Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Focuses”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,405 records · Page 78

Using Focused Regression for Accurate Time-Constrained Scaling of Scientific Applications

Many large-scale clusters now have hundreds of thousands of processors, and processor counts will be over one million within a few years. Computational scientists must scale their applications to exploit these new clusters. Time-constrained scaling, which is often used, tries to hold total execution time constant while increasing the problem size along with the processor count. However, complex interactions between parameters, the processor count, and execution time complicate determining the input parameters that achieve this goal. In this paper we develop a novel gray-box, focused median prediction errors are less than 13%. regression-based approach that assists the computational scientist with maintaining constant run time on increasing processor counts. Combining application-level information from a small set of training runs, our approach allows prediction of the input parameters that result in similar per-processor execution time at larger scales. Our experimental validation across seven applications showed that median prediction errors are less than 13%.

99 GENERAL AND MISCELLANEOUS↗

Design and Performance of Focusing Lenses for Installation into Superconducting Cryomodules of a Proton Linac

The high energy sections of the Fermilab HINS R&D proton linac will utilize superconducting spoke resonator (SSR) RF cavities. These will be assembled into cryomodules with strong solenoid focusing lenses closely interleaved with the cavities. A design for lenses has been made for the lower (SSR1) and higher (SSR2) energy ranges of the SSR-section. Prototype lenses for both SSR1 and SSR2 sections have been built and the SSR1 has been tested. Shielding is needed to reduce the solenoid fringe field on the cavity wall below the 10 μT level, and a preliminary design was built and tested with the SSR1 prototype lens. We discuss the design requirements and challenges, and the results from quench testing and magnetic measurements of the SSR1 prototype lens.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Electromagnetic analysis and experimental testing of a flux focusing wind turbine magnetic gearbox

The electromagnetic design of the second stage of a 59:1 multistage magnetic gearbox for a wind turbine demonstrator is presented here. The multistage series connected magnetic gearbox is composed of a 6.45:1 first stage and 9.14:1 second stage magnetic gear. The magnetic gears utilize a flux focusing spoke type rotor typology with a unique segmented fully laminated design. The electromagnetic impact of structural design changes on the second stage gearbox is considered with respect to torque density. Severe 3-D edge effects were encountered that greatly reduced the expect torque density of the stage 2 magnetic gear. Experimental testing of the multistage magnetic gear highlight unexpected problems associated with eddy current loss and torque ripple.

17 WIND ENERGY↗

A Neural Optimizer With Decision-Focused Learning for Optimal Energy Storage Operation

Here, this article introduces a neural optimizer-based framework for optimizing battery energy storage system (BESS) control for grid services, including demand charge and energy cost reduction. By leveraging decision-focused learning (DFL), the proposed framework ensures seamless integration and adaptation, significantly enhancing control performance. A patch time-series transformer is employed for peak load forecasting, incorporating aleatoric uncertainty quantification to account for forecasting uncertainties within the decision-making process. The framework utilizes a solver-in-the-loop approach to generate optimal BESS actions, which are then used to train the neural optimizer-based agent. By co-optimizing both BESS operational modes and output power within the NN, the system achieves improved performance and robustness. After initial training, the forecasting and control models are jointly fine-tuned to account for forecasting errors, further improving decision precision and efficiency through DFL. Case studies are performed to validate the performance of the framework using multiple real-world datasets, demonstrating superior performance in monthly peak load forecasting compared to state-of-the-art models. In addition, the results are compared against existing decision-making approaches. The results demonstrate a reduction in monthly peak forecasting error by approximately 15% across various performance measures and achieve an optimization gap for BESS operation that is about three times smaller compared to existing methods.

Kim, Hyeonjin [Pacific Northwest National Laborato↗

Application of a Focused, Pulsed X-ray Beam for Total Ionizing Dose Testing of Bipolar Linear Integrated Circuits

Here, we demonstrate the utility of focused, pulsed X-rays for investigating localized total ionizing dose effects in bipolar analog integrated circuits. Using the LM139 comparator as a test vehicle, we show how the technique can be used to identify the sources of degradation as a result of irradiating different transistors of the device and how this impacts the input bias current, input offset voltage, and output voltage. The 2-D mapping of the sensitive regions of transistors is presented, where the results of localized irradiation impact the monitored operational parameters.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Tomographic Reconstruction of the Neutron Time-Energy Spectrum from a Dense Plasma Focus

A dense plasma focus (DPF) nuclear fusion device is an attractive pulsed neutron source in many applications, due to its relatively large neutron yield, produced in a short time duration. In order to design a DPF that generates neutrons within a specified time profile, or generates a neutron energy spectrum with specific properties, it is necessary to be able to characterize and model the results of the fusion process releasing the neutrons. The time-energy spectrum of fusion neutrons is an ideal quantity to use to validate multiphysics codes that simulate the pinch and fusion processes, because it is a quantity that requires the physics of each of the stages leading up to and ending in the fusion reaction to be simulated correctly. In particular, since DPF fusion neutrons are not monoenergetic -- and there can often be several fusion pinches creating neutrons -- a computer simulation matching high quality neutron spectrum measurements provides great confidence in the fidelity of the simulation. In order to make such a comparison, it is first necessary to have quality measurements from which to infer the spectrum. In this work we pose neutron spectroscopy as the classical tomographic inverse problem from neutron time of flight data at multiple distances, but enhanced by using an additional measurement of the time profile of the fusion pinch near its source and by using detector pairs set up in a geometry that allows for scatter background subtraction. The detector pairs enhance the quality of the time of flight measurements, and the additional constraint posed by the measured time profile allows for reconstructions discretized as finely as the time measurements and in energy as finely as 100 keV, without the problem being underdetermined. We present results from a Deuterium-fueled DPF at the U.S. Department of Energy's Nevada National Security Site and show that we can infer the time-energy spectrum from our measurements for both single and multi-pinch fusion reactions with equal fidelity.

Catenacci, Jared↗

Seasonal to Decadal Variability in Focused Groundwater and Contaminant Discharge along a Channelized Stream

Abstract Focused groundwater discharge to streams is problematic at contaminated sites because high fluxes can limit natural attenuation in the hyporheic zone. However, information on location, spatial evolution, and temporal persistence of springs in unlithified sediments over multiyear time scales is limited. We examine discharge at point (~1‐m) to reach (~300‐m) scales along a stream that intercepts trichloroethene and technetium‐99 plumes from a Superfund site. During 2011 to 2012, we seasonally monitored stream and spring flow and contaminant concentrations, along with probing streambed temperatures on a grid in winter and summer, building on prior monitoring during 1999 to 2002. Baseflow measured by both gauging and dye dilution generally increased with distance downstream, and stream and spring discharge varied seasonally, from minima in October to January to maxima in February to June. Thermal anomalies identified by probing occupied approximately 3% to 6% of the reach and typically coincided with visible springs or seeps. Locations of anomalies were similar to those identified in summer 2002, although some orifices disappeared and others emerged. Vertical groundwater fluxes calculated from probing tended to be less than net fluxes calculated from stream discharge, perhaps in part because the assumption of one‐dimensional, steady‐state flow in calculating point fluxes was simplistic. Maximum contaminant concentrations and fluxes decreased between 1999 to 2001 and 2011 to 2012 as a result of partial capture by an upgradient pump‐and‐treat system. Our findings confirm that springs in unlithified sediments can remain stationary within a few meters over decadal time scales, and seasonal variability in discharge can be greater than decadal variability.

Tripathi, Ganesh N.↗

Capability of focused Ar ion beam sputtering for combinatorial synthesis of metal films

The authors examined the use of focused Ar ion beam sputtering (FAIS) for combinatorial synthesis. A Langmuir probe revealed that the electron temperature and density for FAIS of metal film deposition was lower than that of other major combinatorial thin film growth techniques such as pulsed laser deposition. Combining FAIS with the combinatorial method allowed the compositional fraction of the Pt-Ru binary alloy to be systematically controlled. Pt-Ru alloy metal film grew epitaxially on ZnO substrates, and crystal structures changed from the Pt phase (cubic structure) to the Ru phase (hexagonal structure) in the Pt-Ru alloy phase diagram. The alloy film has a smooth surface, with the Ru phase, in particular, showing a clear step-and-terrace structure. The combination of FAIS and the combinatorial method has major potential for the fabrication of high quality composition-spread metal film.

36 MATERIALS SCIENCE↗

Particle-induced x-ray emission in stainless steel using 30 keV Ga{sup +} focused ion beams

Characteristic x-ray emission from a well grounded stainless steel specimen using standard 30 keV Ga{sup +} focused ion beam instrumentation is demonstrated. X-ray yields are found to be on the order of 10{sup -10} per incident ion, consistent with previous studies of low energy, high mass ion-solid interactions. X-ray yields were found to be highest for low energy transitions or low atomic number target atoms. Bremsstrahlung x-ray emission was found to be minimal, possibly increasing detectability compared with electron beam induced x-rays. Yields were also estimated to be on the order of 10{sup -11} per sputtered atom, or approximately one x-ray per sputtered monolayer. While velocity coupling between the primary ion beam and target atom electrons is not possible under these experimental conditions, it is argued that x-ray emission is, in fact, due to recoil effects of the ion-solid interaction.

74 ATOMIC AND MOLECULAR PHYSICS↗

Modular ultrahigh vacuum-compatible gas-injection system with an adjustable gas flow for focused particle beam-induced deposition

A gas-injection system (GIS) heats up a powdery substance and transports the resulting gas through a capillary into a vacuum chamber. Such a system can be used to guide a (metal)organic precursor gas very close to the focal area of an electron or ion beam, where a permanent deposit is created and adheres to the substrate. This process is known as focused particle beam-induced deposition. The authors present design principles and give construction details of a GIS suitable for ultrahigh vacuum usage. The GIS is composed of several self-contained components which can be customized rather independently. It allows for a continuously adjustable gas-flow rate. The GIS was attached to a standard scanning electron microscope (JEOL 6100) and tested with the tungsten precursor W(CO){sub 6}. The analysis of the deposits by means of atomic force microscopy and energy dispersive x-ray spectroscopy provides clear evidence that excellent gas-flow-rate stability and ensuing growth rate and metal-content reproducibility are experienced.

36 MATERIALS SCIENCE↗

Large area direct-write focused ion-beam lithography with dual-beam microscope.

The authors have investigated the performance of focused ion-beam (FIB) direct-write lithography for large area (multiple write-field) patterning in an FEI Nova Nanolab 600 dual-beam microscope. Their system is configured with a 100 nm resolution X-Y stage and a RAITH ELPHY LITHOGRAPHY control interface, with its own integrated 16 bit DAC pattern generator and software. Key issues with regard to configuration, process parameters, and procedures have been addressed. Characterization of stitching errors, pattern repeatability, and drift were performed. Offset lithography (multiple exposures with offset write fields) and in-field registration marks were evaluated for correcting stitching errors, and a test microfluidic device covering an area of 1 x 1.4 mm{sup 2} was successfully fabricated. The authors found that by using a combination of offset lithography and in-field registration mark correction methods, the stitching errors can be kept well below 100 nm. They also found that due to higher beam deflection speed provided by the electrostatic scanning in FIB systems versus the wide-spread electron-beam systems with electromagnetic scanning, FIB lithography can be just as fast as electron-beam lithography for typical mill depths down to about 200-500 nm (material dependent). This opens the door for a large suite of applications for materials where pattern transfer is difficult or impossible by reactive methods.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Large Area Microcorrals and Cavity Formation on Cantilevers using a Focused Ion Beam

We utilize focused ion beam (FIB) to explore various sputtering parameters to form large area microcorrals and cavities on cantilevers. Microcorrals were rapidly created by modifying ion beam blur and overlaps. Modification in FIB sputtering parameters affects the periodicity and shape of corral microstructure. Cantilever deflections show ion beam amorphization effects as a function of sputtered area and cantilever base cavities with or without side walls. The FIB sputtering parameters address a method for rapid creation of a cantilever tensiometer with integrated fluid storage and delivery.

54 ENVIRONMENTAL SCIENCES↗

Structural and composition investigations at delayered locations of low k integrated circuit device by gas-assisted focused ion beam

The authors report a new delayering technique – gas-assisted focused ion beam (FIB) method and its effects on the top layer materials of integrated circuit (IC) device. It demonstrates a highly efficient failure analysis with investigations on the precise location. After removing the dielectric layers under the bombardment of an ion beam, the chemical composition of the top layer was altered with the reduced oxygen content. Further energy-dispersive x-ray spectroscopy and Fourier transform infrared analysis revealed that the oxygen reduction lead to appreciable silicon suboxide formation. Our findings with structural and composition alteration of dielectric layer after FIB delayering open up a new insight avenue for the failure analysis in IC devices.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Atomic layer deposition frequency-multiplied Fresnel zone plates for hard x-rays focusing

The design and fabrication of Fresnel zone plates for hard x-ray focusing up to 25 keV photon energies with better than 50 nm imaging half-pitch resolution is reported as performed by forming an ultrananocrystalline diamond (UNCD) scaffold, subsequently coating it with atomic layer deposition (ALD) with an absorber/phase shifting material, followed by back side etching of Si to form a diamond membrane device. The scaffold is formed by chemical vapor-deposited UNCD, electron beam lithography, and deep-reactive ion etching of diamond to desired specifications. The benefits of using diamond are as follows: improved mechanical robustness to prevent collapse of high-aspect-ratio ring structures, a known high-aspect-ratio etch method, excellent radiation hardness, extremely low x-ray absorption, and significantly improved thermal/dimensional stability as compared to alternative materials. Central to the technology is the high-resolution patterning of diamond membranes at wafer scale, which was pushed to 60 nm lines and spaces etched 2.2-mu m-deep, to an aspect ratio of 36:1. The absorber growth was achieved by ALD of Ir, Pt, or W, while wafer-level processing allowed to obtain up to 121 device chips per 4 in. wafer with yields better than 60%. X-ray tests with such zone plates allowed resolving 50 nm lines and spaces, at the limit of the available resolution test structures.

36 MATERIALS SCIENCE↗

Erosion of focus rings in capacitively coupled plasma etching reactors

In plasma etching reactors, the structure surrounding the wafer, often called a focus ring (FR), plays an important role in maintaining uniform fluxes of reactants across the wafer. The FR is typically made of dielectric materials. During the plasma etching process, the sheath that forms over the wafer to accelerate ions anisotropically into the surface extends over the FR. Electrical charging of the FR modifies the sheath relative to that over the wafer. On the one hand, one wants the sheath to be uniform across the wafer-FR boundary to enable uniform fluxes to the edge of the wafer. On the other hand, maintaining a high voltage sheath over the FR will erode the FR, which is undesirable as the FR is a consumable component that must be periodically replaced in high volume manufacturing. In this work, we computationally investigated the consequences of dielectric constant ε of the FR materials on erosion of the FR. The series capacitance of the FR and its underlying structure is typically smaller than that of the wafer and its underlying structure. As a result, the FR charges quickly relative to the wafer, which then reduces the voltage across the sheath on top of the FR. The ion energy and angular distributions (IEADs) striking the FR are, therefore, generally lower in energy with a broader angular distribution. With ε = 2, the ion energies striking the middle to the outer edge of the FR are 30–180 eV, whereas for ε = 100, the ion energies are 120–380 eV. At the transition between the wafer and the FR, there is a skew in the IEAD as large as 15° that results from the difference in sheath thickness above the wafer and the FR. This skew and the erosion rate across the FR are functions of the dielectric constant of the FR material. With low ε, the FR charges quickly, less plasma is produced above the FR, and there is less voltage across the sheath that results in less FR erosion. Increasing ε of the FR produces a higher sheath voltage as well as higher ion fluxes over the FR, which increases erosion, while the skew at the edge of the wafer is less severe. Further, the material of the subsurface portion of the FR, which dominates its capacitance, is an important consideration in the design of the substrate assembly.

36 MATERIALS SCIENCE↗

Factor analysis in automated face detection: gender, occlusion, eyewear, brightness, contrast, and focus measure

Computer-based facial recognition algorithms exploit the unique characteristics of faces in images. However, in non-cooperative situations these unique characteristics are often disturbed. In this study, we examine the effect of six different factors on face detection in an unconstrained imaging environment: image brightness, image contrast, focus measure, eyewear, gender, and occlusion. The aim of this study is twofold: first, to quantify detection rates of conventional Haar cascade algorithms across these six factors; and second, to propose methods for automatically labeling datasets whose size prohibits manual labeling. First, we manually classify a uniquely challenging dataset comprising 9,688 images of passengers in vehicles acquired from a roadside camera system. Next, we quantify how each of the aforementioned factors affect face detection on this dataset. Of the six factors studied, occlusion had the most significant impact, resulting in a 54% decrease in detection rate between unoccluded and severely occluded faces in our unique dataset. Finally, we provide a methodology for data analytics of large datasets where manual labeling of the whole dataset is not possible.

Jafek, Benjamin↗

Reliable automatic alignment of tomographic projection data by passive auto-focus

Purpose: The authors present a robust algorithm that removes the blurring and double-edge artifacts in high-resolution computed tomography (CT) images that are caused by misaligned scanner components. This alleviates the time-consuming process of physically aligning hardware, which is of particular benefit if components are moved or swapped frequently. Methods: The proposed method uses the experimental data itself for calibration. A parameterized model of the scanner geometry is constructed and the parameters are varied until the sharpest 3D reconstruction is found. The concept is similar to passive auto-focus algorithms of digital optical instruments. The parameters are used to remap the projection data from the physical detector to a virtual aligned detector. This is followed by a standard reconstruction algorithm, namely the Feldkamp algorithm. Feldkamp et al.[J. Opt. Soc. Am. A 1, 612-619 (1984)]. Results: An example implementation is given for a rabbit liver specimen that was collected with a circular trajectory. The optimal parameters were determined in less computation time than that for a full reconstruction. The example serves to demonstrate that (a) sharpness is an appropriate measure for projection alignment, (b) our parameterization is sufficient to characterize misalignments for cone-beam CT, and (c) the procedure determines parameter values with sufficient precision to remove the associated artifacts. Conclusions: The algorithm is fully tested and implemented for regular use at The Australian National University micro-CT facility for both circular and helical trajectories. It can in principle be applied to more general imaging geometries and modalities. It is as robust as manual alignment but more precise since we have quantified the effect of misalignment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Photoacoustic detection and optical spectroscopy of high-intensity focused ultrasound-induced thermal lesions in biologic tissue

Purpose: The aims of this study are: (a) to investigate the capability of photoacoustic (PA) method in detecting high-intensity focused ultrasound (HIFU) treatments in muscle tissuesin vitro; and (b) to determine the optical properties of HIFU-treated and native tissues in order to assist in the interpretation of the observed contrast in PA detection of HIFU treatments. Methods: A single-element, spherically concaved HIFU transducer with a centre frequency of 1 MHz was utilized to create thermal lesions in chicken breast tissuesin vitro. To investigate the detectability of HIFU treatments photoacoustically, PA detection was performed at 720 and 845 nm on seven HIFU-treated tissue samples. Within each tissue sample, PA signals were acquired from 22 locations equally divided between two regions of interest within two volumes in tissue – a HIFU-treated volume and an untreated volume. Optical spectroscopy was then carried out on 10 HIFU-treated chicken breast specimens in the wavelength range of 500–900 nm, in 1-nm increments, using a spectrophotometer with an integrating sphere attachment. The authors’ optical spectroscopy raw data (total transmittance and diffuse reflectance) were used to obtain the optical absorption and reduced scattering coefficients of HIFU-induced thermal lesions and native tissues by employing the inverse adding-doubling method. The aforementioned interaction coefficients were subsequently used to calculate the effective attenuation coefficient and light penetration depth of HIFU-treated and native tissues in the wavelength range of 500–900 nm. Results: HIFU-treated tissues produced greater PA signals than native tissues at 720 and 845 nm. At 720 nm, the averaged ratio of the peak-to-peak PA signal amplitude of HIFU-treated tissue to that of native tissue was 3.68 ± 0.25 (mean ± standard error of the mean). At 845 nm, the averaged ratio of the peak-to-peak PA signal amplitude of HIFU-treated tissue to that of native tissue was 3.75 ± 0.26 (mean ± standard error of the mean). The authors’ spectroscopic investigation has shown that HIFU-treated tissues have a greater optical absorption and reduced scattering coefficients than native tissues in the wavelength range of 500–900 nm. In fact, at 720 and 845 nm, the ratio of the optical absorption coefficient of HIFU-treated tissues to that of native tissues was 1.13 and 1.17, respectively; on the other hand, the ratio of the reduced scattering coefficient of HIFU-treated tissues to that of native tissues was 13.22 and 14.67 at 720 and 845 nm, respectively. Consequently, HIFU-treated tissues have a higher effective attenuation coefficient and a lower light penetration depth than native tissues in the wavelength range 500–900 nm. Conclusions: Using a PA approach, HIFU-treated tissues interrogated at 720 and 845 nm optical wavelengths can be differentiated from untreated tissues. Based on the authors’ spectroscopic investigation, the authors conclude that the observed PA contrast between HIFU-induced thermal lesions and untreated tissue is due, in part, to the increase in the optical absorption coefficient, the reduced scattering coefficient and, therefore, the deposited laser energy fluence in HIFU-treated tissues.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗