Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “FORCE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,405 records · Page 78

Source apportionments of aerosols and their direct radiative forcing and long-term trends over continental United States

Due to US air pollution regulations, aerosol and precursor emissions have decreased during recent decades, while changes in emissions in other regions of the world also influence US aerosol trends through long-range transport. We examine here the relative roles of these domestic and foreign emission changes on aerosol concentrations and direct radiative forcing (DRF) at the top of the atmosphere over the continental US. Long-term (1980-2014) trends and aerosol source apportionment are quantified in this study using a global aerosol-climate model equipped with an explicit aerosol source tagging technique. Due to US emission control policies, the annual mean near-surface concentration of particles, consisting of sulfate, black carbon, and primary organic aerosol, decreases by about –1.1 (±0.1) / –1.4 (±0.1) μg m -3 in western US and –3.3 (±0.2) / –2.9 (±0.2) μg m -3 in eastern US during 2010–2014, as compared to those in 1980–1984. Meanwhile, decreases in US emissions lead to a warming of +0.48 (±0.03) / –0.46 (±0.03) W m -2 in western US and +1.41 (±0.07) /+1.32 (±0.09) W m -2 in eastern US through changes in aerosol DRF. Increases in emissions from East Asia generally have a modest impact on US air quality, but mitigated the warming effect induced by reductions in US emissions by 25% in western US and 7% in eastern US. Thus, as US domestic aerosol and precursor emissions continue to decrease, foreign emissions may become increasingly important to radiative forcing over the US.

54 ENVIRONMENTAL SCIENCES↗

Neutral Mode Dominates the Forced Global and Regional Surface Temperature Response in the Past and Future

Abstract Using a large suite of Green's function perturbation experiments, we construct the emergent dynamical operator for surface temperature and extract the most excitable mode. The leading mode turns out to be the most dominant mode excited by the climate forcing of doubling CO 2 , alone capturing 56% of the total spatial variances of the surface temperature response. The pattern of the leading mode is partly organized by the atmospheric annular modes in both hemispheres, and further modulated by the feedbacks from ocean circulations. Though derived from a single model, the leading mode can capture the spatio‐temporal variabilities of the global mean surface temperature over the past century in both the CMIP6 model simulations and observations. Moreover, the leading mode is most efficiently excited by radiative forcings from the midlatitude bands centered around 45°N and 25°S, where most human activities take place, suggesting the potency of human influence on the climate change.

54 ENVIRONMENTAL SCIENCES↗

Representing Anthropogenic Dust From Agricultural Sources in E3SMv1: Implementation, Evaluation, and Assessment of the Radiative Forcing

Dust emissions related to anthropogenic activities (i.e., anthropogenic dust) is not represented in most global climate models and its radiative impact remains unassessed. In this study, we develop a new and physically based method to parameterize anthropogenic dust emission from agricultural sources (i.e., agricultural dust, or AD) based on the DOE's Energy Exascale Earth System Model version 1 (E3SMv1). This method relates AD emission to the crop land use fraction in the E3SMv1 land component. Major AD sources simulated by our parameterization include those over Central America, the Sahel, North India, and North China. The annual averaged AD emission with diameter less than 10 μm is 567 Tg yr −1 in present-day (year 2000), which contributes to 13.3% of total dust emission. Model evaluation against satellite and ground-based observations shows that the new parameterization can represent AD emissions and global dust cycle reasonably well. We find that the total dust emission increases by 13.1% (495 Tg yr −1 ) from 1850 to 2000 due to the cropland land use fraction changes without considering the impact from climate changes. This induces a net dust direct effective radiative forcing of −0.041 W m −2 at top of the atmosphere. This dust-induced cooling exceeds 10% of the total anthropogenic aerosol direct effective radiative forcing from 1750 to 2014 estimated by the Intergovernmental Panel on Climate Change Sixth Assessment Report. Our findings indicate an important role of anthropogenic dust in global climate change, which should be included in future climate change assessments.

agricultural dust↗

Silicon cantilever functionalization for cellulose-specific chemical force imaging of switchgrass

A method for direct functionalization of silicon and silicon nitride cantilevers with bifunctional silanes was tested with model surfaces to determine adhesive forces for different hydrogen-bonding chemistries. Application for biomass surface characterization was tested by mapping switchgrass and isolated switchgrass cellulose in topographic and force-volume mode using a cellulose-specific cantilever.

60 APPLIED LIFE SCIENCES↗

A low temperature scanning tunneling microscope for electronic and force spectroscopy

In this article, we describe and test a novel way to extend a low temperature scanning tunneling microscope with the capability to measure forces. The tuning fork that we use for this is optimized to have a high quality factor and frequency resolution. Moreover, as this technique is fully compatible with the use of bulk tips, it is possible to combine the force measurements with the use of superconductive or magnetic tips, advantageous for electronic spectroscopy. It also allows us to calibrate both the amplitude and the spring constant of the tuning fork easily, in situ and with high precision.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Atomic force microscope cantilever spring constant evaluation for higher mode oscillations: A kinetostatic method

Our previous study of the particle mass sensor has shown a large ratio (up to thousands) between the spring constants of a rectangular cantilever in higher mode vibration and at the static bending or natural mode vibration. This has been proven by us through the derived nodal point position equation. That solution is good for a cantilever with the free end in noncontact regime and the probe shifted from the end to an effective section and contacting a soft object. Our further research shows that the same nodal position equation with the proper frequency equations may be used for the same spring constant ratio estimation if the vibrating at higher mode cantilever's free end has a significant additional mass clamped to it or that end is in permanent contact with an elastic or hard measurand object (reference cantilever). However, in the latter case, the spring constant ratio is much smaller (in tens) than in other mentioned cases at equal higher (up to fourth) vibration modes. We also present the spring constant ratio for a vibrating at higher eigenmode V-shaped cantilever, which is now in wide use for atomic force microscopy. The received results on the spring constant ratio are in good (within a few percent) agreement with the theoretical and experimental data published by other researchers. The knowledge of a possible spring constant transformation is important for the proper calibration and use of an atomic force microscope with vibrating cantilever in the higher eigenmodes for measurement and imaging with enlarged resolution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

New surface forces apparatus using two-beam interferometry

We designed a new surface forces apparatus for measuring the interactions between two nontransparent substrates and/or in nontransparent liquids. The small displacement of a surface, the bottom one in this study, was measured by the two-beam (twin path) interferometry technique using the phase difference between the laser light reflected by the fixed mirror and that by the mirror on the back of the bottom surface unit. It is possible to determine the distance with a resolution of 1 nm in the working range of 5 {mu}m. This apparatus was successfully applied to measure the forces between mica surfaces in pure water and aqueous KBr solutions.

36 MATERIALS SCIENCE↗

Influence of the radio frequency ponderomotive force on anomalous impurity transport in tokamaks

Trace impurity transport in tokamaks is studied using an electrostatic, collisionless fluid model for ion-temperature-gradient and trapped-electron mode driven turbulence in the presence of radio frequency (rf) fields, and the results are compared with neoclassical predictions. It is shown that the inward impurity convective velocity (pinch) that is usually obtained can be reduced by the rf fields, in particular close to the wave resonance location where the rf ponderomotive force may be significant. However, the impurity diffusivity and convective velocity are usually similarly affected by the ponderomotive force, and hence the steady-state impurity density peaking factor -{nabla}n{sub z}/n{sub z} is only moderately affected by the rf fields.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Cross-talk compensation in atomic force microscopy

In this work, calibration and correction of cross-talk in atomic force microscopy (AFM) is demonstrated. Several reasons and effects of this inherent problem on experimental results are discussed. We propose a general procedure that can be used on most AFM systems to compensate for cross-talk on the cantilever bending and twisting signals. The method utilizes two initial experiments on a flat surface to achieve an affine transformation between the measured signals and the actual signals. Using this transformation directly on the voltage signals allows us to remove the detrimental effects of cross-talk on AFM-based force measurement experiments. The achieved transformation matrix can be turned into a simple circuit and applied online, by users who have access to the raw signals in the AFM head. As a case study, a lateral deflection based mechanical characterization test for a poly(methyl methacrylate) microfiber that is suspended on a trench is investigated in terms of the effectiveness of the cross-talk compensation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Photothermal excitation and laser Doppler velocimetry of higher cantilever vibration modes for dynamic atomic force microscopy in liquid

The authors present an optically based method combining photothermal excitation and laser Doppler velocimetry of higher cantilever vibration modes for dynamic atomic force microscopy in liquid. The frequency spectrum of a silicon cantilever measured in water over frequencies ranging up to 10 MHz shows that the method allows us to excite and detect higher modes, from fundamental to fifth flexural, without enhancing spurious resonances. By reducing the tip oscillation amplitude using higher modes, the average tip-sample force gradient due to chemical bonds is effectively increased to achieve high-spatial-resolution imaging in liquid. The method's performance is demonstrated by atomic resolution imaging of a mica surface in water obtained using the second flexural mode with a small tip amplitude of 99 pm; individual atoms on the surface with small height differences of up to 60 pm are clearly resolved.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Electrical transport and mechanical properties of alkylsilane self-assembled monolayers on silicon surfaces probed by atomic force microscopy

The correlation between molecular conductivity and mechanical properties (molecular deformation and frictional responses) of hexadecylsilane self-assembled monolayers was studied with conductive probe atomic force microscopy/friction force microscopy in ultrahigh vacuum. Current and friction were measured as a function of applied pressure, simultaneously, while imaging the topography of self-assembled monolayer molecule islands and silicon surfaces covered with a thin oxide layer. Friction images reveal lower friction over the molecules forming islands than over the bare silicon surface, indicating the lubricating functionality of alkylsilane molecules. By measuring the tunneling current change due to changing of the height of the molecular islands by tilting the molecules under pressure from the tip, we obtained an effective conductance decay constant ({beta}) of 0.52/{angstrom}.

36 MATERIALS SCIENCE↗

Influence of the centrifugal force and parallel dynamics on the toroidal momentum transport due to small scale turbulence in a tokamak

The paper derives the gyro-kinetic equation in the comoving frame of a toroidally rotating plasma, including both the Coriolis drift effect [A. G. Peeters et al., Phys. Rev. Lett. 98, 265003 (2007)] as well as the centrifugal force. The relation with the laboratory frame is discussed. A low field side gyro-fluid model is derived from the gyro-kinetic equation and applied to the description of parallel momentum transport. The model includes the effects of the Coriolis and centrifugal force as well as the parallel dynamics. The latter physics effect allows for a consistent description of both the Coriolis drift effect as well as the ExB shear effect [R. R. Dominguez and G. M. Staebler, Phys. Fluids B 5, 3876 (1993)] on the momentum transport. Strong plasma rotation as well as parallel dynamics reduce the Coriolis (inward) pinch of momentum and can lead to a sign reversal generating an outward pinch velocity. Also, the ExB shear effect is, in a similar manner, reduced by the parallel dynamics and stronger rotation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A method for atomic force microscopy cantilever stiffness calibration under heavy fluid loading

This work presents a method for force calibration of rectangular atomic force microscopy (AFM) microcantilevers under heavy fluid loading. Theoretical modeling of the thermal response of microcantilevers is discussed including a fluid-structure interaction model of the cantilever-fluid system that incorporates the results of the fluctuation-dissipation theorem. This model is curve fit to the measured thermal response of a cantilever in de-ionized water and a cost function is used to quantify the difference between the theoretical model and measured data. The curve fit is performed in a way that restricts the search space to parameters that reflect heavy fluid loading conditions. The resulting fitting parameters are used to calibrate the cantilever. For comparison, cantilevers are calibrated using Sader's method in air and the thermal noise method in both air and water. For a set of eight cantilevers ranging in stiffness from 0.050 to 5.8 N/m, the maximum difference between Sader's calibration performed in air and the new method performed in water was 9.4%. A set of three cantilevers that violate the aspect ratio assumption associated with the fluid loading model (length-to-width ratios less than 3.5) ranged in stiffness from 0.85 to 4.7 N/m and yielded differences as high as 17.8%.

42 ENGINEERING↗

Atomic force microscopy imaging using a tip-on-chip: Opening the door to integrated near field nanotools

We describe in detail how atomic force microscopy (AFM) images can be routinely achieved with macroscopic silicon-based chips integrating mesoscopic tips, paving the way for the development of new near field devices combining AFM imaging with any kind of functionality integrated on a chip. The chips have been glued at the end of the free prong of 100 kHz quartz tuning forks mounted in Qplus configuration. Numerical simulations by modal analysis have been carried out to clarify the nature of the vibration modes observed in the experimental spectra. It is shown that two low frequency modes can be used to drive the system and scan the surface with a great stability in amplitude modulation as well as in frequency modulation AFM under ultrahigh vacuum. The AFM capabilities are demonstrated through a series of examples including phase and dissipation contrast imaging, force spectroscopy measurements, and investigations of soft samples in weak interaction with the substrate. The lateral resolution with the tips grown by focused ion beam deposition already matches the one achieved in standard amplitude modulation mode AFM experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Electrical characterization of HgTe nanowires using conductive atomic force microscopy

Self-organized HgTe nanowires grown by molecular beam epitaxy (MBE) have been characterized using conductive atomic force microscopy. As HgTe will degrade or evaporate at normal baking temperatures for electron beam lithography (EBL) resists, an alternative method was developed. Using low temperature optical lithography processes, large Au contacts were deposited on a sample covered with randomly oriented, lateral HgTe nanowires. Nanowires partly covered by the large electrodes were identified with a scanning electron microscope and then localized in the atomic force microscope (AFM). The conductive tip of the AFM was then used as a movable electrode to measure current-voltage curves at several locations on HgTe nanowires. The measurements revealed that polycrystalline nanowires had diffusive electron transport, with resistivities two orders of magnitude larger than that of an MBE-grown HgTe film. The difference can be explained by scattering at the rough surface walls and at the grain boundaries in the wires. The method can be a solution when EBL is not available or requires too high temperature, or when measurements at several positions along a wire are required.

36 MATERIALS SCIENCE↗

Combined quantitative ultrasonic and time-resolved interaction force AFM imaging

The authors describe a method where quantitative ultrasonic atomic force microscopy (UAFM) is achieved during time-resolved interaction force (TRIF) imaging in intermittent contact mode. The method uses a calibration procedure for quantitative UAFM. It improves elasticity measurements of stiff regions of surfaces while retaining the capabilities of the TRIF mode for topography, adhesion, dissipation, and elasticity measurements on soft regions of sample surfaces. This combination is especially advantageous when measuring and imaging samples with broad stiffness range in a nondestructive manner. The experiments utilize an active AFM probe with high bandwidth and the UAFM calibration is performed by measuring the magnitude of the time-resolved UAFM signal at a judiciously chosen frequency for different contact stiffness values during individual taps. Improved sensitivity to stiff surface elasticity is demonstrated on a special sample. The results show that combining UAFM with TRIF provides 2.5 GPa (5%) standard deviation on the silicon surface reduced Young's modulus, representing 5x improvement over using only TRIF mode imaging.

42 ENGINEERING↗

Switching surface polarization of atomic force microscopy probe utilizing photoisomerization of photochromic molecules

An attempt to develop an atomic force microscopy (AFM) probe with optically switchable polarization is described. Modification with a single molecular layer of photochromic molecules was attempted onto a Si substrate that is a prototype for a probe surface. Polarization switching caused by alternate irradiation of UV and visible lights were detected using the electrostatic force?>spectroscopy (EFS) technique. Si substrates modified with spiropyran and azobenzene exhibited reversible polarization switching that caused changes in CPD of about 100 and 50 mV, respectively. Modification with spiropyran was also attempted onto a Si probe and resulted in a CPD change of about 100 mV. It was confirmed that modification of an AFM probe or substrate with a single molecular layer of photochromic molecules can generate surface polarization switching of a mechanically detectable level.

74 ATOMIC AND MOLECULAR PHYSICS↗