Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Image Transforms”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,405 records · Page 78

Large TV display system

A relatively small and low cost system is provided for projecting a large and bright television image onto a screen. A miniature liquid crystal array is driven by video circuitry to produce a pattern of transparencies in the array corresponding to a television image. Light is directed against the rear surface of the array to illuminate it, while a projection lens lies in front of the array to project the image of the array onto a large screen. Grid lines in the liquid crystal array are eliminated by a spacial filter which comprises a negative of the Fourier transform of the grid.

Liu, Hua-Kuang↗

Large area projection liquid-crystal video display system with inherent grid pattern optically removed

A relatively small and low-cost system is provided for projecting a large and bright television image onto a screen. A miniature liquid crystal array is driven by video circuitry to produce a pattern of transparencies in the array corresponding to a television image. Light is directed against the rear surface of the array to illuminate it, while a projection lens lies in front of the array to project the image of the array onto a large screen. Grid lines in the liquid crystal array are eliminated by a spacial filter which comprises a negative of the Fourier transform of the grid.

Liu, Hua-Kuang↗

Virtual Sensors Determined Through Machine Learning

We propose a method that increases the capability of a conventional sensor/instrument, transforming it into an enhanced virtual sensor/instrument. This paper focuses on a virtual thermal IR sensor based on a conventional visual (RGB) sensor. The estimation of thermal IR images can enhance the ability of terrain classification, which is crucial for autonomous navigation of rovers. The estimate in IR from visual band has inherent limitations, as these are different bands, yet correlations between visual/RGB and thermal IR images exist, as different terrains, which visually may appear different, also have different thermal inertia. We developed a deep learning-based algorithm that estimates thermal IR images from RGB images of terrains, providing the feasibility of the idea with average 1.21 error [degree].

Kurazume, Ryo↗

Collimated phase measuring deflectometry II: Re-design of the optical layout for high-curvature surfaces

Collimated phase measuring deflectometry (CPMD) is an optical metrology technique developed to improve upon traditional phase measuring deflectometry (PMD). CPMD utilizes telecentric imaging and collimated structured light illumination to eliminate the height-slope ambiguity present in traditional PMD measurements. After the publication of the first CPMD paper, efforts began to optimize the optical layout of the CPMD system. The first proposed change, and the one detailed in this work, was to move the Fourier transform (FT) lens closer to the surface under test (SUT). Moving the FT lens closer to the SUT meant that for a given FT lens diameter, a larger range of surface slopes on the SUT could be measured. This change to the optical layout was not trivial and introduced at least two concerns that had to be addressed: telecentricity in the imaging path and possible ghost reflections from the re-located FT lens. Here, in this work, we examine how these concerns were addressed and present results showing that the revised optical layout is capable of measurement results at least as good as the original CPMD optical layout. We also demonstrate the increased slope measuring range of the revised optical layout.

47 OTHER INSTRUMENTATION↗

Quantitative phase imaging by gradient retardance optical microscopy

Abstract Quantitative phase imaging (QPI) has become a vital tool in bioimaging, offering precise measurements of wavefront distortion and, thus, of key cellular metabolism metrics, such as dry mass and density. However, only a few QPI applications have been demonstrated in optically thick specimens, where scattering increases background and reduces contrast. Building upon the concept of structured illumination interferometry, we introduce Gradient Retardance Optical Microscopy (GROM) for QPI of both thin and thick samples. GROM transforms any standard Differential Interference Contrast (DIC) microscope into a QPI platform by incorporating a liquid crystal retarder into the illumination path, enabling independent phase-shifting of the DIC microscope's sheared beams. GROM greatly simplifies related configurations, reduces costs, and eradicates energy losses in parallel imaging modalities, such as fluorescence. We successfully tested GROM on a diverse range of specimens, from microbes and red blood cells to optically thick (~ 300 μm) plant roots without fixation or clearing.

47 OTHER INSTRUMENTATION↗

Delivering Robust Proton-Only Sensing of Hyperpolarized [1,2- 13 C 2 ]-Pyruvate Using Broad-Spectral-Range Nuclear Magnetic Resonance Pulse Sequences

Hyperpolarized [1- 13 C]pyruvate is the leading hyperpolarized injectable contrast agent and is currently under evaluation in clinical trials for molecular imaging of metabolic diseases, including cardiovascular disease and cancer. One aspect limiting broad scalability of the technique is that hyperpolarized 13 C MRI requires specialized 13 C hardware and software that are not generally available on clinical MRI scanners, which employ proton-only detection. Here, we present an approach that uses pulse sequences to transfer 13 C hyperpolarization to methyl protons for detection of the 13 C– 13 C pyruvate singlet, employing proton-only excitation and detection only. The new pulse sequences are robust to the B 1 and B 0 magnetic field inhomogeneities. The work focuses on singlet-to-magnetization (S2M) and rotor-synchronized (R) pulses, both relying on trains of hard pulses with broad spectral width coverage designed to effectively transform hyperpolarized 13 C 2 -singlet hyperpolarization to 1 H polarization on the CH 3 group of [1,2- 13 C 2 ]pyruvate. Finally, this approach may enable a broader adoption of hyperpolarized MRI as a molecular imaging technique.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Photographic film image enhancement

A series of experiments were undertaken to assess the feasibility of defogging color film by the techniques of optical spatial filtering. A coherent optical processor was built using red, blue, and green laser light input and specially designed Fourier transformation lenses. An array of spatial filters was fabricated on black and white emulsion slides using the coherent optical processor. The technique was first applied to laboratory white light fogged film, and the results were successful. However, when the same technique was applied to some original Apollo X radiation fogged color negatives, the results showed no similar restoration. Examples of each experiment are presented and possible reasons for the lack of restoration in the Apollo films are discussed.

Horner, J. L.↗

Clementine High Resolution Camera Mosaicking Project: CL 6022; 80 deg S to 90 deg S Latitude, South Periapsis - Volume 22

This compact disk (CD) is part of the Clementine I high resolution (HiRes) camera lunar image mosaics developed by Malin Space Science Systems (MSSS). These mosaics were developed through calibration and semi-automated registration against the recently released geometrically and photometrically controlled Ultraviolet/Visible (UV/Vis) Basemap Mosaic, which is available through the PDS, as CD-ROM volumes CL_3001-3015. The HiRes mosaics are compiled from non-uniformity corrected, 750 nanometer ("D") filter high resolution observations from the HiRes imaging system onboard the Clementine Spacecraft. The geometric control is provided by the U.S. Geological Survey (USGS) Clementine Basemap Mosaic compiled from the 750 nm Ultraviolet/Visible Clementine imaging system. Calibration was achieved by removing the image nonuniformity largely caused by the HiRes system's light intensifier. Also provided are offset and scale factors, achieved by a fit of the HiRes data to the corresponding photometrically calibrated UV/Vis basemap that approximately transform the 8-bit HiRes data to photometric units. The mosaics on this CD are compiled from polar data (latitudes greater than 80 degrees), and are presented in the stereographic projection at a scale of 30 m/pixel at the pole, a resolution 5 times greater than that (150 m/pixel) of the corresponding UV/Vis polar basemap. This 5:1 scale ratio is in keeping with the sub-polar mosaic, in which the HiRes and UV/Vis mosaics had scales of 20 m/pixel and 100 m/pixel, respectively. The equal-area property of the stereographic projection made this preferable for the HiRes polar mosaic rather than the basemap's orthographic projection. Thus, a necessary first step in constructing the mosaic was the reprojection of the UV/Vis basemap to the stereographic projection. The HiRes polar data can be naturally grouped according to the orbital periapsis, which was in the south during the first half of the mapping mission and in the north during the second half. Images in each group have generally uniform intrinsic resolution, illumination, exposure and gain. Rather than mingle data from the two periapsis epochs, separate mosaics are provided for each, a total of 4 polar mosaics. The mosaics are divided into 100 square tiles of 2250 pixels (approximately 2.2 deg near the pole) on a side. Not all squares of this grid contain HiRes mosaic data, some inevitably since a square is not a perfect representation of a (latitude) circle, others due to the lack of HiRes data. This CD also contains ancillary data files that support the HiRes mosaic. These files include browse images with UV/Vis context stored in a Joint Photographic Experts Group (JPEG) format, index files ('imgindx.tab' and 'srcindx.tab') that tabulate the contents of the CD, and documentation files. For more information on the contents and organization of the CD volume set refer to the "FILES, DIRECTORIES AND DISK CONTENTS" section of this document. The image files are organized according to NASA's Planetary Data System (PDS) standards. An image file (tile) is organized as a PDS labeled file containing an "image object".

Malin, Michael↗

Clementine High Resolution Camera Mosaicking Project: CL 6020; 80 deg N to 90 deg N Latitude, South Periapsis - Volume 20

This compact disk (CD) is part of the Clementine I high resolution (HiRes) camera lunar image mosaics developed by Malin Space Science Systems (MSSS). These mosaics were developed through calibration and semi-automated registration against the recently released geometrically and photometrically controlled Ultraviolet/Visible (UV/Vis) Basemap Mosaic, which is available through the PDS, as CD-ROM volumes CL_3001-3015. The HiRes mosaics are compiled from non-uniformity corrected, 750 nanometer ("D") filter high resolution observations from the HiRes imaging system onboard the Clementine Spacecraft. The geometric control is provided by the U.S. Geological Survey (USGS) Clementine Basemap Mosaic compiled from the 750 nm Ultraviolet/Visible Clementine imaging system. Calibration was achieved by removing the image nonuniformity largely caused by the HiRes system's light intensifier. Also provided are offset and scale factors, achieved by a fit of the HiRes data to the corresponding photometrically calibrated UV/Vis basemap that approximately transform the 8-bit HiRes data to photometric units. The mosaics on this CD are compiled from polar data (latitudes greater than 80 degrees), and are presented in the stereographic projection at a scale of 30 m/pixel at the pole, a resolution 5 times greater than that (150 m/pixel) of the corresponding UV/Vis polar basemap. This 5:1 scale ratio is in keeping with the sub-polar mosaic, in which the HiRes and UV/Vis mosaics had scales of 20 m/pixel and 100 m/pixel, respectively. The equal-area property of the stereographic projection made this preferable for the HiRes polar mosaic rather than the basemap's orthographic projection. Thus, a necessary first step in constructing the mosaic was the reprojection of the UV/Vis basemap to the stereographic projection. The HiRes polar data can be naturally grouped according to the orbital periapsis, which was in the south during the first half of the mapping mission and in the north during the second half. Images in each group have generally uniform intrinsic resolution, illumination, exposure and gain. Rather than mingle data from the two periapsis epochs, separate mosaics are provided for each, a total of 4 polar mosaics. The mosaics are divided into 100 square tiles of 2250 pixels (approximately 2.2 deg near the pole) on a side. Not all squares of this grid contain HiRes mosaic data, some inevitably since a square is not a perfect representation of a (latitude) circle, others due to the lack of HiRes data. This CD also contains ancillary data files that support the HiRes mosaic. These files include browse images with UV/Vis context stored in a Joint Photographic Experts Group (JPEG) format, index files ('imgindx.tab' and 'srcindx.tab') that tabulate the contents of the CD, and documentation files. For more information on the contents and organization of the CD volume set refer to the "FILES, DIRECTORIES AND DISK CONTENTS" section of this document. The image files are organized according to NASA's Planetary Data System (PDS) standards. An image file (tile) is organized as a PDS labeled file containing an "image object".

Malin, Michael↗

Clementine High Resolution Camera Mosaicking Project: CL 6021; 80 deg S to 90 deg S Latitude, North Periapsis - Volume 21

This compact disk (CD) is part of the Clementine I high resolution (HiRes) camera lunar image mosaics developed by Malin Space Science Systems (MSSS). These mosaics were developed through calibration and semi-automated registration against the recently released geometrically and photometrically controlled Ultraviolet/Visible (UV/Vis) Basemap Mosaic, which is available through the PDS, as CD-ROM volumes CL_3001-3015. The HiRes mosaics are compiled from non-uniformity corrected, 750 nanometer ("D") filter high resolution observations from the HiRes imaging system onboard the Clementine Spacecraft. The geometric control is provided by the U. S. Geological Survey (USGS) Clementine Basemap Mosaic compiled from the 750 nm Ultraviolet/Visible Clementine imaging system. Calibration was achieved by removing the image nonuniformity largely caused by the HiRes system's light intensifier. Also provided are offset and scale factors, achieved by a fit of the HiRes data to the corresponding photometrically calibrated UV/Vis basemap that approximately transform the 8-bit HiRes data to photometric units. The mosaics on this CD are compiled from polar data (latitudes greater than 80 degrees), and are presented in the stereographic projection at a scale of 30 m/pixel at the pole, a resolution 5 times greater than that (150 m/pixel) of the corresponding UV/Vis polar basemap. This 5:1 scale ratio is in keeping with the sub-polar mosaic, in which the HiRes and UV/Vis mosaics had scales of 20 m/pixel and 100 m/pixel, respectively. The equal-area property of the stereographic projection made this preferable for the HiRes polar mosaic rather than the basemap's orthographic projection. Thus, a necessary first step in constructing the mosaic was the reprojection of the UV/Vis basemap to the stereographic projection. The HiRes polar data can be naturally grouped according to the orbital periapsis, which was in the south during the first half of the mapping mission and in the north during the second half. Images in each group have generally uniform intrinsic resolution, illumination, exposure and gain. Rather than mingle data from the two periapsis epochs, separate mosaics are provided for each, a total of 4 polar mosaics. The mosaics are divided into 100 square tiles of 2250 pixels (approximately 2.2 deg near the pole) on a side. Not all squares of this grid contain HiRes mosaic data, some inevitably since a square is not a perfect representation of a (latitude) circle, others due to the lack of HiRes data. This CD also contains ancillary data files that support the HiRes mosaic. These files include browse images with UV/Vis context stored in a Joint Photographic Experts Group (JPEG) format, index files ('imgindx.tab' and 'srcindx.tab') that tabulate the contents of the CD, and documentation files. For more information on the contents and organization of the CD volume set refer to the "FILES, DIRECTORIES AND DISK CONTENTS" section of this document. The image files are organized according to NASA's Planetary Data System (PDS) standards. An image file (tile) is organized as a PDS labeled file containing an "image object".

Malin, Michael↗

Clementine High Resolution Camera Mosaicking Project: CL 6019; 80 deg N to 90 deg N Latitude, North Periapsis - Volume 19

This compact disk (CD) is part of the Clementine I high resolution (HiRes) camera lunar image mosaics developed by Malin Space Science Systems (MSSS). These mosaics were developed through calibration and semi-automated registration against the recently released geometrically and photometrically controlled Ultraviolet/Visible (UV/Vis) Basemap Mosaic, which is available through the PDS, as CD-ROM volumes CL_3001-3015. The HiRes mosaics are compiled from non-uniformity corrected, 750 nanometer ("D") filter high resolution observations from the HiRes imaging system onboard the Clementine Spacecraft. The geometric control is provided by the U. S. Geological Survey (USGS) Clementine Basemap Mosaic compiled from the 750 nm Ultraviolet/Visible Clementine imaging system. Calibration was achieved by removing the image nonuniformity largely caused by the HiRes system's light intensifier. Also provided are offset and scale factors, achieved by a fit of the HiRes data to the corresponding photometrically calibrated UV/Vis basemap that approximately transform the 8-bit HiRes data to photometric units. The mosaics on this CD are compiled from polar data (latitudes greater than 80 degrees), and are presented in the stereographic projection at a scale of 30 m/pixel at the pole, a resolution 5 times greater than that (150 m/pixel) of the corresponding UV/Vis polar basemap. This 5:1 scale ratio is in keeping with the sub-polar mosaic, in which the HiRes and UV/Vis mosaics had scales of 20 m/pixel and 100 m/pixel, respectively. The equal-area property of the stereographic projection made this preferable for the HiRes polar mosaic rather than the basemap's orthographic projection. Thus, a necessary first step in constructing the mosaic was the reprojection of the UV/Vis basemap to the stereographic projection. The HiRes polar data can be naturally grouped according to the orbital periapsis, which was in the south during the first half of the mapping mission and in the north during the second half. Images in each group have generally uniform intrinsic resolution, illumination, exposure and gain. Rather than mingle data from the two periapsis epochs, separate mosaics are provided for each, a total of 4 polar mosaics. The mosaics are divided into 100 square tiles of 2250 pixels (approximately 2.2 deg near the pole) on a side. Not all squares of this grid contain HiRes mosaic data, some inevitably since a square is not a perfect representation of a (latitude) circle, others due to the lack of HiRes data. This CD also contains ancillary data files that support the HiRes mosaic. These files include browse images with UV/Vis context stored in a Joint Photographic Experts Group (JPEG) format, index files ('imgindx.tab' and 'srcindx.tab') that tabulate the contents of the CD, and documentation files. For more information on the contents and organization of the CD volume set refer to the "FILES, DIRECTORIES AND DISK CONTENTS" section of this document. The image files are organized according to NASA's Planetary Data System (PDS) standards. An image file (tile) is organized as a PDS labeled file containing an "image object".

Malin, Michael↗

Enhanced visible-light-driven photocatalytic activities of Bi2Fe4O9/g-C3N4 composite photocatalysts

Highlights: • The novel Bi{sub 2}Fe{sub 4}O{sub 9}/g-C{sub 3}N{sub 4} composite photocatalysts have been designed and prepared. • Combination of Bi{sub 2}Fe{sub 4}O{sub 9} and g-C{sub 3}N{sub 4} could enhance the visible-light-driven photocatalytic degradation for RhB. • The effects of Bi{sub 2}Fe{sub 4}O{sub 9}/g-C{sub 3}N{sub 4} weight ratios on photocatalytic performance in the composite have been discussed. • The Z-scheme photocatalytic mechanism was proposed and discussed in detail. - Abstract: A series of Bi{sub 2}Fe{sub 4}O{sub 9}/g-C{sub 3}N{sub 4} composite photocatalysts are prepared via a facile mixing-calcination method. The crystal structures of composites are investigated by X-ray Diffraction (XRD) and Fourier Transform Infrared Spectroscopy (FT-IR). The Field Emission Scanning Electron Microscope (FE-SEM) in combination with Energy Dispersive X-ray Spectroscopy (EDS) mapping analysis and Transmission Electron Microcopy (TEM) images illustrate the uniform distribution of constituent elements and clear interface between Bi{sub 2}Fe{sub 4}O{sub 9} and g-C{sub 3}N{sub 4} component. The visible-light-driven photocatalytic rates of Rhodamine B over Bi{sub 2}Fe{sub 4}O{sub 9}/g-C{sub 3}N{sub 4} composites increase and then decrease with the increase of g-C{sub 3}N{sub 4} content. The effects of Bi{sub 2}Fe{sub 4}O{sub 9}/g-C{sub 3}N{sub 4} weight ratios on photocatalytic performance are thoroughly discussed. Meanwhile, the active species trapping experiments and the electrochemical impedance spectra as well as the electronic energy-band structure estimation analysis demonstrate that the photocatalytic mechanism for Bi{sub 2}Fe{sub 4}O{sub 9}/g-C{sub 3}N{sub 4} composites is ascribed to the Z-scheme. In addition, the recyclability and stability experiments of the composite are also studied.

36 MATERIALS SCIENCE↗

In-situ visualizing atomic structural evolution during crystallization in ternary Zr Cu Al bulk metallic glasses

A well-designed experimental method has been presented to in-situ visualize the amorphous-to-crystalline phase transformation of two glass formers at the atomic length scale in the supercooled liquid region using a high voltage electron microscopy (HVEM). Analysis of the HVEM high-resolution images, supported by the in situ synchrotron diffraction, further confirms previous observations of distinctively different crystallization pathways in the two Zr-Cu-Al alloys. Moreover, the HVEM results illustrate that isolated distributed nanocrystals with mutual orientation easily grew up from the Zr 56 Cu 36 Al 8 , an average glass former, which follows a classical crystallization pathway; while density population poorly ordered atomic clusters with large misorientation suspended the growth in the Zr 46 Cu 46 Al 8 , a good glass former, which might follow an unusual crystallization pathway. In addition, in-situ synchrotron diffraction measurements confirm that the Zr 56 Cu 36 Al 8 alloy finally crystallized into an extended structure, in contrast, the final crystalline product of Zr 46 Cu 46 Al 8 alloy possesses a damped structure. Our study provides a detailed microscopic understanding of the crystallization behaviors in the supercooled liquids, showing that the density population nucleation site with large misorientation and the confined final crystalline structure contribute to the stability of Zr-Cu-Al supercooled liquids.

36 MATERIALS SCIENCE↗

Active interlocking metasurfaces enabled by shape memory alloys

Interlocking metasurfaces (ILMs) are a newly developed joining technology that relies on arrays of interlocking features that transmit force and constrain motion between adjoining bodies in one or more directions. This study explores harnessing the shape memory effect (SME) in Nickel-Titanium shape memory alloys (NiTi SMAs) in structures fabricated using additive manufacturing (AM) to advance the development of active ILMs by creating unit cells that open or close at specific temperatures. The study encompasses designing and fabricating two distinct interlocking array configurations using near-equiatomic NiTi powder and the laser powder bed fusion (L-PBF) AM technique, following a previously developed AM process optimization framework to manufacture defect-free parts. To guide the design process, finite element analysis (FEA) was employed to predict strain values during engage-disengage cycles. The martensitic transformation characteristics of the ILMs were characterized. Thermomechanical testing revealed that the ILMs demonstrate high locking force once engaged, coupled with complete shape recovery and good cyclic stability. Digital image correlation (DIC) was also employed to validate the FEA predictions during the engage-disengage cycles. The results indicate that NiTi SMA-based ILMs can be designed and fabricated into complex shapes using L-PBF. By leveraging the SME, the functionality of an ILM can be improved upon. The combination of computational modeling, additive manufacturing, and thermomechanical and physical property characterization provides a framework for designing future ILMs out of active materials.

Additive manufacturing↗

Campanile Near-Field Probes Fabricated by Nanoimprint Lithography on the Facet of an Optical Fiber

One of the major challenges to the widespread adoption of plasmonic and nano-optical devices in real-life applications is the difficulty to mass-fabricate nano-optical antennas in parallel and reproducible fashion, and the capability to precisely place nanoantennas into devices with nanometer-scale precision. In this study, we present a solution to this challenge using the state-of-the-art ultraviolet nanoimprint lithography (UV-NIL) to fabricate functional optical transformers onto the core of an optical fiber in a single step, mimicking the 'campanile' near-field probes. Imprinted probes were fabricated using a custom-built imprinter tool with co-axial alignment capability with sub < 100 nm position accuracy, followed by a metallization step. Scanning electron micrographs confirm high imprint fidelity and precision with a thin residual layer to facilitate efficient optical coupling between the fiber and the imprinted optical transformer. The imprinted optical transformer probe was used in an actual NSOM measurement performing hyperspectral photoluminescence mapping of standard fluorescent beads. The calibration scans confirmed that imprinted probes enable sub-diffraction limited imaging with a spatial resolution consistent with the gap size. This novel nano-fabrication approach promises a low-cost, high-throughput, and reproducible manufacturing of advanced nano-optical devices.

36 MATERIALS SCIENCE↗

pyDiSCaMB : enabling the use of multipolar scattering factors in Phenix

Multipolar scattering models, such as the transferable aspherical atom model, account for atomic chemical interactions and provide a more accurate representation of experimental data. However, the simpler independent atom model (IAM), which assumes non-interacting atoms, is the only model available in the most widely used macromolecular refinement programs. This is primarily because IAM offers a hard-to-beat combination of computational efficiency and modelling power at typical macromolecular resolutions. By contrast, more accurate multipolar modelling has historically been limited due to its computational cost and the absence of an interface between software capable of calculating structure factors and gradients based on multipolar models and software designed for macromolecular refinement. This work introduces pyDiSCaMB , a Python software package designed to integrate between the computational crystallography toolbox ( cctbx ) and the quantum crystallography library DiSCaMB ( Densities in Structural Chemistry and Molecular Biology ), thus enabling multipolar scattering models in Phenix 's toolkit. The implementation, features and capabilities of pyDiSCaMB are presented, the runtimes for the calculation of structure factor and target gradients with respect to atomic parameters are explored, and Fourier images of electrostatic potential, electron density and deformation maps are computed as illustrative examples. The pyDiSCaMB library will make multipolar modelling widely available to the structural biology community, potentially transforming refinement and model-building for both crystallography and cryogenic electron microscopy (cryoEM).

MATTS data bank↗