Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Fluorescence”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,405 records · Page 78

Thermalization of Fluorescent Protein Exciton–Polaritons at Room Temperature

Fluorescent proteins (FPs) have recently emerged as a serious contender for realizing ultralow threshold room temperature exciton–polariton condensation and lasing. Here, this contribution investigates the thermalization of FP microcavity exciton–polaritons upon optical pumping under ambient conditions. Polariton cooling is realized using a new FP molecule, called mScarlet, coupled strongly to the optical modes in a Fabry–Pérot cavity. Interestingly, at the threshold excitation energy (fluence) of ≈9 nJ per pulse (15.6 mJ cm –2 ), an effective temperature is observed, T eff ≈ 350 ± 35 K close to the lattice temperature indicative of strongly thermalized exciton–polaritons at equilibrium. This efficient thermalization results from the interplay of radiative pumping facilitated by the energetics of the lower polariton branch and the cavity Q-factor. Direct evidence for dramatic switching from an equilibrium state into a metastable state is observed for the organic cavity polariton device at room temperature via deviation from the Maxwell–Boltzmann statistics at k || = 0 above the threshold. Thermalized polariton gases in organic systems at equilibrium hold substantial promise for designing room temperature polaritonic circuits, switches, and lattices for analog simulation.

36 MATERIALS SCIENCE↗

Micro‐ and Nanoscale Heterogeneities in Zeolite Beta as Measured by Atom Probe Tomography and Confocal Fluorescence Microscopy

Micro- and nanoscale information on the activating and deactivating coking behaviour of zeolite catalyst materials increases our current understanding of many industrially applied processes, such as the methanol-to-hydrocarbon (MTH) reaction. Atom probe tomography (APT) was used to reveal the link between framework and coke elemental distributions in 3D with sub-nanometre resolution. APT revealed 10–20 nanometre-sized Al-rich regions and short-range ordering (within nanometres) between Al atoms. With confocal fluorescence microscopy, it was found that the morphology of the zeolite crystal as well as the secondary mesoporous structures have a great effect on the microscale coke distribution throughout individual zeolite crystals over time. Additionally, a nanoscale heterogeneous distribution of carbon as residue from the MTH reaction was determined with carbon-rich areas of tens of nanometres within the zeolite crystals. Finally, a short length-scale affinity between C and Al atoms, as revealed by APT, indicates the formation of carbon-containing molecules next to the acidic sites in the zeolite.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A Fluorescence‐Based Transient Expression Assay for the Analysis of Upstream Open Reading Frames in Plants

Upstream open reading frames (uORFs) are regulatory elements present in the 5′ leaders of mRNA that can significantly impact downstream gene expression in eukaryotes. In crop engineering, editing of uORFs can provide an avenue to upregulate expression of native genes without the need to add persistent transgenic copies. Even with genome-wide methods to identify translated uORFs such as ribosome profiling, their functional characterization depends on validation through reporter gene assays and mutagenesis studies. Current screening methods for plants use luciferases or protoplasts to measure differential gene expression between wild-type and mutated transcript leaders, which requires tissue processing and/or substrate addition. Here, we present a time- and cost-efficient alternative to investigate transcript leaders by co-expression of two fluorescent proteins in Nicotiana benthamiana leaf tissue and test our assay on genes involved in photoprotection, editing of which could provide a pathway to increase CO 2 assimilation during sun–shade transitions.

Nicotiana benthamiana↗

One-Pot Hydrothermal Synthesis of Elements (B, N, P)-Doped Fluorescent Carbon Dots for Cell Labelling, Differentiation and Outgrowth of Neuronal Cells

The use of the chemically modified one-step facile hydrothermal process to develop Boron (B), Nitrogen (N), and Phosphorous (P) doped carbon dots (E@CDs) is reported on in this work. The chemical characterization of the E@CDs was systematically studied by several analytical techniques that confer doping of elements by known characteristics. The obtained E@CDs had observed very homogeneous size distribution and displayed excitation dependent fluorescence properties, and high quantum yield (QY) was measured in case of B and N doping. Excellent cell viability and good cellular uptake was observed for all E@CDs. Lastly, E@CDs were compared with pristine CDs on their effect on cell labelling, neural differentiation process and outgrowth of neurite network. By manipulating the doping of CDs, we can control the branching pattern and outgrowth of neuronal developments. The E@CDs are capable due to their photostability biocompatibility, and possible selective affinity towards nanomedicine applications.

36 MATERIALS SCIENCE↗

Benchmarking of X‐Ray Fluorescence Microscopy with Ion Beam Implanted Samples Showing Detection Sensitivity of Hundreds of Atoms

Abstract Single impurities in insulators are now often used for quantum sensors and single photon sources, while nanoscale semiconductor doping features are being constructed for electrical contacts in quantum technology devices, implying that new methods for sensitive, non‐destructive imaging of single‐ or few‐atom structures are needed. X‐ray fluorescence (XRF) can provide nanoscale imaging with chemical specificity, and features comprising as few as 100 000 atoms have been detected without any need for specialized or destructive sample preparation. Presently, the ultimate limits of sensitivity of XRF are unknown – here, gallium dopants in silicon are investigated using a high brilliance, synchrotron source collimated to a small spot. It is demonstrated that with a single‐pixel integration time of 1 s, the sensitivity is sufficient to identify a single isolated feature of only 3000 Ga impurities (a mass of just 350 zg). With increased integration (25 s), 650 impurities can be detected. The results are quantified using a calibration sample consisting of precisely controlled numbers of implanted atoms in nanometer‐sized structures. The results show that such features can now be mapped quantitatively when calibration samples are used, and suggest that, in the near future, planned upgrades to XRF facilities might achieve single‐atom sensitivity.

36 MATERIALS SCIENCE↗

High-resolution elemental mapping of human placental chorionic villi using synchrotron X-ray fluorescence spectroscopy

The placenta is the organ that mediates transport of nutrients and waste materials between mother and fetus. Synchrotron X-ray fluorescence (SXRF) microanalysis is a tool for imaging the distribution and quantity of elements in biological tissue, which can be used to study metal transport across biological membranes. Our aims were to pilot placental biopsy specimen preparation techniques that could be integrated into an ongoing epidemiology birth cohort study without harming rates of sample acquisition. We studied the effects of fixative (formalin or glutaraldehyde) and storage duration (30 days or immediate processing) on metal distribution and abundance and investigated a thaw-fixation protocol for archived specimens stored at -80° C. We measured fixative elemental composition with and without a placental biopsy via inductively coupled plasma mass spectrometry (ICP-MS) to quantify fixative-induced elemental changes. Formalin-fixed specimens showed hemolysis of erythrocytes. The glutaraldehyde-paraformaldehyde solution in HEPES buffer (GTA-HEPES) had superior anatomical preservation, avoided hemolysis, and minimized elemental loss, although some cross-linking of exogenous Zn was evident. Elemental loss from tissue stored in fixative for 1 month showed variable losses (≈ 40 % with GTA-HEPES), suggesting storage duration be controlled for. Lastly, thawing of tissue held at -80 °C in a GTA-HEPES solution provided high-quality visual images and elemental images

60 APPLIED LIFE SCIENCES↗

A Colorimetric and Fluorescent Chemosensor of Fe{sup 3+} Based on an Asymmetrical Squarylium Dye

A novel asymmetrical squarylium-dye-based dual signaling probe was synthesized and found to exhibit colorimetric and fluorescent properties on selective binding towards Fe{sup 3+} in ethanol/water (4:1, v/v) solution. The binding constant was determined to be 7.69 × 10{sup 2} M{sup –1}, and the detection limit of SQ was 9.158 × 10{sup –6} M. Most importantly, the 1:2 stoichiometry of the host-guest complexation was confirmed by Job’s method. Moreover, the high sensing ability of the receptor towards Fe{sup 3+} was also investigated by the electrochemical technique.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A Naked-Eye Visible and Fluorescence 'Turn-On' Probe for Acetylcholinesterase Assay and the Discrimination of Biothiols

We demonstrate the utility of 4-chloro-7-nitrobenzofurazan (NBD-Cl), a simple, low-cost probe, for colorimetrically and fluorescently detecting and differentiating similar thiol species, including cysteine, homocysteine, and glutathione, as well as for assaying acetylcholinesterase (AChE) activity. This assay is a potential tool for investigating thiol functions in disease and diagnosis, and for screening AChE inhibitors. We envision that this versatile probe, which is commercially available and inexpensive, will be useful for further elucidating the roles of thiols in biology and also shows applicability for analysis of AChE inhibitors in physiological samples.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Donor-Acceptor Conjugated Linear Polyenes: A Study of Excited State Intramolecular Charge Transfer, Photoisomerization and Fluorescence Probe Properties

Numerous studies of donor-acceptor conjugated linear polyenes have been carried out with the goal to understand the exact nature of the excited state electronic structure and dynamics. In this article we discuss our endeavours with regard to the excited state intramolecular charge transfer, photoisomerization and fluorescence probe properties of various donor-acceptor substituted compounds of diphenylpolyene [Ar(CH = CH){sub n}Ar] series and ethenylindoles.

74 ATOMIC AND MOLECULAR PHYSICS↗

Comparative Study of Novel Fluorescent Cyanine Nucleotides: Hybridization Analysis of Labeled PCR Products Using a Biochip

This study investigated the synthesis and substrate properties of Cy5-labeled dUTP derivatives with different substituents, linkers between the dye unit and pyrimidine heterocycle and fluorophore charges. Fluorescently labeled nucleoside triphosphates were studied as substrates using multiplex PCR with Taq and Vent (exo-) DNA polymerases, the typical representatives of the A and B polymerase families. The efficiency of nucleotide incorporation during PCR was assessed with a multi-parameter hybridization analysis using a diagnostic DNA microarray. The hybridization analysis indirectly estimates the incorporation efficiency of dye-labeled nucleotides in multiplex PCR. Our results demonstrated higher efficiencies of substrates with electrically neutral dyes than electropositive and electronegative Cy5 residues.

60 APPLIED LIFE SCIENCES↗

Selective and Sensitive Fluorescein-Benzothiazole Based Fluorescent Sensor for Zn{sup 2+} Ion in Aqueous Media

An efficient fluorescent sensor based on fluorescein-benzothiazole (FB) for Zn{sup 2+} ion was synthesized and characterized systematically. FB exhibited selective and sensitive recognition toward Zn{sup 2+} in MeCN-H{sub 2}O (v/v = 2/1) over other cations due to the spirolactam ring-opening power of Zn{sup 2+}. The complexation property of FB with Zn{sup 2+} ion was examined by {sup 1}H NMR, {sup 13}C NMR and FTIR experiments. The stoichiometric ratio of the FB-Zn{sup 2+} complex was determined from a Job plot to be 1:1. The binding constant (K{sub a}) of Zn{sup 2+} binding to FB was found to be 4.22 × 10{sup 4} M{sup − 1}, with a detection limit of 5.64 μM. In addition, the practical utility of FB was explored in the form of test strips. .

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Sensitive Fluorescent Determination of Cobalt by Microwave Assisted Synthesized TPTZ Functionalized Carbon Dots

Novel fluorescent carbon dots (CDs) for cobalt ions sensing were synthesized from 2,4,6-tris(2′-pyridyl)-s-triazine (TPTZ) and citric acid by microwave-assisted method in one pot. This sensor was water soluble, simple, sensitive and cheap. The size of the CDs was determined from transmission electron microscope image and was in the range of 10 nm. Under optimized experimental conditions, this luminescent system had stable response for Co (II) over a concentration range from 0.4 to 50 µM with a detection limit as low as 230 nM. The proposed method showed good sensitivity and selectivity with respect to interference ions. Finally, this system was used for Co (II) determination in tap water, river water and mineral water and B{sub 12} ampoule samples.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Highly Selective Detection of Cr{sup 3+} Ion with Colorimetric & Fluorescent Response Via Chemodosimetric Approach in Aqueous Medium

So far, very few numbers of chemosensors for Cr{sup 3+} ion have been reported. However, the main drawback of reported receptors are the lack of selectivity and other trivalent cations such as Fe{sup 3+}, Al{sup 3+} and anions like F{sup −} and {sup −}OAc frequently interfere with such assays. This paper present the synthesis, characterization & sensor studies of Schiff base containing naphthalene moiety which selectively detect Cr{sup 3+} ion by chemodosimetric approach. Using FT-IR, {sup 1}H NMR, {sup 13}C NMR and ESI mass spectroscopic techniques the probe was characterized. This receptor exhibit more selectivity and sensitivity towards Cr{sup 3+} than other divalent and trivalent cations like Mn{sup 2+}, Zn{sup 2+}, Co{sup 2+}, Ni{sup 2+}, Cd{sup 2+}, Cu{sup 2+}, Hg{sup 2+}, Fe{sup 3+}, and Al{sup 3+} ions. After the addition of chromium ion the receptor get change from yellow to colorless in aqueous medium. But no color change was observed on the addition of other metal ions. Using UV-Vis and PL studies, it was confirmed that the selective hydrolysis of imine group of receptor by Cr{sup 3+} ions takes place with high fluorescence enhancement that is corresponding to 1-naphthylamine. Receptor acts as selective chemodosimeter for Cr{sup 3+} ions with 2:1 stoichiometry and micro molar detection limit. This chemodosimetric approach was applied successfully for bio-imaging of HeLa cells.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Design and Synthesis of Nanosensor Based on CdSe Quantum Dots Functionalized with 8-Hydroxyquinoline: a Fluorescent Sensor for Detection of Al{sup 3+} in Aqueous Solution

A novel nanosensor based on CdSe quantum dots (QDs) capped with 8-hydroxyqunoline (HQ) was developed for Al{sup 3+} ions determination in aqueous solutions. The method is based on the fluorescence enhancement of the HQ functionalized QDs in the presence of Al{sup 3+} ions, due to the strong interaction between Al{sup 3+} and HQ. Prepared nanosensor exhibited an acceptable selectivity and sensitivity for Al{sup 3+} ions in the presence of other metal ions. Plot of Log(I/I{sub 0}) against Log[Al{sup 3+}] shows a good linearity in the range of 0.02–3.0 mM, and the method could be used for detection of Al{sup 3+} ions concentration in aqueous solutions.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Temporally and Spatially Resolved x-ray Fluorescence Measurements of in-situ Drug Concentration in Metered-Dose Inhaler Sprays

Drug concentration measurements in MDI sprays are typically performed using particle filtration or laser scattering. These techniques are ineffective in proximity to the nozzle, making it difficult to determine how factors such as nozzle design will affect the precipitation of co-solvent droplets in solution-based MDIs, and the final particle distribution. In optical measurements, scattering from the constituents is difficult to separate. We present a novel technique to directly measure drug distribution. A focused x-ray beam was used to stimulate x-ray fluorescence from the bromine in a solution containing 85% HFA, 15% ethanol co-solvent, and 1 / IPBr. Instantaneous concentration measurements were obtained with 1 ms temporal resolution and 5 spatial resolution, providing information in a region that is inaccessible to many other diagnostics. The drug remains homogeneously mixed over time, but was found to be higher at the centerline than at the periphery. This may have implications for oropharyngeal deposition in vivo. Measurements in the dynamic, turbulent region of MDIs allow us to understand the physical links between formulation, inspiration, and geometry on final particle size and distribution. This will ultimately lead to a better understanding of how MDI design can be improved to enhance respirable fraction.

fluorescence↗

Localization and kinetics of an atom in the spectral filtration of its resonance fluorescence

It is shown that spectral filtration of a significant fraction of radiation of a resonantly fluorescing atom changes its kinetics. The effect of a spectral observation event on the behavior of an atom is demonstrated by two examples: localization of an atom at its flight through a region occupied by a standing light wave and translatory dynamics of an atom at its motion along a standing light wave. In the first case, localization probabilities are calculated in the absence of spontaneous emission events and for one photoemission event. The arising distribution over the atomic momentum, which is sensitive to spectral filtration, is also calculated for one photoemission event. In the second example, it is shown that spectral filtration of spontaneous emission leads to the occurrence of an anomalous additive to the force acting on an atom in the standing-wave field.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Introducing the Planar Laser-Induced Fluorescence Technique (PLIF) to Measure Mixing Time in Gas-Stirred Ladles

The planar laser-induced fluorescence (PLIF) technique was implemented to measure mixing time in a 1/17 water model of a 200-ton ladle furnace. The results were compared to those obtained using the conventional method of pH probes. PLIF determinations were done at two different planes, and pH probe determinations were performed at two different locations. The results suggest that mixing times measured by PLIF are similar to those obtained under optimal conditions by the pH probe and that PLIF technique is more accurate and less sensitive to the location of the measurement than the pH probe method. In addition, the particle image velocimetry (PIV) technique was used to measure the effect of the immersed probe on the fluid-dynamic structure of the system. The presence of the probe affects greatly fluid dynamics and consequently the mixing behavior, which could explain the differences found in its mixing time measurements at different probe locations. This study shows the feasibility of the PLIF technique used to measure mixing time in physical models of gas-stirred ladles; it is not intrusive and allows the visualization of the mixing phenomena in a complete plane of the system.

36 MATERIALS SCIENCE↗

Fluorescence in situ hybridization in 1 mL of selective urine for the detection of upper tract urothelial carcinoma: a feasibility study

Kidney-sparing surgery of upper tract urothelial carcinoma (UTUC) requires a stringent follow-up with frequent ureteroscopies. Triage testing could reduce the number of follow-up ureteroscopies and hence minimize the invasiveness of follow-up. The use of urine-based markers for triage seems appealing but should be feasible with selective urine from outpatient cystoscopy to maximize the reduction of invasiveness. In this study, the feasibility of UroVysion{sup ®} fluorescence in situ hybridization (FISH) for the detection of UTUC in 1 mL of selective urine is investigated. Ten consecutive patients with biopsy-proven UTUC and five patients with negative diagnostic ureteroscopy findings were included in this case-control study. During ureteroscopy, 1 mL of selective urine was collected passively with a ureteral splint for Urovysion® FISH. The FISH rater was blinded to any clinical information. The results of FISH were compared to the findings of concomitantly collected selective urine cytology and the patients’ UTUC status. FISH was feasible in all samples with a sensitivity of 90% and a specificity of 80% for UTUC. In comparison, selective cytology resulted in a diagnostic yield of 87% with a sensitivity of 80% and a specificity of 67%. In conclusion, UTUC detection is feasible with FISH in 1 mL of passively collected selective urine. Thus from a technical point of view, FISH could be used as an outpatient triage test to decide if follow-up ureteroscopy is necessary after kidney-sparing surgery of UTUC. Evaluation of the diagnostic accuracy of FISH for the suggested pathway deserves further attention.

62 RADIOLOGY AND NUCLEAR MEDICINE↗