Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Homogenization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,405 records · Page 78

Heat transfer simulation and thermal measurements of microfabricated x-ray transparent heater stages

A microfabricated amorphous silicon nitride membrane-based nanocalorimeter is proposed to be suitable for an x-ray transparent sample platform with low power heating and built-in temperature sensing. In this work, thermal characterization in both air and vacuum are analyzed experimentally and via simulation. Infrared microscopy and thermoreflectance microscopy are used for thermal imaging of the sample area in air. While a reasonably large isothermal area is found on the sample area, the temperature homogeneity of the entire sample area is low, limiting use of the device as a heater stage in air or other gases. A simulation model that includes conduction, as well as radiation and convection heat loss, is presented with radiation and convection parameters determined experimentally. Simulated temperature distributions show that the homogeneity can be improved by using a thicker thermal conduction layer or reducing the pressure of the gas in the environment but neither are good solutions for the proposed use. A new simple design that has improved temperature homogeneity and a larger isothermal area while maintaining a thin thermal conduction layer is proposed and fabricated. This new design enables applications in transmission x-ray microscopes and spectroscopy setups at atmospheric pressure.

47 OTHER INSTRUMENTATION↗

Comparison of dose calculation methods for brachytherapy of intraocular tumors

Purpose: To investigate dosimetric differences among several clinical treatment planning systems (TPS) and Monte Carlo (MC) codes for brachytherapy of intraocular tumors using {sup 125}I or {sup 103}Pd plaques, and to evaluate the impact on the prescription dose of the adoption of MC codes and certain versions of a TPS (Plaque Simulator with optional modules). Methods: Three clinical brachytherapy TPS capable of intraocular brachytherapy treatment planning and two MC codes were compared. The TPS investigated were Pinnacle v8.0dp1, BrachyVision v8.1, and Plaque Simulator v5.3.9, all of which use the AAPM TG-43 formalism in water. The Plaque Simulator software can also handle some correction factors from MC simulations. The MC codes used are MCNP5 v1.40 and BrachyDose/EGSnrc. Using these TPS and MC codes, three types of calculations were performed: homogeneous medium with point sources (for the TPS only, using the 1D TG-43 dose calculation formalism); homogeneous medium with line sources (TPS with 2D TG-43 dose calculation formalism and MC codes); and plaque heterogeneity-corrected line sources (Plaque Simulator with modified 2D TG-43 dose calculation formalism and MC codes). Comparisons were made of doses calculated at points-of-interest on the plaque central-axis and at off-axis points of clinical interest within a standardized model of the right eye. Results: For the homogeneous water medium case, agreement was within {approx}2% for the point- and line-source models when comparing between TPS and between TPS and MC codes, respectively. For the heterogeneous medium case, dose differences (as calculated using the MC codes and Plaque Simulator) differ by up to 37% on the central-axis in comparison to the homogeneous water calculations. A prescription dose of 85 Gy at 5 mm depth based on calculations in a homogeneous medium delivers 76 Gy and 67 Gy for specific {sup 125}I and {sup 103}Pd sources, respectively, when accounting for COMS-plaque heterogeneities. For off-axis points-of-interest, dose differences approached factors of 7 and 12 at some positions for {sup 125}I and {sup 103}Pd, respectively. There was good agreement ({approx}3%) among MC codes and Plaque Simulator results when appropriate parameters calculated using MC codes were input into Plaque Simulator. Plaque Simulator and MC users are perhaps at risk of overdosing patients up to 20% if heterogeneity corrections are used and the prescribed dose is not modified appropriately. Conclusions: Agreement within 2% was observed among conventional brachytherapy TPS and MC codes for intraocular brachytherapy dose calculations in a homogeneous water environment. In general, the magnitude of dose errors incurred by ignoring the effect of the plaque backing and Silastic insert (i.e., by using the TG-43 approach) increased with distance from the plaque's central-axis. Considering the presence of material heterogeneities in a typical eye plaque, the best method in this study for dose calculations is a verified MC simulation.

60 APPLIED LIFE SCIENCES↗

Dose-shaping using targeted sparse optimization

Purpose: Dose volume histograms (DVHs) are common tools in radiation therapy treatment planning to characterize plan quality. As statistical metrics, DVHs provide a compact summary of the underlying plan at the cost of losing spatial information: the same or similar dose-volume histograms can arise from substantially different spatial dose maps. This is exactly the reason why physicians and physicists scrutinize dose maps even after they satisfy all DVH endpoints numerically. However, up to this point, little has been done to control spatial phenomena, such as the spatial distribution of hot spots, which has significant clinical implications. To this end, the authors propose a novel objective function that enables a more direct tradeoff between target coverage, organ-sparing, and planning target volume (PTV) homogeneity, and presents our findings from four prostate cases, a pancreas case, and a head-and-neck case to illustrate the advantages and general applicability of our method.Methods: In designing the energy minimization objective (E{sub tot}{sup sparse}), the authors utilized the following robust cost functions: (1) an asymmetric linear well function to allow differential penalties for underdose, relaxation of prescription dose, and overdose in the PTV; (2) a two-piece linear function to heavily penalize high dose and mildly penalize low and intermediate dose in organs-at risk (OARs); and (3) a total variation energy, i.e., the L{sub 1} norm applied to the first-order approximation of the dose gradient in the PTV. By minimizing a weighted sum of these robust costs, general conformity to dose prescription and dose-gradient prescription is achieved while encouraging prescription violations to follow a Laplace distribution. In contrast, conventional quadratic objectives are associated with a Gaussian distribution of violations, which is less forgiving to large violations of prescription than the Laplace distribution. As a result, the proposed objective E{sub tot}{sup sparse} improves tradeoff between planning goals by 'sacrificing' voxels that have already been violated to improve PTV coverage, PTV homogeneity, and/or OAR-sparing. In doing so, overall plan quality is increased since these large violations only arise if a net reduction in E{sub tot}{sup sparse} occurs as a result. For example, large violations to dose prescription in the PTV in E{sub tot}{sup sparse}-optimized plans will naturally localize to voxels in and around PTV-OAR overlaps where OAR-sparing may be increased without compromising target coverage. The authors compared the results of our method and the corresponding clinical plans using analyses of DVH plots, dose maps, and two quantitative metrics that quantify PTV homogeneity and overdose. These metrics do not penalize underdose since E{sub tot}{sup sparse}-optimized plans were planned such that their target coverage was similar or better than that of the clinical plans. Finally, plan deliverability was assessed with the 2D modulation index.Results: The proposed method was implemented using IBM's CPLEX optimization package (ILOG CPLEX, Sunnyvale, CA) and required 1-4 min to solve with a 12-core Intel i7 processor. In the testing procedure, the authors optimized for several points on the Pareto surface of four 7-field 6MV prostate cases that were optimized for different levels of PTV homogeneity and OAR-sparing. The generated results were compared against each other and the clinical plan by analyzing their DVH plots and dose maps. After developing intuition by planning the four prostate cases, which had relatively few tradeoffs, the authors applied our method to a 7-field 6 MV pancreas case and a 9-field 6MV head-and-neck case to test the potential impact of our method on more challenging cases. The authors found that our formulation: (1) provided excellent flexibility for balancing OAR-sparing with PTV homogeneity; and (2) permitted the dose planner more control over the evolution of the PTV's spatial dose distribution than conventional objective functions. In particular, E{sub tot}{sup sparse}-optimized plans for the pancreas case and head-and-neck case exhibited substantially improved sparing of the spinal cord and parotid glands, respectively, while maintaining or improving sparing for other OARs and markedly improving PTV homogeneity. Plan deliverability for E{sub tot}{sup sparse}-optimized plans was shown to be better than their associated clinical plans, according to the two-dimensional modulation index.Conclusions: These results suggest that our formulation may be used to improve dose-shaping and OAR-sparing for complicated disease sites, such as the pancreas or head and neck. Furthermore, our objective function and constraints are linear and constitute a linear program, which converges to the global minimum quickly, and can be easily implemented in treatment planning software. Thus, the authors expect fast translation of our method to the clinic where it may have a positive impact on plan quality for challenging disease sites.

61 RADIATION PROTECTION AND DOSIMETRY↗

Forward treatment planning for modulated electron radiotherapy (MERT) employing Monte Carlo methods

Purpose: This paper describes the development of a forward planning process for modulated electron radiotherapy (MERT). The approach is based on a previously developed electron beam model used to calculate dose distributions of electron beams shaped by a photon multi leaf collimator (pMLC). Methods: As the electron beam model has already been implemented into the Swiss Monte Carlo Plan environment, the Eclipse treatment planning system (Varian Medical Systems, Palo Alto, CA) can be included in the planning process for MERT. In a first step, CT data are imported into Eclipse and a pMLC shaped electron beam is set up. This initial electron beam is then divided into segments, with the electron energy in each segment chosen according to the distal depth of the planning target volume (PTV) in beam direction. In order to improve the homogeneity of the dose distribution in the PTV, a feathering process (Gaussian edge feathering) is launched, which results in a number of feathered segments. For each of these segments a dose calculation is performed employing the in-house developed electron beam model along with the macro Monte Carlo dose calculation algorithm. Finally, an automated weight optimization of all segments is carried out and the total dose distribution is read back into Eclipse for display and evaluation. One academic and two clinical situations are investigated for possible benefits of MERT treatment compared to standard treatments performed in our clinics and treatment with a bolus electron conformal (BolusECT) method. Results: The MERT treatment plan of the academic case was superior to the standard single segment electron treatment plan in terms of organs at risk (OAR) sparing. Further, a comparison between an unfeathered and a feathered MERT plan showed better PTV coverage and homogeneity for the feathered plan, with V{sub 95%} increased from 90% to 96% and V{sub 107%} decreased from 8% to nearly 0%. For a clinical breast boost irradiation, the MERT plan led to a similar homogeneity in the PTV compared to the standard treatment plan while the mean body dose was lower for the MERT plan. Regarding the second clinical case, a whole breast treatment, MERT resulted in a reduction of the lung volume receiving more than 45% of the prescribed dose when compared to the standard plan. On the other hand, the MERT plan leads to a larger low-dose lung volume and a degraded dose homogeneity in the PTV. For the clinical cases evaluated in this work, treatment plans using the BolusECT technique resulted in a more homogenous PTV and CTV coverage but higher doses to the OARs than the MERT plans. Conclusions: MERT treatments were successfully planned for phantom and clinical cases, applying a newly developed intuitive and efficient forward planning strategy that employs a MC based electron beam model for pMLC shaped electron beams. It is shown that MERT can lead to a dose reduction in OARs compared to other methods. The process of feathering MERT segments results in an improvement of the dose homogeneity in the PTV.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-F-T-679: Monte Carlo Simulation On Surface Dose in Preclinical Irradiation Using Monoenergetic Photon Beams

Purpose: This study investigated the surface dose variation in preclinical irradiation using small animal, when monoenergetic photon beams with energy range from 50 keV to 1.25 MeV were used. Methods: Inhomogeneous, homogeneous and bone-tissue homogeneous mouse phantom based on the same CT image set were used. The homogeneous and bone-tissue homogeneous phantom were created with the relative electron density of all and only bone voxels of the mouse overridden to one, respectively. Monte Carlo simulation based on the EGSnrc-based code was used to calculate the surface dose, when the phantoms were irradiated by a 360° photon arc with energies ranging from 50 keV to 1.25 MeV. The mean surface doses of the three phantoms were calculated. In addition, the surface doses from partial arcs, 45°–315°, 125°–225°, 45°–125° and 225°–315° covering the anterior, posterior, right lateral and left lateral region of the mouse were determined using different photon beam energies. Results: When the prescribed dose at the isocenter of the mouse was 2 Gy, the maximum mean surface doses, found at the 50-keV photon beams, were 0.358 Gy, 0.363 Gy and 0.350 Gy for the inhomogeneous, homogeneous and bone-tissue homogeneous mouse phantom, respectively. The mean surface dose of the mouse was found decreasing with an increase of the photon beam energy. For surface dose in different orientations, the lateral regions of the mouse were receiving lower dose than the anterior and posterior regions. This may be due to the increase of beam attenuation along the horizontal (left-right) axis than the vertical (anterior-posterior) in the mouse. Conclusion: It is concluded that consideration of phantom inhomogeneity in the dose calculation resulted in a lower mean surface dose of the mouse. The mean surface dose also decreased with an increase of photon beam energy in the kilovoltage range.

60 APPLIED LIFE SCIENCES↗

Field-Induced Spin-Modulated Transitions in Epitaxial (001) BiFeO{sub 3} Films

Alterations in the ground state of thin (001) films of a BiFeO{sub 3} (BFO)-type multiferroic in a magnetic field are studied theoretically, with changes in the energy of induced anisotropy taken into account. The anisotropy vs. field phase diagrams identifying the stability regions of homogeneous antiferromagnetic states and the regions of emergence of spatially modulated antiferromagnetic states are constructed for three mutually orthogonal orientations of applied magnetic field. We show that, as the magnetic field decreases, the transformation of a homogeneous phase into a spatially modulated state occurs at the instability point of the homogeneous state via gradual emergence of the conical phase that transforms into a planar cycloid with the decreasing magnetic field. A multiferroic film grown on a (001) substrate develops considerable anisotropy of the energy of spatially modulated state, depending on the modulation orientation. Meanwhile, cycloids with different orientations undergo the transitions from incommensurate phase into the homogeneous state differently: either the conical cycloid is formed followed by its collapse into the homogeneous state or an unlimitedly growing domain of the homogeneous phase is formed within the flat cycloid. Examples of field-induced changes in magnetization, with changes in spin states taken into account, are provided. These results are of value in practical applications of multiferroic strain engineering.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

The Dual Nature of Entrainment-Mixing Signatures Revealed through Large-Eddy Simulations of a Convection-Cloud Chamber

Abstract Entrainment of subsaturated air into a cloud can influence its optical and microphysical properties in various ways, depending on the droplet evaporation and turbulent mixing time scales. Previous experiments in the Pi convection-cloud chamber have revealed that, given a fixed entrained air property, the mixing of entrained subsaturated air results in complete evaporation of some cloud droplets, with the rest remaining unchanged. This is a signature of inhomogeneous mixing. While comparing the results of entrainment with varying air properties, the mixing signature appears as if the subsaturated air is well mixed with the cloud to evenly reduce the droplets’ size. In other words, taken together, the experiments appear to have the signature of homogeneous mixing. To explore these results in a greater depth, we conduct large-eddy simulations combined with a bin microphysics scheme. Our results reproduce the similar signatures of inhomogeneous and homogeneous mixing, implying that LES can resolve the inhomogeneous mixing when the grid spacing is smaller than the entrained air parcel. Additionally, we observe that increasing the aerosol injection rate enhances the signature of inhomogeneous mixing, while coarser grid spacing diminishes it. Finally, the change in wall fluxes in response to various entrained air properties confirms that the homogeneous signature seen in the analysis of an ensemble of simulations is the result of various equilibrium states. This further strengthens the suggestion that the homogeneous mixing signature found in aircraft observations near the cloud top may result from combining entrainment events of different intensities, possibly caused by various-sized eddies. Significance Statement Large-eddy simulation and size-resolved microphysics can resolve time scales for turbulent mixing and evaporation and, therefore, are well suited for reproducing, extending, and interpreting the entrainment experiment in the Pi convection-cloud chamber. Our simulation results confirm (i) the inhomogeneous mixing signature for an individual entrainment event and (ii) the appearance of homogeneous mixing in an ensemble of entrainment episodes. Furthermore, we demonstrate that the inhomogeneous mixing signature is more pronounced in a polluted cloud, but coarser grid spacing in simulations may compromise the accuracy of this signature. Last, the homogeneous mixing signature results from various equilibrium states established for different entrainment intensities and adjusted wall fluxes, which are challenging to measure experimentally but can be easily analyzed in the simulations.

54 ENVIRONMENTAL SCIENCES↗

Evaluating Entrainment–Mixing Characteristics through Direct Comparisons of Drop Size Distributions Using In Situ Observations from ACE-ENA

Abstract Constraining the impacts of entrainment and associated mixing (i.e., entrainment–mixing) on cloud properties continues to be difficult, partly due to observational uncertainties as well as a lacking consensus of which methodologies for diagnosing entrainment–mixing are most appropriate. This study introduces a novel method to evaluate the presence and degree of inhomogeneous and homogeneous mixing using ∼100 h of in situ observations from a research aircraft over the northeastern Atlantic. Specifically, drop size distributions are compared between regions containing negligible and significant entrainment for select flight legs, making a direct characterization of the degree of homogeneous and inhomogeneous mixing possible. A measure of drop concentration variance is used as a proxy variable to diagnose entrainment–mixing. Results correspond well with entrainment–mixing metrics, showing lower Damköhler numbers where drop size distributions shift toward smaller drop sizes (i.e., inhomogeneous mixing) and greater transition length scales where drop size distributions do not (i.e., homogeneous mixing). Inhomogeneous mixing occurs in most samples from Aerosol and Cloud Experiment in the Eastern North Atlantic (ACE-ENA) (regardless of homogeneous mixing frequencies increasing with increasing spatial resolution from ∼100 to ∼10 m) and is associated with decreased drop size relative dispersion and both greater aerosol and drop concentrations compared with homogeneous mixing. Precipitating clouds have a greater frequency of homogeneous mixing compared with nonprecipitating clouds. The proposed methodology is similarly applied to in situ observations of southeast Pacific stratocumulus, shallow convective clouds over central Oklahoma and low-level clouds over the Southern Ocean. All four locations are primarily dominated by inhomogeneous mixing with minimal variability among each region.

Clouds↗

GCSS Cirrus Parcel Model Comparison Project

The Cirrus Parcel Model Comparison Project, a project of GCSS Working Group on Cirrus Cloud Systems (WG2), involves the systematic comparison of current models of ice crystal nucleation and growth for specified, typical, cirrus cloud environments. The goal of this project is to document and understand the factors resulting in significant inter-model differences. The intent is to foment research leading to model improvement and validation. In Phase 1 of the project reported here, simulated cirrus cloud microphysical properties are compared for situations of "warm" (-40 C) and "cold" (-60 C) cirrus subject to updrafts of 4, 20 and 100 cm/s, respectively. Five models participated. These models employ explicit microphysical schemes wherein the size distribution of each class of particles (aerosols and ice crystals) is resolved into bins. Simulations are made including both homogeneous and heterogeneous ice nucleation mechanisms. A single initial aerosol population of sulfuric acid particles is prescribed for all simulations. To isolate the treatment of the homogeneous freezing (of haze drops) nucleation process, the heterogeneous nucleation mechanism is disabled for a second parallel set of simulations. Qualitative agreement is found for the homogeneous-nucleation-only simulations, e.g., the number density of nucleated ice crystals increases with the strength of the prescribed updraft. However, non-negligible quantitative differences are found. Detailed analysis reveals that the homogeneous nucleation formulation, aerosol size, ice crystal growth rate (particularly the deposition coefficient), and water vapor uptake rate are critical components that lead to differences in predicted microphysics. Systematic bias exists between results based on a modified classical theory approach and models using an effective freezing temperature approach to the treatment of nucleation. Each approach is constrained by critical freezing data from laboratory studies, but each includes assumptions that can only be justified by further laboratory data. Consequently, it is not yet clear if the two approaches can be made consistent. Large haze particles may deviate considerably from equilibrium size in moderate to strong updrafts (20-100 cm/s) at -60 C when the commonly invoked equilibrium assumption is lifted. The resulting difference in particle-size-dependent solution concentration of haze particles may significantly affect the ice nucleation rate during the initial nucleation interval. The uptake rate for water vapor excess by ice crystals is another key component regulating the total number of nucleated ice crystals. This rate, the product of ice number concentration and ice crystal diffusional growth rate, which is sensitive to the deposition coefficient when ice particles are small, partially controls the peak nucleation rate achieved in an air parcel and the duration of the active nucleation time period. The effects of heterogeneous nucleation are most pronounced in weak updraft situations. Vapor competition by the nucleated (heterogeneous) ice crystals limits the achieved ice supersaturation and thus suppresses the contribution of homogeneous nucleation. Correspondingly, ice crystal number density is markedly reduced. Definitive laboratory and atmospheric benchmark data are needed for the heterogeneous nucleation process. Inter-model differences are correspondingly greater than in the case of the homogeneous nucleation process acting alone.

Lin, Ruei-Fong↗

Comparative Magma Oceanography

The question of whether the Earth ever passed through a magma ocean stage is of considerable interest. Geochemical evidence strongly suggests that the Moon had a magma ocean and the evidence is mounting that the same was true for Mars. Analyses of martian (SNC) meteorites have yielded insights into the differentiation history of Mars, and consequently, it is interesting to compare that planet to the Earth. Three primary features of Mars contrast strongly to those of the Earth: (i) the extremely ancient ages of the martian core, mantle, and crust (about 4.55 b.y.); (ii) the highly depleted nature of the martian mantle; and (iii) the extreme ranges of Nd isotopic compositions that arise within the crust and depleted mantle. The easiest way to explain the ages and diverse isotopic compositions of martian basalts is to postulate that Mars had an early magma ocean. Cumulates of this magma ocean were later remelted to form the SNC meteorite suite and some of these melts assimilated crustal materials enriched in incompatible elements. The REE pattern of the crust assimilated by these SNC magmas was LREE enriched. If this pattern is typical of the crust as a whole, the martian crust is probably similar in composition to melts generated by small degrees of partial melting (about 5%) of a primitive source. Higher degrees of partial melting would cause the crustal LREE pattern to be essentially flat. In the context of a magma ocean model, where large degrees of partial melting presumably prevailed, the crust would have to be dominated by late-stage, LREE-enriched residual liquids. Regardless of the exact physical setting, Nd and W isotopic evidence indicates that martian geochemical reservoirs must have formed early and that they have not been efficiently remixed since. The important point is that in both the Moon and Mars we see evidence of a magma ocean phase and that we recognize it as such. Several lines of theoretical inference point to an early Earth that was also hot and, perhaps, mostly molten. The Giant Impact hypothesis for the origin of the Moon offers a tremendous input of thermal energy and the same could be true for core formation. And current solar system models favor the formation of a limited number of large (about 1000 km) planetesimals that, upon accreting to Earth, would cause great heating, being lesser versions of the Giant Impact. Several lines of geochemical evidence do not favor this hot early Earth scenario. (i) Terrestrial man-tle xenoliths are sometimes nearly chondritic in their major element compositions, suggesting that these rocks have never been much molten. Large degrees of partial melting probably promote differentiation rather than homogenization. (ii) Unlike the case of Mars, the continental crust probably did not form as a highly fractionated residual liquid from a magma ocean (about 99% crystallization), but, rather, formed in multiple steps. [The simplest model for the formation of continental crust is complicated: (a) about 10% melting of a primitive mantle, making basalt; (b) hydrothermal alteration of that basalt, converting it to greenstone; and (c) 10% partial melting of that greenstone, producing tonalite.] This model is reinforced by the recent observation from old (about 4.1 b.y.) zircons that the early crust formed from an undepleted mantle having a chondritic Lu/Hf ratio. (iii) If the mantle were once differentiated by a magma ocean, the mantle xenolith suite requires that it subsequently be homogenized. The Os isotopic compositions of fertile spinel lherzolites place constraints on the timing of that homogenization. The Os isotopic composition of spinel lherzolites approaches that of chondrites and correlates with elements such as Lu and Al. As Lu and Al concentrations approach those of the primitive mantle, Os isotopic compositions approach chondritic. The Re and Os in these xenoliths were probably added as a late veneer. Thus, the mantle that received the late veneer must have been nearly chondritic in terms of its major elements (excluding Fe). If the mantle that the veneer was mixed into was not al-ready homogenized, then Os isotopes should not correlate with incompatible elements such as Al. Consequently, either early differentiation of the mantle did not occur or the homogenization of this differentiation must have occurred before the late veneer was added. The timing of the late veneer is itself uncertain but presumably postdated core formation at about 4.45 b.y. and did not postdate the 3.8-3.9 b.y. late bombardment of the Moon. This timing based on siderophile elements is consistent with the Hf isotopic evidence cited above. If the Earth, Moon and Mars had magma oceans, the Earth subsequently rehomogenized whereas the Moon and Mars did not. The simplest solution to this observation is that homogenization of igneous differentiates was never necessary on Earth, either because the hypothetical magma ocean never occurred or because this event did not produce mantle differentiation.

Jones, J. H.↗

Cirrus Parcel Model Comparison Project: The Critical Components to Simulate Cirrus Initiation Explicitly - Phase 1

The Cirrus Parcel Model Comparison Project, a project of the GCSS (GEWEX Cloud System Studies) Working Group on Cirrus Cloud Systems, involves the systematic comparison of current models of ice crystal nucleation and growth for specified, typical, cirrus cloud environments. In Phase I of the project reported here, simulated cirrus cloud microphysical properties are compared for situations of "warm" (40 C) and "cold" (-60 C) cirrus, both subject to updrafts of 4, 20 and 100 centimeters per second. Five models participated. The various models employ explicit microphysical schemes wherein the size distribution of each class of particles (aerosols and ice crystals) is resolved into bins or treated separately. Simulations are made including both the homogeneous and heterogeneous ice nucleation mechanisms. A single initial aerosol population of sulfuric acid particles is prescribed for all simulations. To isolate the treatment of the homogeneous freezing (of haze droplets) nucleation process, the heterogeneous nucleation mechanism is disabled for a second parallel set of simulations. Qualitative agreement is found for the homogeneous-nucleation- only simulations, e.g., the number density of nucleated ice crystals increases with the strength of the prescribed updraft. However, significant quantitative differences are found. Detailed analysis reveals that the homogeneous nucleation rate, haze particle solution concentration, and water vapor uptake rate by ice crystal growth (particularly as controlled by the deposition coefficient) are critical components that lead to differences in predicted microphysics. Systematic bias exists between results based on a modified classical theory approach and models using an effective freezing temperature approach to the treatment of nucleation. Each approach is constrained by critical freezing data from laboratory studies, but each includes assumptions that can only be justified by further laboratory research. Consequently, it is not yet clear if the two approaches can be made consistent. Large haze particles may deviate considerably from equilibrium size in moderate to strong updrafts (20-100 centimeters per second) at -60 C when the commonly invoked equilibrium assumption is lifted. The resulting difference in particle-size- dependent solution concentration of haze particles may significantly affect the ice particle formation rate during the initial nucleation interval. The uptake rate for water vapor excess by ice crystals is another key component regulating the total number of nucleated ice crystals. This rate, the product of particle number concentration and ice crystal diffusional growth rate, which is particularly sensitive to the deposition coefficient when ice particles are small, modulates the peak particle formation rate achieved in an air parcel and the duration of the active nucleation time period. The effects of heterogeneous nucleation are most pronounced in weak updraft situations. Vapor competition by the heterogeneously nucleated ice crystals may limit the achieved ice supersaturation and thus suppresses the contribution of homogeneous nucleation. Correspondingly, ice crystal number density is markedly reduced. Definitive laboratory and atmospheric benchmark data are needed for the heterogeneous nucleation process. Inter-model differences are correspondingly greater than in the case of the homogeneous nucleation process acting alone.

Lin, Ruei-Fong↗

Chronic alcohol consumption regulates the expression of poly immunoglobulin receptor (pIgR) and secretory IgA in the gut

The effect of ethanol (EtOH) on the gut immune system was analyzed using an experimental model previously described, where EtOH was provided ad libitum in the drinking water in a 20% w/v concentration for up to 12 weeks. Dendritic cells, T cells and macrophages were analyzed in Peyer's patches and the small intestines using flow cytometry. Cytokine and immunoglobulin levels were analyzed in sera, feces, and homogenates from small and large intestines and lungs. Decreases in the proportion of T cells and alterations in dendritic cells and macrophages were observed after EtOH treatment. Levels of immunoglobulin A (IgA) increased in tissue homogenates but decreased in small intestine fecal contents. Meanwhile poly-immunoglobulin receptor (pIgR) levels decreased in tissue homogenates and fecal contents. Levels of cytokines associated with the regulation of pIgR expression decreased for IL-10 and TGF-β, and increased for IFN-γ and IL-17 in the small intestine. The data indicate that chronic EtOH consumption disrupts the homeostasis of the mucosal immune system by altering the phenotype and functionality of multiple immune cell types, leading to a diminished secretion of SIgA, due to pIgR expression decreased. - Highlights: • Chronic alcohol (EtOH) alters monocytes and dendritic cells ratios in the gut. • EtOH decreases the number of T cells synthesizing IFN-γ in Peyer's patches. • EtOH decreases IgA and pIgR levels in small (SI) and large (LI) intestine feces. • EtOH decreases pIgR levels in SI homogenates. • EtOH favors the appearance of an inflammatory cytokine profile in SI homogenates.

60 APPLIED LIFE SCIENCES↗

Climatic warming in China during 1901–2015 based on an extended dataset of instrumental temperature records

Monthly mean instrumental surface air temperature (SAT) observations back to the nineteenth century in China are synthesized from different sources via specific quality-control, interpolation, and homogenization. Compared with the first homogenized long-term SAT dataset for China which contained 18 stations mainly located in the middle and eastern part of China, the present dataset includes homogenized monthly SAT series at 32 stations, with an extended coverage especially towards western China. Missing values are interpolated by using observations at nearby stations, including those from neighboring countries. Cross validation shows that the mean bias error (MBE) is generally small and falls between 0.45 °C and –0.35 °C. Multiple homogenization methods and available metadata are applied to assess the consistency of the time series and to adjust inhomogeneity biases. The homogenized annual mean SAT series shows a range of trends between 1.1 °C and 4.0 °C/century in northeastern China, between 0.4 °C and 1.9 °C/century in southeastern China, and between 1.4 °C and 3.7 °C/century in western China to the west of 105 E (from the initial years of the stations to 2015). The unadjusted data include unusually warm records during the 1940s and hence tend to underestimate the warming trends at a number of stations. As a result, the mean SAT series for China based on the climate anomaly method shows a warming trend of 1.56 °C/century during 1901–2015, larger than those based on other currently available datasets.

54 ENVIRONMENTAL SCIENCES↗

Analyzing photovoltaic module mechanics using composite plate theories and finite element solutions

Deflection and stress calculated from an experimentally validated, high-fidelity finite element model (FEM) of a photovoltaic module experiencing mechanical load was compared to results from a simplified FEM treating the module laminate as a homogenized composite using a rule of mixtures approach, and further compared to analytical calculations treating the module as a Kirchoff-Love flat plate. The goal of this study was to determine the error incurred by analyzing module mechanics with varying levels of simplification, since resolving the aspect ratios of a module is computationally expensive. Homogenized FEMs were found to underpredict peak deflection under a 1.0 kPa load by between 13 and 19% for lower and upper bound application of the rule of mixtures. However, module shape was captured, implying that a useful replication of a resolved model could be achieved with a reduced, calibrated material stiffness. Homogenized stress results captured glass layer tensile stress components to within 46 to 52% at a sample location of interest, though agreement was poor through the remainder of the laminate due to the lack of material resolution. For plate theory, deflection was overpredicted by 45 to 67% for upper and lower bound homogenizations, and frame-adjacent module shapes were not adequately replicated. Stress results mirrored FEM trends but magnitudes were not well correlated to resolved model values. These results support the use of homogenized laminate models for module shape derivation, though resolved models remain necessary for stress analyses. The accuracy of plate theory was found to be inadequate for most applications.

14 SOLAR ENERGY↗

Validation of the U.S. NRC NGNP evaluation model with the HTTR

The High Temperature Test Reactor (HTTR) was modeled with TRITON/PARCS. Traditional light water reactor (LWR) homogenization methods rely on the short mean free paths of neutrons in LWR. In gas-cooled, graphite-moderated reactors like the HTTR neutrons have much longer mean free paths and penetrate further into neighboring assemblies than in LWRs. Because of this, conventional lattice calculations with a single assembly may not be valid. In addition to difficulties caused by the longer mean free paths, the HTTR presents unique axial and radial heterogeneities that require additional modifications to the single assembly homogenization method. To handle these challenges, the homogenization domain is decreased while the computational domain is increased. Instead of homogenizing a single hexagonal fuel assembly, the assembly is split into six triangles on the radial plane and five blocks axially in order to account for the placement of burnable poisons. Furthermore, the radial domain is increased beyond a single fuel assembly to account for spectrum effects from neighboring fuel, reflector, and control rod assemblies. A series of five two-dimensional cases, each closer to the full core, were calculated to evaluate the effectiveness of the homogenization method and cross-sections. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Scale dependence of entrainment-mixing mechanisms in cumulus clouds

This work empirically examines the dependence of entrainment-mixing mechanisms on the averaging scale in cumulus clouds using in situ aircraft observations during the Routine Atmospheric Radiation Measurement Aerial Facility Clouds with Low Optical Water Depths Optical Radiative Observations (RACORO) field campaign. A new measure of homogeneous mixing degree is defined that can encompass all types of mixing mechanisms. Analysis of the dependence of the homogenous mixing degree on the averaging scale shows that, on average, the homogenous mixing degree decreases with increasing averaging scales, suggesting that apparent mixing mechanisms gradually approach from homogeneous mixing to extreme inhomogeneous mixing with increasing scales. The scale dependence can be well quantified by an exponential function, providing first attempt at developing a scale-dependent parameterization for the entrainment-mixing mechanism. The influences of three factors on the scale dependence are further examined: droplet-free filament properties (size and fraction), microphysical properties (mean volume radius and liquid water content of cloud droplet size distributions adjacent to droplet-free filaments), and relative humidity of entrained dry air. It is found that the decreasing rate of homogeneous mixing degree with increasing averaging scales becomes larger with larger droplet-free filament size and fraction, larger mean volume radius and liquid water content, or higher relative humidity. The results underscore the necessity and possibility of considering averaging scale in representation of entrainment-mixing processes in atmospheric models.

54 ENVIRONMENTAL SCIENCES↗

Intensity modulated radiotherapy and 3D conformal radiotherapy for whole breast irradiation: a comparative dosimetric study and introduction of a novel qualitative index for plan evaluation, the normal tissue index

We report on a retrospective dosimetric study, comparing 3D conformal radiotherapy (3DCRT) and hybrid intensity modulated radiotherapy (hIMRT). We evaluated plans based on their planning target volume coverage, dose homogeneity, dose to organs at risk (OARs) and exposure of normal tissue to radiation. The Homogeneity Index (HI) was used to assess the dose homogeneity in the target region, and we describe a new index, the normal tissue index (NTI), to assess the dose in the normal tissue inside the tangent treatment portal. Plans were generated for 25 early-stage breast cancer patients, using a hIMRT technique. These were compared with the 3DCRT plans of the treatment previously received by the patients. Plan quality was evaluated using the HI, NTI and dose to OARs. The hIMRT technique was significantly more homogenous than the 3DCRT technique, while maintaining target coverage. The hIMRT technique was also superior at minimising the amount of tissue receiving D{sub 105%} and above (P < 0.0001). The ipsilateral lung and contralateral breast maximum were significantly lower in the hIMRT plans (P < 0.05 and P < 0.005), but the 3DCRT technique achieved a lower mean heart dose in left-sided breast cancer patients (P < 0.05). Hybrid intensity modulated radiotherapy plans achieved improved dose homogeneity compared to the 3DCRT plans and superior outcome with regard to dose to normal tissues. We propose that the addition of both HI and NTI in evaluating the quality of intensity modulated radiotherapy (IMRT) breast plans provides clinically relevant comparators which more accurately reflect the new paradigm of treatment goals and outcomes in the era of breast IMRT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Adjusting inhomogeneous daily temperature variability using wavelet analysis

A wavelet-analysis-based homogenization method (WHM) is developed for detecting and adjusting biases of variability in a daily climate observation series, which are influential in the estimation of climate extremes and relevant trends in the time series. WHM is applied to the Central England daily mean temperature series (CET, 1772–2010) and the daily mean temperature series at Henan station in mountainous western China (HNT, 1960–2008) in order to demonstrate the usefulness of the new technique. The changes of methods for calculating daily mean temperature for CET in 1878 caused significantly reduced daily variability (DV) in the subsequent sub-series of CET. The relocation of the Chinese station in 1981 to a higher mountainous site resulted in not only enhanced DV but also in weather (weekly) time-scale variability (WV) in the subsequent sub-series of HNT. The adjustments based on WHM in the present cases improve the estimates of the long-term trends of climate extremes such as hot days, cold days, heat waves, and cold surges. A few widely applied methods of homogenization such as multiple analysis of series for homogenization (MASH), higher-order moment (HOM), RHtestsV3 with quantile-matching (QM) adjustments and two-phase regression (TPR) are also applied to HNT for comparison. TPR is not aimed at improving the homogeneity of variability in the time series; MASH does not improve daily variability either; HOM improves it in a small way; and with RHtestsV3 with QM adjustments it is considerably improved, but biases remain. In contrast, WHM improves the homogeneity of the short-term variability in the time series, resulting in reasonable assessments of climate extremes and trends in the daily observations.

54 ENVIRONMENTAL SCIENCES↗