Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “IONIZATION CHAMBER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,405 records · Page 78

Ion tracking in an electrostatic potential distribution

An ion tracking system utilizing a single detector was designed to resolve two dimensional potential distributions in a vacuum. The ion detector consisted of a continuous dynode electron multiplier tube mounted behind a series of aperture plates. The detector was located on a track below a wedge shaped structure used to produce the desired potential distribution. A 150 volt electron beam aimed at selected regions, ionized the residual gas in the chamber. The ions were ejected from their source points by electrostatic forces causing them to drift downward toward the detector. Measurements of particle energy, detector position, and entry angle of the incoming particle flux were used to initialize a computer trajectory-tracing program. The program assumes a known theoretically calculated potential distribution near the wedge for computation of particle trajectories, providing a basis for evaluating the data. Special attention was given to characterization of the ion detector.

Ross, D. P.↗

Dual ion beam deposition of carbon films with diamondlike properties

A single and dual ion beam system was used to generate amorphous carbon films with diamond like properties. A methane/argon mixture at a molar ratio of 0.28 was ionized in the low pressure discharge chamber of a 30-cm-diameter ion source. A second ion source, 8 cm in diameter was used to direct a beam of 600 eV Argon ions on the substrates (fused silica or silicon) while the deposition from the 30-cm ion source was taking place. Nuclear reaction and combustion analysis indicate H/C ratios for the films to be 1.00. This high value of H/C, it is felt, allowed the films to have good transmittance. The films were impervious to reagents which dissolve graphitic and polymeric carbon structures. Although the measured density of the films was approximately 1.8 gm/cu cm, a value lower than diamond, the films exhibited other properties that were relatively close to diamond. These films were compared with diamondlike films generated by sputtering a graphite target.

Mirtich, M. J.↗

Dual-ion-beam deposition of carbon films with diamond-like properties

A single and dual ion beam system was used to generate amorphous carbon films with diamond like properties. A methane/argon mixture at a molar ratio of 0.28 was ionized in the low pressure discharge chamber of a 30-cm-diameter ion source. A second ion source, 8 cm in diameter was used to direct a beam of 600 eV Argon ions on the substrates (fused silica or silicon) while the deposition from the 30-cm ion source was taking place. Nuclear reaction and combustion analysis indicate H/C ratios for the films to be 1.00. This high value of H/C, it is felt, allowed the films to have good transmittance. The films were impervious to reagents which dissolve graphitic and polymeric carbon structures. Although the measured density of the films was approximately 1.8 gm/cu cm, a value lower than diamond, the films exhibited other properties that were relatively close to diamond. These films were compared with diamond like films generated by sputtering a graphite target.

Mirtich, M. J.↗

Alpha-particle Gas Pressure Gauge

Described are preliminary results obtained on a novel gas pressure gauge that operates between 0.1 and 1000 mb. This gauge uses a 1- micron Ci alpha particle source to ionize the gas in a small chamber with an electric field imposed between anode and cathode electrodes that drives positive ions to the cathode where they are collected electronically. This gauge could make Martian pressure measurements.

gas pressure sensor micro-pressure gauge alpha-par↗

Methylation Pattern Detection in the Genome of Bacillus Pumilus Strain SAFR-032

Bacillus pumilus SAFR-032, an endospore-forming bacterial strain that was isolated from a spacecraft assembly facility (SAFR), was investigated to determine its methylation pattern (methylome) across the genome in comparison to the previously sequenced reference genome. In addition, a version of SAFR-032 that was flown as spores for 18 months on the International Space Station (ISS) was also investigated for possible genomic changes due to long-duration ISS-flight and to determine if methylation patterns may have changed. Both the genomics and methylomics were conducted using a Nanopore MinION sequencing device. In addition to the omics investigation, the two SAFR-032 strains, ISS flown and non-ISS flown, were compared phenotypically in chamber experiments testing individual environmental insults: ionizing radiation, UV exposure, and cold desiccation (i.e. freeze drying). Results from this study inform on Planetary Protection concerns and will reveal potential DNA damage associated with long-term spaceflight and how such damage may influence survivors after being transported to an extraterrestrial environment, such as Mars.

Serda, Bianca M.↗

Extreme Environment Hot Fire Durability of Post-Processed Additively Manufactured GRCop-Alloy Combustion Chambers in LOX/Hydrogen and LOX/Methane

Extreme environment survivability of metal additive manufactured (AM) GRCop-alloy thrust chambers has been demonstrated in different bi-propellants at near stoichiometric and even oxygen rich combustion. GRCop-alloy chambers tested at NASA Marshall Space Flight Center (MSFC) have accumulated over 26,000 seconds of hot fire duration and over 500 starts. These chambers are produced using an AM process called laser powder bed fusion (L-PBF). A major feature of this process is high wall surface roughness which can be customized in post processing to leverage various performance advantages. Post-processing can include heat treatment, final machining, polishing, and welding and is key to hardware survivability in extreme environments. Surface finish enhancement techniques were applied to the hot wall and coolant channels to reduce the overall total heat load to the chamber walls. Performance optimization of various thrust class TCA’s is a strategic technology goal of NASA MSFC. Three different chamber geometries using cryogenic methane and de-ionized water as coolants were hot fire tested to obtain their life cycle, pressure drop, and heat load performances. Several 1.2K lbf LOX/H2 chambers, 1K lbf LOX/CH4 chambers, and 7K lbf LOX/CH4 chambers were tested. All post-processed configurations performed remarkably well when subjected to extreme hot fire test conditions. Streaking and blanching due to localized oxygen rich conditions were observed on some test articles in their as-built surface finish state. However, this is actually a function of the injector mixing and only serves to further establish the durability of L-PBF GRCop-alloy thrust chambers. Several different polishing techniques were applied to the hot wall and integrated coolant channels prior to hot fire testing and their performances assessed. Overall, AM produced GRCop chambers are extremely reliable, durable, and customizable to the desired performance metrics.

grcop↗

Characterization of an Ionization Readout Tile for nEXO

Anewdesign for the anode of a time projection chamber, consisting of a charge-detecting "tile", is investigated for use in large scale liquid xenon detectors. The tile is produced by depositing 60 orthogonal metal charge-collecting strips, 3 mm wide, on a 10 cm 10 cm fused-silica wafer. These charge tiles may be employed by large detectors, such as the proposed tonne-scale nEXO experiment to search for neutrinoless double-beta decay. Modular by design, an array of tiles can cover a sizable area. The width of each strip is small compared to the size of the tile, so a Frisch grid is not required. A grid-less, tiled anode design is beneficial for an experiment such as nEXO, where a wire tensioning support structure and Frisch grid might contribute radioactive backgrounds and would have to be designed to accommodate cycling to cryogenic temperatures. The segmented anode also reduces some degeneracies in signal reconstruction that arise in large-area crossed-wire time projection chambers. A prototype tile was tested in a cell containing liquid xenon. Very good agreement is achieved between the measured ionization spectrum of a 207Bi source and simulations that include the microphysics of recombination in xenon and a detailed modeling of the electrostatic field of the detector. An energy resolution E=5.5% is observed at 570 keV, comparable to the best intrinsic ionization-only resolution reported in literature for liquid xenon at 936 V/cm.

Jewell, M J.↗

LArPix: demonstration of low-power 3D pixelated charge readout for liquid argon time projection chambers

In this work, we report the demonstration of a low-power pixelated readout system designed for three-dimensional ionization charge detection and digital readout of liquid argon time projection chambers (LArTPCs) . Unambiguous 3D charge readout was achieved using a custom-designed system-on-a-chip ASIC (LArPix) to uniquely instrument each pad in a pixelated array of charge-collection pads. The LArPix ASIC, manufactured in 180 nm bulk CMOS, provides 32 channels of charge-sensitive amplification with self-triggered digitization and multiplexed readout at temperatures from 80 K to 300 K . Using an 832-channel LArPix-based readout system with 3 mm spacing between pads, we demonstrated low-noise (0<50 e - RMS equivalent noise charge) and very low-power (<100 μW/channel) ionization signal detection and readout . The readout was used to successfully measure the three-dimensional ionization distributions of cosmic rays passing through a LArTPC, free from the ambiguities of existing projective techniques. The system design relies on standard printed circuit board manufacturing techniques, enabling scalable and low-cost production of large-area readout systems using common commercial facilities. This demonstration overcomes a critical technical obstacle for operation of LArTPCs in high-occupancy environments, such as the near detector site of the Deep Underground Neutrino Experiment (DUNE) .

47 OTHER INSTRUMENTATION↗

Aerosol ionizer

A system and method comprising an ion production chamber having an ultra-violet light source disposed towards said chamber, a coated quartz plate between the chamber and the UV source whose coating absorbs incident UV light and ejects electrons into the chamber through the photoelectric effect, a harvest gas disposed to flow through the chamber from an inlet to an outlet, and a jet operable to introduce a sample into the harvest gas flow. In some embodiments the system includes using helium as the harvest gas. Certain embodiments include introducing a sample perpendicular to the harvest gas flow and using multiple sample introduction jets to increase mixing efficiency. In some embodiments the harvest gas and particle sample jet are one and the same. The charge sample may be coupled to a MEMS-based electrometer.

36 MATERIALS SCIENCE↗

Aerosol ionizer

A system and method comprising an ion production chamber having an ultra-violet light source disposed towards said chamber, a coated quartz plate between the chamber and the UV source whose coating absorbs incident UV light and ejects electrons into the chamber through the photoelectric effect, a harvest gas disposed to flow through the chamber from an inlet to an outlet, and a jet operable to introduce a sample into the harvest gas flow. In some embodiments the system includes using helium as the harvest gas. Certain embodiments include introducing a sample perpendicular to the harvest gas flow and using multiple sample introduction jets to increase mixing efficiency. In some embodiments the harvest gas and particle sample jet are one and the same. The charge sample may be coupled to a MEMS-based electrometer.

Brechtel, Fredrick J.↗

Managing photon flux in a miniaturized photoionization detector

Miniaturized photoionization detectors (PIDs) are used in conjunction with gas chromatography systems to detect volatile compounds in gases by collecting the current from the photoionized gas analytes. PIDs should be inexpensive and compatible with a wide range of analyte species. One such PID is based on the formation of a He plasma in a dielectric barrier discharge (DBD), which generates vacuum UV (VUV) photons from excited states of He to photoionize gas analytes. There are several design parameters that can be leveraged to increase the ionizing photon flux to gas analytes to increase the sensitivity of the PID. To that end, the methods to maximize the photon flux from a pulsed He plasma in a DBD-PID were investigated using a two-dimensional plasma hydrodynamics model. The ionizing photon flux originated from the resonance states of helium, He(3P) and He(2 1 P), and from the dimer excimer He 2 *. While the photon flux from the resonant states was modulated over the voltage pulse, the photon flux from He 2 * persisted long after the voltage pulse passed. Several geometrical optimizations were investigated, such as using an array of pointed electrodes. However, increasing the capacitance of the dielectric enclosing the plasma chamber had the largest effect on increasing the VUV photon fluence to gas analytes.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Study on the Properties of Ionized Metal Plasma Methodology on Titanium

Ionized Metal Plasma (IMP) deposition was used in depositing metal interconnection of titanium metal film. Inductively coupled plasma (ICP) was attached to chamber wall where it creates an electromagnetic field, thus, ionizing the sputtered metal atoms from target. The film morphology was observed by scanning electron microscope (SEM). Acoustic measurement of titanium film thickness showed that there was a comparable result with film resistance measured by 4-point probe. Results show that higher plasma density would cause tensile properties on the film stress.

36 MATERIALS SCIENCE↗

Final Report on the Plasma Liner Compression Experiment

The Field Reversed Configuration (FRC) plasmoid’s stability, robustness, and self-organization have been demonstrated in many experiments employing a variety of formation methods over the last 50 years. A new formation method capable of remotely forming a hot, stable, and stationary FRC that can be further compressed to fusion conditions has been developed at MSNW. The formation method consists of the super-sonic merging of two FRCs, which are independently formed outside of the central compression chamber. Upon collision in the center of the compression chamber, the FRCs merge and become stationary, thereby thermalizing their translational kinetic energy. In the Plasma Liner Compression (PLC) experiment, the target FRC is positioned in a compression chamber where it is either magnetically compressed by the increasing flux from a theta-pinch coil, or by the theta-pinch implosion of a pre-formed plasma liner. The plasma liner is formed via an annular array of 32 axially directed MPD plasma sources near the vacuum chamber walls in the compression area. Xenon gas is ionized by the plasma sources, magnetized to the ~ 0.1 T bias field which keeps the Xenon liner confined to an annulus near the chamber wall. The FRC is ideally vacuum isolated from the Xenon plasma liner due to the bias field, which also acts as the guide field required for FRC merging. Close agreement is found between experimental results and 2D MHD numerical calculations. Efficient coupling (~ 50%) between the compression bank and the plasma liner has been observed. Flux and plasma liner compression of merged FRCs were tested. While the flux compression of the merged FRC resulted in a hot fusion plasma, the liner interaction with the FRC at this scale cooled the plasma.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Cesium control and diagnostics in surface plasma negative ion sources

For efficient and reliable negative ion generation it is very important to improve a cesium control and diagnostics. Laser beam attenuation and resonance fluorescence can be used for measurement of cesium distribution and cesium control. Resonant laser excitation and two-photon excitation can be used for improved cesium ionization and cesium trapping in the discharge chamber. Simple and inexpensive diode lasers can be used for cesium diagnostics and control. Cesium migration along the surface is an important mechanism of cesium escaping. It is important to develop a suppression of cesium migration and cesium accumulation on the extraction system.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Use of Chemi-Ionization to Calculate Temperature of Hydrocarbon Flame

In the present paper, we have experimentally studied the dependences of the maximum temperature of the hydrocarbon flame on the electron current (due to the flame chemi-ionization), the width of the turbulent combustion zone, and the amount and composition of the air-fuel mixture in the combustion chamber of variable volume. Based on the proposed formula, we have been also able to estimate the temperature and compare with its experimental value showing that the convergence has been more than 85% at an excess air factor value ranging from 0.8 to 1.15. The obtained results can be used to predict and monitor the maximum flame temperature in the combustion chamber of an internal combustion engine and other power plants by using the ionization probe.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Low-mass Dark Matter Search with the DarkSide-50 Experiment

We present the results of a search for dark matter WIMPs in the mass range below 20 GeV/c^2 using a target of low-radioactivity argon. The data were obtained using the DarkSide-50 apparatus at Laboratori Nazionali del Gran Sasso (LNGS). The analysis is based on the ionization signal, for which the DarkSide-50 time projection chamber is fully efficient at 0.1 keVee. The observed rate in the detector at 0.5 keVee is about 1.5 events/keVee/kg/day and is almost entirely accounted for by known background sources. We obtain a 90% C.L. exclusion limit above 1.8 GeV/c^2 for the spin-independent cross section of dark matter WIMPs on nucleons, extending the exclusion region for dark matter below previous limits in the range 1.8-6 GeV/c^2.

Agnes, P↗

Increased Upstream Ionization due to Formation of a Double Layer

We report observations that confirm a theoretical prediction that formation of a current-free double layer in a plasma expanding into a chamber of larger diameter is accompanied by an increase in ionization upstream of the double layer. The theoretical model argues that the increased ionization is needed to balance the difference in diffusive losses upstream and downstream of the expansion region. In our expanding helicon source experiments, we find that the upstream plasma density increases sharply at the same antenna frequency at which the double layer appears.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗