Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Diagnostics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,405 records · Page 78

H{sub 2}/N{sub 2} plasma damage on porous dielectric SiOCH film evaluated by in situ film characterization and plasma diagnostics

This study investigates the mechanism of H{sub 2}/N{sub 2} plasma ashing damage of porous SiOCH films. Porous SiOCH films were treated by a H{sub 2}/N{sub 2} plasma using a 100-MHz capacitively coupled plasma etcher. The impact of ions, radicals, and vacuum ultraviolet radiation on the porous SiOCH films was investigated using in situ bulk analysis techniques such as spectroscopic ellipsometry and Fourier-transform infrared spectroscopy and ex situ film characterization techniques such as dynamic secondary ion mass spectrometry and x-ray photoelectron spectroscopy. In addition, plasma analysis including vacuum ultraviolet absorption spectroscopy was performed. The film characterization and plasma analysis show that the extraction of methyl by H radicals was enhanced by light while N radicals were responsible for inhibit the extraction of Si-CH{sub 3} bonds by forming nitride layer. The H{sub 2}/N{sub 2} plasma damage mechanism is discussed based on characterization of the film and plasma diagnostics.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Optical diagnostic of bipolar electrical discharges in HCl, KCl, and KOH solutions

In this work, the characteristics of the plasma generated in HCl, KCl, and KOH solutions were analyzed using electrical and optical diagnostic techniques. Electrical discharges were initiated between two tungsten electrodes. Current and voltage characteristics have shown the features of a spark discharge for all of the solutions used in the experiment. The reactive species identified in the optical emission spectra depended on the type of solution used to generate the plasma. The time evolution of the reactive species depended on the nature of the solution and on the polarity of the applied pulse. The absorption spectra of the OH radical (X{sup 2}{Pi}{yields} A{sup 2}{Sigma}{sup +}) were acquired when the voltage pulses were applied to the electrodes, with the intensity being lower in the regions between the pulses. The OH radical density was highest for the HCl solution plasma (2 x 10{sup 17} cm{sup -3}) when positive voltage pulses were applied to the electrodes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A contribution to spectroscopic diagnostics and cathode sheath modeling of micro-hollow gas discharge in argon

In this paper, the hydrogen Balmer beta line shape from a micro-hollow gas discharge (MHGD) in argon with traces of hydrogen is used for simultaneous diagnostics of plasma and cathode sheath (CS) parameters. For this purpose, a simple model of relevant processes responsible for the line broadening is introduced and applied to the Balmer beta profile recorded from a MHGD generated in the microhole (diameter 100 {mu}m at narrow side and 130 {mu}m at wider side) of a gold-alumina-gold sandwich in the pressure range (100-900 mbar). The electron number density N{sub e} in the range (0.4-4.5) x 10{sup 20} m{sup -3} is determined from the width of the central part of the Balmer beta line profile, while, from the extended wings of the Balmer beta profile, induced by dc Stark effect, the next three parameters are determined: the average value E{sub a} of electric field strength in the CS in the range (16-95 kV/cm), the electric field strength E{sub 0} at the cathode surface in the range (32-190 kV/cm), and the CS thickness z{sub g} in the range (18-70 {mu}m). All four MHGD parameters, N{sub e}, E{sub a}, E{sub 0}, and z{sub g}, compare reasonably well with results of the modeling experiment by M. J. Kushner [J. Phys. D: Appl. Phys. 38, 1633 (2005)]. The results for N{sub e} are compared with other emission experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Beyond Zeeman spectroscopy: Magnetic-field diagnostics with Stark-dominated line shapes

A recently suggested spectroscopic approach for magnetic-field determination in plasma is employed to measure magnetic fields in an expanding laser-produced plasma plume in an externally applied magnetic field. The approach enables the field determination in a diagnostically difficult regime for which the Zeeman-split patterns are not resolvable, as is often encountered under the conditions characteristic of high-energy-density plasmas. Here, such conditions occur in the high-density plasma near the laser target, due to the dominance of Stark broadening. A pulsed-power system is used to generate magnetic fields with a peak magnitude of 25 T at the inner-electrode surface in a coaxial configuration. An aluminum target attached to the inner electrode surface is then irradiated by a laser beam to produce the expanding plasma that interacts with the applied azimuthal magnetic field. A line-shape analysis of the Al III 4s-4p doublet (5696 and 5722 A) enables the simultaneous determination of the magnetic field and the electron density. The measured magnetic fields are generally found to agree with those expected in a vacuum based on the pulsed-power system current. Examples of other transitions that can be used to diagnose a wide range of plasma and magnetic field parameters are presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Charge resolved electrostatic diagnostic of colliding copper laser plasma plumes

The collision of two laser generated plasma plumes can result, under appropriate conditions, in the formation of a ''stagnation layer.'' The processes underlying this phenomenon are complex and time dependent. The majority of experiments over the last few decades have focused upon spectroscopic diagnostic of colliding plasmas. We have performed electrostatic diagnosis of multiply charged copper ions (Cu{sup +} to Cu{sup 5+}) generated via Q-switched pulsed laser ({lambda} = 1.06 {mu}m, {tau} = 6 ns, and E{sub L} = 52-525 mJ) generation of copper plasma plumes from a planar target. Time dependent current traces, charge yields, and kinetic energy (K{sub e}) distributions are obtained for single plasma plumes (S{sub p}) and colliding plasma plumes (C{sub p}). The charge yield from a C{sub p} relative to twice that from a S{sub p} is characterized by a charge yield ratio (CYR) parameter. Superior ion yields for all charge states occur for a discrete range of fluences (F) from colliding plasma plumes leading to a CYR parameter exceeding unity. The kinetic energy distributions from colliding plasma plumes display well defined energy compression via narrowing of the distributions for all fluences and charge states. The extent of this energy compression is charge dependent. Space charge forces within the stagnation layer and the resulting charge dependent acceleration of ions are proposed to account for the transfer of ion kinetic energy in favour of collisional ionization mechanisms.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

RAMI Analyses of Heating Neutral Beam and Diagnostic Neutral Beam Systems for ITER

A RAMI (Reliability, Availability, Maintainability, Inspectability) analysis has been performed for the heating (and current drive) neutral beam (HNB) and diagnostic neutral beam (DNB) systems of the ITER device. The objective of these analyses is to implement RAMI engineering requirements for design and testing to prepare a reliability-centred plan for commissioning, operation, and maintenance of the system in the framework of technical risk control to support the overall ITER Project. These RAMI requirements will correspond to the RAMI targets for the ITER project and the compensating provisions to reach them as deduced from the necessary actions to decrease the risk level of the function failure modes. The RAMI analyses results have to match with the procurement plan of the systems.

43 PARTICLE ACCELERATORS↗

Microwave diagnostics of femtosecond laser-generated plasma filaments

We present a simple non-intrusive experimental method allowing a complete single shot temporal measurement of laser produced plasma filament conductivity. The method is based on filament interaction with low intensity microwave radiation in a rectangular waveguide. The suggested diagnostics allow a complete single shot temporal analysis of filament plasma decay with resolution better than 0.3 ns and high spatial resolution along the filament. The experimental results are compared to numerical simulations, and an initial electron density of 7 x 10{sup 16 }cm{sup -3} and decay time of 3 ns are obtained.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

3D Diagnostic Of Complex Plasma

This paper reports the development of a three-dimensional(3D) dust particle position diagnostic for complex plasmas. A beam produce by Light Emitting Diodes(LEDs) is formed into horizontal sheet, for the illumination of the particles. The light sheet has a vertical colour gradient across its width, from two opposing colours. The light scattered from the particles is imaged with the camera from above. The horizontal coordinates are measured from the positions on the image. The third coordinate is determined from the colour which represents a position on the gradient of the light sheet. The use of LEDs as a light source reduces a variation in Mie scattered intensity from the particles due to the particle size distribution. The variation would induce a large vertical positional error.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Improved chopping of a lithium beam for plasma edge diagnostic at ASDEX Upgrade

The lithium beam diagnostic at ASDEX Upgrade routinely delivers electron density profiles in the plasma edge by lithium beam impact excitation spectroscopy. An accurate background subtraction requires a periodically chopped lithium beam. A new, improved chopping system was developed and installed. It involves a voltage modulation for the extractor electrode and the beam deflection plates. The modulation of the extractor electrode reduces the unused portion of lithium ions and improves the stability of the beam with respect to its position. Furthermore, the data indicate an extended emitter lifetime. The extractor chopping was also found to be insensitive to sparks. The deflection chopping experiments demonstrated beam chopping in the kilohertz range. The significantly higher modulation frequency of the deflection chopping improves background subtraction of fast transient events. It allows a more accurate density measurements in the scrape off layer during impurity injections and edge localized modes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a Nomarski-type multi-frame interferometer as a time and space resolving diagnostics for the free electron density of laser-generated plasma

This article reports on the development and set-up of a Nomarski-type multi-frame interferometer as a time and space resolving diagnostics of the free electron density in laser-generated plasma. The interferometer allows the recording of a series of 4 images within 6 ns of a single laser-plasma interaction. For the setup presented here, the minimal accessible free electron density is 5 x 10{sup 18} cm{sup -3}, the maximal one is 2 x 10{sup 20} cm{sup -3}. Furthermore, it provides a resolution of the electron density in space of 50 {mu}m and in time of 0.5 ns for one image with a customizable magnification in space for each of the 4 images. The electron density was evaluated from the interferograms using an Abel inversion algorithm. The functionality of the system was proven during first experiments and the experimental results are presented and discussed. A ray tracing procedure was realized to verify the interferometry pictures taken. In particular, the experimental results are compared to simulations and show excellent agreement, providing a conclusive picture of the evolution of the electron density distribution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Diagnostics for hybrid reactors

The Hybrid Reactor(HR) can be considered an attractive actinide-burner or a fusion assisted transmutation for destruction of transuranic(TRU) nuclear waste. The hybrid reactor has two important subsystems: the tokamak neutron source and the blanket which includes a fuel zone where the TRU are placed and a tritium breeding zone. The diagnostic system for a HR must be as simple and robust as possible to monitor and control the plasma scenario, guarantee the protection of the machine and monitor the transmutation.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A new GEM based neutron diagnostic concept for high flux neutron beams

Fusion-fission hybrid reactors will need high flux neutron detectors to diagnose the deuterium-tritium fusion plasmas as well as the fission reactions. A candidate detection technique is the Gas Electron Multiplier (GEM). New GEM based detectors are being developed for application to a neutral deuterium beam test facility. The proposed detection system is called Close-contact Neutron Emission Surface Mapping (CNESM). The diagnostic aims at providing the map of the neutron emission due to interaction of the deterium beam with the deuterons implanted in the beam dump surface. This is done by placing a detector in close contact, right behind the dump. CNESM uses nGEM detectors, i.e. GEM detectors equipped with a cathode that also serves as neutron-proton converter foil. A small size prototype of nGEM detector has been built and is ready to be tested.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A new neutral particle analyzer diagnostic and its first commissioning on HL-2A

A new neutral particle analyzer diagnostic has been developed for HuanLiuqi-2A (commonly referred to as HL-2A), which can provide the neutral particle flux measurement along 11 separate sightlines, simultaneously, within a wider energy range (1-70 keV). It is an electrostatic type analyzer with a removable pinhole and special-shape condenser. The energy analysis can be flexibly achieved by controlling a preset stepwise high voltage on the condenser. It is compact and its field of view covers HL-2A cross section from -33 cm to 33 cm without 'cross-talk.' The energy spectra and ion temperature profile have been obtained during its commissioning.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A novel particle time of flight diagnostic for measurements of shock- and compression-bang times in D{sup 3}He and DT implosions at the NIF

The particle-time-of-flight (pTOF) diagnostic, fielded alongside a wedge range-filter (WRF) proton spectrometer, will provide an absolute timing for the shock-burn weighted {rho}R measurements that will validate the modeling of implosion dynamics at the National Ignition Facility (NIF). In the first phase of the project, pTOF has recorded accurate bang times in cryogenic DT, DT exploding pusher, and D{sup 3}He implosions using DD or DT neutrons with an accuracy better than {+-}70 ps. In the second phase of the project, a deflecting magnet will be incorporated into the pTOF design for simultaneous measurements of shock- and compression-bang times in D{sup 3}He-filled surrogate implosions using D{sup 3}He protons and DD-neutrons, respectively.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Compact 'diode-based' multi-energy soft x-ray diagnostic for NSTX

A novel and compact, diode-based, multi-energy soft x-ray (ME-SXR) diagnostic has been developed for the National Spherical Tokamak Experiment. The new edge ME-SXR system tested on NSTX consists of a set of vertically stacked diode arrays, each viewing the plasma tangentially through independent pinholes and filters providing an overlapping view of the plasma midplane which allows simultaneous SXR measurements with coarse sub-sampling of the x-ray spectrum. Using computed x-ray spectral emission data, combinations of filters can provide fast (>10 kHz) measurements of changes in the electron temperature and density profiles providing a method to 'fill-in' the gaps of the multi-point Thomson scattering system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Modulated active charge exchange fast ion diagnostic for the C-2 field-reversed configuration experiment

A diagnostic technique for measuring the fast-ion energy distribution in a field-reversed configuration plasma was developed and tested on the C-2 experiment. A deuterium neutral beam modulated at 22 kHz is injected into the plasma, producing a localized charge-exchange target for the confined fast protons. The escaping fast neutrals are detected by a neutral particle analyzer. The target beam transverse size ({approx}15 cm) defines the spatial resolution of the method. The equivalent current density of the target beam is {<=}0.15 A/cm{sup 2}, which corresponds to a neutral density ({approx}6 Multiplication-Sign 10{sup 9} cm{sup -3}) that highly exceeds the background neutral density in the core of C-2. The deuterium fast-ions due to the target beam (E{approx}27 keV), are not confined in C-2 and thus make a negligible contribution to the measured signals.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Solid debris collection for radiochemical diagnostics at the National Ignition Facility

Radiochemical analysis of post-ignition debris inside the National Ignition Facility (NIF) target chamber can help determine various diagnostic parameters associated with the implosion efficiency of the fusion capsule. This technique is limited by the ability to distinguish ablator material from other debris and by the collection efficiency of the capsule debris after implosion. Prior to designing an on-line collection system, the chemical nature and distribution of the debris inside the chamber must be determined. The focus of our current work has been on evaluating capture of activated Au hohlraum debris on passive foils (5 cm diameter, 50 cm from target center) post-shot. Preliminary data suggest that debris distribution is locally heterogeneous along the equatorial and polar line-of-sights.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Simultaneous imaging/reflectivity measurements to assess diagnostic mirror cleaning

Practical methods to clean ITER's diagnostic mirrors and restore reflectivity will be critical to ITER's plasma operations. We describe a technique to assess the efficacy of mirror cleaning techniques and detect any damage to the mirror surface. The method combines microscopic imaging and reflectivity measurements in the red, green, and blue spectral regions and at selected wavelengths. The method has been applied to laser cleaning of single crystal molybdenum mirrors coated with either carbon or beryllium films 150-420 nm thick. It is suitable for hazardous materials such as beryllium as the mirrors remain sealed in a vacuum chamber.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗