Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Detector arrays”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,405 records · Page 78

Infrared Astronomical Satellite /IRAS/ and Shuttle Infrared Telescope Facility /SIRTF/ - Implications of scientific objectives on focal plane sensitivity requirements

The full potential of infrared astronomy can be realized only through observations made with space-based telescopes cooled to cryogenic temperatures. The paper outlines the scientific mission, system description, and focal plane requirements for two cryogenic telescopes: the Infrared Astronomical Satellite (IRAS) and the Shuttle Infrared Telescope Facility (SIRTF). IRAS, a 60-cm superfluid-helium-cooled telescope system, will perform a one-year 8-120-micron IR sky survey; it will provide results of high reliability and sensitivity, produce the first complete survey data for the 30-120-micron region, and fill in missing portions (spectrally and spatially) of previous surveys short of 30 microns; its focal plane assembly is being designed to approach background-limited performance with an array of 62 discrete detectors. The SIRTF design will allow detailed follow-up studies in the 1-1000-micron range with a 116-160-cm observatory-class instrument. The Shuttle sortie capability introduces the unique SIRTF concept of an easily refurbishable or replaceable focal plane instrument complement in an orbiting cryogenic telescope.

Mccreight, C. R.↗

Spectroscopy from 2 to 200 keV

The astrophysical processes responsible for line and continuum emission in the spectra range 2 keV to 200 keV are examined from the viewpoint of designing a spectrometer which would operate in this regime. Phenomena considered include fluorescent line radiation in X-ray binaries, magnetically shifted iron lines and cyclotron emission from neutron star surfaces, line emission from cosmically abundant elements in thermal plasmas, and nuclear deexcitation lines in fresh nucleosynthetically produced matter. An instrument consisting of a approximately 10 sq cm array of planar germanium detectors surrounded by a large sodium-iodide anticoincidence shield is described and projected background rates and sensitivities are considered. A sample observing program for a two-day shuttle-based mission is included as an example of the wide range of scientific questions which could be addressed by such an instrument.

Helfand, D. J.↗

Temporal development of composition, spectra, and anisotropies during upstream particle events

An analysis is conducted of the temporal development of particle intensity, composition, and anisotropies during diffuse particle events. The observations were made with an ultra-low energy charge analyzer (ULECA) sensor. ULECA basically consists of an electrostatic deflection system and an array of solid state detectors. The simultaneous measurement of energy per charge and total energy makes it possible to determine the charge state of a particle. Spectra are derived by an iterative technique involving the numerical integration of particle spectra with the energy response functions of the individual detectors. The presented data are explained in terms of temporal and spatial structures in the upstream region. The temporal structures during the event onset are consistent with a time-dependent first-order Fermi acceleration model, as discussed by Scholer et al. (1980).

Ipavich, F. M.↗

Photometric and spectroscopic gamma-ray observations of solar transient phenomena using long duration balloons

A program currently in progress to conduct extended duration spectroscopic and photometric observation of solar X-ray phenomena from balloons is described. High photometric sensitivity to weak hard X-ray bursts is attained using a 600 sq cm array of phoswich scintillators. High spectral resolution for stronger bursts is available from an array of planar germanium detectors. These instruments are carried in a novel balloon gondola dssigned for the 15 to 20 day float durations available through using conventional zero pressure balloons in the radiation controlled (RACOON) mode.

Pelling, M. R.↗

Observation of muons from Cygnus X-3 in the NUSEX experiment

Ground based observations by means of Cerenkov light detectors and air shower arrays have established that Cyngus X-3 is a powerful source of high energy particles. The detection of a 10 to the 15th power eV signal was first reported by the Kiel experiment. Air showers with large age parameter were accepted in order to select those generated by primary gamma rays. At variance with the expectation, the muon density associated with these events was found to be surprisingly high. This puzzling result stimulated a temporal analysis of the muons recorded in Nucleon Stability Experiment (NUSEX) coming from the region around the source. A positive signal was found suggesting the presentation of this result. The analysis of the data recorded during the 2.4 years of effective working time is presented with a fine tuning of the period and the energy spectrum of the muons from the Cygnus X-3 direction derived assuming consistency between NUSEX and SOUDAN results.

Piazzoli, B. D.↗

Gamma-ray burst and spectroscopy instrumentation development at the Goddard Space Flight Center

This paper summarizes the activities that are specifically related to the development of instrumentation for gamma-ray astronomy. Three programs are described: (1) the Gamma-Ray Imaging Spectrometer (GRIS), a balloon-borne array of seven germanium detectors for high-resolution spectrographic studies of persistent gamma-ray sources; (2) the Transient Gamma-Ray Spectrometer (TGRS), a single radiatively-cooled germanium detector for the spectrographic study of gamma-ray bursts, and (3) the Rapidly Moving Telescope (RMT), a ground-based optical telescope for the detection and study of short-lived optical transients, particularly those that occur in coincidence with gamma-ray bursts.

Teegarden, B. J.↗

Molecular-Beam Epitaxy Of IrSi3

Molecular-beam epitaxy grows layers of iridium silicide (IrSi3) on silicon at temperatures of 630 to 800 degrees C. Particularly useful as photodetector material because it forms Schottky diodes having potential barriers of only 0.12 to 0.15 eV - lowest of any metal on silicon. Photodiodes sensitive to infrared radiation at wavelengths as large as 8 to 10 micrometers. New, lower formation temperature expected to enable growth of arrays of IrSi3/Si infrared detectors on Si wafers without thermally damaging image-processing circuitry integrated on wafers.

Lin, True-Lon↗

Infrared spectroscopy of comets

An observational search for cometary parent molecules using infrared spectroscopy was conducted in the 1 to 5 micron region. The investigation involved two different observing programs, one at moderate spectral resolution and one at fairly high resolution. The lower resolution was used to study cometary spectra in the vicinity of 3.5 micron at wavelength/change in wavelength is approximately or equal to 10(exp 3). Comets P/Brorsen-Metcalf (1989o), Okazaki-Levy-Rudenko (1989r), and Austin (1990c1) were observed with the Cryogenic Spectrometer (CRSP) at Kitt Peak. The detector incorporated an InSb array with 58 spatial elements, each 2.7 min on the sky, and 62 spectral channels per spatial element. An, as yet, unidentified feature was detected at approximately 3.52 micron in Comet Austin (on 1990 May 4, 5, and 6). The feature is possibly present in P/Brorsen-Metcalf (observed on 1989 August 23 and 25), as well. Comet Okazaki-Levy-Rudenko exhibited continuum emission only in this spectral region at the time of the observations (1989 November 14 and 16). The data are presented, and the relationship between the 3.52 micron feature and cometary activity (e.g., water production rate, visibility of the 3.4 micron emission feature) are discussed. The high resolution program probed comet Austin in the 4.8 micron region. These observations were used to search for emission lines comprising the (1-0) vibration-rotation band of the ground electronic state of CO. Retrieval of the lines allows a probe of the population distribution of levels J' = 1 through 4 of the excited (v' = 1) vibrational state within the ground electronic state of CO. Knowledge of this distribution can be used to constrain the rotational temperature. Preliminary analysis suggests the P3 line was present UT May 16 at roughly the 5 sigma level. Results concerning the existence of other lines, and physical conditions inferred therefrom are discussed.

Disanti, Michael A.↗

Where two frontiers meet

Current research projects conducted at the JPL Center for Space Microelectronics Technology are briefly reviewed. These include the development of a new miniature tunneling Goday cell that can be made into arrays. This tunneling IR detector is sensitive to radiation through the infrared and is particularly suited to room temperature measurements of the mid to far infrared. Other developments include ballistic-electron-emission microscopy, a next-generation spacecraft on-board computer using the Direct Memory Access Co-Processor, a 1-sq cm custom chip with 40,000 transistors, new neural network chips, the third-generation hypercube, and a new Hyperswitch Adaptive Message routing VLSI chip.

Kukkonen, Carl↗

The EGRET high energy gamma ray telescope

The Energetic Gamma Ray Experiment Telescope (EGRET) on the Compton Gamma Ray Observatory (GRO) is sensitive in the energy range from about 20 MeV to about 30,000 MeV. Electron-positron pair production by incident gamma photons is utilized as the detection mechanism. The pair production occurs in tantalum foils interleaved with the layers of a digital spark chamber system; the spark chamber records the tracks of the electron and positron, allowing the reconstruction of the arrival direction of the gamma ray. If there is no signal from the charged particle anticoincidence detector which surrounds the upper part of the detector, the spark chamber array is triggered by two hodoscopes of plastic scintillators. A time of flight requirement is included to reject events moving backward through the telescope. The energy of the gamma ray is primarily determined by absorption of the energies of the electron and positron in a 20 cm deep NaI(Tl) scintillator.

Hartman, R. C.↗

An observation of the Galactic center region with the HEXAGONE high resolution gamma-ray spectrometer

The Galactic center region was observed for 6 hours on May 22, 1989 from a high altitude balloon with the HEXAGONE high resolution gamma-ray spectrometer. The instrument had a 285 sq/cm array of cooled germanium detectors with an energy resolution of 2.2 keV at 511 keV and an 18 deg FWHM field of view. The 511 keV gamma-rays from electron-positron annihilation and 1809 keV gamma-rays from the radioactive decay of Al-26 were observed to have fluxes of 8.9 x 10 exp -4 and 1.9 x 10 exp -4 ph/cm-s, respectively. Continuum emission was detected from 20 to 800 keV and preliminary results have been obtained for the spectrum. Below 120 keV this is well described by power law with a slope of -2.6. In the 120-250 keV band the spectrum contains a broad linelike feature. This is interpreted as the result of Compton backscattering of about 511 keV photons from a compact source of electron-positron annihilation radiation.

Matteson, J.↗

SALSA - A Synthesis Array for Lunar Submillimeter Astronomy

A conceptual design is described for a lunar submillimeter wavelength interferometer called SALSA, a Synthesis Array for Lunar Submillimeter Astronomy. Its design is greatly simplified over conventional submillimeter wavelength arrays because it takes advantage of a beam waveguide to relay signals to a centrally-located receiver system. The array is optimized to synthesize images at wavelengths between 60 and 300 microns, and it has an angular resolution of 10 milliarcsecs at 60 microns. Observations in this region provide unique insights into fundamental issues in astrophysics such as star formation, but are impossible from the earth's surface because of atmospheric absorption. The baseline design for SALSA consists of twelve, 3.5-meter diameter antennas arranged in a Y-shaped configuration consisting of three 0.5-km long arms, each with four antennas distributed according to a power-law function of distance. Such a beam-waveguide approach has significant advantages, since all the high-power-consumption items (active cryogenics, correlator) are at a central location and could share a single power source. In addition, the antennas can be quite simple and maintenance is greatly reduced. The primary technology challenges for developing such an array are the coherent detectors (mixers and local oscillator sources), and ensuring the dimensional stability of the optical elements under the extreme lunar thermal environment (85-385 K).

Mahoney, M. J.↗

Laer-induced Breakdown Spectroscopy Instrument for Element Analysis of Planetary Surfaces

One of the most fundamental pieces of information about any planetary body is the elemental and mineralogical composition of its surface materials. We are developing an instrument to obtain such data at ranges of up to several hundreds of meters using the technique of Laser-Induced Breakdown Spectroscopy (LIBS). We envision our instrument being used from a spacecraft in close rendezvous with small bodies such as comets and asteroids, or deployed on surface-rover vehicles on large bodies such as Mars and the Moon. The elemental analysis is based on atomic emission spectroscopy of a laser-induced plasma or spark. A pulsed, diode pumped Nd:YAG laser of several hundred millijoules optical energy is used to vaporize and electronically excite the constituent elements of a rock surface remotely located from the laser. Light emitted from the excited plasma is collected and introduced to the entrance slit of a small grating spectrometer. The spectrally dispersed spark light is detected with either a linear photo diode array or area CCD array. When the latter detector is used, the optical and spectrometer components of the LIBS instrument can also be used in a passive imaging mode to collect and integrate reflected sunlight from the same rock surface. Absorption spectral analysis of this reflected light gives mineralogical information that provides a remote geochemical characterization of the rock surface. We performed laboratory calibrations in air and in vacuum on standard rock powders to quantify the LIBS analysis. We performed preliminary field tests using commercially available components to demonstrate remote LIBS analysis of terrestrial rock surfaces at ranges of over 25 m, and we have demonstrated compatibility with a six-wheeled Russian robotic rover vehicle. Based on these results, we believe that all major and most minor elements expected on planetary surfaces can be measured with absolute accuracy of 10-15 percent and much higher relative accuracy. We have performed preliminary systems analysis of a LIBS instrument to evaluate probable mass and power requirements; results of this analysis are summarized.

Blacic, J.↗

Solar Rotating Fourier Telescope

Proposed telescope based on absorbing Fourier-transform grids images full Sun at unprecedented resolution. Overcomes limitations of both conventional optical and pinhole cameras. Arrays of grids and detectors configured for sensitivity to selected fourier components of x-ray images.

Campbell, Jonathan↗

Linear encoding device

A Linear Motion Encoding device for measuring the linear motion of a moving object is disclosed in which a light source is mounted on the moving object and a position sensitive detector such as an array photodetector is mounted on a nearby stationary object. The light source emits a light beam directed towards the array photodetector such that a light spot is created on the array. An analog-to-digital converter, connected to the array photodetector is used for reading the position of the spot on the array photodetector. A microprocessor and memory is connected to the analog-to-digital converter to hold and manipulate data provided by the analog-to-digital converter on the position of the spot and to compute the linear displacement of the moving object based upon the data from the analog-to-digital converter.

Leviton, Douglas B.↗

Determination of geometric distortion in STIS images

This is a report on the characterization of the geometric distortion of the Space Telescope Imaging Spectrograph (STIS) Charge Coupled Devices (CCD) and the STIS Far-Ultraviolet Multi-Anode Microchannel Arrays (FUV-MAMA) detectors when used in imaging mode. We find that the amount of the distortion is fairly small over most of the field. The maximum displacement is 1.66 pixels for the CCD and 2.71 pixels for the FUV-MAMA. This data also allows us to determine the plate scale for both cameras. For the CCD the scale is 0".05071 +/- 0".00007 /pixel. For the FUV-MAMA the scale is 0".02447 +/- 0".00001 /pixel in x and 0".02467 +/-0".00002 /pixel in y.

Malumuth, Eliot M.↗

Characterization of Electronic Materials HgZnSe and HgZnTe Using Innovative and Conventional Techniques

HgZnSe and HgZnTe are electronic materials of interest for potential IR detector and focal plane array applications due to their improved strength and compositional stability over HgCdTe, but they are difficult to grow on Earth and to fully characterize. Conventional contact methods of characterization, such as Hall and van der Paw, although adequate for many situations are typically labor intensive and not entirely suitable where only very small samples are available. To adequately characterize and compare properties of electronic materials grown in low earth orbit with those grown on Earth, innovative techniques are needed that complement existing methods. This paper describes the implementation and test results of a unique non-contact method of characterizing uniformity, mobility, and carrier concentration together with results from conventional methods applied to HgZnSe and HgZnTe. The innovative method has advantages over conventional contact methods since it circumvents problems of possible contamination from alloying electrical contacts to a sample and also has the capability to map a sample. Non- destructive mapping, the determination of the carrier concentration and mobility at each place on a sample, provides a means to quantitatively compare, at high spatial resolution, effects of microgravity on electronic properties and uniformity of electronic materials grown in low-Earth orbit with Earth grown materials. The mapping technique described here uses a 1mm diameter polarized beam of radiation to probe the sample. Activation of a magnetic field, in which the sample is placed, causes the plane of polarization of the probe beam to rotate. This Faraday rotation is a function of the free carrier concentration and the band parameters of the material. Maps of carrier concentration, mobility, and transmission generated from measurements of the Faraday rotation angles over the temperature range from 300K to 77K will be presented. New information on band parameters, obtained by combining results from conventional Hall measurements of the free carrier concentration with Faraday rotation measurements, will also be presented. One example of how this type of information was derived is illustrated in the following figure which shows Faraday rotation vs wavelength modeled for Hg(l-x)ZnxSe at a temperature of 300K and x=0.07. The plasma contribution, total Faraday rotation, and interband contribution to the Faraday rotation, are designated in the Figure as del(p), FR tot, and del(i) respectively. Experimentally measured values of FR tot, each indicated by + , agree acceptably well with the model at the probe wavelength of 10.6 microns. The model shows that at the probe wavelength, practically all the rotation is due to the plasma component, which can be expressed as delta(sub p)= 2pi(e(sup 3))NBL/c(sup 2)nm*(sup 2) omega(sup 2). In this equation, delta(sub p) is the rotation angle due to the free carrier plasma, N is the free carrier concentration, B the magnetic field strength, L the thickness of the sample, n the index of refraction, omega the probe radiation frequency, c the speed of light, e the electron charge, and m* the effective mass. A measurement of N by conventional techniques, combined with a measurement of the Faraday rotation angle allows m* to be accurately determined since it is an inverse square function.

Tanton, George↗

Final Qualification and Early On-Orbit Performance of the HESSI Cryocooler

The High Energy Solar Spectroscopic Imager (HESSI) spacecraft was launched on February 5, 2002. It now observes the Sun with the finest angular and energy resolutions ever achieved from a few keV to hundreds of keV, using an array of nine germanium detectors operating at 75K. The spacecraft was originally scheduled for launch in July 2000, but a vibration facility mishap damaged the primary structure of the spacecraft, along with the cryocooler, This paper describes issues in the qualification of a replacement for the original flight cooler, and describes early on-orbit performance.

Boyle, R. F.↗