Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Germanium”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,405 records · Page 78

Optical Properties of Semiconductor-Metal Composite Thin Films in the Infrared Region

Germanium:Silver (Ge:Ag) composite thin films having different concentrations of Ag, ranging from 7% to 40% have been prepared by dc co-sputtering of Ge an Ag and the films' surface morphology and optical properties have been characterized using transmission electron microscopy (TEM) and infrared spectrophotometry. It is seen that while the films containing lower concentrations of Ag have island-like morphology (i.e. Ag particles distributed in a Ge matrix), the higher metallic concentration films tend to have symmetric distribution of Ag and Ge.

Films Germanium Silver↗

Semiconductor- Metal Graded Index Composite Thin Films for Infrared Applications

Theoretical/experimental studies have been carried out on Germanium:Silver (Ge:Ag) graded index composite thin films, which demonstrate that graded coatings, consisting of varied concentrations of Ag with respect to the Ge film thickness, exhibit different optica properties ranging from selective infrared (IR) reflectance to broadband IR absorptance.

Inhomogeneous↗

Design of an Online Fission Gas Monitoring System for Post-irradiation Examination Heating Tests of Coated Fuel Particles for High-Temperature Gas-Cooled Reactors

A new Fission Gas Monitoring System (FGMS) has been designed at the Idaho National Laboratory (INL) for use of monitoring online fission gas-released during fuel heating tests. The FGMS will be used with the Fuel Accident Condition Simulator (FACS) at the Hot Fuels Examination Facility (HFEF) located at the Materials and Fuels Complex (MFC) within the INL campus. Preselected Advanced Gas Reactor (AGR) TRISO (Tri-isotropic) fuel compacts will undergo testing to assess the fission product retention characteristics under high temperature accident conditions. The FACS furnace will heat the fuel to temperatures up to 2,000ºC in a helium atmosphere. Released fission products such as Kr and Xe isotopes will be transported downstream to the FGMS where they will accumulate in cryogenically cooledcollection traps and monitored with High Purity Germanium (HPGe) detectors during the heating process. Special INL developed software will be used to monitor the accumulated fission products and will report data in near real-time. These data will then be reported in a form that can be readily available to the INL reporting database. This paper describes the details of the FGMS design, the control and acqusition software, system calibration, and the expected performance of the FGMS. Preliminary online data may be available for presentation at the High Temperature Reactor (HTR) conference.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Random selection as a confidence building tool

Any verification measurement performed on potentially classified nuclear material must satisfy two seemingly contradictory constraints. First and foremost, no classified information can be released. At the same time, the monitoring party must have confidence in the veracity of the measurement. The first concern can be addressed by performing the measurements within the host facility using instruments under the host's control. Because the data output in this measurement scenario is also under host control, it is difficult for the monitoring party to have confidence in that data. One technique for addressing this difficulty is random selection. The concept of random selection can be thought of as four steps: (1) The host presents several 'identical' copies of a component or system to the monitor. (2) One (or more) of these copies is randomly chosen by the monitors for use in the measurement system. (3) Similarly, one or more is randomly chosen to be validated further at a later date in a monitor-controlled facility. (4) Because the two components or systems are identical, validation of the 'validation copy' is equivalent to validation of the measurement system. This procedure sounds straightforward, but effective application may be quite difficult. Although random selection is often viewed as a panacea for confidence building, the amount of confidence generated depends on the monitor's continuity of knowledge for both validation and measurement systems. In this presentation, we will discuss the random selection technique, as well as where and how this technique might be applied to generate maximum confidence. In addition, we will discuss the role of modular measurement-system design in facilitating random selection and describe a simple modular measurement system incorporating six small {sup 3}He neutron detectors and a single high-purity germanium gamma detector.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

High-resolution microcalorimeter detectors as a tool in the future of nuclear safeguards

New measurements are presented from the LANL-NIST microcalorimeter array for two standard plutonium sources. The results demonstrate substantially smaller error bars obtained from the spectral analysis program FRAM. Some areas of improvement to the analysis technique have been identified, indicating that the micro calorimeter results can be improved upon. These results support the viability of a device for performing real nuclear safeguards measurements in the near future. The challenge of providing reliably accurate and precise data is a critical component of any safeguards initiative. In the realm of nuclear safeguards, this is an especially daunting task since inaccurate and/or imprecise data could have very serious international consequences. As such, there is a constant drive within the community to establish better measurement and analysis techniques in order to further reduce the associated errors and uncertainties. Even with todays state of the art equipment, measurement uncertainties can extend to several significant quantities worth of material over a relatively modest period of time. Furthermore, there is a strong desire for improved nondestructive analysis techniques in order to reduce both the cost, turnover rate, and inconvenience of destructive analyses. One promising new technology that may help to realize these goals is that of gamma-ray microcalorimeter detectors. The hallmark quality of this new technique is the ability to achieve energy resolution nearly an order of magnitude better than typical planar high-purity germanium (HPGe) detectors. Such an improvement may help reduce uncertainties associated with, for instance, plutonium isotopics or uranium enrichment measurements. This may, in turn, help to reduce uncertainties in total plutonium and/or uranium content in a given sample without the need for destructive analysis. In this paper, we will describe this new detector technology as well as some recent measurements carried out with the LANL-NIST gamma-ray microcalorimeter ({micro}cal) array. Discussion will focus on the capabilities of this technology as well as the progress toward a practical measurement device.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Development of a New Analysis Tool for Evaluating and Correcting for Weather Conditions that Constrain Radiation Portal Monitor Performance

Researchers at Oak Ridge National Laboratory (ORNL) developed the Adaptable, Multiplatform, Real-Time Analysis Package (AMRAP) for the continuous measurement of environmental radionuclide decay. AMRAP is a completely open source visualization and analysis package capable of combining a variety of data streams into an array of real-time plots. Once acquired, data streams are analyzed to store static images and extract data based on previously defined thresholds. AMRAP is currently used at ORNL to combine data streams from an Ortec Detective high-purity germanium (HPGe) detector, a TSA Systems radiation portal monitor (RPM), and an Orion weather station. The combined data are used to study the rain-induced increase in RPM background radiation levels. RPMs experience an increase in background radiation during precipitation due to the deposition of atmospheric radionuclides on the ground. Using AMRAP results in a real-time analysis workstation specifically dedicated to the study of RPM background radiation levels. By means of an editable library of common inputs, AMRAP is adaptable to remote monitoring applications that would benefit from the real-time visualization and analysis of radiation measurements. To study rain-induced increases in background radiation levels observed in radiation portal monitors (RPMs), researchers at Oak Ridge National Laboratory (ORNL) developed a software package that allows data with different formats to be analyzed and plotted in near real time. The Adaptable, Multiplatform, Real-Time Analysis Package (AMRAP) was developed to operate in the background and capture plots of important data based on previously defined thresholds. After executing AMRAP, segments of a data stream can be captured without additional post-processing. AMRAP can also display previously recorded data to facilitate a detailed offline analysis. Without access to these capabilities in a single software package, analyzing multiple continuously recorded data streams with different formats is impractical. Commercially available acquisition software packages record and analyze radiation measurements but are not designed to perform real-time analysis in conjunction with data from other vendors. The lack of collaboration between vendors is problematic when research requires different data streams to be correlated in time and immediately analyzed. AMRAP was specifically developed to provide a solution to this problem. AMRAP is a completely open source visualization and analysis package capable of plotting and analyzing data from different vendors in near real time.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗