs) are one of the most promising materials in the field of spintronics due to their unique band structure, consisting of one spin subband having metallic characteristics along with another subband with semiconductor-like behavior. In this work, we report the synthesis of a novel quaternary Heusler alloy—FeMnVAl—and we have studied the structural, magnetic, transport, and electronic properties complemented with first-principles calculations. Among different possible structurally ordered arrangements, the optimal structure is identified by theoretical energy minimization. The corresponding spin-polarized band-structure calculations indicate the presence of a half-metallic ferromagnetic ground state. A detailed and careful investigation of the x-ray diffraction data, Mössbauer spectra, and nuclear magnetic resonance spectra suggests the presence of site disorder between the Fe and Mn atoms in the stable ordered structure of the system. The magnetic susceptibility measurement clearly establishes a ferromagnetic-like transition below ~213 K. The Fe Mössbauer spectrometry measurements suggest that only the Mn spins could be responsible for the magnetic order, which is consistent with our theoretical calculation. Surprisingly, the density-functional-theory calculations reveal that the spin-polarization value is almost immunized (92.4% → 90.4%) from the Mn-Fe structural disorder, even when nonmagnetic Fe and moment-carrying Mn sites are entangled inseparably. The robustness of spin polarization and half-metallicity in the studied FeMnVAl compound comprising structural disorder is thus quite interesting and could provide a new direction to investigate and understand the exact role of disorders on spin polarization in this class of materials, beyond the available knowledge.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Effect of Hyperoxygenation on Tissue pO{sub 2} and Its Effect on Radiotherapeutic Efficacy of Orthotopic F98 Gliomas

Purpose: Lack of methods for repeated assessment of tumor pO{sub 2} limits the ability to test and optimize hypoxia-modifying procedures being developed for clinical applications. We report repeated measurements of orthotopic F98 tumor pO{sub 2} and relate this to the effect of carbogen inhalation on tumor growth when combined with hypofractionated radiotherapy. Methods and Materials: Electron paramagnetic resonance (EPR) oximetry was used for repeated measurements of tumor and contralateral brain pO{sub 2} in rats during 30% O{sub 2} and carbogen inhalation for 5 consecutive days. The T{sub 1}-enhanced volumes and diffusion coefficients of the tumors were assessed by magnetic resonance imaging (MRI). The tumors were irradiated with 9.3 Gy x 4 fractions in rats breathing 30% O{sub 2} or carbogen to determine the effect on tumor growth. Results: The pretreatment F98 tumor pO{sub 2} varied between 8 and 16 mmHg, while the contralateral brain had 41 to 45 mmHg pO{sub 2} during repeated measurements. Carbogen breathing led to a significant increase in tumor and contralateral brain pO{sub 2}; however, this effect declined over days. Irradiation of the tumors in rats breathing carbogen resulted in a significant decrease in tumor growth and an increase in the diffusion coefficient measured by MRI. Conclusions: The results provide quantitative measurements of the effect of carbogen inhalation on intracerebral tumor pO{sub 2} and its effect on therapeutic outcome. Such direct repeated pO{sub 2} measurements by EPR oximetry can provide temporal information that could be used to improve therapeutic outcome by scheduling doses at times of improved tumor oxygenation. EPR oximetry is currently being tested for clinical applications.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Uniaxial strain control of spin-polarization in multicomponent nematic order of BaFe 2 As 2

The iron-based high temperature superconductors exhibit a rich phase diagram reflecting a complex interplay between spin, lattice, and orbital degrees of freedom. The nematic state observed in these compounds epitomizes this complexity, by entangling a real-space anisotropy in the spin fluctuation spectrum with ferro-orbital order and an orthorhombic lattice distortion. A subtle and less-explored facet of the interplay between these degrees of freedom arises from the sizable spin-orbit coupling present in these systems, which translates anisotropies in real space into anisotropies in spin space. We present nuclear magnetic resonance studies, which reveal that the magnetic fluctuation spectrum in the paramagnetic phase of BaFe 2 As 2 acquires an anisotropic response in spin-space upon application of a tetragonal symmetry-breaking strain field. Lastly, our results unveil an internal spin structure of the nematic order parameter, indicating that electronic nematic materials may offer a route to magneto-mechanical control.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Roles of effective helical ripple rates in nonlinear stability of externally induced magnetic islands

Magnetic islands are externally produced by resonant magnetic perturbations (RMPs) in toroidal plasmas. Spontaneous annihilation of RMP-induced magnetic islands called self-healing has been observed in helical systems. A possible mechanism of the self-healing is shielding of RMP penetration by helical ripple-induced neoclassical flows, which give rise to neoclassical viscous torques. In this study, effective helical ripple rates in multi-helicity helical systems are revisited, and a multi-helicity effect on the self-healing is investigated, based on a theoretical model of rotating magnetic islands. It is confirmed that effective helical ripple rates are sensitive to magnetic axis positions. It is newly found that self-healing thresholds also strongly depend on magnetic axis positions, which is due to dependence of neoclassical viscous torques on effective helical ripple rates.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗