Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MAGNET SYSTEM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,405 records · Page 78

Repeated action of a constant magnetic field on the blood coagulation system in artificially produced anemia

Changes are discussed in the coagulatory system of the blood in rabbits under the influence of a constant magnetic field of an intensity of 2500 oersteds against the background of artificially induced anemia. Reversibility of the changes produced and the presence of the adaptational effect are noted. Taking all this into consideration, the changes involving the coagulatory system of the blood which arise under the influence of a constant magnetic field may be considered to have a nerve-reflex nature.

Zabrodina, L. V.↗

First-principles and model simulation of all-optical spin reversal

All-optical spin switching is a potential trailblazer for information storage and communication at an unprecedented fast rate free of magnetic fields. However, the current wisdom is largely based on semiempirical models of effective magnetic fields and heat pulses, so it is difficult to provide high-speed design protocols for actual devices. In this paper we carry out a massively parallel first-principles and model calculation for 13 spin systems and magnetic layers, free of any effective field, to establish a simpler and alternative paradigm of laser-induced ultrafast spin reversal and to point out a path to a full-integrated photospintronic device. It is the interplay of the optical selection rule and sublattice spin orderings that underlines seemingly irreconcilable helicity-dependent and -independent switchings. Using realistic experimental parameters, we predict that strong ferrimagnets, in particular, Laves phase C15 rare-earth alloys, meet the telecommunication energy requirement of 10 fJ, thus allowing a cost-effective subpicosecond laser to switch spin in the gigahertz region.

36 MATERIALS SCIENCE↗

Tuning magnetism of monolayer MoS{sub 2} by doping vacancy and applying strain

In view of important role of inducing and manipulating the magnetism in two-dimensional materials for the development of low-dimensional spintronic devices, the influences of strain on electronic structure and magnetic properties of commonly observed vacancies doped monolayer MoS{sub 2} are investigated using first-principles calculations. It is shown that unstrained V{sub S}, V{sub S2}, and V{sub MoS3} doped monolayer MoS{sub 2} systems are nonmagnetic, while the ground state of unstrained V{sub MoS6} doped system is magnetic and the magnetic moment is contributed mainly by six Mo atoms around V{sub MoS6}. In particular, tensile strain can induce magnetic moments in V{sub S}, V{sub S2}, and V{sub MoS3} doped monolayer MoS{sub 2} due to the breaking of Mo–Mo metallic bonds around the vacancies, while the magnetization induced by V{sub MoS6} can be effectively manipulated by equibiaxial strain due to the change of Mo–Mo metallic bonds around V{sub MoS6} under strains.

36 MATERIALS SCIENCE↗

An Assessment of Integrated Flywheel System Technology

The current state of the technology in flywheel storage systems and ancillary components, the technology in light of future requirements, and technology development needs to rectify these shortfalls were identified. Technology efforts conducted in Europe and in the United States were reviewed. Results of developments in composite material rotors, magnetic suspension systems, motor/generators and electronics, and system dynamics and control were presented. The technology issues for the various disciplines and technology enhancement scenarios are discussed. A summary of the workshop, and conclusions and recommendations are presented.

Keckler, C. R.↗

Pressure dependence of the magnetic ground state in CePtSi 2

CePtSi 2 was reported to exhibit an antiferromagnetic order below T*=1.8 K at ambient pressure, a valence state change at ~1.2 GPa, and superconductivity in the range between 1.4 and 2.1 GPa with a maximum transition temperature of 0.14 K [T. Nakano et al., Phys. Rev. B 79, 172507 (2009)]. We have performed polycrystalline and single-crystal neutron diffraction experiments to determine the magnetic structure under ambient and high pressures. We found incommensurate magnetic peaks with a magnetic propagation vector of (0.32,0,0.11) at ambient pressure below T SDW ~ 1.25 K. Those magnetic peaks originate from a spin-density-wave order with the easy axis along the c axis and an averaged ordered moment of 0.45(5) μB , suggesting that there may be an intermediate phase between T* and T SDW . Applying pressures, the magnetic propagation vector shows no change and the magnetic order disappears around 1.0 GPa, which is much lower than the critical pressure for the superconducting phase. The results suggest that other than magnetic fluctuations may play a primary role in the superconducting pairing mechanism.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Disorder-induced spin excitation continuum and spin-glass ground state in the inverse spinel CuGa 2 O 4

Spinel-structured compounds serve as prototypical examples of highly frustrated systems and are promising candidates for realizing the long-sought quantum spin liquid (QSL) state. However, structural disorder is inevitable in many real QSL candidates and its impact remains a topic of intense debate. In this work, we conduct comprehensive investigations on CuGa 2 ⁢ O 4 , a spinel compound with significant structural disorder, focusing on its thermodynamic properties and spectroscopic behaviors. No long-range magnetic order is observed down to ∼80 mK, as evidenced by magnetic susceptibility, specific-heat, and elastic neutron scattering measurements. More intriguingly, inelastic neutron scattering experiments reveal a broad gapless continuum of magnetic excitations around the Brillouin zone boundary, resembling the magnetic excitation spectra expected for a QSL. Nevertheless, a spin-freezing transition at 𝑇 f ≈ 0.88 K is identified from the cusp in the dc susceptibility curves, where a bifurcation between zero-field-cooling and field-cooling curves occurs. Furthermore, ac susceptibility measurements show a peak close to 𝑇 f at low frequency, which shifts to higher temperature with increasing frequency. These results show that CuGa 2 ⁢ O 4 has a spin-glass ground state, consistent with the establishment of short-range order inferred from the specific-heat measurements. Collectively, these results illustrate the crucial role of disorder in defining the excitation spectrum out of the disordered ground state. Furthermore, our findings shed light onto the broader class of 𝐴⁢𝐵 2 ⁢O 4 spinels and advance our understanding of the spin dynamics in magnetically disordered systems.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Magneto-inertial fusion with laser compression of a magnetized spherical target

The paper is devoted to the principles of magneto-inertial fusion and laser-plasma methods of generation of a Megagauss field during spherical implosion of a magnetized target. A model based on a magnetic confinement system, namely, a cusp configuration with inertial compression of the target by a laser driver, is developed. The dynamics of plasma in a cusp compressed under the effect of laser beams is precalculated. Analytical and numerical estimates of the particle number and magnetic field intensity during magneto-inertial plasma compression are obtained. The problems of irradiation of a spherically closed volume by a high-energy laser pulse are discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Strategies to perform magnetization reversals in ferromagnets

Systems and methods for reversing a magnetization in a ferromagnet include a nanometer-scale cylindrical ferromagnetic sample having a height to diameter aspect ratio on the order of 2 or greater. A temporally-varying external field comprising an r.f. Pi pulse is applied to the ferromagnetic sample to cause a precession magnetization vector inclined at an angle with respect to the longest axis of the ferromagnetic sample to continuously rotate around the longest axis. One or more parameters of the temporally-varying external field is continuously adjusted based on at least magnetization dynamics of the ferromagnetic sample and/or an angular dependence of a precession frequency of the ferromagnetic sample.

Ketterson, John B.↗

Superferrimagnetism in hard Nd-Fe-B thick films, an original concept for coercivity enhancement

In a number of applications (automotive, wind generators), RFeB magnets are parts of systems which operate at temperatures in the range of 160 °C–180 °C. At these high temperatures, coercivity is preserved by substituting Dy atoms for a part of the Nd ones. The enhanced coercivity obtained may be associated to the high magnetocrystalline anisotropy of Dy atoms, which diffuse into the R{sub 2}Fe{sub 14}B phase. The introduction of Dy, however, induces a reduction in the remanent magnetization. Furthermore, Dy is an expensive and strategic material. In this study, we explore a radically different approach to coercivity. A magnetic layer is deposited at the surface of the hard grains, this layer being exchange coupled to the main hard phase in a way that its magnetization is antiparallel to it. Under an applied field that tends to reverse the main phase magnetization, the surface layer, the magnetization of which is along the field, works against reversal. This is the concept of superferrimagnetism. In order to test its impact on the coercivity of real systems, magnetically hard thick films of NdFeB have been sandwiched between thin layers of Gd/Fe, which were transformed to GdFe{sub 2} upon annealing. Coercivity enhancement was achieved compared to a reference NdFeB single layer.

36 MATERIALS SCIENCE↗

Three-Dimensional Dosimetric Validation of a Magnetic Resonance Guided Intensity Modulated Radiation Therapy System

Purpose: To validate the dosimetric accuracy of a commercially available magnetic resonance guided intensity modulated radiation therapy (MRgIMRT) system using a hybrid approach: 3-dimensional (3D) measurements and Monte Carlo calculations. Methods and Materials: We used PRESAGE radiochromic plastic dosimeters with remote optical computed tomography readout to perform 3D high-resolution measurements, following a novel remote dosimetry protocol. We followed the intensity modulated radiation therapy commissioning recommendations of American Association of Physicists in Medicine Task Group 119, adapted to incorporate 3D data. Preliminary tests (“AP” and “3D-Bands”) were delivered to 9.5-cm usable diameter cylindrical PRESAGE dosimeters to validate the treatment planning system (TPS) for nonmodulated deliveries; assess the sensitivity, uniformity, and rotational symmetry of the PRESAGE dosimeters; and test the robustness of the remote dosimetry protocol. Following this, 4 clinical MRgIMRT plans (“MultiTarget,” “Prostate,” “Head/Neck,” and “C-Shape”) were measured using 13-cm usable diameter PRESAGE dosimeters. For all plans, 3D-γ (3% or 3 mm global, 10% threshold) passing rates were calculated and 3D-γ maps were examined. Point doses were measured with an IBA-CC01 ionization chamber for validation of absolute dose. Finally, by use of an in-house-developed, GPU-accelerated Monte Carlo algorithm (gPENELOPE), we independently calculated dose for all 6 Task Group 119 plans and compared against the TPS. Results: For PRESAGE measurements, 3D-γ analysis yielded passing rates of 98.7%, 99.2%, 98.5%, 98.0%, 99.2%, and 90.7% for AP, 3D-Bands, MultiTarget, Prostate, Head/Neck, and C-Shape, respectively. Ion chamber measurements were within an average of 0.5% (±1.1%) from the TPS dose. Monte Carlo calculations demonstrated good agreement with the TPS, with a mean 3D-γ passing rate of 98.5% ± 1.9% using a stricter 2%/2-mm criterion. Conclusions: We have validated the dosimetric accuracy of a commercial MRgIMRT system using high-resolution 3D techniques. We have demonstrated for the first time that hybrid 3D remote dosimetry is a comprehensive and feasible approach to commissioning MRgIMRT. This may provide better sensitivity in error detection compared with standard 2-dimensional measurements and could be used when implementing complex new magnetic resonance guided radiation therapy technologies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Quantitative magnetic imaging at the nanometer scale by ballistic electron magnetic microscopy

We demonstrate quantitative ballistic electron magnetic microscopy (BEMM) imaging of simple model Fe(001) nanostructures. We use in situ nanostencil shadow mask resistless patterning combined with molecular beam epitaxy deposition to prepare under ultra-high vacuum conditions nanostructured epitaxial Fe/Au/Fe/GaAs(001) spin-valves. In this epitaxial system, the magnetization of the bottom Fe/GaAs(001) electrode is parallel to the [110] direction, defining accurately the analysis direction for the BEMM experiments. The large hot-electron magnetoresistance of the Fe/Au/Fe/GaAs(001) epitaxial spin-valve allows us to image various stable magnetic configurations on the as-grown Fe(001) microstructures with a high sensitivity, even for small misalignments of both magnetic electrodes. The angular dependence of the hot-electron magnetocurrent is used to convert magnetization maps calculated by micromagnetic simulations into simulated BEMM images. The calculated BEMM images and magnetization rotation profiles show quantitative agreement with experiments and allow us to investigate the magnetic phase diagram of these model Fe(001) microstructures. Finally, magnetic domain reversals are observed under high current density pulses. This opens the way for further BEMM investigations of current-induced magnetization dynamics.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A TOPAS model for lens-based proton radiography

Abstract Objective. Proton Radiography can be used in conjunction with proton therapy for patient positioning, real-time estimates of stopping power, and adaptive therapy in regions with motion. The modeling capability shown here can be used to evaluate lens-based radiography as an instantaneous proton-based radiographic technique. The utilization of user-friendly Monte Carlo program TOPAS enables collaborators and other users to easily conduct medical- and therapy- based simulations of the Los Alamos Neutron Science Center (LANSCE). The resulting transport model is an open-source Monte Carlo package for simulations of proton and heavy ion therapy treatments and concurrent particle imaging. Approach. The four-quadrupole, magnetic lens system of the 800-MeV proton beamline at LANSCE is modeled in TOPAS. Several imaging and contrast objects were modelled to assess transmission at energies from 230–930 MeV and different levels of particle collimation. At different proton energies, the strength of the magnetic field was scaled according to βγ, the inverse product of particle relativistic velocity and particle momentum. Main results. Materials with high atomic number, Z, (gold, gallium, bone-equivalent) generated more contrast than materials with low-Z (water, lung-equivalent, adipose-equivalent). A 5-mrad collimator was beneficial for tissue-to-contrast agent contrast, while a 10-mrad collimator was best to distinguish between different high-Z materials. Assessment with a step-wedge phantom showed water-equivalent path length did not scale directly according to predicted values but could be mapped more accurately with calibration. Poor image quality was observed at low energies (230 MeV), but improved as proton energy increased, with sub-mm resolution at 630 MeV. Significance. Proton radiography becomes viable for shallow bone structures at 330 MeV, and for deeper structures at 630 MeV. Visibility improves with use of high-Z contrast agents. This modality may be particularly viable at carbon therapy centers with accelerators capable of delivering high energy protons and could be performed with carbon therapy.

60 APPLIED LIFE SCIENCES↗

Kinetic arrest of field-temperature induced first order phase transition in quasi-one dimensional spin system Ca{sub 3}Co{sub 2}O{sub 6}

We have found that the geometrically frustrated spin chain compound Ca{sub 3}Co{sub 2}O{sub 6} belonging to Ising like universality class with uniaxial anisotropy shows kinetic arrest of first order intermediate phase (IP) to ferrimagnetic (FIM) transition. In this system, dc magnetization measurements followed by different protocols suggest the coexistence of high temperature IP with equilibrium FIM phase in low temperature. Formation of metastable state due to hindered first order transition has also been probed through cooling and heating in unequal field (CHUF) protocol. Kinetically arrested high temperature IP appears to persist down to almost the spin freezing temperature in this system.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

ON THE INJECTION OF HELICITY BY THE SHEARING MOTION OF FLUXES IN RELATION TO FLARES AND CORONAL MASS EJECTIONS

An investigation of helicity injection by photospheric shear motions is carried out for two active regions (ARs), NOAA 11158 and 11166, using line-of-sight magnetic field observations obtained from the Helioseismic and Magnetic Imager on board the Solar Dynamics Observatory. We derived the horizontal velocities in the ARs from the differential affine velocity estimator (DAVE) technique. Persistent strong shear motions at maximum velocities in the range of 0.6-0.9 km s{sup -1} along the magnetic polarity inversion line and outward flows from the peripheral regions of the sunspots were observed in the two ARs. The helicities injected in NOAA 11158 and 11166 during their six-day evolution period were estimated as 14.16 Multiplication-Sign 10{sup 42} Mx{sup 2} and 9.5 Multiplication-Sign 10{sup 42} Mx{sup 2}, respectively. The estimated injection rates decreased up to 13% by increasing the time interval between the magnetograms from 12 minutes to 36 minutes, and increased up to 9% by decreasing the DAVE window size from 21 Multiplication-Sign 18 to 9 Multiplication-Sign 6 pixel{sup 2}, resulting in 10% variation in the accumulated helicity. In both ARs, the flare-prone regions (R2) had inhomogeneous helicity flux distribution with mixed helicities of both signs and coronal mass ejection (CME) prone regions had almost homogeneous distribution of helicity flux dominated by a single sign. The temporal profiles of helicity injection showed impulsive variations during some flares/CMEs due to negative helicity injection into the dominant region of positive helicity flux. A quantitative analysis reveals a marginally significant association of helicity flux with CMEs but not flares in AR 11158, while for the AR 11166, we find a marginally significant association of helicity flux with flares but not CMEs, providing evidence of the role of helicity injection at localized sites of the events. These short-term variations of helicity flux are further discussed in view of possible flare-related effects. This study suggests that flux motions and spatial distribution of helicity injection are important to understanding the complex nature of the magnetic flux system of the AR, and how it can lead to conditions favorable for eruptive events.

79 ASTRONOMY AND ASTROPHYSICS↗

Magnetic charge propagation upon a 3D artificial spin-ice

Magnetic charge propagation in spin-ice materials has yielded a paradigm-shift in science, allowing the symmetry between electricity and magnetism to be studied. Recent work is now suggesting the spin-ice surface may be important in mediating the ordering and associated phase space in such materials. Here, we detail a 3D artificial spin-ice, which captures the exact geometry of bulk systems, allowing magnetic charge dynamics to be directly visualized upon the surface. Using magnetic force microscopy, we observe vastly different magnetic charge dynamics along two principal directions. For a field applied along the surface termination, local energetics force magnetic charges to nucleate over a larger characteristic distance, reducing their magnetic Coulomb interaction and producing uncorrelated monopoles. In contrast, applying a field transverse to the surface termination yields highly correlated monopole-antimonopole pairs. Detailed simulations suggest it is the difference in effective chemical potential as well as the energy landscape experienced during dynamics that yields the striking differences in monopole transport.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Increasing the magnetic-field capability of the magneto-inertial fusion electrical discharge system using an inductively coupled coil

Magnetized high energy density physics (HEDP) is a very active and relatively unexplored field that has applications in inertial confinement fusion, astrophysical plasma science, and basic plasma physics. A self-contained device, the Magneto-Inertial Fusion Electrical Discharge System, MIFEDS [G. Fiksel et al., Rev. Sci. Instrum. 86, 016105 (2015)], was developed at the Laboratory for Laser Energetics to conduct magnetized HEDP experiments on both the OMEGA [T. R. Boehly et al., Opt. Commun. 133, 495–506 (1997)] and OMEGA EP [J. H. Kelly et al., J. Phys. IV France 133, 75 (2006) and L. J. Waxer et al., Opt. Photonics News 16, 30 (2005)] laser systems. Extremely high magnetic fields are a necessity for magnetized HEDP, and the need for stronger magnetic fields continues to drive the redevelopment of the MIFEDS device. It is proposed in this paper that a magnetic coil that is inductively coupled rather than directly connecting to the MIFEDS device can increase the overall strength of the magnetic field for HEDP experiments by increasing the efficiency of energy transfer while decreasing the effective magnetized volume. A brief explanation of the energy delivery of the MIFEDS device illustrates the benefit of inductive coupling and is compared to that of direct connection for varying coil size and geometry. Finally, a prototype was constructed to demonstrate a 7-fold increase in energy delivery using inductive coupling.

47 OTHER INSTRUMENTATION↗