Real-time evaluation of cybersecurity threats to DER inverter grid-support functions

In this project we aim to contribute to the understanding of the type and severity of potential cybersecurity attacks to the grid-support functionalities of DER systems interconnected to the AC distribution grid via inverters. Our preliminary work focused on developing a small-scale testbed allowing to study cybersecurity threats to an isolated photovoltaic-battery system using a real-time simulator (Typhoon HIL602+) with a real DNP3 communication connection over TCP/IP, allowing for safe and efficient monitoring and manipulation of data traffic between the simulated hardware and supervisory control and data acquisition (SCADA) system. In this project we propose to expand upon this development by utilizing a) a recently acquired NovaCor RTDS (Real Rime digital Simulator) to emulate the DER-inverter-grid topology including main grid-support functions as defined by IEEE Std. 1547-2018, and b) an industrial control and automation device to enable realistic evaluation of control functions and utilization of communication protocols for real-time data transmission.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Navier-Stokes Simulation of Airconditioning Facility of a Large Modem Computer Room

NASA recently assembled one of the world's fastest operational supercomputers to meet the agency's new high performance computing needs. This large-scale system, named Columbia, consists of 20 interconnected SGI Altix 512-processor systems, for a total of 10,240 Intel Itanium-2 processors. High-fidelity CFD simulations were performed for the NASA Advanced Supercomputing (NAS) computer room at Ames Research Center. The purpose of the simulations was to assess the adequacy of the existing air handling and conditioning system and make recommendations for changes in the design of the system if needed. The simulations were performed with NASA's OVERFLOW-2 CFD code which utilizes overset structured grids. A new set of boundary conditions were developed and added to the flow solver for modeling the roomls air-conditioning and proper cooling of the equipment. Boundary condition parameters for the flow solver are based on cooler CFM (flow rate) ratings and some reasonable assumptions of flow and heat transfer data for the floor and central processing units (CPU) . The geometry modeling from blue prints and grid generation were handled by the NASA Ames software package Chimera Grid Tools (CGT). This geometric model was developed as a CGT-scripted template, which can be easily modified to accommodate any changes in shape and size of the room, locations and dimensions of the CPU racks, disk racks, coolers, power distribution units, and mass-storage system. The compute nodes are grouped in pairs of racks with an aisle in the middle. High-speed connection cables connect the racks with overhead cable trays. The cool air from the cooling units is pumped into the computer room from a sub-floor through perforated floor tiles. The CPU cooling fans draw cool air from the floor tiles, which run along the outside length of each rack, and eject warm air into the center isle between the racks. This warm air is eventually drawn into the cooling units located near the walls of the room. One major concern is that the hot air ejected to the middle isle might recirculate back into the cool rack side and cause thermal short-cycling. The simulations analyzed and addressed the following important elements of the computer room: 1) High-temperature build-up in certain regions of the room; 2) Areas of low air circulation in the room; 3) Potential short-cycling of the computer rack cooling system; 4) Effectiveness of the perforated cooling floor tiles; 5) Effect of changes in various aspects of the cooling units. Detailed flow visualization is performed to show temperature distribution, air-flow streamlines and velocities in the computer room.

Source record↗

Electric Access System Enhancement (EASE): Assessment of a Distributed Energy Resource Management System for Enabling Dynamic Hosting Capacity

The Electric Access System Enhancement (EASE) project demonstrated a scalable, interoperable, and cost-effective means of integrating high penetration of distributed energy resources (DERs). The control architecture developed leveraged a Distributed Energy Resource Management System, Distribution System Operator for transacting energy, and 3rd Party DER Aggregator platform. The project identified ways to enhance the customer interconnection process to the grid and improve access to information from DERs and optimize the usage of DERs to provide energy services in a simulated day-ahead shadow market while maintain grid reliability. By integrating these capabilities into a scalable system of systems, the DSO can effectively balance DER generation and customer demand on the distribution network. This capability allows the grid to host more DER than traditionally possible on wires alone. Hosting more DER has the added benefit of supplying increased demand growth, sometimes beyond the capacity limits of the distribution network itself. This is known as a dynamic hosting capacity, which could help utilities manage the forecasted growth in electricity demand as California switch to electric vehicles and appliances. This could help to establish energy storage and PV generation as a “pseudo firm” generation resource mix if managed appropriately and provide sufficient resource adequacy for distribution capacity upgrade deferrals.

14 SOLAR ENERGY↗

Disorder to Order in Interface Patterns: Thermal Noise to Limit Cycle Transition in Dendrite Sidebranch Formation

Thin sample directional solidification experiments have been carried out in the model succinonitrile-camphor system to examine the origin of secondary branches in dendrite morphologies. Thermal noise at the dendrite tip creates interface instabilities which amplify to form sidebranches. This is accepted as the primary mode of sidebranching in dendritic growth from an undercooled melt and occurs in directional solidification of dendrites. The proposed limit cycle couples the growth of the tip with the initiation of the sidebranch. Directional solidification of curved interfaces is a driven dissipative system with the potential to form a limit cycle. Two sets of experiments were performed, the first holding velocity constant and evolving the gradient and the second imposing oscillating velocities around the natural period of sidebranching. Both experimental methods were found to characterize a transition from disordered sidebranching induced by thermal noise to ordered sidebranching produced by the limit cycle mechanisms. This is the first quantitative measurement of previously hypothesized limit cycle growth. These experiment sets have been quantitatively analyzed for dynamic behavior seen in limit cycles. High-quality data sets of the tip and instability enable the measurement of the FFT and analysis through a power spectrum. At low gradients, the sidebranches are found to be excited by thermal noise far away from the tip. As the gradient increases and velocity is held constant, the distance between the instability and tip decreases until limit cycle growth is found between the tip of the primary dendrite and the first forming sidebranch. An alternative to the deterministic limit cycles seen in experiments of gradient evolution is a limit cycle actively driven through the square wave oscillation of velocity. Crucial observations of the solidified microstructure conclude that this produced periodic interconnected bridges between the primary dendrites. This is a finding with potentially significant implications for commercial applications.

Trevor Lyons↗

RECENT ADVANCES IN HIGH TEMPERATURE ELECTROLYSIS AT IDAHO NATIONAL LABORATORY: STACK TESTS

High temperature steam electrolysis is a promising technology for efficient sustainable large-scale hydrogen production. Solid oxide electrolysis cells (SOECs) are able to utilize high temperature heat and electric power from advanced high-temperature nuclear reactors or renewable sources to generate carbon-free hydrogen at large scale. However, long term durability of SOECs needs to be improved significantly before commercialization of this technology. A degradation rate of 1%/khr or lower is proposed as a threshold value for commercialization of this technology. Solid oxide electrolysis stack tests have been conducted at Idaho National Laboratory to demonstrate recent improvements in long-term durability of SOECs. Electrolytesupported and electrode-supported SOEC stacks were provided by Ceramatec Inc., Materials and Systems Research Inc. (MSRI), and Saint Gobain Advanced Materials (St. Gobain), respectively for these tests. Long-term durability tests were generally operated for a duration of 1000 hours or more. Stack tests based on technology developed at Ceramatec and MSRI have shown significant improvement in durability in the electrolysis mode. Long-term degradation rates of 3.2%/khr and 4.6%/khr were observed for MSRI and Ceramatec stacks, respectively. One recent Ceramatec stack even showed negative degradation (performance improvement) over 1900 hours of operation. A three-cell short stack provided by St. Gobain, however, showed rapid degradation in the electrolysis mode. Improvements on electrode materials, interconnect coatings, and electrolyteelectrode interface microstructures contribute to better durability of SOEC stacks.

08 HYDROGEN↗

On the operational characteristics and economic value of pumped thermal energy storage

Pumped thermal energy storage (PTES) systems use an electrically-driven heat pump to store electricity in the form of thermal energy, and subsequently dispatch the stored thermal energy to generate electricity using a thermodynamic heat engine. Optimal day-ahead operational scheduling and annual value of a PTES system based on Joule-Brayton thermodynamic cycles and two-tank molten salt hot thermal storage is evaluated in this work. Production cost models, which simultaneously optimize commitment and dispatch schedules for an entire set of generators to minimize the cost of satisfying electricity demand, are employed to determine system-optimal operation and day-ahead energy value of the PTES system within each of six hypothetical near-future grid scenarios intended to approximately represent the U.S. Western Interconnection or the Texas Interconnection. Sensitivity to grid scenario (including the contribution of variable renewable energy sources), thermal storage capacity, relative heat pump and heat engine capacities, and startup/shutdown cycling costs are evaluated. PTES energy value and heat engine annual capacity factor increase strongly as the contribution of variable renewable resources increases, heat pump capacity increases relative to heat engine capacity, or PTES cycling costs decrease. Grid scenarios in which the contribution of variable renewable energy is dominated by solar photovoltaics (PV) vs. wind produce inherently different PTES operational patterns. Annual PTES energy value within PV-dominated scenarios increased with storage capacity only up to approximately seven hours of full-load discharge capacity, whereas that within wind-dominated scenarios exhibited a continual increase with storage duration up to at least 16 hours.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Biomimetic, Soft-Material Synapse for Neuromorphic Computing: from Device to Network

Neuromorphic computing refers to a variety of brain-inspired computers, devices, and models inspired by the interconnectivity, performance, and energy efficiency of the human brain. Unlike the ubiquitous von Neumann computer architectures with complex processor cores and sequential computation, biological neurons and synapses operate by storing and processing information simultaneously with the capacity of flexible adaptation resulting in massive computational capability with much less power consumption. The search for a synaptic material which can closely imitate bio-synapse has led to an alamethicin-doped, synthetic biomembrane which can emulate key synaptic functions due to generic memristive property enabling learning and computation. This two-terminal, biomolecular memristor, in contrast to its solid-state counterparts, features similar structure, switching mechanism, and ionic transport modality as biological synapses while consuming considerably lower power. In this paper, we outline a methodology for using this biomolecular synapse to build neural networks capable of solving real-world problems. The physical mechanism underlying its volatile memristance is explored followed by the development of a model of this device for circuit simulation. We outline a circuit design technique to integrate this synapse with solid-state neuron circuit for hardware implementation. Based on these results, we develop a high level simulation framework and use a training scheme called Evolutionary Optimization for Neuromorphic System (EONS) to generate networks for solving two problems, namely iris dataset classification and EEG classification task. The small network size and comparable to state-of-the-art accuracy of these preliminary networks show its potential to enhance synaptic functionality in next generation neuromorphic hardware.

Sakib hasan, Md↗

An Assessment of Helium Evolution from Helium-Saturated Propellant Depressurization in Space

Helium evolution from the transfer of helium-saturated propellant in space is quantified to assess its impacts from creating two-phase gas/liquid flow from the supply tank, gas injection into the receiving tank, and liquid discharge from the receiving tank. Propellant transfer takes place between two similar tanks whose maximum storage capacity is approximately 2.55 cubic meters each. The maximum on-orbit propellants transfer capability is 9000 lbm (fuel and oxidizer). The transfer line is approximately 1.27 cm in diameter and 6096 cm in length and comprised of the fluid interconnect system (FICS), the orbiter propellant transfer system (OPTS), and the International Space Station (ISS) propulsion module (ISSPM). The propellant transfer rate begins at approximately 11 liter per minute (lpm) and subsequently drops to approximately 0.5 lpm. The tank nominal operating pressure is approximately 1827 kPa (absolute). The line pressure drops for Monomethy1hydrazine (MMH) and Nitrogen tetroxide (NTO) at 11.3 lpm are approximately 202 kPa and 302 kPa, respectively. The pressure-drop results are based on a single-phase flow. The receiving tank is required to vent from approximately 1827 kPa to a lower pressure to affect propellant transfer. These pressure-drop scenarios cause the helium-saturated propellants to release excess helium. For tank ullage venting, the maximum volumes of helium evolved at tank pressure are approximately 0.5 ft3 for MMH and 2 ft3 for NTO. In microgravity environment, due to lack of body force, the helium evolution from a liquid body acts to propel it, which influences its fluid dynamics. For propellant transfer, the volume fractions of helium evolved at line pressure are 0.1% by volume for MMH and 0.6 % by volume for NTO at 11.3 lpm. The void fraction of helium evolved varies as an approximate second order power function of flow rate.

Nguyen, Bich N.↗

Framework for optimization of long-term, multi-period investment planning of integrated urban energy systems

In order to achieve stringent greenhouse gas emission reductions, a transition of our entire energy system from fossil to renewable resources needs to be designed. Such an energy transition brings two main challenges: most renewables generate variable electric energy, yet most demand is currently not electric (carrier mismatch) and does not always manifest at the same time as supply (temporal mismatch). Integrating multiple energy infrastructures can address both challenges by using the synergy between different energy carriers; building on existing infrastructure, while allowing a robust and flexible integration of the new. This paper proposes an optimization framework for long-term, multi-period investment planning of urban energy systems in an integrated manner. We formulate it as a mixed-integer linear program, combining a capacitated facility location with a multi-dimensional, capacitated network design problem. It includes generation and network expansion planning as well as interconnections between networks and storage infrastructure for each energy system. It can incorporate pathway effects like techno-economic developments, policy measures, and weather variations. The intended use is to support urban decision makers with long-term investment planning, though it can be tailored to fit other geographical or temporal scales. We demonstrate the model using two cases based on an average city in The Netherlands, which wants to reduce its CO 2 -emissions with 95% by 2050. In the first case, we include explicit carbon-emission constraints to study the effects of the carrier mismatch. In the second case, we implement interannual weather variations to analyze the temporal mismatch. The results give valuable insights into the energy transition design strategy for urban decision makers. They also show the future potential, as well as the computational challenges of the optimization framework.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Energy-Water Nexus Knowledge Discovery Framework, Experts' Meeting

Energy and water generation and delivery systems are inherently interconnected. With demand for energy growing, the energy sector is experiencing increasing competition for water. With increasing populationand changing environmental, socioeconomic, and demographic scenarios, new technology and investmentdecisions must be made for optimized and sustainable energy-water resource management. These decisionsrequire novel scientific insights into the complex interdependencies of energy-water infrastructures acrossmultiple space and time scales.On June 13, 2017 an Experts’ Meeting was convened for the purpose of informing the design of an integrateddata driven modeling, analysis, and visualization capability that can enable ecient local and regional decisionmakingregarding present and future energy-water infrastructure. This first multi-institute collaborativeEnergy-Water Nexus Knowledge Discovery Framework (EWN-KDF) will be informed by fundamentalscience and guided with strategic (federal) policy decisions in the service of ensuring national energyresilience.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Review of Visualization Methods for Cyber-Physical Security: Smart Grid Case Study

Cyber-Physical Systems (CPSs) are becoming increasingly complex and interconnected as they attempt to meet the demands of evolving society. As a result, monitoring and maintaining them becomes a more complex and demanding task for control system operators and cyber defenders. While the literature on visualization techniques in the context of cybersecurity is extensive, the same cannot be said for studies on visualization for the security of cyber-physical systems. This paper aims to fill that gap by: 1) defining the main features of a visualizations workflow for security visualizations in cyber-physical systems. The workflow includes the acquisition of cyber and physical data, processing of data, selection, and configuration of both visualization tools and end-user interactions. 2) Providing an overview of cyber-physical security visualization systems, with a focus on smart grids as a case study. Finally, we use the perspectives gained from this analysis to provide insights and directions for future research and design of cyber-physical visualization techniques.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Stress Intensity of Delamination in a Sintered-Silver Interconnection: Preprint

In automotive power electronics packages, conventional thermal interface materials such as greases, gels, and phase-change materials pose bottlenecks to heat removal and are also associated with reliability concerns. The industry trend is toward high thermal performance bonded interfaces for large-area attachments. However, because of coefficient of thermal expansion mismatches between materials/layers and resultant thermomechanical stresses, adhesive and cohesive fractures could occur, posing a reliability problem. These defects manifest themselves in increased thermal resistance. This research aims to investigate and improve the thermal performance and reliability of sintered-silver for power electronics packaging applications. This has been experimentally accomplished by the synthesis of large-area bonded interfaces between metalized substrates and copper base plates that have subsequently been subjected to thermal cycles. A finite element model of crack initiation and propagation in these bonded interfaces will allow for the interpretation of degradation rates by a crack-velocity (V)-stress intensity factor (K) analysis. A description of the experiment and the modeling approach are discussed.

30 DIRECT ENERGY CONVERSION↗

Chromium Vapor Sensor for Monitoring Solid Oxide Fuel Cell Systems

One of the major degradation mechanisms in solid oxide fuel cells (SOFCs) is cathode poisoning by chromium due to vaporization from the metallic interconnect or balance-of-plant materials. Information on the chromium content in an operating fuel cell would be useful to anticipate degradation and take appropriate precautions. In this project, sensors for measuring the concentration of chromium-containing gases in a SOFC system were developed. The sensors are electrochemical sensors based on solid electrolytes with an auxiliary electrode to provide the sensitivity to chromium. Two different solid electrolyte materials were used: An oxygen ion conducting electrolyte, yttria stabilized zirconia, and a sodium ion conducting electrolyte, beta” alumina. The sensor based on beta” alumina generated a larger response to the presence of chromium. The concept of using a thin-film conducting oxide to measure the cumulative amount of chromium was also evaluated. The sensor was based on amanganese-copper oxide thin film and underwent an increase in resistance upon exposure to a chromium-containing gas.

20 FOSSIL-FUELED POWER PLANTS↗

Shifts in hydropower operation to balance wind and solar will modify effects on aquatic biota

To avoid negative consequences to freshwater biota from climate change, society must complete the transition from fossil to renewable electricity sources. However, temporal patterns in hydropower generation (and flow releases that affect aquatic biota) may change with increased wind and solar penetration. We used power cost modeling to characterize current and future within-day and seasonal patterns in hydropower generation across the Eastern Interconnection in a wet and a dry year. Compared to the baseline, future hydropower generation across the grid decreased during the day and increased before dawn and after dusk. At a project level, such a pattern would suggest 'double peaking' operation (up- and down-ramping before dawn and after dusk, with lower releases midday). Variation in generation was higher in wet years than dry years, foreshadowing possible flow constraints on hydropower flexibility. At the grid scale, projected ramping rates were higher in all seasons. A review of the ecological literature suggests that these changes would shift the timing of invertebrate drift and elevate the risk of nest scouring during up-ramping and the risk of stranding or dewatering during down ramping. Thermal conditions may be moderated by increased ramping. Strategies for adapting to future shifts in the renewable portfolio range from re-regulation in reservoir cascades to providing flow refuge (structures and vegetation) below individual projects. Coordinated basin-scale operation can distribute peaking operation to maintain grid support while restricting local ramping at critical ecological times. In addition, research to design hybrid renewable systems that add battery storage is needed to understand how we can mitigate future risks to aquatic communities while promoting the use of renewable energy. This study, which is among the first to examine ecological side-effects of the shift to renewable energy in freshwater ecosystems, lays out a path toward understanding and navigating changes to flow regimes under the energy transition.

54 ENVIRONMENTAL SCIENCES↗

Impacts of Alternative Operations and Renewable Energy Deployment on Columbia River Hydropower

The Columbia River Treaty Tribes in the Pacific Northwest - the Nez Perce, Umatilla, Warm Springs, and Yakama - hold treaty-reserved fishing rights for the Columbia River, one of the world's most productive salmon rivers and a critical resource for these tribes. However, the tribes have expressed that current operating regimes of hydropower dams throughout the Columbia River Basin (CRB) do not fully account for tribal fishing rights and have negatively impacted fish populations. Four tribes acting together through the Columbia River Inter-Tribal Fish Commission (CRITFC)'s 2022 Energy Vision stated that current power system models often do not fully account for the many constraints faced by hydropower facilities in the CRB. As the deployment of variable renewable energy (VRE) like solar and wind continues to increase, power system flexibility will become increasingly important. As a result, there is a growing need to better understand the true capabilities of the hydropower generation fleet while accurately accounting for ecological constraints (Northwest Power and Conservation Council 2022). Understanding hydropower's role in a future grid with a higher share of VRE can inform water resources planning to address ecological needs. The goal of this study is to examine the impacts of alternative hydropower operation rules and weather variability on hydropower generation and grid operations in VRE and transmission infrastructure deployment scenarios. The study evaluates how hydropower scheduling practices can reduce ecological impacts to the region's salmon populations. More specifically, the study examines the impact of today's dam water release rules (called "adjusted base water rules" in this study) and new, ecologically informed water release rules (called "ecosystem water rules" in this study) on two VRE scenarios (current renewable energy levels and higher renewable energy levels) using six weather years for each scenario (2008-2013). CRITFC developed the ecosystem water rules, which capture a portion of the changes they recommend for CRB hydropower operations. These analyses use a water resource planning model (OASIS) and a production cost model (PLEXOS) to simulate CRB reservoir cascade and Western Interconnection power grid operation.

13 HYDRO ENERGY↗

Event Screening Methods for the Eastern Interconnection Situational Awareness and Monitoring System (ESAMS)

The Eastern Interconnection Situational Awareness and Monitoring System (ESAMS) is a tool developed to explore the applications and advantages of sharing phasor measurement unit (PMU) data among operating entities. An initial conclusion from testing was that detected events required further screening before being reported to ensure that events would be of interest to system operators. The methods described in this report were integrated into ESAMS to meet this need. First, an event is screened for whether the change in voltage angle measurements indicates that the detected disturbance is sufficiently large. Next, an event is classified to determine if it was related to a loss of generation. Finally, a neural network is used to determine if the system’s response to the disturbance is normal or abnormal. These methods were tested with one month of field-measured PMU data. Results indicate that the additional information provided by these additional screening tools will improve selection of events for inclusion in the daily event reports automatically generated by ESAMS.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Optimal Voltage Reference for Droop-Based DERs in Distribution Systems

Due to the newly issued standards on distributed energy resources (DERs), the droop-based operation modes (Q-V and P-V droops) become a requirement for all the interconnected DER units at the distribution level. Voltage references of the DER units can be assigned to improve the operational behavior of the distribution system in the smart grid context. This paper presents a novel formulation for optimally setting voltage reference of the droop-based DER units in distribution systems with the objective of minimizing the system ohmic loss. This problem is formulated as a mixed-integer quadratic convex optimization problem in MATLAB and solved by the MATLAB and CPLEX solvers. The IEEE 123-bus system and the EPRI test system Ckt5 are used to validate the proposed formulation. The result obtained from the proposed formulation is compared with the result of the original problem solved by the heuristic method. Based on the numerical study results, system loss can be reduced after the proposed voltage reference assignment. The computational expense of the new formulation is also much lower than that of the heuristic approach.

distributed energy resource integration↗

Statistical Analysis of Inter-Area Oscillations in the U.S. Eastern Interconnection: A 2017-2023 Perspective

Recent advancements and the accumulation of high-resolution, long-term phasor measurement unit (PMU) data have provided detailed insights into inter-area oscillations in power grids. This study conducts a comprehensive statistical analysis of inter-area oscillations within the United States Eastern Interconnection from 2017 to 2023. Utilizing data captured by the advanced wide-area Frequency Monitoring Network (FNET/GridEye), this investigation examines the occurrence patterns, dominant frequencies, damping ratios, and excitation mechanisms of these oscillations. Our analysis sheds light on the evolving statistical behaviors of inter-area oscillations, offering updated and critical information for grid operators and planners. The insights gained from this study can be instrumental in enhancing the operational resilience of the power network and guiding strategic developments in grid infrastructure to accommodate future challenges. Additionally, the study discusses emerging challenges associated with the modernization of the power grid, including increased renewable penetration, dynamic load variability, and cyber-physical vulnerabilities that complicate oscillation monitoring and control.