Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Generation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,405 records · Page 78

Performance of a Half-Heusler Thermoelectric Generator for Automotive Application

Thermoelectric generators (TEGs) have been researched and developed for harvesting energy from otherwise wasted heat. For automotive applications this will most likely involve using internal combustion engine exhaust as the heat source, with the TEG positioned after the catalyst system. Applications to exhaust gas recirculation systems and compressed air coolers have also been suggested. A thermoelectric generator based on half-Heusler thermoelectric materials was developed, engineered, and fabricated, targeting a gasoline passenger sedan application. This generator was installed on a gasoline engine exhaust system in a dynamometer cell, and positioned immediately downstream of the closecoupled three-way catalyst. The generator was characterized using a matrix of steady-state conditions representing the important portions of the engine map. Detailed performance results are presented. Measurements indicate the generator can produces over 300 W of power with 900 °C exhaust at relatively high flow rates, but less than 50 W when the exhaust is 600 °C and at lower flow rates. The latter condition is typical of standard test cycles and most driving scenarios.

33 ADVANCED PROPULSION SYSTEMS↗

Simulation of wind and solar energy generation over California with E3SM SCREAM regionally refined models at 3.25 km and 800 m resolutions

This study presents wind and solar power generation estimates derived from the US Department of Energy’s Simple Cloud-Resolving E3SM Atmosphere Model (SCREAM) Regionally Refined Models (RRM) over California at 3.25 km and 800 m horizontal resolutions, using the Python wrapper for the System Advisor Model (PySAM). The resulting wind and solar generation estimates are compared to monthly capacity factors reported to the Energy Information Administration (EIA), High-Resolution Rapid Refresh (HRRR, 3 km resolution) forecast model, and E3SM North American regionally refined model (NARRM, 25 km resolution). We systematically assess the impacts of generation modeling assumptions, meteorological models, and horizontal resolution. Results show that resolution plays a dominant role for wind energy: increasing from 25 to 3.25 km brings qualitative and quantitative improvements, most notably by resolving the phase error in the seasonal cycle found in coarser simulations. However, further refinement to 800 m offers minimal gains. SCREAM performs better than HRRR for solar power generation in single- and dual-axis tracking systems, likely due to more accurate surface radiation. The sensitivity of PySAM to system configuration, particularly for axis-tracking modeling in photovoltaics, is also highlighted. Overall, SCREAM-RRM shows strong potential for high-resolution energy assessments, with future progress depending on more in situ observations and clearer quantification of uncertainties in generation modeling.

Geosciences↗

Integrated engine generator for aircraft secondary power

An integrated engine-generator for aircraft secondary power generation is described. The concept consists of an electric generator located inside a turbojet or turbofan engine and both concentric with and driven by one of the main engine shafts. The electric power conversion equipment and generator controls are located in the aircraft. When properly rated, the generator serves as an engine starter as well as a source of electric power. This configuration reduces or eliminates the need for an external gear box on the engine and permits reduction in the nacelle diameter.

Secunde, R. R.↗

A flight investigation of the trailing vortices generated by a jumbo jet transport

A flight investigation has been conducted to study the velocity and persistence characteristics of the trailing vortices generated by a jumbo jet transport. The investigation showed that the tangential velocities were initially higher for vortices generated with the flaps up and that they persisted for longer distances behind the aircraft than those generated with the flaps down. The core radii with flaps down appeared to be generally larger than those with flaps up. The vertical locations of the vortices behind the generating aircraft varied from several hundred meters below the generating aircraft flight path at long ranges up to, and occasionally above, the flight path at short and moderate ranges.

Verstynen, H. A., Jr.↗

The correlation structure of several popular pseudorandom number generators

One of the desirable properties of a pseudorandom number generator is that the sequence of numbers it generates should have very low autocorrelation for all shifts except for zero shift and those that are multiples of its cycle length. Due to the simple methods of constructing random numbers, the ideal is often not quite fulfilled. A simple method of examining any random generator for previously unsuspected regularities is discussed. Once they are discovered it is often easy to derive the mathematical relationships, which describe the mathematical relationships, which describe the regular behavior. As examples, it is shown that high correlation exists in mixed and multiplicative congruential random number generators and prime moduli Lehmer generators for shifts a fraction of their cycle lengths.

Neuman, F.↗

Integrated engine-generator for aircraft secondary power.

The integrated engine-generator concept consists of an electric generator located inside a turbojet or turbofan engine and both concentric with and driven by one of the main engine shafts. The electric power-conversion equipment and generator controls are conveniently located in the aircraft. When properly rated, the generator serves as an engine starter as well as a source of electric power. The available generating capacity permits use of electrically driven engine accessories. This reduces or eliminates the need for an external gearbox on the engine, thereby simplifying the engine and nacelle assembly and increasing aircraft design flexibility. The nacelle diameter can then be decreased, resulting in less aerodynamic drag and reduced takeoff gross weight.

Secunde, R. R.↗

Performance testing of a Transit generator at JPL.

A Transit type thermoelectric generator, serial number QM-III, assembled with lightweight Isotec type thermoelectric panels, has been placed on test at the Jet Propulsion Laboratory. In its exterior appearance and main constructive features, generator QM-III is similar to the generator which was flown on the Transit satellite, launched into circular polar orbit on Sept. 2, 1972. The main difference between the flight generator and QM-III is that the flight hardware is heated by radioisotope decay, while QM-III is an ETG and is assembled with three different types of thermoelectric panels. The paper describes the generator and test equipment used and presents the results of the tests performed to date.

Rouklove, P.↗

Economic considerations of utilizing small wind generators

The economic feasibility of small wind generators is compared to that of solar cells, primary batteries, thermoelectric generators, and engine generators. It is shown that small wind generator plants offer an attractive alternative to primary battery systems and constantly running engines to generate power in remote areas. The limitation is an annual average wind velocity of at least 9 to 10 mph. Presently available units are most useful in the average load range of 10 to 1000 watts.

Dodge, R.↗

Performance of vortex generators in a Mach 2.5 low-bleed full scale 45-percent-internal-contraction axisymmetric inlet

Steady-state and dynamic flow characteristics associated with two sets of vortex generators having different mixing criteria were determined. The inlet performance with and without these vortex generators is presented. The vortex generators were successful in eliminating separation, increasing area-weighted total pressure recovery, and decreasing distortion. Transmission times obtained from cross-correlations of the wall static pressures and the diffuser exit total pressure showed no effect of the upstream flow characteristics on the diffuser exit pressures when generators were used. Without generators, separation occurred and the upstream pressure characteristics had immediate effects on the diffuser exit pressure characteristics.

Neumann, H. E.↗

Wind Tunnel Generation of Sinusoidal Lateral and Longitudinal Gusts by Circulation of Twin Parallel Airfoils

A gust generator capable of producing sinusoidal lateral and longitudinal gusts was developed for the purpose of studying the gust response of a model rotor-propeller in a wind tunnel. The gust generator utilized harmonic circulation control of twin parallel airfoils to achieve the harmonic lift variation required for gust generation. The gust generator design, construction, and testing is described. Typical test results are presented in the form of lateral and longitudinal gust perturbation velocities as a function of generator reduced frequency.

Ham, N. D.↗

Investigation of a catalytic gas generator for the Space Shuttle APU

An investigation was conducted to establish the capability of a monopropellant hydrazine catalytic gas generator to meet the requirements specified for the Space Shuttle APU. Detailed analytical and experimental studies were conducted on potential problem areas including long-term nitriding effects on materials, design variables affecting catalyst life, vehicle vibration effects, and catalyst oxidation/contamination. A full-scale gas generator, designed to operate at a chamber pressure of 750 psia and a flow rate of 0.36 lbm/sec, was fabricated and subjected to three separate life test series. The objective of the first test series was to demonstrate the capability of the gas generator to successfully complete 20 simulated Space Shuttle missions in steady-state operation. The gas generator was then refurbished and subjected to a second series of tests to demonstrate the pulse-mode capability of the gas generator during 20 simulated missions. The third series of tests was conducted with a refurbished reactor to further demonstrate pulse-mode capability with a modified catalyst bed.

Emmons, D. L.↗

Generation of ultraviolet and vacuum ultraviolet radiation

The paper describes the use of nonlinear optical techniques for the generation of coherent radiation at ultraviolet, vacuum ultraviolet, and soft X-ray wavelengths. Mixtures of metal vapors and inert gases, and other mixed gas systems, allow generation to regions of the spectrum where nonlinear optical crystals are opaque; and also allow generations at high incident power and energy densities. Progress is reported on programs aimed at efficient conversion from 1.064 microns to 3547 A, and from 3547 A to 1182 A. To date, the shortest wavelength generated by this technique is 887 A. Theoretical considerations indicate that generation into the soft X-ray region should be possible. Using 1182 A radiation, a holographic grating with a fringe spacing of 836 A has been constructed and examined on an electron microscope.

Harris, S. E.↗

Harmonic generation at high field strengths - Frequency shifts and saturation phenomena

Optical harmonic generation and mixing in the gas phase has been proposed as a technique for the generation of coherent radiation in the vacuum ultraviolet and soft X-ray spectral region. At the high field strengths required by these processes the interaction between atoms and the electromagnetic field shows intensity-dependent resonances. In this paper we modify harmonic generation theory to include the effect of these frequency shifts. Closed-form expressions for generated dipole moment, absorption probability, and coherence length are presented. The most important consequences of frequency shifts on resonantly enhanced processes are that the pump laser must be tuned away from the small-field resonance frequency, that the conversion efficiency may saturate, and that the dispersion of the medium may change sign. As an example, the generation of 198-A radiation by a five-photon mixing process in Li(+) is considered.

Stappaerts, E. A.↗

Autocorrelation peaks in congruential pseudorandom number generators

The complete correlation structure of several congruential pseudorandom number generators (PRNG) of the same type and small cycle length was studied to deal with the problem of congruential PRNG almost repeating themselves at intervals smaller than their cycle lengths, during simulation of bandpass filtered normal random noise. Maximum period multiplicative and mixed congruential generators were studied, with inferences drawn from examination of several tractable members of a class of random number generators, and moduli from 2 to the 5th power to 2 to the 9th power. High correlation is shown to exist in mixed and multiplicative congruential random number generators and prime moduli Lehmer generators for shifts a fraction of their cycle length. The random noise sequences in question are required when simulating electrical noise, air turbulence, or time variation of wind parameters.

Neuman, F.↗

Future trends in electrical energy generation economics in the United States

Developments related to the economics of coal-fired systems in the U.S. are mainly considered. The historical background of the U.S. electric generation industry is examined and the U.S. electrical generation characteristics in the year 1975 are considered. It is pointed out that coal-fired power plants are presently the largest source of electrical energy generation in the U.S. Questions concerning the availability and quality of coal are investigated. Currently there are plans for converting some 50 large oil and gas-fired generating plants to coal, and it is expected that coal will be the fuel used in almost all fossil-fired base load additions to generating capacity. Aspects of advanced energy conversion from coal are discussed, taking into account the performance and economic potential of the energy conversion systems.

Schmitt, R. W.↗

A source array for generating higher order acoustic modes in circular ducts

A unique source array has been developed for the generation of both spinning and non-spinning higher order modes in a circular duct. The array consists of two concentric rings of sources. Through individual control of the response of each element, the array provided phase and amplitude control in the radial as well as circumferential directions. Radial modes shapes were measured in a 12-inch diameter anechoically-terminated hollow duct. These modes could be generated at their cut-off frequency and throughout a frequency range extending to the cut-off frequency for the next higher order radial mode. Comparisons are given between theory and experiment for the generation of specific modes. The radial dependence of the measured mode shapes was enhanced considerably by the design of this array. The results indicate a significant improvement over previous mode generation mechanisms. The contamination of the generated mode by additional spurious modes is also considered for variations between individual elements within the source array.

Wyerman, B. R.↗

Coupled generator and combustor performance calculations for potential early commercial MHD power plants

A parametric study of the performance of the MHD generator and combustor components of potential early commercial open-cycle MHD/steam power plants is presented. Consideration is given to the effects of air heater system concept, MHD combustor type, coal type, thermal input power, oxygen enrichment of the combustion, subsonic and supersonic generator flow and magnetic field strength on coupled generator and combustor performance. The best performance is found to be attained with a 3000 F, indirectly fired air heater, no oxygen enrichment, Illinois no. 6 coal, a two-stage cyclone combustor with 85% slag rejection, a subsonic generator, and a magnetic field configuration yielding a constant transverse electric field of 4 kV/m. Results indicate that optimum net MHD generator power is generally compressor-power-limited rather than electric-stress-limited, with optimum net power a relatively weak function of operating pressure.

Dellinger, T. C.↗

Power processing and control requirements of dispersed solar thermal electric generation systems

Power Processing and Control requirements of Dispersed Receiver Solar Thermal Electric Generation Systems are presented. Kinematic Stirling Engines, Brayton Engines and Rankine Engines are considered as prime movers. Various types of generators are considered for ac and dc link generations. It is found that ac-ac Power Conversion is not suitable for implementation at this time. It is also found that ac-dc-ac Power Conversion with a large central inverter is more efficient than ac-dc-ac Power Conversion using small dispersed inverters. Ac-link solar thermal electric plants face potential stability and synchronization problems. Research and development efforts are needed in improving component performance characteristics and generation efficiency to make Solar Thermal Electric Generation economically attractive.

Das, R. L.↗