Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “HEAT EFFECT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,405 records · Page 78

Local and Nonlocal Parallel Heat Transport in General Magnetic Fields

A novel approach for the study of parallel transport in magnetized plasmas is presented. The method avoids numerical pollution issues of grid-based formulations and applies to integrable and chaotic magnetic fields with local or nonlocal parallel closures. In weakly chaotic fields, the method gives the fractal structure of the devil's staircase radial temperature profile. In fully chaotic fields, the temperature exhibits self-similar spatiotemporal evolution with a stretched-exponential scaling function for local closures and an algebraically decaying one for nonlocal closures. It is shown that, for both closures, the effective radial heat transport is incompatible with the quasilinear diffusion model.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Effect of Cellular Lattices, Heat-Exchange Intensifiers, and Coolant Mixing on the Critical Power of VVER FA

The results of one stage in the development of methods for increasing the critical power of water-cooled nuclear reactors – the capacity of a reactor installation with sharp degradation of the heat exchange characteristics of the coolant (crisis of heat exchange) – are presented. This stage included experimental determination of the effect on the crisis of heat exchange of arranging heat-exchange intensifiers in FA and transverse mixing of the coolant flow, for which lattices assembled from properly shaped cellular elements where used. The FA models consisted of an assembly of 19 fuel-element simulators with a non-uniform distribution of heat emission along the length. Freon-12 was used as the coolant. The models of the FA differed by the type of intensifier lattices and the number of FA arranged along the length. The efficacy of the influence of lattices on the critical power as a result of the intensification of heat exchange and transverse mixing of the coolant was determined separately. The optimal rigging of FA with lattices was determined experimentally.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Using Remote Sensing Data and Research Results for Urban Heat Island Mitigation

This paper provides information on the characteristics of the urban heat island, research designed to provide the data needed to develop effective urban heat island reduction strategies, and the development of local working groups to develop implementation plans. As background, an overview of research results on the urban heat island phenomenon and the resultant effect on energy usage and air quality will be explored. The use of more reflective roofing materials, paving materials, tree planting, and other initiatives will be explored as a basis for strategies to mitigate urban heat islands and improve the urban environment. Current efforts to use aircraft remote sensing data in Atlanta, Baton Rouge, Sacramento, and Salt Lake City and our work with non-profit organizations designated to lead public education and strategic development efforts will be presented. Efforts to organize working groups comprised of key stakeholders, the process followed in communicating research results, and methodology for soliciting feedback and incorporating ideas into local plans, policies and decision-making will be discussed. Challenges in developing and transferring data products and research results to stakeholders will be presented. It is our ultimate goal that such efforts be integrated into plans and/or decision models that encourage sustainable development.

Estes, Maury↗

Effect of thermionic cathode heating current self-magnetic field on gaseous plasma generator characteristics

The performance capabilities of the PINK, a plasma generator with a thermionic cathode mounted in the cavity of a hollow cathode, depending for its operation on a non-self-sustained low-pressure gas discharge have been investigated. It has been shown that when a single-filament tungsten cathode 2 mm in diameter is used and the peak filament current is equal to or higher than 100 A, the self-magnetic field of the filament current significantly affects the discharge current and voltage waveforms. This effect is due to changes in the time and space distributions of the emission current density from the hot cathode. When the electron mean free path is close to the characteristic dimensions of the thermionic cathode, the synthesized plasma density distribution is nonuniform and the cathode is etched nonuniformly. The cathode lifetime in this case is 8–12 h. Using a cathode consisting of several parallel-connected tungsten filaments ∼0.8 mm in diameter moderates the effect of the self-magnetic field of the filament current and nearly doubles the cathode lifetime. The use of this type of cathode together with a discharge igniting electrode reduces the minimum operating pressure in the plasma generator to about one third of that required for the generator operation with a single-filament cathode (to 0.04 Pa)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Prevalence of Temperature Dependent Heat Capacity Changes in Protein-DNA Interactions

A large, negative {Delta}Cp of DNA binding is a thermodynamic property of the majority of sequence-specific DNA-protein interactions, and a common, but not universal property of non-sequence-specific DNA binding. In a recent study of the binding of Taq polymerase to DNA, we showed that both the full-length polymerase and its 'Klentaq' large fragment bind to primed-template DNA with significant negative heat capacities. Herein, we have extended this analysis by analyzing this data for temperature-variable heat capacity effects ({Delta}{Delta}Cp), and have similarly analyzed an additional 47 protein-DNA binding pairs from the scientific literature. Over half of the systems examined can be easily fit to a function that includes a {Delta}{Delta}Cp parameter. Of these, 90% display negative {Delta}{Delta}Cp values, with the result that the {Delta}Cp of DNA binding will become more negative with rising temperature. The results of this collective analysis have potentially significant consequences for current quantitative theories relating {Delta}Cp values to changes in accessible surface area, which rely on the assumption of temperature invariance of the {Delta}Cp of binding. Solution structural data for Klentaq polymerase demonstrate that the observed heat capacity effects are not the result of a coupled folding event.

59 BASIC BIOLOGICAL SCIENCES↗

Anomalous Hall effect in the phonon thermal conductivity of paramagnetic dielectrics

A theory of the phonon Hall effect during heat transfer in a paramagnetic dielectric discovered by Strohm et al. [Phys. Rev. 95, 155901 (2005)] is developed. The heat flux emerging in the direction perpendicular to the magnetic field and to the temperature gradient is associated with the interaction of magnetic ions with the oscillating crystal field. In crystals with an arbitrary phonon spectrum, this interaction induces elliptic polarization of phonons. On the other hand, for any type of scattering, the temperature gradient forms part of the phonon density matrix, which is nondiagonal in modes. The combined action of these factors leads to the anomalous Hall effect.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

District heating utilizing waste heat of a data center: High-temperature heat pumps

Data centers are energy-intensive facilities with substantial low-grade waste heat. High-temperature heat pumps can be critical in boosting the data center’s waste heat for district heating, improving the system-level energy efficiency of data centers, and reducing CO 2 emissions in district heating. This study built thermodynamic models to assess high-temperature heat pumps with six configurations using low global warming potential refrigerants to supply heat up to 120 °C. The heat pump configurations include single-stage or two-stage cycles with advanced components, such as internal heat exchanger, economizer, flash tank, or parallel compressor. The refrigerants include R1234ze(Z), R1233ed(E), R1224yd(Z), R600, and R600a, and R245fa is used as a reference. A case study was carried out to recover the waste heat from the Frontier high-performance computing data center and provide hot water for district heating at the US Department of Energy’s Oak Ridge National Laboratory campus. The optimized performance of high-temperature heat pumps is characterized with various effectiveness of internal heat exchangers, and the operating parameters of economizer or flash tank, as well as their combination. The results show that the configurations of two-stage cycles with internal heat exchanger + flash tank and internal heat exchanger + economizer/parallel-compressor provide the highest coefficient of performance under scenarios of the maximum allowable value and a fixed value (0.3) of the internal heat exchangers’ effectiveness, respectively. R1234ze(Z) and R600a are the most promising refrigerants, considering trade-offs between the coefficient of performance and the volumetric heating capacity. The single-stage cycle with internal heat exchanger + economizer/parallel-compressor using R1234ze(Z) is recommended for utilizing Fronter’s waste heat in district heating. A one mega-watt high-temperature heat pump will reduce 33,100–33,200 metric tons of CO2 emission annually, corresponding to 85.4 %–85.6 % of equivalent CO2 emissions from natural gas boilers. Here, this study provides good guidelines for designing and deploying high-temperature heat pumps to support sustainable data centers and decarbonize district heating in the US.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A comprehensive analysis of the crop effect on the urban-rural differences in land surface phenology

The response of land surface phenology (LSP) to the urban heat island effect (UHI) is a useful biological indicator for understanding how vegetated ecosystems will be affected by future climate warming. However, vegetation cover in rural areas is often dominated by cultivated land, whose phenological timing is considerably influenced by agricultural managements (e.g., timing of sowing and harvesting), leading to biased conclusions derived from the urban-rural LSP differences. To demonstrate this problem, we investigated the crop influence on the phenological response to a warmer environment resulting from the UHI effect. We partitioned cities in the United States into cultivated and non-cultivated categories according to the proportion of crops in rural areas. We then built continuous buffer zones starting from the urban boundary to explore the urban-rural LSP differences considering the UHI effect on them. In this work, the results suggest crop inclusion is likely to lead to >14 days of urban-rural differences at both the start of the season (SOS) and the end of the season (EOS) between cultivated and non-cultivated cities. The temperature sensitivity (ST) of SOS is overestimated by approximately 2.7 days/°C, whereas the EOS is underestimated by 3.6 days/°C. Removing crop-dominated pixels (i.e., above 50 %) can minimize the influence of crop planting/harvesting on LSP and derive reliable results. We, therefore, suggest explicit consideration of crop impacts in future studies of phenological differences between urban and rural areas and the UHI effect on LSP in urban domains, as presented by this comprehensive study.

54 ENVIRONMENTAL SCIENCES↗

Effects of dust on the heating of Mars' surface and atmosphere

An analysis performed to determine the effect dust particles suspended in Mars' atmosphere have on the radiation reaching the surface both directly and scattered by the dust is described. Additionally, the fraction of incident sunlight directly absorbed by the atmospheric dust is computed. These calculations are done for ranges of dust opacity, incidence angle, surface albedo, and dust albedo, representative of the conditions on Mars. The effect of atmospheric dust on the Bond albedo is discussed. It is shown that direct heating of the atmosphere by dust absorption of solar radiation is adequate to explain Mars' south polar spring temperature inversion. Under most circumstances the presence of dust in Mars' atmosphere produces a lowering of the average surface temperature; this is probably the cause of the anomalously slow south polar cap retreat of 1977. Explicit forms for both the surface heating and the atmospheric heating as a function of the dust opacity, incidence angle, surface albedo and dust albedo are given.

Davies, D. W.↗

Investigating the Impacts of Land Use Change on Urban Heat and Vulnerability in Cali, Columbia

The urban heat island effect (UHI) is an environmental phenomenon where cities experience higher temperatures than rural areas due to increased pavement and decreased cooling from vegetation. Approximately 76% of people in Colombia live in urban areas, and the city of Santiago de Cali is facing UHI challenges exacerbated by land use change. Wetlands and forests formerly surrounded the city but were replaced by development and agriculture. The Colombian municipal government agency Departamento Administrativo de Gestión del Medio Ambiente and the community organization Fundacion Dinamizadores Ambientales partnered with NASA DEVELOP to evaluate communities in Cali most vulnerable to urban heat. This project illustrated the utility of using NASA Earth observations to evaluate the relationship between land use, temperature, and social factors in Cali, Colombia between 2013 and 2023. The team used Landsat 7 Enhanced Thematic Mapper Plus (ETM+), Landsat 8 Operational Land Imager (OLI) and Thermal Infrared Sensor (TIRS), and Landsat 9 OLI-2/TIRS-2 to generate land surface temperature (LST), normalized difference vegetation index (NDVI), and albedo maps in Google Earth Engine. Heavy cloud cover limited the accuracy of the LST but incorporating up to three satellites for a median image reduced potential errors. Through further analysis in ArcGIS Pro, the team classified land use change using a deep learning model and found that LST was significantly higher in urban areas than in wetlands or forests. Using R studio, the team ran a principal component analysis to determine which social factors had the strongest correlation with LST. The team found that health care and green space access were negatively correlated, and Afro-Colombian ethnicity was positively correlated with LST. With awareness of the most impacted and vulnerable regions, the partner organizations can work to prioritize green space establishment in those areas to reduce the impacts of urban heat. Addressing the urban heat island effect will reduce environmental justice concerns within the city and improve overall health, air, and water quality for those who live there.

Brenna Bruffey↗

Multi-Scale Thermal Analysis for Design of SiC-Based Medium Voltage Motor Drive: Preprint

This paper describes a multi-scale thermal analysis approach for the design of an air-cooled 1.7-kV SiC MOSFET-based medium-voltage variable-speed motor drive. The National Renewable Energy Laboratory supported the project objectives by providing thermal management design support to the project partner The Ohio State University (OSU). The scope of the models and limited resources required efficient and flexible thermal models to be developed. Two modeling techniques are described that significantly reduced model run time and enabled more complex models to be run faster while retaining needed accuracy. The first technique uses the effectiveness-NTU method to extract convection boundary conditions from a computational fluid dynamics (CFD) model that can be applied to a fast-running finite element analysis model. The second is a porous media technique that enables system-level CFD simulations that incorporate effects from heat exchangers (e.g., pin fin heat sinks) that run in a fraction of the time required for fully resolved CFD simulations. The multi-scale approach to the thermal analysis enabled fast and accurate simulation for the converter design ranging from the die level up to the full system with 36 submodules. The modeling results were validated against experimental data from system tests performed by OSU.

DIRECT ENERGY CONVERSION↗

New insights into fuel blending effects: Intermolecular chemical kinetic interactions affecting autoignition times and intermediate-temperature heat release

Fuel blending effects on chemically-dominated fuel properties, such as gasoline anti-knock quality, are influenced by fundamental chemical kinetic interactions between the blending agent and the base fuel. Historically, quantification of such interactions has focused on changes to the radical pool, including $\dot{O}$H and HO 2 , while intermolecular interactions pertaining to carbonated, non-fuel-specific intermediates are typically overlooked. In this regard, this work aims to derive new insight into intermolecular chemical kinetic interactions that are intrinsic to fuel blending effects via a case study on blends of 0–30% ethanol (by volume) into FGF-LLNL (a multi-component gasoline surrogate for FACE-F research gasoline) using a rapid compression machine at a diluted/stoichiometric fuel loading, compressed pressure of 40 bar and low- to intermediate-temperature regimes that are representative of boosted SI engine operation. Ethanol blending effects on the intermediate temperature heat release (ITHR) of FGF-LLNL are characterized using experimental measurements, where ethanol is found to promote the extent of ITHR and suppress the transition from ITHR to main ignition. Chemical kinetic modeling is undertaken using a recently updated gasoline surrogate model. Sensitivity analyses on ITHR characteristics further corroborate the ethanol blending effects, and highlight the significant dependence of ITHR on both fuel-specific and non-fuel-specific reactions. An approach allowing comprehensive characterization of the complex intermolecular chemical kinetic interactions between constitutes in a fuel blend is then proposed. Application of the approach to FGF-LLNL/E0–E30 reveals that ethanol perturbs the heat release and autoignition characteristics of FGF-LLNL not only by directly changing the $\dot{O}$H and HO 2 radical pools via fuel-specific reactions, but also through intermolecular interactions where participating intermediates can be produced and consumed by various sub-chemistries. Disabling the intermolecular interactions in carbonated species between ethanol and FGF-LLNL sub-chemistries leads to somewhat slower ITHR evolution and lower ignition reactivity. The role of the individual intermolecular interaction is also characterized using the proposed approach. Lastly, implications of intermolecular interactions for future studies that aim to improve model performance are highlighted, where it is found that further investigations on the core C0-C4 chemistry are needed for developing highly accurate chemistry models for complex fuel blends.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Assessing Urban Heat in the Cincinnati and Covington Area to Inform Local Decision-Makers and Environmental Justice Initiatives

The Urban Heat Island effect is a phenomenon characterized by urban areas experiencing temperatures that are, on average, warmer than surrounding suburban and rural regions. Urban Heat Islands are fueled by expansive impervious surfaces, vehicle emissions, and insufficient urban green space. Densely populated urban centers like the Cincinnati, Ohio and Covington, Kentucky area can experience negative health impacts due to the Urban Heat Island. NASA DEVELOP partnered with Groundwork USA and Groundwork Ohio River Valley to combine environmental education and outreach with technical capacity building in NASA Earth observations. The DEVELOP team used Landsat 5 TM and ISS ECOSTRESS to calculate daytime and nighttime land surface temperature anomalies. The team found that the Cincinnati and Covington area was 8.32°F warmer during the day and 4.97°F warmer at night compared to non-urban areas. The team also ran the Natural Capital Project InVEST Urban Cooling Model to map a heat mitigation index for the study area. The heat mitigation index models the cooling capacity of each pixel and the effect of green spaces on the pixel’s ability to mitigate heat. Results show which communities are most vulnerable to impacts of increased urban heat. The team also assessed alternative tree canopy scenarios with the InVEST model to better understand the effectiveness of potential heat mitigation strategies. Increasing tree canopy cover by 25% in urbanized land cover types was found to reduce mean temperature across the study area by 0.87°F. Combining these results with work from Groundwork’s Climate Safe Neighborhoods program highlights the relationship between extreme heat and historical-race based housing practices in the region. Results provide partners at Groundwork with refined methodologies to support future education and outreach, as well as increase future capacity to NASA Earth observations.

Celeste Gambino↗

Ni-Rich Phases in Al-12%Si-4%Cu-1.2%Mn-x%Ni Heat-Resistant Alloys and Effect of Ni-Alloying on Tensile Mechanical Properties

In this study, formation of Ni-rich phases in Al-12 wt.%Si-4 wt.%Cu-1.2 wt.%Mn-xwt.%Ni (x = 0.8, 2.0, 2.4, 3.4) alloys and their effect on high temperature strength were investigated by microstructure characterization and tensile test. Three types of Ni-rich phases are observed: δ-Al{sub 3}CuNi, γ-Al{sub 7}Cu{sub 4}Ni and ε-Al{sub 3}Ni. The amount of Ni-rich phases is increased with Ni content in the alloy. Ni-rich phases in Ni1-Ni2 alloys (x = 0.8 and 2.0, respectively) are in the form of δ-Al{sub 3}CuNi and γ-Al{sub 7}Cu{sub 4}Ni, and however, a great amount of rod-like or needle-like ε-Al{sub 3}Ni phase is observed in Ni3-Ni4 alloy (x = 2.4 and 3.4, respectively). Microstructure observation of the samples after solutionizing at 510 °C for 5 h indicates that these Ni-rich phases have good thermal stability. Ni-alloying in Al-12 wt.%Si-4 wt.%Cu-1.2 wt.%Mn alloy decreases the strength at room temperature, but proper addition of Ni can remarkably improve the strength at 350 °C and considerably and efficiently slow down the softening effect of material at high temperature stage. 0.8 wt.% Ni addition results in a considerable increase in UTS at 350 °C from 65 MPa (without Ni addition) to 97 MPa. During tensile test at room temperature, both Mn-rich phase dendrites and Ni-rich compounds are the crack originating sites of cleavage fracture. However, during tensile test at 350 °C, the Mn-rich dendrites are the sites for fracture, but Ni-rich compounds are not.

36 MATERIALS SCIENCE↗

Gas-Gap Calorimeter Sizing and Rating Tools for Heat Pipe Experimentation

Effective gas-gap calorimeter sizing and rating tools are required to design calorimeters that enable well-defined operating conditions, high cooling powers, and accurate calorimetry. The present report describes two tools utilizing Microsoft Excel and MathWorks MATLAB that enable the sizing and rating of gas-gap calorimeters with a He-Ar binary gas mixture in the gap. The Excel tools are two easy-to-use spreadsheets for calculating heat pipe operating temperature or He-Ar mole fractions given the required inputs. The MATLAB tool includes similar models with more robust solution algorithms along with sub-options for full-vacuum, static gas-gap, and forced circulation in the gas-gap. The accuracy of the developed tools were demonstrated by comparing with existing work in literature. The MATLAB tool was used for a parametric study to determine the gas-gap thickness, coolant gap thickness, coolant flow rate, and coolant inlet temperatures for the testing of a 3/4 in outer diameter heat pipe up to powers of 10 kW and temperatures of 1,000°C. The effects of heat pipe and calorimeter inner shell surface emissivities were investigated, considering the inability to control or accurately measure surface emissivities in most applications. It was found that controlling the He-Ar mole fractions provides a wide operating range for gas-gap thicknesses around ~ 0.042--0.090 in (~ 1.07--2.29 mm) for a surface emissivity range of 0.4--0.8, since conduction heat transfer is a significant fraction of the heat transfer across the gas-gap. In addition, it was found that turbulent flow in the coolant gap is needed at high input powers to prevent shell temperatures from approaching the boiling temperature of the water coolant. The parametric study resulted in choosing stainless steel tubes with an outer diameter and thickness of 1 x 0.065 in as the inner shell, and a 1-1/2 x 0.156 in as the outer shell of the calorimeter. Overall, this report presents the necessary information for the sizing and rating of gas-gap calorimeters with He-Ar mixtures for the testing of high-temperature heat pipes (~ 500--1,000°C).

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

A knowledge gap analysis for transient CHF prediction within RELAP5-3D

Here we compare several experimental pool and flow boiling critical heat flux experiments with corresponding computational models developed with RELAP5-3D. Encompassed within this paper are several sensitivity analyses for the boiling heat transfer correlations, critical heat flux (CHF) prediction within RELAP5-3D and the thermal properties of the cladding for experiments in the Transient Reactor Test Loop (TRTL) and Transient Reactor Test (TREAT) facilities. The sensitivity analyses were consistent in determining that there is a large contribution from the critical heat flux multiplier which in this application, accounts for the effects of power transient critical heat flux. Comparison to experimental results of both the TREAT CHF-SERTTA experimental campaign and a University of New Mexico (UNM) pool boiling experimental campaign demonstrate both the under-prediction of transient CHF and nucleate boiling heat transfer. To address the gaps in knowledge regarding the transient heating effect for both boiling heat transfer and CHF prediction, we present an experimental test matrix for the TRTL facility that will isolate the power transient effect under PWR relevant operational conditions. The test matrix will incorporate 6 power pulses with a constant energy deposition and a timescale that spans over several orders of magnitude, including a steady state test with an exponential period of 10 s.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗