At least 1,405 records · Page 78

On Flow Stagnation in a Tube Radiator

An analysis of the physical process for occurrence of flow stagnation in a space tube-radiator is performed and the mechanism and mathematic description for the flow stagnation are presented. Two causes for pressure drop unbalance between tubes of the radiator are identified: non-uniform cooling environment and different local flow resistances between the tubes. This analysis provides a theoretical basis for experimental simulations of the flow stagnation in a ground-based lab as well as two suggested methods to experimentally simulate flow stagnation. Criteria for the flow stagnation, depending on the viscosity data regressive polynomial, are derived from the extreme condition of the pressure drop in colder tubes. A preliminary numerical calculation is conducted for a space tube-radiator model which confirms the physical and mathematical analyses. The prediction by the criteria for flow stagnation in the tube-radiator model coincides with the numerical calculation result.

Motil, Brian↗

Calibration of spherical reference surfaces for Fizeau interferometry: a comparative study of methods

We present an experimental study of three calibration methods for spherical reference surfaces in Fizeau interferometry. The ball average, which relies on averaging measurements of a test ball surface over sufficiently many random rotations of the ball, is theoretically an absolute technique but can be very laborious. On the other hand, a recently introduced double-pass technique, comparing the two halves of the reference surface, is able to determine the point-symmetric contribution in as few as three measurements but does not detect the point-antisymmetric portion. Finally, the point-symmetric errors of the reference surface can be captured in a single, so-called ''cat's-eye'' measurement. Our study tries to answer the question of which of the techniques is preferable in practice. We find that the answer depends on the required uncertainty, and it appears that the new double-pass technique represents a practical and reasonable trade-off between expediency and accuracy.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Neutronics Analysis Supporting Baseline Fuel-Rodlet Irradiation Design in TREAT Multi-SERTTA Vehicle

The Transient Reactor Test (TREAT) Facility is a thermal-spectrum test reactor designed to evaluate reactor fuels and structural material under simulated nuclear excursion and transient power/cooling mismatch situations in nuclear reactors. TREAT was historically operated from 1959 through 1994. There are ongoing activities to resume its transient testing capabilities to support advanced reactor designs and validate computational predictions of fuel and core behavior. Such validation will be an important factor for review and approval of next generation power reactor design and safety evaluations. Historic methods used in TREAT were very approximate and served to estimate a predicted transient power shape. A number of calibration test experiments were then required prior to the actual transient test to better estimate the power that would have been deposited in the experiment during a transient pulse. Much of the experience in the use of these legacy methods has also been lost over the past two decades. Monte Carlo criticality codes are being utilized for calculation of the initial critical state, control rod reactivity worth, and power coupling between core and experiments. Current efforts primarily support neutronics characterization with safety and design analyses for the Multi-SERTTA (Static Environment Rodlet Transient Test Apparatuses) experiment test vehicle, which can accommodate up to four concurrent rodlets under separate environmental conditions. Ongoing efforts are necessary in preparation of transient testing support for Accident Tolerant Fuel (ATF) characterization and other future fuels testing requirements. The power coupling factor (PCF) is one of two key parameters utilized in designing and characterizing the performance of a TREAT fuel irradiation experiment. The second key parameter is the Transient Correction Factor (TCF) which accounts for time-dependent effects. The PCF is the effective quantity of fission-generated energy per mass of fuel specimen per total core energy. The quantity of energy deposited into a fuel rodlet under various test environments can be used to evaluate overall fuel performance, including failure mechanisms and thresholds. Baseline fuel rodlet calculations have been performed to estimate the effectiveness of the Multi-SERTTA test vehicle and optimization of PCF for various test conditions. The baseline serves as reference fuel pin conditions against which calibration and baseline experiments can be performed prior to actual ATF transient testing. Baseline experiments further serve to validate computational analyses and experimental test methods prior to design planning, experimentation, and evaluation of the ATF candidates. This paper serves to document activities performed to evaluate a reference Pressurized Water Reactor (PWR) rodlet design in the TREAT Multi-SERTTA test vehicle. (authors)

42 ENGINEERING↗

Nonradiative recombination of excitons in semimagnetic quantum dots

The mechanisms of the nonradiative recombination of excitons in neutral and charged quantum dots based on II–VI semimagnetic semiconductors are investigated. It is shown that, along with the dipole–dipole and direct-exchange mechanisms, there is one more mechanism referred to as the indirect-exchange mechanism and related to sp–d mixing. The selection rules for nonradiative recombination by exchange mechanisms are subsequently derived. The dependence of the efficiency of all recombination mechanisms on the quantum-dot size is studied. The experimentally observed growth in the intracenter photoluminescence intensity with decreasing size of dots and nanocrystals is accounted for. Methods for experimental determination of the contributions of different mechanisms to nonradiative recombination are discussed.

36 MATERIALS SCIENCE↗

The experimental verification of a streamline curvature numerical analysis method applied to the flow through an axial flow fan

The experimental verification of an inviscid, incompressible through-flow analysis method is presented. The primary component of this method is an axisymmetric streamline curvature technique which is used to compute the hub-to-tip flow field of a given turbomachine. To analyze the flow field in the blade-to-blade plane of the machine, the potential flow solution of an infinite cascade of airfoils is also computed using a source model technique. To verify the accuracy of such an analysis method an extensive experimental verification investigation was conducted using an axial flow research fan. Detailed surveys of the blade-free regions of the machine along with intra-blade surveys using rotating pressure sensing probes and blade surface static pressure taps provide a one-to-one relationship between measured and predicted data. The results of this investigation indicate the ability of this inviscid analysis method to predict the design flow field of the axial flow fan test rotor to within a few percent of the measured values.

Pierzga, M. J.↗

Effects of guest atomic species on the lattice thermal conductivity of type-I silicon clathrate studied via classical molecular dynamics

The effects of guest atomic species in Si clathrates on the lattice thermal conductivity were studied using classical molecular dynamics calculations. The interaction between a host atom and a guest atom was described by the Morse potential function while that between host atoms was described by the Tersoff potential. The parameters of the potentials were newly determined for this study such that the potential curves obtained from first-principles calculations for the insertion of a guest atom into a Si cage were successfully reproduced. The lattice thermal conductivities were calculated by using the Green-Kubo method. The experimental lattice thermal conductivity of Ba{sub 8}Ga{sub 16}Si{sub 30} can be successfully reproduced using the method. As a result, the lattice thermal conductivities of type-I Si clathrates, M{sub 8}Si{sub 46} (M = Na, Mg, K, Ca Rb, Sr, Cs, or Ba), were obtained. It is found that the lattice thermal conductivities of M{sub 8}Si{sub 46}, where M is IIA elements (i.e., M = Mg, Ca, Sr, or Ba) tend to be lower than those of M{sub 8}Si{sub 46}, where M is IA elements (i.e., M = Na, K, Rb, or Cs). Those of {sup m}M{sub 8}Si{sub 46}, where m was artificially modified atomic weight were also obtained. The obtained lattice thermal conductivity can be regarded as a function of a characteristic frequency, f{sub c}. That indicates minimum values around f{sub c}=2-4 THz, which corresponds to the center of the frequencies of the transverse acoustic phonon modes associated with Si cages.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Structural damage detection of space truss structures using best achievable eigenvectors

A method is presented by which measured modes and frequencies from a modal test can be used to determine the location and magnitude of damage in a space struss structure. The damage is located by computing the Euclidean distances between the measured mode shapes and the best achievable eigenvectors. The best achievable eigenvectors are the projection of the measured mode shapes onto the subspace defined by the refined analytical model of the structure and the measured frequencies. Loss of both stiffness and mass properties can be located and quantified. To examine the performance of the method when experimentally measured modes are employed, various damage detection studies using a laboratory eight-bay truss structure were conducted. The method performs well even though the measurement errors inevitably make the damage location more difficult.

Lim, Tae W.↗

Effects of laser fluence on the Cd(OH){sub 2}/CdO nanostructures produced by pulsed laser ablation method

In this experimental study, Cd (OH){sub 2}/CdO nanostructures were produced by pulsed laser ablation method. The beam of a Q-switched Nd:YAG laser with wavelength of 1064 nm at different fluences was employed to irradiate the cadmium target in distilled water. The obtained products at different fluences of laser pulse were characterized by UV–Vis-NIR spectroscopy, X-ray diffraction, scanning electron microscopy, and transmission electron microscopy. Results show that both morphology and chemical bonds of produced Cd nanostructures were changed by increasing the laser fluence. The absorption spectra shows that the Cd(OH){sub 2} nanostructures could be transformed into CdO nanostructures with increasing the laser fluence. XRD analysis showed the presence of crystalline γ-Cd(OH){sub 2}, Cd(OH){sub 2} and CdO phases, in the monoclinic, hexagonal and cubic structure, respectively. Results revealed that obtained nanostructures are particle in lowest fluence, while wire shaped nanostructures were formed with increasing the laser fluence. An increase of the laser fluence induced the synthesis of higher aspect ratio nanowires with a smaller tendency of adhesion.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Acousto-Optic Power Summation for Mutually Noncoherent Pulsed Lasers

A method of the power summation for mutually noncoherent pulsed lasers of the same type using time interleaving is proposed and validated experimentally. The method uses an acoustic-optic deflector, which commutates radiation of different sources into one output channel simultaneously with radiation presenting in this channel. It is crucially important that the power of the final output radiation is equal to the power sum of the input sources, and the angular and coordinate parameters of an output beam are the same as that for the input sources. The experiments were carried out with single-mode diode lasers on a wavelength of 1.3 μm using a ТеО{sub 2}-crystal-based deflector. The method is appropriate for the power summation for fiber-optic, diode, and solid-state lasers. We have estimated the main interrelated parameters.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Evaluation of the Inclusive Electron Scattering Observables in the Resonance Region from the Experimental Data

The method for evaluation of inclusive electron scattering observables in the resonance region from the experimental data is presented. The computer codes in the web page allow user to evaluate inclusive electron scattering, virtual photon-proton cross sections and the F{sub 1} and F{sub 2} structure functions at the invariant masses of the final hadrons 1.0 < W < 4.0 GeV and at photon virtualities 0.5 < Q {sup 2} < 7.0 GeV{sup 2}. The developed approach is of interest for analyses of the experimental data on exploration of the hadron structure in the experiments with electromagnetic probes.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

SU-F-BRD-16: Relative Biological Effectiveness of Double-Strand Break Induction for Modeling Cell Survival in Pristine Proton Beams of Different Dose-Averaged Linear Energy Transfers

Purpose: High throughput in vitro experiments assessing cell survival following proton radiation indicate that both the alpha and the beta parameters of the linear quadratic model increase with increasing proton linear energy transfer (LET). We investigated the relative biological effectiveness (RBE) of double-strand break (DSB) induction as a means of explaining the experimental results. Methods: Experiments were performed with two lung cancer cell lines and a range of proton LET values (0.94 – 19.4 keV/µm) using an experimental apparatus designed to irradiate cells in a 96 well plate such that each column encounters protons of different dose-averaged LET (LETd). Traditional linear quadratic survival curve fitting was performed, and alpha, beta, and RBE values obtained. Survival curves were also fit with a model incorporating RBE of DSB induction as the sole fit parameter. Fitted values of the RBE of DSB induction were then compared to values obtained using Monte Carlo Damage Simulation (MCDS) software and energy spectra calculated with Geant4. Other parameters including alpha, beta, and number of DSBs were compared to those obtained from traditional fitting. Results: Survival curve fitting with RBE of DSB induction yielded alpha and beta parameters that increase with proton LETd, which follows from the standard method of fitting; however, relying on a single fit parameter provided more consistent trends. The fitted values of RBE of DSB induction increased beyond what is predicted from MCDS data above proton LETd of approximately 10 keV/µm. Conclusion: In order to accurately model in vitro proton irradiation experiments performed with high throughput methods, the RBE of DSB induction must increase more rapidly than predicted by MCDS above LETd of 10 keV/µm. This can be explained by considering the increased complexity of DSBs or the nature of intra-track pairwise DSB interactions in this range of LETd values. NIH Grant 2U19CA021239-35.

60 APPLIED LIFE SCIENCES↗

A detailed numerical model for flat-plate solar thermal devices

A one-dimensional transient numerical model for flat-plate solar thermal devices is here presented. The model permits the analysis of different configurations and components such as multiple-glazing, transparent insulation, air-gaps, surface coatings, opaque insulation and energy accumulation in water or PCM internal stores. In order to obtain information of practical interest, the solar thermal devices are modelled following virtual testing procedures in accordance to the experimental test methods described by European and International standards. This paper describes the basis of the model and shows some comparison of numerical and experimental data as an example of the validation process that has been carried out in order to assess the credibility of the numerical model. For simplicity, the explanation is restricted to standard multiple-glazed flat-plate collectors. The use of the model in other more complicated configurations as in transparently insulated covers or integrated collector storage devices with phase change materials will be presented in other separate papers. (author)

14 SOLAR ENERGY↗

A Verification Suite of Test Cases for the Barotropic Solver of Ocean Models

Abstract The development of any atmosphere or ocean model warrants a suite of test cases (TCs) to verify its spatial and temporal discretizations, order of accuracy, stability, reproducibility, portability, scalability, etc. In this paper, we present a suite of shallow water TCs designed to verify the barotropic solver of atmosphere and ocean models. These include the non‐dispersive coastal Kelvin wave; the dispersive inertia‐gravity wave; the dispersive planetary and topographic Rossby waves; the barotropic tide; and a non‐linear manufactured solution. These TCs check the implementation of the linear pressure gradient term; the linear constant or variable‐coefficient Coriolis and bathymetry terms; and the non‐linear advection terms. Simulation results are presented for a variety of time‐stepping methods as well as two spatial discretizations: a mimetic finite volume method based on the TRiSK scheme, and a high‐order discontinuous Galerkin spectral element method. The experimental procedure for conducting these numerical experiments is detailed. It underscores several key considerations that vary depending on the chosen spatial discretization method. Finally, convergence studies of every TC are conducted with refinement in both space and time, only in space, and only in time. The convergence slopes match the expected theoretical predictions.

54 ENVIRONMENTAL SCIENCES↗

Theoretical and experimental studies of the current–voltage and capacitance–voltage of HEMT structures and field-effect transistors

The sensitivity of classical n{sup +}/n{sup –} GaAs and AlGaN/GaN structures with a 2D electron gas (HEMT) and field-effect transistors based on these structures to γ-neutron exposure is studied. The levels of their radiation hardness were determined. A method for experimental study of the structures on the basis of a differential analysis of their current–voltage characteristics is developed. This method makes it possible to determine the structure of the layers in which radiation-induced defects accumulate. A procedure taking into account changes in the plate area of the experimentally measured barrier-contact capacitance associated with the emergence of clusters of radiation-induced defects that form dielectric inclusions in the 2D-electron-gas layer is presented for the first time.

36 MATERIALS SCIENCE↗

The momentum transfer of incompressible turbulent separated flow due to cavities with steps

An experimental study was conducted using a plate test bed having a turbulent boundary layer to determine the momentum transfer to the faces of step/cavity combinations on the plate. Experimental data were obtained from configurations including an isolated configuration and an array of blocks in tile patterns. A momentum transfer correlation model of pressure forces on an isolated step/cavity was developed with experimental results to relate flow and geometry parameters. Results of the experiments reveal that isolated step/cavity excrecences do not have a unique and unifying parameter group due in part to cavity depth effects and in part to width parameter scale effects. Drag predictions for tile patterns by a kinetic pressure empirical method predict experimental results well. Trends were not, however, predicted by a method of variable roughness density phenomenology.

White, R. E.↗

Image-derived and arterial blood sampled input functions for quantitative PET imaging of the angiotensin II subtype 1 receptor in the kidney

Purpose: The radioligand {sup 11}C-KR31173 has been introduced for positron emission tomography (PET) imaging of the angiotensin II subtype 1 receptor in the kidney in vivo. To study the biokinetics of {sup 11}C-KR31173 with a compartmental model, the input function is needed. Collection and analysis of arterial blood samples are the established approach to obtain the input function but they are not feasible in patients with renal diseases. The goal of this study was to develop a quantitative technique that can provide an accurate image-derived input function (ID-IF) to replace the conventional invasive arterial sampling and test the method in pigs with the goal of translation into human studies. Methods: The experimental animals were injected with [{sup 11}C]KR31173 and scanned up to 90 min with dynamic PET. Arterial blood samples were collected for the artery derived input function (AD-IF) and used as a gold standard for ID-IF. Before PET, magnetic resonance angiography of the kidneys was obtained to provide the anatomical information required for derivation of the recovery coefficients in the abdominal aorta, a requirement for partial volume correction of the ID-IF. Different image reconstruction methods, filtered back projection (FBP) and ordered subset expectation maximization (OS-EM), were investigated for the best trade-off between bias and variance of the ID-IF. The effects of kidney uptakes on the quantitative accuracy of ID-IF were also studied. Biological variables such as red blood cell binding and radioligand metabolism were also taken into consideration. A single blood sample was used for calibration in the later phase of the input function. Results: In the first 2 min after injection, the OS-EM based ID-IF was found to be biased, and the bias was found to be induced by the kidney uptake. No such bias was found with the FBP based image reconstruction method. However, the OS-EM based image reconstruction was found to reduce variance in the subsequent phase of the ID-IF. The combined use of FBP and OS-EM resulted in reduced bias and noise. After performing all the necessary corrections, the areas under the curves (AUCs) of the AD-IF were close to that of the AD-IF (average AUC ratio =1 ± 0.08) during the early phase. When applied in a two-tissue-compartmental kinetic model, the average difference between the estimated model parameters from ID-IF and AD-IF was 10% which was within the error of the estimation method. Conclusions: The bias of radioligand concentration in the aorta from the OS-EM image reconstruction is significantly affected by radioligand uptake in the adjacent kidney and cannot be neglected for quantitative evaluation. With careful calibrations and corrections, the ID-IF derived from quantitative dynamic PET images can be used as the input function of the compartmental model to quantify the renal kinetics of {sup 11}C-KR31173 in experimental animals and the authors intend to evaluate this method in future human studies.

60 APPLIED LIFE SCIENCES↗

Unification of nonequilibrium molecular dynamics and the mode-resolved phonon Boltzmann equation for thermal transport simulations

Nano-size confinement induces many intriguing non-Fourier heat conduction phenomena, such as nonlinear temperature gradients, temperature jumps near the contacts, and size-dependent thermal conductivity. Over the past decades, these effects have been studied and interpreted by nonequilibrium molecular dynamics (NEMD) and phonon Boltzmann transport equation (BTE) simulations separately, but no theory that unifies these two methods has ever been established. In this work, we unify these methods using a quantitative mode-level comparison and demonstrate that they are equivalent for various thermostats. We show that different thermostats result in different non-Fourier thermal transport characteristics due to the different mode-level phonon excitations inside the thermostats, which explains the different size-dependent thermal conductivities calculated using different reservoirs, even though they give the same bulk thermal conductivity. Specifically, the Langevin thermostat behaves like a thermalizing boundary in phonon BTE and provides mode-level thermal-equilibrium phonon outlets, while the Nose-Hoover chain thermostat and velocity rescaling method behave like biased reservoirs, which provide a spatially uniform heat generation and mode-level nonequilibrium phonon outlets. These findings explain why different experimental measurement methods can yield different size-dependent thermal conductivity. They also indicate that the thermal conductivity of materials can be tuned for various applications by specifically designing thermostats. Finally, the unification of NEMD and phonon BTE will largely facilitate the study of thermal transport in complex systems in the future by, e.g., replacing computationally unaffordable first-principles NEMD simulations with computationally less expensive spectral BTE simulations.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Analytical equations for CT dose profiles derived using a scatter kernel of Monte Carlo parentage with broad applicability to CT dosimetry problems

Purpose: Knowledge of the complete axial dose profile f(z), including its long scatter tails, provides the most complete (and flexible) description of the accumulated dose in CT scanning. The CTDI paradigm (including CTDI{sub vol}) requires shift-invariance along z (identical dose profiles spaced at equal intervals), and is therefore inapplicable to many of the new and complex shift-variant scan protocols, e.g., high dose perfusion studies using variable (or zero) pitch. In this work, a convolution-based beam model developed by Dixon et al.[Med. Phys. 32, 3712-3728, (2005)] updated with a scatter LSF kernel (or DSF) derived from a Monte Carlo simulation by Boone [Med. Phys. 36, 4547-4554 (2009)] is used to create an analytical equation for the axial dose profile f(z) in a cylindrical phantom. Using f(z), equations are derived which provide the analytical description of conventional (axial and helical) dose, demonstrating its physical underpinnings; and likewise for the peak axial dose f(0) appropriate to stationary phantom cone beam CT, (SCBCT). The methodology can also be applied to dose calculations in shift-variant scan protocols. This paper is an extension of our recent work Dixon and Boone [Med. Phys. 37, 2703-2718 (2010)], which dealt only with the properties of the peak dose f(0), its relationship to CTDI, and its appropriateness to SCBCT. Methods: The experimental beam profile data f(z) of Mori et al.[Med. Phys. 32, 1061-1069 (2005)] from a 256 channel prototype cone beam scanner for beam widths (apertures) ranging from a = 28 to 138 mm are used to corroborate the theoretical axial profiles in a 32 cm PMMA body phantom. Results: The theoretical functions f(z) closely-matched the central axis experimental profile data{sup 11} for all apertures (a = 28 -138 mm). Integration of f(z) likewise yields analytical equations for all the (CTDI-based) dosimetric quantities of conventional CT (including CTDI{sub L} itself) in addition to the peak dose f(0) relevant to SCBCT (allowing direct cross-comparison between CT scan modes and mathematical proofs of several hypotheses of practical utility in CT dosimetry). A fast, analytical dose simulator{sup 6} is also demonstrated--successfully matching complex dose distributions measured using OSL and film dosimetry. Conclusions: The model described allows one to obtain analytical functions describing both the primary and scatter components of the axial dose profile. This model (using no empirical functions or adjustable fit parameters) provides a good match to the experimental data, as well as a complete analytical description of dose for both conventional (axial and helical) CT and cone beam CT. An efficient method whereby the complete data set for both modalities can be obtained from a single measurement of either CTDI{sub 100} or f(0) is illustrated. This method is also flexible--allowing calculation of heretofore unattainable doses for recently-introduced shift-variant protocols [e.g., variable pitch (irregular scan spacing), variable aperture, shuttle mode acquisition, and mA modulation schemes].

61 RADIATION PROTECTION AND DOSIMETRY↗