Liquid helium Dewar for one meter mirror testing

The NASA Ames Research Center has developed a baseline design for a One Meter Cryogenic Optical Test Facility (OMF) incorporating a liquid helium Dewar for cryogenic optical testing of one-meter-class mirrors, principally the Space Infrared Telescope Facility (SIRTF) primary mirror. The primary requirements for the test facility are as follows: (1) the facility must be capable of interferometrically testing any mirror, positioned face-up or face-down, with a diameter less than 1.5 meters and a radius of curvature from 1.5 to 5.5 meters; (2) the facility must achieve and maintain, for 24 hours, a mirror temperature of 4 K with a maximum radiative heat load of less than 500 mW to the mirror, using stored liquid helium and liquid nitrogen; (3) the facility must include a vibration-isolated metrology structure between the test mirror and an external interferometer, and (4) the facility must be operated by two persons and a test, starting from the mounting of a mirror to the removal of a mirror, must be conducted within one week.

Sarver, George L., III↗

Low gravity thermal stratification of liquid helium on SHOOT

Estimates of the extent and impact of thermal stratification are presented as well as predictions of the behavior of the HeI/HeII boundary. Although thermal stratification of cryogens can be problematic and lead to their inefficient use in low gravity, for SHOOT the occurrence is beneficial both during ground hold and in orbit and presents no hazards. On the ground the parasitic heat load is both reduced and more efficiently removed. In orbit the pumpdown proceeds at a much more rapid rate, allowing orbital operations to begin earlier. The thermal conductivity of the aluminum tank and the normal liquid plus cooling at the liquid/vapor interface as the vapor bubble grows are sufficient to prevent undesirably high vapor pressures in the tank.

Shirron, P. J.↗

A simplified generic cryostat thermal model for predicting cryogen mass and lifetime

This study presents a simple generic cryostat thermal model developed for predicting cryogen mass and the lifetime of cryogenic space telescopes. The model is based on a lumped parameter representation of eight nodes and over 35 conductors. The major telescope Dewar components represented as nodes are the main cryogen tank, the three vapor-cooled shields, the outer shell, barrel baffle, and the barrel baffle heat exchanger. The input to the model consists of the vapor-cooled shield, support straps and instrument cable geometry, and the cryostat heat loads from the instrument and through the aperture. The predictions from the model were compared with those from the more detailed models of IRAS, COBE, and SIRTF. Correlation of the helium flow rates of the IRAS and COBE Dewars was 12 percent above the actual flight or ground test data and for SIRTF it was less than 2 percent of the prediction from the detailed model.

Birur, G. C.↗

Blow-down analysis of helium from a cryogenic dewar

NASA is currently developing Space Shuttle-based refilling of helium using superfluid helium on-orbit transfer (SHOOT). All the critical components of SHOOT need to be developed through ground-based tests. The helium dewar is one of these components. The Dewar consists of a vacuum vessel enclosing a superinsulated tank. The space between the vacuum vessel and the liquid tank is considered a common vacuum space. In the event that the vacuum is lost, the heat transfers to the dewar and the pressure inside the dewar increases rapidly, resulting in rupture of the dewar due to excessive pressure. Therefore, an emergency vent line is required for release of helium to prevent the dewar from rupturing. The study describes a numerical model for blow-down analysis in an emergency. This qualifies the design of the emergency vent line to be adequate for the assumed heat loads to the helium dewar.

Khan, H. J.↗

Observation of enhanced thermal lensing due to near-Gaussian pump energy deposition in a laser-diode side-pumped Nd:YAG laser

The authors report operation of a laser-diode side-pumped Nd:YAG laser with a novel pumping geometry that ensures efficient conversion of pump energy into the TEM00 mode. Significant enhancement of thermally induced lensing due to the near-Gaussian energy deposition profile of the pump radiation was observed. An induced lens of approximately 3.2-m focal length was measured at average incident pump powers of only 3.2 W (corresponding to a 0.6 W heat load).

Welford, David↗

Development of the Space Station Freedom Refrigerator/Freezer and Freezer

This paper presents the current design configuration of the Space Station Freedom (SSF) Refrigerator/Freezer and Freezer (R/F and F) systems. In addition, this paper establishes the current analyses/trade study activity related to refrigeration system design and defines Environmental Control and Life Support System (ECLSS) interfaces, anticipated heat loads, maintenance approaches and safety concerns.

Zelon, Jon↗

Applied-field magnetoplasmadynamic engine developments

There are potential space exploration missions which may significantly benefit from the use of electric propulsion at power levels of hundreds of kilowatts. The applied magnetic field MPD thruster is potentially capable of efficient, high specific impulse operation in this power range. This paper describes current experimental and analytical efforts to further the development of such a thruster and presents the latest results. In particular, efforts to measure, simultaneously, the thrust developed by the archead and by the electromagnet, and to evaluate the effect of a diffuser on vacuum tank back pressure, are presented and discussed. It was found that with ammonia vapor as propellant, the vacuum tank pressure was reduced from 8 to 4.9 Pa at a power level of 80 kW. This pressure decrease is expected to become greater as the power and applied field are increased. Also, the development of a cathode/plasma interaction model for determining the heat loads to the cathode as functions of the various free stream plasma parameters is presented. This model is combined with a cathode thermal model in order to provide a complete and integrated picture of MPD thruster cathode operation. Several computational examples are used to illustrate the combined model.

Goodfellow, K. D.↗

A SINDA '85 nodal heat transfer rate calculation user subroutine

This paper describes a subroutine, GETQ, which was developed to compute the heat transfer rates through all conductors attached to a node within a SINDA '85 thermal submodel. The subroutine was written for version 2.3 of SINDA '85. Upon calling GETQ, the user supplies the submodel name and node number which the heat transfer rate computation is desired. The returned heat transfer rate values are broken down into linear, nonlinear, source and combined heat loads.

Cheston, Derrick J.↗

Spaceborne Passive Radiative Cooler

Radiative coolers are passive refrigeration devices for satellites and space probes that provide refrigeration for an infrared or other type of detector that operates at cryogenic temperatures. Typically a cooler can supply 20 mW of cooling at about 85 K, and over 500 mW of cooling at about 165 K. The exact cooler temperatures and heat loads are dependent upon the clear field of view of the cooler to space. Some features of the Arthur D. Little passive radiative cooler are given.

Mathias, S.↗

Three-dimensional analysis of the Pratt and Whitney alternate design SSME fuel turbine

The three dimensional viscous time-mean flow in the Pratt and Whitney alternate design space shuttle main engine fuel turbine is simulated using the average passage Navier-Stokes equations. The migration of secondary flows generated by upstream blade rows and their effect on the performance of downstream blade rows is studied. The present simulation confirms that the flow in this two stage turbine is highly three dimensional and dominated by the tip leakage flow. The tip leakage vortex generated by the first blade persists through the second blade and adversely affects its performance. The greatest mixing of the inlet total temperature distortion occurs in the second vane and is due to the large leakage vortex generated by the upstream rotor. It is assumed that the predominant spanwise mixing mechanism in this low aspect ratio turbine is the radial transport due to the deterministically unsteady vortical flow generated by upstream blade rows. A by-product of the analysis is accurate pressure and heat loads for all blade rows under the influence of neighboring blade rows. These aero loads are useful for advanced structural analysis of the vanes and blades.

Kirtley, K. R.↗

Efficient development and processing of thermal math models of very large space truss structures

As the spacecraft moves along the orbit, the truss members are subjected to direct and reflected solar, albedo and planetary infra-red (IR) heating rates, as well as IR heating and shadowing from other spacecraft components. This is a transient process with continuously changing heating loads and the shadowing effects. The resulting nonuniform temperature distribution may cause nonuniform thermal expansion, deflection and stress in the truss elements, truss warping and thermal distortions. There are three challenges in the thermal-structural analysis of the large truss structures. The first is the development of the thermal and structural math models, the second - model processing, and the third - the data transfer between the models. All three tasks require considerable time and computer resources to be done because of a very large number of components involved. To address these challenges a series of techniques of automated thermal math modeling and efficient processing of very large space truss structures were developed. In the process the finite element and finite difference methods are interfaced. A very substantial reduction of the quantity of computations was achieved while assuring a desired accuracy of the results. The techniques are illustrated on the thermal analysis of a segment of the Space Station main truss.

Warren, Andrew H.↗

An approach to the functional optimization of the CELSS Test Facility

An optimization of the CELSS Test Facility (CTF) subsystems and the entire CTF is necessary in order to meet strict limitations imposed on mass, volume, and power. Depending on the subsystem, other requirements must also be met. This paper shows the way to examine compatibility of requirements, to define an area of existing solutions (an operational envelope), and to find an optimal solution. The workability of the method is shown using problems of heat load on the Plant Growth Chamber, of optimization of the Vapor-Air Membrane Separation Device, and of finding a CTF configuration with minimum air pressure drop.

Yendler, Boris S.↗

CPL Materials Life Cycle Test Facility

The Capillary Pumped Loop (CPL) Materials Life Cycle Test Facility at the Goddard Space Flight Center (GSFC) will identify the operational parameters controlling the performance of a CPL over an extended period of time. The primary purpose of the facility is to investigate the long-term chemical compatibility between the anhydrous ammonia working fluid and the CPL materials of construction. Chemical reactions occurring within the system may produce non-condensable gases or particulate debris that can lead to a degradation in system performance. Small liquid samples will be drawn from the system at specific time intervals and analyzed to check for the presence of non-condensable gases. Periodic maximum and minimum heat load tests will be performed on the CPL to monitor trends in the overall system performance.

Buchko, Matthew T.↗

High-Tc thermal bridges for space-borne cryogenic infrared detectors

The potential for using high-temperature superconductive elements, screen-printed onto ceramic substrates, as thermal bridges to replace the currently employed manganin wires is studied at NASA-LaRC. Substrate selection is considered to be the most critical parameter in device production. Due to the glass-like thermal behavior of yttria-stabilized-zirconia (YSZ) and fused silica substrates, these materials are found to reduce the heat load significantly. The estimated thermal savings for superconductive leads printed onto YSZ or fused silica substrates range from 6 to 14 percent.

Wise, S. A.↗

Thermal systems design and analysis for a 10 K Sorption Cryocooler flight experiment

The design, analysis and predicted performance of the Brilliant Eyes Ten-Kelvin Sorption Cryocooler Experiment (BETSCE) is described from a thermal perspective. BETSCE is a shuttle side-wall mounted cryogenic technology demonstration experiment planned for launch in November 1994. BETSCE uses a significant amount of power (about 500 W peak) and the resultant heat must be rejected passively with radiators, as BETSCE has no access to the active cooling capability of the shuttle. It was a major challenge to design and configure the individual hardware assemblies, with their relatively large radiators, to enable them to reject their heat while satisfying numerous severe shuttle-imposed constraints. This paper is a useful case study of a small shuttle payload that needs to reject relatively high heat loads passively in a highly constrained thermal environment. The design approach described is consistent with today's era of 'faster, better, cheaper' small-scale space missions.

Bhandari, Pradeep↗

Thermal Protection System design studies for lunar crew module

The results of a study to predict aeroheating and Thermal Protection System (TPS) requirements for manned entry vehicles returning to Earth from the moon are presented. The effects of vehicle size and lunar-return strategies on the aerothermodynamic environment and TPS design were assessed. Study guidelines were based on an Apollo Command Module (CM) configuration and lunar return strategies included direct entry and aerocapture followed by Low Earth Orbit entry (LEO). Convective heating was obtained by the boundary layer integral matrix procedure (BLIMP) code, and radiative heating was computed with the QRAD program. The AESOP-STAB code and the AESOP-THERM code were used for TPS analysis for ablating materials and nonablating materials respectively. Results indicated that there was an optimum size for minimum heating and that direct entry had higher heating rates than aerocapture. Aerocapture resulted in higher heat loads and TPS weight. The TPS weight factor was 6-8 percent for all lunar return strategies, with the TPS weight being about 50 percent less than that of the original Apollo CM vehicle.

Williams, S. D.↗

Design of the solid cryogen dewar for the Near-Infrared Camera and Multi-Object Spectrometer

A multipurpose, second-generation HST instrument for imaging and spectroscopy in the 1 to 2.5 microns wavelength region is being developed. The Near-Infrared Camera Multi-Object Spectrometer (NICMOS) is unique since it is the only HST instrument operating in the NIR and cryogenically cooled. The NICMOS detector arrays are cooled to 58 K by a solid-nitrogen (SN2) dewar with a predicted lifetime of nearly five years. To obtain this long lifetime, a hybrid cooling approach using thermoelectric coolers (TECs) is employed to reduce the parasitic heat load on the SN2. The design features used to promote long life, the predicted lifetime improvements provided by the TECs, and the performance degradation in the event of TEC failure(s) are discussed.

Oonk, Rodney L.↗

Analysis and design of an ultrahigh temperature hydrogen-fueled MHD generator

A coupled gas dynamics/radiative heat transfer analysis of partially ionized hydrogen, in local thermodynamic equilibrium, flowing through an ultrahigh temperature (10,000-20,000 K) magnetohydrodynamic (MHD) generator is performed. Gas dynamics are modeled by a set of quasi-one-dimensional, nonlinear differential equations which account for friction, convective and radiative heat transfer, and the interaction between the ionized gas and applied magnetic field. Radiative heat transfer is modeled using nongray, absorbing-emitting 2D and 3D P-1 approximations which permit an arbitrary variation of the spectral absorption coefficient with frequency. Gas dynamics and radiative heat transfer are coupled through the energy equation and through the temperature- and density-dependent absorption coefficient. The resulting nonlinear elliptic problem is solved by iterative methods. Design of such MHD generators as onboard, open-cycle, electric power supplies for a particular advanced airbreathing propulsion concept produced an efficient and compact 128-MWe generator characterized by an extraction ratio of 35.5 percent, a power density of 10,500 MWe/cu m, and a specific (extracted) energy of 324 MJe/kg of hydrogen. The maximum wall heat flux and total wall heat load were 453 MW/sq m and 62 MW, respectively.

Moder, Jeffrey P.↗