Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Incentives”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,405 records · Page 78

Close Look at Hybrid Vehicle Loyalty and Ownership

In a news release dated April 9, 2012, Polk stated that only 35% of hybrid owners bought a hybrid again when they returned to market in 2011. These findings were based on an internal study conducted by Polk. The study also indicated that if repurchase behavior among the high volume audience of Toyota Prius owners wasn t factored in; hybrid loyalty would drop to under 25%. This news release has generated a lot of interest and concern by the automobile industry as well as consumers, since it was published, and caused many to think about the idea of hybrid loyalty as well as factors that influence consumers. Most reactions to the 35% hybrid loyalty dealt with concerns of the viability of hybrid technology as part of the solution to address transportation energy challenges. This paper attempts to shed more light on Polk s hybrid loyalty study as well as explore several information sources concerning hybrid loyalty status. Specifically, major factors that might impact the selection and acquisition of hybrid vehicles are addressed. This includes investigating the associations between hybrid market shares and influencing factors like fuel price and hybrid incentives, as well as the availability of hybrid models and other highly fuel efficient vehicle options. This effort is not in-depth study, but rather a short study to see if Polk s claim could be validated. This study reveals that Polk s claim was rather misleading because its definition of loyalty was very narrow. This paper also suggests that Polk s analysis failed to account for some very important factors, raising the question of whether it is fair to compare a vehicle drive train option (which hybrids are) with a vehicle brand in terms of loyalty and also raises the question of whether hybrid loyalty is even a valid point to consider. This report maintains that Polk s study does not prove that hybrid owners were dissatisfied with their vehicles, which was a common theme among reporting news agencies when Polk initially released their findings. In this brief review, the team has looked at factors that might contribute to a consumer choosing to not purchase a hybrid; including the increase in manufacture s overall vehicle mpg and the percentage of the vehicle market owned by hybrids.

Hwang, Ho-Ling↗

Performance improvements in commercial heat pump water heaters using carbon dioxide

Although heat pump water heaters are today widely accepted in Japan, where energy costs are high and government incentives for their use exist, acceptance of such a product in the U.S. has been slow. This trend is slowly changing with the introduction of heat pump water heaters into the residential market, but remains in the commercial sector. Barriers to heat pump water heater acceptance in the commercial market have historically been performance, reliability and first/operating costs. The use of carbon dioxide (R744) as the refrigerant in such a system can improve performance for relatively small increase in initial cost and make this technology more appealing. What makes R744 an excellent candidate for use in heat pump water heaters is not only the wide range of ambient temperatures within which it can operate, but also the excellent ability to match water to refrigerant temperatures on the high side, resulting in very high exit water temperatures of up to 82ºC (180ºF), as required by sanitary codes in the U.S.(Food Code, 2005), in a single pass, temperatures that are much more difficult to reach with other refrigerants. This can be especially attractive in applications where this water is used for the purpose of sanitation. While reliability has also been of concern historically, dramatic improvements have been made over the last several years through research done in the automotive industry and commercialization of R744 technology in residential water heating mainly in Japan. This paper presents the performance results from the development of an R744 commercial heat pump water heater of approximately 35kW and a comparison to a baseline R134a unit of the same capacity and footprint. In addition, recommendations are made for further improvements of the R744 system which could result in possible energy savings of up to 20%.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Development of High Efficiency Carbon Dioxide Commercial Heat Pump Water Heater

Although heat pump water heaters are today widely accepted in both Japan and Europe, where energy costs are high and government incentives for their use exist, acceptance of such products in the US has been limited. While this trend is slowly changing with the introduction of heat pump water heaters into the residential market, but acceptance remains low in the commercial sector. The objective of the presented work is the development of a high efficiency R744 heat pump water heater for commercial applications with effective utilization of the cooling capability for air conditioning and/or refrigeration. The ultimate goal is to achieve total system COP of up to 8. This unit will be targeted at commercial use where some cooling load is typically needed year round, such as restaurants, hotels, nursing homes, and hospitals. This paper presents the performance results from the development of four R744 commercial heat pump water heater packages of approximately 35 kW and comparison to a commercially available baseline R134a unit of the same capacity and footprint. In addition, the influences of an internal heat exchanger and an enhanced evaporator on the system performance are described and recommendations are made for further improvements of the R744 system.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Next generation commercial heat pumpwater heater using carbon dioxide using different improvement approaches

Although heat pump water heaters are today widely accepted in Japan, where energy costs are high and government incentives for their use exist, acceptance of such a product in the U.S. has been slow. This trend is slowly changing with the introduction of heat pump water heaters into the residential market, but remains in the commercial sector. Barriers to heat pump water heater acceptance in the commercial market have historically been performance, reliability and first/operating costs. The use of carbon dioxide (R744) as the refrigerant in such a system can improve performance for relatively small increase in initial cost and make this technology more appealing. What makes R744 an excellent candidate for use in heat pump water heaters is not only the wide range of ambient temperatures within which it can operate, but also the excellent ability to match water to refrigerant temperatures on the high side, resulting in very high exit water temperatures of up to 82ºC, as required by sanitary codes in the U.S. (Food Code, 2005), in a single pass, temperatures that are much more difficult to reach with other refrigerants. This can be especially attractive in applications where this water is used for the purpose of sanitation. While reliability has also been of concern historically, dramatic improvements have been made over the last several years through research done in the automotive industry and commercialization of R744 technology in residential water heating mainly in Japan. This paper presents the performance results from the development of an R744 commercial heat pump water heater of approximately 35 kW and a comparison to a baseline R134a unit of the same capacity and footprint. In addition, recommendations are made for further improvements of the R744 system which could result in possible energy savings of up to 20 %.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Stable Whole Building Performance Method for Standard 90.1

Wouldn’t it be great if a single energy model could be used to demonstrate minimum code compliance, green code compliance, establish a Leadership in Energy and Environmental Design (LEED) rating, and determine eligibility for federal tax and utility incentives? Even better, what if the basic rules for creating those models did not change every few years? This paper descibes a recently proposed addendum to ASHRAE/ANSI/IES Standard 90.1 aims to meet those goals. Addendum BM establishes the Performance Rating Method found in Appendix G of Standard 90.1 as a new method of compliance while maintaining its traditional use in gauging the efficiency of beyond code buildings. Furthermore, Addendum BM sets a common baseline building that does not change with each update to the standard.

ASHRAE Standard 90.1, Performance Rating Method, E↗

Grassland Bird Distribution and Raptor Flight Patterns in the Competitive Renewable Energy Zones of the Texas Panhandle [Thesis]

The consistent wind resource in the Great Plains of North America has encouraged the development of wind energy facilities across this region. In the Texas Panhandle, a high quality wind resource is only one factor that has led to the expansion of wind energy development. Other factors include federal tax incentives and the availability of subsidies. Moreover, the State Renewable Portfolio Standards (RPS), mandating production of 10,000 mega-watts of renewable energy in the state by 2025, has contributed to an amicable regulatory and permitting environment (State Energy Conservation Office 2010). Considering the current rate of development, the RPS will be met in coming years (American Wind Energy Association 2011) and the rate of development is likely to continue. To meet increased energy demands in the face of a chronically constrained transmission grid, Texas has developed a comprehensive plan that organizes and prioritizes new transmission systems in high quality wind resource areas called Competitive Renewable Energy Zones (CREZ). The CREZ plan provides developers a solution to transmission constraints and unlocks large areas of undeveloped wind resource areas. In the northern Texas panhandle, there are two CREZs that are classified Class 3 wind (Class 5 is the highest) and range from 862,725 to 1,772,328 ha in size (Public Utility Commission of Texas 2008). Grassland bird populations have declined more than any other bird group in North America (Peterjohn and Sauer 1999, Sauer et al. 2004). Loss of grassland habitat from agricultural development has been the greatest contributor to the decline of grassland bird populations, but development of non-renewable (i.e., oil, coal, and gas) and renewable energy (i.e., wind, solar, biomass, and geothermal) sources have contributed to the decline as well (Pimentel et al. 2002, Maybe and Paul 2007). The effects of wind energy development on declining grassland bird populations has become an area of extensive research, as we attempt to understand and minimize potential impacts of a growing energy sector on declining bird populations. Based on data from post-construction fatality surveys, two grassland bird groups have been the specific focus of research, passerines (songbird guild) and raptors (birds of prey). The effects of wind energy development on these two groups of birds, both of conservation concern, have been examined over the last decade. The primary focus of this research has been on mortality resulting from collision with wind turbines (Kuvlesky et al. 2007). Most studies just quantify post-construction fatality levels (e.g., Erickson et al. 2002) while very few studies provide a comparison of bird populations prior to development through a Before-After-Control-Impact (BACI) study design. Before-After-Control-Impact studies provide powerful evidence of avian/wind energy relationships (Anderson et al. 1999). Despite repeated urgency on conducting these types of studies (Anderson et al. 1999, Madders and Whitfield 2006, Kuvelsky et al. 2007), few have been conducted in North America. Although several European researchers (Larsson 1994, de Lucas et al. 2007) have used BACI designs to examine whether wind facilities modified raptor behavior, there is a scarcity of BACI data relating to North America grassland ecosystems that examine avian-wind energy relationships. There are less than a handful of studies in the entire United States, let alone the southern short grass prairie ecosystem, that incorporate preconstruction data to form the baseline for post-construction impact estimates (Johnson et al. 2000, Erickson et al. 2002). Although declines in grassland bird populations are well-documented (Peterjohn and Sauer 1999, Sauer et al. 2004), the causal mechanisms affecting the decline of grassland birds with increasing wind energy development in the southern short grass prairie are not well-understood (Kuvlesky et al. 2007, Maybe and Paul 2007). Several factors may potentially affect the bird population when wind turbines are constructed in areas with high bird densities (de Lucas et al. 2007). Habitat fragmentation, noise from turbines, physical movement of turbine blades, and increased vehicle traffic have been suggested as causes of decreased density of nesting grassland birds in Minnesota (Leddy et al. 1999), Oklahoma (O’Connell and Piorkowski 2006), and South Dakota (Shaffer and Johnson 2008). Similarly, constructing turbines in areas where bird flight patterns place them at similar heights of turbine blades increases the potential for bird collisions (Johnson et al. 2000, Hoover 2002). Raptor fatalities have been associated with topographic features such as ridges, saddles and rims where birds use updrafts from prevailing winds (Erickson et al. 2000, Johnson et al. 2000, Barrios and Rodriquez 2004, Hoover and Morrison 2005). Thus, wind energy development can result in indirect (e.g., habitat avoidance, decreased nest success) and direct (e.g., collision fatalities) impacts to bird populations (Anderson et al. 1999). Directly quantifying the level of potential impacts (e.g., estimated fatalities/mega-watthour) from wind energy development is beyond the scope of this study. Instead, I aim to quantify density, occupancy and flight behavior for the two bird groups mentioned earlier: obligate grassland songbirds and raptors, respectively, predict where impacts may occur, and provide management recommendations to minimize potential impacts. The United States Department of Energy (DOE), through the Office of Energy Efficiency and Renewable Energy Allocation, contracted Texas Tech University to investigate grassland bird patterns of occurrence in the anticipated CREZ in support of DOE’s 20% Wind Energy by 2030 initiative. In cooperation with Iberdrola Renewables, Inc., studies initiated by Wulff (2010) at Texas Tech University were continued at an area proposed for wind energy development and a separate reference site unassociated with wind energy development. I focused on four primary objectives and this thesis is accordingly organized in four separate chapters that address grassland bird density, grassland bird occupancy, raptor flight patterns, and finally I summarize species diversity and composition. The following chapters use formatting from the Journal of Wildlife Management guidelines (Block et al. 2011) with modifications as required by the Texas Tech University Graduate School. 1) I estimate pre-construction bird density patterns using methods that adjust for imperfect detection. I used a distance sampling protocol that effectively accounts for incomplete detection in the field where birds are present but not detected (Buckland et al. 2001). I improved density estimates with hierarchical distance sampling models, a modeling technique that effectively incorporates the detection process with environmental covariates that further influence bird density (Royle et al. 2004, Royle and Dorazio 2008). Covariates included road density and current oil and gas infrastructure to determine the relationship between existing energy development and bird density patterns. Further, I used remote sensing techniques and vegetation field data to investigate how landcover characteristics influenced bird density patterns. I focused species-specific analyses on obligate grassland birds with >70 detections per season namely grasshopper sparrow (Ammodramus savannarum) and horned lark (Eremophila alpestris). Chapter II focuses on hierarchical models that model and describe relationships between grassland bird density and anthropogenic and landscape features. 2) A large number of bird detections (>70) are needed to estimate density using distance sampling and collection of such quantity are often not feasible, particularly for cryptic species or species that naturally occur at low densities (Buckland et al. 2001). Occupancy models operate with far fewer data and are often used as a surrogate for bird abundance when there are fewer detections (MacKenzie and Nichols 2004). I used occupancy models that allow for the possibility of imperfect detection and species abundance to improve estimates of occurrence probability (Royal 2004). I focused species-specific analyses on grassland birds with few detections: Cassin’s sparrow (Peucaea cassinii), eastern meadowlark (Sturnella magna), and upland sandpiper (Bartramia longicauda). Chapter III uses a multi-season dynamic site occupancy model that incorporates bird abundance to better estimate occurrence probability. 3) When I considered the topographic relief of the study sites, the proposed design of the wind facility and its location within the central U.S. migratory corridor, I expanded the study to investigate raptor abundance and flight behavior (Hoover 2002, Miller 2008). I developed a new survey technique that improved the accuracy of raptor flight height estimates and compared seasonal counts and flight heights at the plateau rim and areas further inland. I used counts and flight behaviors to calculate species-specific collision risk indices for raptors based on topographic features. I focused species-specific analyses on raptors with the highest counts: American kestrel (Falco sparverius), northern harrier (Circus cyaneus), red-tailed hawk (Buteo jamaicensis), Swainson’s hawk (Buteo swainsoni), and turkey vulture (Cathartes aura). Chapter IV describes patterns of seasonal raptor abundance and flight behavior and how topography modulates collision risk with proposed wind energy turbines. 4) Finally, for completeness, in Chapter V I summarize morning point count data for all species and provide estimates of relative composition and species diversity with the Shannon-Wiener Diversity Index (Shannon and Weaver 1949).

17 WIND ENERGY↗

International Internships in Nuclear Safeguards and Security: Challenges and Successes

All students in the Russian safeguards and security degree programs at the National Research Nuclear University MEPhI and Tomsk Polytechnic University, sponsored by the Material Protection, Control and Accounting (MPC&A) Education Project, take part in a domestic internship at a Russian enterprise or facility. In addition, a select few students are placed in an international internship. These internships provide students with a better view of how MPC&A and nonproliferation in general are addressed outside of Russia. The possibility of an international internship is a significant incentive for students to enroll in the safeguards and security degree programs. The U.S. members of the MPC&A Education Project team interview students who have been nominated by their professors. These students must have initiative and reasonable English skills. The project team and professors then select students to be tentatively placed in various international internships during the summer or fall of their final year of study. Final arrangements are then made with the host organizations. This paper describes the benefits of the joint United States/Russia cooperation for next-generation workforce development, some of the international internships that have been carried out, the benefits of these international internships, and lessons learned in implementing them.

education↗

Building Toward a Small Wind Turbine Site Assessor Credential (Presentation)

Proper site assessment is integral to the development of a successful small wind project. Without a small wind site assessor certification program, consumers, including state incentive program managers, lack a benchmark for differentiating between qualified and nonqualified site assessors. A small wind site assessor best practice manual is being developed as a resource for consumers until a credential program becomes available. This presentation describes the purpose, proposed content, and the National Renewable Energy Laboratory's approach to the development of such a manual.

17 WIND ENERGY↗

SunShot Identity Video

Highlights of the SunShot program, the national targets for the program, and the "all of the above" approach to achieving those goals through research, tech transfer, permitting, tax incentives, and a comprehensive approach to installation.

14 SOLAR ENERGY↗

EERE's State & Local Energy Data Tool

EERE's State and Local Energy Data (SLED) Tool provides basic energy market information that can help state and local governments plan and implement clean energy projects, including electricity generation; fuel sources and costs; applicable policies, regulations, and financial incentives; and renewable energy resource potential. Watch this video to learn more about the tool and hear testimonials from real users about the benefits of using this tool.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Agent-Based Modleing of Power Plants Placement to Evaluate the Clean Energy Standard Goal

There is a political push for utilities to supply a specified share of their electricity sales from clean energy resources under the clean energy standard (CES). The goal is to achieve 80% clean energy by 2035. However, there are uncertainties about the ability of the utility industry to ramp up quickly even with the incentives that will be provided. Water availability from the streams is one of the major factors. The contiguous United States is divided into eighteen water regions, and multiple states share water from a single water region. Consequently, water usage decisions made in one state (located upstream of a water region that crosses multiple states) will greatly impact what is available downstream in another state. In this paper, an agent-based modeling approach is proposed to evaluate the clean energy standard goal for water-dependent energy resources. Specifically, using a water region rather than a state boundary as a bounding envelope for the modeling and starting at the headwaters, virtual power plants are placed based on the conditions that there is: (i) suitable land to site a particular power plant, (ii) enough water that meet regulatory guidelines within 20 miles of the suitable land, and (iii) a 20-mile buffer zone from an existing or a virtual power plant. The results obtained are discussed in the context of the proposed clean energy standard goal for states that overlap with one water region.

agent-based modeling↗

Islip Housing Authority Energy Efficiency Turnover Protocols, Islip, New York (Fact Sheet)

More than 1 million HUD-supported public housing units provide rental housing for eligible low-income families across the country. A survey of over 100 PHAs across the country indicated that there is a high level of interest in developing low cost solutions that improve energy efficiency and can be seamlessly included in the refurbishment process. Further, PHAs, have incentives (both internal and external) to reduce utility bills. ARIES worked with two public housing authorities (PHAs) to develop packages of energy efficiency retrofit measures the PHAs can cost effectively implement with their own staffs in the normal course of housing operations at the time when units are refurbished between occupancies. The energy efficiency turnover protocols emphasized air infiltration reduction, duct sealing and measures that improve equipment efficiency. ARIES documented implementation in ten housing units. Reductions in average air leakage were 16-20% and duct leakage reductions averaged 38%. Total source energy consumption savings was estimated at 6-10% based on BEopt modeling with a simple payback of 1.7 to 2.2 years. Implementation challenges were encountered mainly related to required operational changes and budgetary constraints. Nevertheless, simple measures can feasibly be accomplished by PHA staff at low or no cost. At typical housing unit turnover rates, these measures could impact hundreds of thousands of unit per year nationally.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Need for Systematic Retrofit Analysis in Multifamily Buildings

Multifamily housing offers high potential for energy savings through retrofits. A comprehensive energy audit with systematic evaluation of alternative energy measures is one of the key steps to realizing the full energy savings potential. However, this potential often remains unrealized when the selection of measures is (1) based on a one-size-fits-all approach originating from accustomed practices, (2) intended merely to meet code-compliance requirements, and/or (3) influenced by owner renter split incentive. In such cases, the benefits of comprehensive energy auditing are disregarded in view of the apparent difficulty in diagnosing multifamily buildings, evaluating alternative measures, and installing customized sets of measures. This paper highlights some of the barriers encountered in a multifamily housing retrofit project in Georgia and demonstrates the merits of systematic retrofit analysis by identifying opportunities for higher energy savings and improved comfort and indoor air quality that were missed in this project. The study uses a whole-building energy analysis conducted for a 10-unit, low-rise, multifamily building of a 110-unit apartment complex. The analysis projected a 24% energy savings from the measures installed in the building with a payback period of 10 years. Further analysis with a systematic evaluation of alternative measures showed that without compromising on the objectives of durability, livability, and appearance of the building, energy savings of up to 34% were achievable with a payback period of 7 years. The paper concludes by outlining recommendations that may benefit future retrofit projects by improving the audit process, streamlining tasks, and achieving higher energy savings.

Malhotra, Mini↗

ISO 50001 for Commercial Buildings: Lessons Learned From U.S. DOE Pilot Project: Preprint

In the U.S., the ISO 50001 Standard, which establishes energy management systems (EnMSs) and processes, has shown uptake primarily in the industrial sector. The U.S. Department of Energy (DOE) undertook a pilot program to explore ISO 50001 implementation in commercial buildings. Eight organizations participated as pilots, with technical assistance provided by DOE, the National Renewable Energy Laboratory (NREL), the Lawrence Berkeley National Laboratory (LBNL), and the Georgia Institute of Technology (Georgia Tech). This paper shares important lessons learned from the pilot. Staff time was the most critical resource required to establish effective EnMSs in commercial buildings. The pilot also revealed that technical support and template/example materials were essential inputs. Crucial activities included evaluating performance, identifying goals, making connections, communicating operational controls, and tracking/reviewing progress. Benefits realized included enhanced intra-organizational connections, greater energy awareness, increased process efficiencies, and improved ability to make business cases. Incremental benefits for ISO 50001 certification were greater accountability, assurance of best practices, public relations opportunities, and potential to unlock verified savings credits or incentive money. Incremental certification costs included more staff/consultant time, money for certification, and a tendency to limit EnMS scope in order to ensure favorable audit results. Five best practices were identified - utilizing expert technical assistance, training, and other resources; focusing on implementation over documentation; keeping top management involved; considering organizational structure when selecting EnMS scope; and matching the implementation level to an EnMS's scope and scale. The last two practices are particularly relevant to the commercial buildings sector.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Fleet DNA (Presentation)

The Fleet DNA project objectives include capturing and quantifying drive cycle and technology variation for the multitude of medium- and heavy-duty vocations; providing a common data storage warehouse for medium- and heavy-duty vehicle fleet data across DOE activities and laboratories; and integrating existing DOE tools, models, and analyses to provide data-driven decision making capabilities. Fleet DNA advantages include: for Government - providing in-use data for standard drive cycle development, R&D, tech targets, and rule making; for OEMs - real-world usage datasets provide concrete examples of customer use profiles; for fleets - vocational datasets help illustrate how to maximize return on technology investments; for Funding Agencies - ways are revealed to optimize the impact of financial incentive offers; and for researchers -a data source is provided for modeling and simulation.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Wind Technology Modeling Within the System Advisor Model (SAM) (Poster)

This poster provides detail for implementation and the underlying methodology for modeling wind power generation performance in the National Renewable Energy Laboratory's (NREL's) System Advisor Model (SAM). SAM's wind power model allows users to assess projects involving one or more large or small wind turbines with any of the detailed options for residential, commercial, or utility financing. The model requires information about the wind resource, wind turbine specifications, wind farm layout (if applicable), and costs, and provides analysis to compare the absolute or relative impact of these inputs. SAM is a system performance and economic model designed to facilitate analysis and decision-making for project developers, financers, policymakers, and energy researchers. The user pairs a generation technology with a financing option (residential, commercial, or utility) to calculate the cost of energy over the multi-year project period. Specifically, SAM calculates the value of projects which buy and sell power at retail rates for residential and commercial systems, and also for larger-scale projects which operate through a power purchase agreement (PPA) with a utility. The financial model captures complex financing and rate structures, taxes, and incentives.

17 WIND ENERGY↗

Comparison of Software Models for Energy Savings from Cool Roofs

A web-based Roof Savings Calculator (RSC) has been deployed for the United States Department of Energy as an industry-consensus tool to help building owners, manufacturers, distributors, contractors and researchers easily run complex roof and attic simulations. This tool employs modern web technologies, usability design, and national average defaults as an interface to annual simulations of hour-by-hour, whole-building performance using the world-class simulation tools DOE-2.1E and AtticSim in order to provide estimated annual energy and cost savings. In addition to cool reflective roofs, RSC simulates multiple roof and attic configurations including different roof slopes, above sheathing ventilation, radiant barriers, low-emittance roof surfaces, duct location, duct leakage rates, multiple substrate types, and insulation levels. A base case and energy-efficient alternative can be compared side-by-side to estimate monthly energy. RSC was benchmarked against field data from demonstration homes in Ft. Irwin, California; while cooling savings were similar, heating penalty varied significantly across different simulation engines. RSC results reduce cool roofing cost-effectiveness thus mitigating expected economic incentives for this countermeasure to the urban heat island effect. This paper consolidates comparison of RSC s projected energy savings to other simulation engines including DOE-2.1E, AtticSim, Micropas, and EnergyPlus, and presents preliminary analyses. RSC s algorithms for capturing radiant heat transfer and duct interaction in the attic assembly are considered major contributing factors to increased cooling savings and heating penalties. Comparison to previous simulation-based studies, analysis on the force multiplier of RSC cooling savings and heating penalties, the role of radiative heat exchange in an attic assembly, and changes made for increased accuracy of the duct model are included.

New, Joshua Ryan↗

An International Survey of Electric Storage Tank Water Heater Efficiency and Standards

Water heating is a main consumer of energy in households, especially in temperate and cold climates. In South Africa, where hot water is typically provided by electric resistance storage tank water heaters (geysers), water heating energy consumption exceeds cooking, refrigeration, and lighting to be the most consumptive single electric appliance in the home. A recent analysis for the Department of Trade and Industry (DTI) performed by the authors estimated that standing losses from electric geysers contributed over 1,000 kWh to the annual electricity bill for South African households that used them. In order to reduce this burden, the South African government is currently pursuing a programme of Energy Efficiency Standards and Labelling (EES&L) for electric appliances, including geysers. In addition, Eskom has a history of promoting heat pump water heaters (HPWH) through incentive programs, which can further reduce energy consumption. This paper provides a survey of international electric storage water heater test procedures and efficiency metrics which can serve as a reference for comparison with proposed geyser standards and ratings in South Africa. Additionally it provides a sample of efficiency technologies employed to improve the efficiency of electric storage water heaters, and outlines programs to promote adoption of improved efficiency. Finally, it surveys current programs used to promote HPWH and considers the potential for this technology to address peak demand more effectively than reduction of standby losses alone

29 ENERGY PLANNING, POLICY, AND ECONOMY↗