Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Data reduction methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,405 records · Page 78

Deep Learning for Unsupervised Insider Threat Detection in Structured Cybersecurity Data Streams

Situational awareness data is a prototypical example of structured heterogeneous streaming data with asynchronous timing that can quickly scale beyond the cognitive power of a human analyst. We present deep learning methods that can train in real time from unlabeled streams and provide probabilistic anomaly scores. We compare our novel deep and recurrent neural network models to three baseline systems using threat detection recall on the CERT Insider Threat Dataset v6.2. In our experiments, our deep neural network and our recurrent neural network systems outperformed all baselines, and we found that using aggregated activity count features yielded the best performance. Our best model produces on average an anomaly score of 95.53 percentile for the day, suggesting it can facilitate a great reduction in analyst workload. Our models are also interpretable, in that they break down the anomaly score into individual features of user behavior, which could further aid analysts in reviewing potential cases of insider threat.

Tuor, Aaron R.↗

Intelligent load pattern modeling and denoising using improved variational mode decomposition for various calendar periods

This paper proposes a novel approach to identify the load patterns considering calendar impact and denoising process, which advances the state of art of load identification and load forecasting to a more flexible and adaptive extent by revealing the correlation between load profile and the substantial influence factors. With the rapid development and the promising application of energy intemet and grid modernization, the accurate load modeling and forecasting especially by load pattern modeling (LPM) have become more and more critical to observe and estimate load profile so as to optimize the operation efficiency of the power grid. Traditional methods mostly focus on the static LPM itself which are unable to account the non-linear and highly dynamic load fluctuations in order to balance the demand of the power grid during various calendar period (VCP) scheduling. In this paper, a load pattern modeling method for power grid considering the impact of typical calendar effects is proposed using a combination of improved variational mode decomposition (IVMD) and deep belief network (DBN) algorithm. Firstly, an index of load curve curvature (LCC) is proposed to improve the selection of value K in the conventional VMD algorithm. The value K of the intrinsic modality is determined by adopting LCC to better quantify the average instantaneous frequency of the modal decomposition of the VMD and to reduce the elevated stochasticity of k. Secondly, an optimization formulation is developed based on adaptive segmented loop decomposition of the typical correlation coefficient to suppress the edge effect in VMD decomposition, which would enable the reconstructed curve to incorporate the variabilities from the initial data. Finally, the IVMD and DBN algorithms are jointly implemented to optimize the accuracy of VCP load pattern modeling curve regression. Numerical examples have been performed with the results proving that the proposed method significantly outperforms the state-of-art in reducing the modeling error of VCP load curve, improving the overall forecasting accuracy, and reducing load dispatching cost.

deep belief network↗

Measurement of θ 13 in Double Chooz using neutron captures on hydrogen with novel background rejection techniques

We observed a measurement of the Double Chooz collaboration and the neutrino mixing angle θ 13 using reactor $\bar{v}$ e via the inverse beta decay reaction in which the neutron is captured on hydrogen. Our measurement is based on 462.72 live days data, approximately twice as much data as in the previous such analysis, collected with a detector positioned at an average distance of 1050 m from two reactor cores. Several novel techniques have been developed to achieve significant reductions of the backgrounds and systematic uncertainties. Accidental coincidences, the dominant background in this analysis, are suppressed by more than an order of magnitude with respect to our previous publication by a multi-variate analysis. Furthermore, these improvements demonstrate the capability of precise measurement of reactor $\bar{v}$ e without gadolinium loading. Spectral distortions from the $\bar{v}$ e reactor flux predictions previously reported with the neutron capture on gadolinium events are confirmed in the independent data sample presented here. A value of sin 2 2θ 13 = 0.095 0.039 +0.038 (stat+syst) is obtained from a fit to the observed event rate as a function of the reactor power, a method insensitive to the energy spectrum shape. A simultaneous fit of the hydrogen capture events and of the gadolinium capture events yields a measurement of sin 2 2θ 13 = 0.088 ± 0.033(stat+syst).

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Sampling dynamics for pressurized electrochemical cells

A model describing the gas distribution within a constant pressure electrolysis system and how the distribution impacts electrochemical efficiencies is presented. The primary system of interest is the generation of syngas (CO and H2) associated with the co-electrolysis of H2O and CO2. The model developed for this system takes into account the primary process variables of operation including total system pressure, applied current, the in-flow of reactant gases. From these, and the chemical equilibria within the system, the impact on electrochemically generated gases is presented. Comparing the predicted and measured faradaic efficiency of electrode processes with the expected efficiency from experimental data indicates an offset between the two exists. Methods to minimize and account for the discrepancy are presented with the goal of being able to discern, in a real time manner, degradation of electrode performance. Comparison of the model to experimental data shows a strong correlation between the two with slight variation in experimental data which is attributed to reversible system dynamics such as wetting of the gas diffusion electrode used as the cell cathode.

10 SYNTHETIC FUELS↗

An algorithm for resolving intragranular orientation fields using coupled far-field and near-field high energy $\mathrm{X}$-ray diffraction microscopy

Here, we present a novel algorithm for reconstructing spatial intragranular lattice orientation fields using both far-field and near-field high energy X-ray diffraction microscopy (HEDM) measurements. An established far-field indexing algorithm is modified to include lattice orientation distribution information (grain orientation envelopes) in addition to average grain orientations. The near-field data reduction algorithm utilizes this enriched far-field orientation data as a seed for reconstructing intragranular spatial maps of lattice orientation from the diffraction images. The primary benefit of the new algorithm is a significant decrease in the number of trial calculations that must be performed in the reconstruction process compared to existing methodologies while maintaining scalability. The resulting gains in efficiency facilitate the use of relatively modest computational resources and improve throughput at the point of measurement. We provide two example applications: volumetric orientation field reconstructions for a Ti-Al alloy both before and after the application of 3% uniaxial strain. The results showcase the efficiency of the new method and the ability to resolve subtle changes in microstructure, which are associated with incipient plastic deformation.

36 MATERIALS SCIENCE↗

Risk-based decision making for staggered bioterrorist attacks : resource allocation and risk reduction in "reload" scenarios.

Staggered bioterrorist attacks with aerosolized pathogens on population centers present a formidable challenge to resource allocation and response planning. The response and planning will commence immediately after the detection of the first attack and with no or little information of the second attack. In this report, we outline a method by which resource allocation may be performed. It involves probabilistic reconstruction of the bioterrorist attack from partial observations of the outbreak, followed by an optimization-under-uncertainty approach to perform resource allocations. We consider both single-site and time-staggered multi-site attacks (i.e., a reload scenario) under conditions when resources (personnel and equipment which are difficult to gather and transport) are insufficient. Both communicable (plague) and non-communicable diseases (anthrax) are addressed, and we also consider cases when the data, the time-series of people reporting with symptoms, are confounded with a reporting delay. We demonstrate how our approach develops allocations profiles that have the potential to reduce the probability of an extremely adverse outcome in exchange for a more certain, but less adverse outcome. We explore the effect of placing limits on daily allocations. Further, since our method is data-driven, the resource allocation progressively improves as more data becomes available.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Adsorption of V on a Hematite (0001) Surface and its Oxidation: Monolayer Coverage

The adsorption of a monolayer of V on idealized Fe- and oxygen-terminated hematite (0 0 0 1) surfaces and subsequent oxidation under atomic O adsorption are studied by density functional theory. Theoretical results are compared with X-ray surface standing wave and X-ray photoelectron spectroscopic measurements, and interpreted in the light of data on sub-monolayer coverages. Near-surface Fe reduction under V adsorption and accompanying structural relaxation are examined. These effects and subsequent response to oxidation, are found to be highly site specific. A full monolayer of oxygen leads to a V{sup 5+} state and reoxidation of subsurface Fe to the trivalent state, seen in both theory and experiment.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Electronic structure of C and N co-doped TiO{sub 2}: A combined hard x-ray photoemission spectroscopy and density functional theory study

We have studied the electronic structure of C and N co-doped TiO{sub 2} using hard x-ray photoelectron spectroscopy and first-principles density functional theory calculations. Our results reveal overlap of the 2p states of O, N, and C in the system which shifts the valence band maximum towards the Fermi level. Combined with optical data we show that co-doping is an effective route for band gap reduction in TiO{sub 2}. Comparison of the measured valence band with theoretical photoemission density of states reveals the possibility of C on Ti and N on O site.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Carrier dynamics in blue, cyan, and green InGaN/GaN LEDs measured by small-signal electroluminescence

We study the carrier dynamics for c-plane InGaN/GaN light-emitting diodes (LEDs) with various emission wavelengths near the green gap using a small-signal electroluminescence method. The LEDs were grown by Lumileds using state-of-the-art growth conditions. Radiative and non-radiative recombination rates are numerically separated, and the carrier recombination lifetime and carrier density are obtained. Experiment shows that the causes of efficiency reduction at longer wavelength in the present structures are injection efficiency decrease, radiative recombination rate decrease, and imbalance of the increase in Auger–Meitner and radiative terms due to the interplay between the carrier–current density relationship and the quantum-confined Stark effect (QCSE). Here, the effects of QCSE, phase-space filling, and the carrier–current density relationship on efficiency reduction at longer wavelengths are examined separately with experimental data and Schrödinger–Poisson calculations. In addition, we confirm the scaling law between C(n) and B(n) under electrical injection and find that the increase in carrier density at a given current density is the primary cause for lower radiative efficiency at high current density in longer wavelength LEDs. Conversely, we do not observe a significant efficiency reduction at longer wavelengths from extrinsic material degradation.

42 ENGINEERING↗

Optimal Control of Differentially Private EV Charging: A Scalable Learning Approach Under Uncertainty

Internet of Things (IoT)-enabled electric vehicles (IoEVs) enable intelligent charging coordination that accounts for grid congestion. However, increased data exchange raises privacy concerns, as charging patterns can reveal sensitive driver behavior to grid operators. Here, we propose a differentially private (DP) EV charging framework that enables coordinated control while protecting driver data with theoretical privacy guarantees. Nevertheless, integrating DP inevitably introduces uncertainty into the control strategy for EVs, which can lead to infeasible solutions. To tackle this challenge, we develop a feasible and scalable control algorithm based on constrained reinforcement learning (CRL) and convex hulls. While our framework is designed to handle the uncertainty introduced by DP, it is general and also applicable to other sources of uncertainty in EV charging, such as the stochastic nature of driver behavior and renewable variability. This ensures feasible and privacy-preserving coordination of EV charging at scale. Our method constructs convex hulls within the action space to guarantee feasibility under stochastic constraints and incorporates constraint reduction techniques to improve scalability. Case studies based on IEEE benchmark systems demonstrate that the proposed approach effectively balances feasibility under uncertainty, scalability, and privacy in large-scale EV charging control.

Engineering - Power transmission and distribution↗

Expected individual benefit of prophylactic platelet transfusions in hemato‐oncology patients based on bleeding risks

Abstract Background Prophylactic platelet transfusions prevent bleeding in hemato‐oncology patients, but it is unclear how any benefit varies between patients. Our aim was to assess if patients with different baseline risks for bleeding benefit differently from a prophylactic platelet transfusion strategy. Study design and methods Using the data from the randomized controlled TOPPS trial (Trial of Platelet Prophylaxis), we developed a prediction model for World Health Organization grades 2, 3, and 4 bleeding risk (defined as at least one bleeding episode in a 30 days period) and grouped patients in four risk‐quartiles based on this predicted baseline risk. Predictors in the model were baseline platelet count, age, diagnosis, disease modifying treatment, disease status, previous stem cell transplantation, and the randomization arm. Results The model had a c‐statistic of 0.58 (95% confidence interval [CI] 0.54–0.64). There was little variation in predicted risks (quartiles 46%, 47%, and 51%), but prophylactic platelet transfusions gave a risk reduction in all risk quartiles. The absolute risk difference (ARD) was 3.4% (CI −12.2 to 18.9) in the lowest risk quartile (quartile 1), 7.4% (95% CI −8.4 to 23.3) in quartile 2, 6.8% (95% CI −9.1 to 22.9) in quartile 3, and 12.8% (CI −3.1 to 28.7) in the highest risk quartile (quartile 4). Conclusion In our study, generally accepted bleeding risk predictors had limited predictive power (expressed by the low c‐statistic), and, given the wide confidence intervals of predicted ARD, could not aid in identifying subgroups of patients who might benefit more (or less) from prophylactic platelet transfusion.

Cornelissen, Loes L.↗

SU-F-I-77: Radiation Dose in Cardiac Catheterization Procedures: Impact of a Systematic Reduction in Pulsed Fluoroscopy Frame Rate

Purpose: To evaluate whether one small systematic reduction in fluoroscopy frame rate has a significant effect on the total air kerma and/or dose area product for diagnostic and interventional cardiac catheterization procedures. Methods: The default fluoroscopy frame rate (FFR) was lowered from 15 to 10 fps in 5 Siemens™ Axiom Artis cardiac catheterization labs (CCL) on July 1, 2013. A total of 7212 consecutive diagnostic and interventional CCL procedures were divided into two study groups: 3602 procedures from 10/1/12 –6/30/13 with FFR of 15 fps; and 3610 procedures 7/1/13 – 3/31/14 at 10 fps. For each procedure, total air kerma (TAK), fluoroscopy skin dose (FSD), total/fluoroscopy dose area products (TAD, FAD), and total fluoroscopy time (FT) were recorded. Patient specific data collected for each procedure included: BSA, sex, height, weight, interventional versus diagnostic; and elective versus emergent. Results: For pre to post change in FFR, each categorical variable was compared using Pearson’s Chi-square test, Odds ratios and 95% confidence intervals. No statistically significant difference in BSA, height, weight, number of interventional versus diagnostic, elective versus emergent procedures was found between the two study groups. Decreasing the default FFR from 15 fps to 10 fps in the two study groups significantly reduced TAK from 1305 to 1061 mGy (p<0.0001), FSD from 627 to 454 mGy (p<0.0001), TAD from 8681 to 6991 uGy × m{sup 2}(p<0.0001), and FAD from 4493 to 3297 uGy × m{sup 2}(p<0.0001). No statistically significant difference in FT was noted. Clinical image quality was not analyzed, and reports of noticeable effects were minimal. From July 1, 2013 to date, the default FFR has remained 10 fps. Conclusion: Reducing the FFR from 15 to 10 fps significantly reduced total air kerma and dose area product which may decrease risk for potential radiation-induced skin injuries and improve patient outcomes.

60 APPLIED LIFE SCIENCES↗

SU-F-J-183: Interior Region-Of-Interest Tomography by Using Inverse Geometry System

Purpose: The inverse geometry computed tomography (IGCT) composed of multiple source and small size detector has several merits such as reduction of scatter effect and large volumetric imaging within one rotation without cone-beam artifact, compared to conventional cone-beam computed tomography (CBCT). By using this multi-source characteristics, we intend to present a selective and multiple interior region-of-interest (ROI) imaging method by using a designed source on-off sequence of IGCT. Methods: All of the IGCT sources are operated one by one sequentially, and each projection in the shape of narrow cone-beam covers its own partial volume of full field of view (FOV) determined from system geometry. Thus, through controlling multi source operation, limited irradiation within ROI is possible and selective radon space data for ROI imaging can be acquired without additional X-ray filtration. With this feature, we designed a source on-off sequence for multi ROI-IGCT imaging, and projections of ROI-IGCT were generated by using the on-off sequence. Multi ROI-IGCT images were reconstructed by using filtered back-projection algorithm. All these imaging process of our study has been performed by utilizing digital phantom and patient CT data. ROI-IGCT images of the phantom were compared to CBCT image and the phantom data for the image quality evaluation. Results: Image quality of ROI-IGCT was comparable to that of CBCT. However, the distal axial-plane from the FOV center, large cone-angle region, ROI-IGCT showed uniform image quality without significant cone-beam artifact contrary to CBCT. Conclusion: ROI-IGCT showed comparable image quality and has the capability to provide multi ROI image within a rotation. Projection of ROI-IGCT is performed by selective irradiation, hence unnecessary imaging dose to non-interest region can be reduced. In this regard, it seems to be useful for diagnostic or image guidance purpose in radiotherapy such as low dose target localization and patient alignment. This research was supported by the Mid-career Researcher Program through NRF funded by the Ministry of Science, ICT & Future Planning of Korea (NRF-2014R1A2A1A10050270) and by the Radiation Technology R&D program through the National Research Foundation of Korea funded by the Ministry of Science, ICT & Future Planning (No. 2013M2A2A7038291)

60 APPLIED LIFE SCIENCES↗

Integrated FHR technology development: Tritium management, materials testing, salt chemistry control, thermal hydraulics and neutronics, associated benchmarking and commercial basis

This report summarizes the results of a 3-year Integrated Research Project (IRP) sponsored by the U.S. Department of Energy to address major technical challenges in the development of the Fluoride-salt-cooled High-temperature Reactor (FHR). The IRP universities included the Massachusetts Institute of Technology (MIT), the University of California at Berkeley (UCB), the University of Wisconsin (UW), and the University of New Mexico (UNM). The FHR is a new reactor concept less than 20 years old that combines (1) a clean fluoride salt coolant, (2) the graphite-matrix coated-particle fuel originally developed for High- Temperature Gas-Cooled Reactors and (3) passive decay heat removal systems from sodium fast reactors. The base-line design is a pebble-bed FHR that delivers heat between 600 to 700°C with a 7 Li 2 BeF 4 (flibe) salt coolant to the power cycle or industrial users. The Executive Summary describes what was accomplished and summarizes major conclusions. The main report contains stand-alone sections in each major area of work. Highlights are summarized below. Tritium. The coolant salt produces tritium necessitating understanding and control of tritium. Experimental work included measuring hydrogen uptake on carbon, tritium uptake during irradiation of graphite in 700°C salt and the permeability of tritium through metals with and without coatings. An FHR systems model was developed to predict tritium behavior and enable design of tritium control systems. The leading candidate for tritium removal from the flibe salt is carbon bed outside the reactor core. Thermal hydraulics and Neutronics. A 10-meter high FHR integral effects test facility, using Dowtherm A®, has been built and used to simulate the integral response of a representative FHR to improve understanding of FHR thermal hydraulics and validate thermal hydraulics codes used for the FHR. Neutronic analysis included code-to-code benchmarking, multiphysics modeling, uncertainty analysis for nuclear data uncertainties and shielding analysis. Twisted-tube heat exchangers were examined that may provide significant cost reductions because of their improved heat-transfer performance with liquid salts. The impacts on safety and design caused by uncertainties in physical properties of the salt were assessed with recommendations on where added physical property measurements are needed. Work began on understanding radiative heat transfer that becomes important in salt systems at higher temperatures. Materials. Static corrosion tests were conducted on graphite and materials in 700°C salt -- both in the UW laboratory and in the MIT reactor. In addition to static corrosion testing, a circulating salt corrosion loop was built and is operating. Methods to measure salt properties including redox were developed. The presence of carbon increases corrosion. With good redox control, the evidence indicates stainless steel can be used as a material of construction. Benchmarking. An additional series of workshops where held to enable benchmarking and comparison of results between different investigators. Commercialization. The FHR delivers higher average-temperature (~650°C) heat to the power cycle or industry than other reactors. This enables power cycles with lower-cost heat storage for variable electricity to the grid while the reactor operates at base-load -- providing a major competitive advantage by maximizing revenue from electricity sales. In October, 2016, a new startup company named Kairos Power was formed, and opened its first office in Jack London Square, Oakland, California, in January 2017. Kairos Power exists largely due to the work that was accomplished by this IRP and the previous DOE-funded FHR IRP that performed research on FHR technology from 2012 to 2015. In September, 2018, as this IRP is concluding, Kairos Power was staffed at 60 full time employees, working to develop technology derived from this IRP. Many of these employees worked with the IRP before joining Kairos Power 1 (https://kairospower.com). Other students and researchers from this IRP have joined other startup companies, including the Terrapower Molten Chloride Fast Reactor and the Terrestrial Energy development efforts.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Binning is Sinning (Supernova Version): The Impact of Self-calibration in Cosmological Analyses with Type Ia Supernovae

Recent cosmological analyses (e.g., JLA, Pantheon) of Type Ia supernovae (SNe Ia) have propagated systematic uncertainties into a covariance matrix and either binned or smoothed the systematic uncertainty vectors in redshift space. We demonstrate that systematic error budgets of these analyses can be improved by a factor of ~ 1.5 × with the use of unbinned and unsmoothed covariance matrices. To understand this, we employ a separate approach that simultaneously fits for cosmological parameters and additional self-calibrating scale parameters that constrain the size of each systematic. We show that the covariance-matrix approach and scale-parameter approach indeed yield equivalent results, implying that in both cases the data can self-calibrate certain systematic uncertainties, but that this ability is hindered when information is binned or smoothed in redshift space. We review the top systematic uncertainties in current analyses and find that the reduction of systematic uncertainties in the unbinned case depends on whether a systematic is solely degenerate with the cosmological model in redshift space or whether it can be described by additional correlations between supernova properties and luminosity. Furthermore, we show that the power of self-calibration increases with the size of the data set, which presents a tremendous opportunity for upcoming analyses of photometrically classified samples, like those of Legacy Survey of Space and Time (LSST) and the Nancy Grace Roman Telescope (NGRST). However, to take advantage of self-calibration in large, photometrically classified samples, we must first address the issue that binning is required in currently used photometric analysis methods.

79 ASTRONOMY AND ASTROPHYSICS↗

Simulated scatter performance of an inverse-geometry dedicated breast CT system

The purpose of this work was to quantify the effects of scatter for inverse-geometry dedicated breast CT compared to cone-beam breast CT through simulations. The inverse geometry was previously proposed as an alternative to cone-beam acquisition for volumetric CT. The inverse geometry consists of a large-area scanned-source opposite a detector array that is smaller in the transverse direction. While the gantry rotates, the x-ray beam is rapidly sequenced through an array of positions, acquiring a truncated projection image at each position. Inverse-geometry CT (IGCT) is expected to detect less scatter than cone-beam methods because only a fraction of the object is irradiated at any time and the fast detector isolates the measurements from sequential x-ray beams. An additional scatter benefit is the increased air gap due to the inverted geometry. In this study, we modeled inverse-geometry and cone-beam dedicated breast CT systems of equivalent resolution, field of view, and photon fluence. Monte Carlo simulations generated scatter and primary projections of three cylindrical phantoms of diameters 10, 14, and 18 cm composed of 50% adipose/50% glandular tissue. The scatter-to-primary ratio (SPR) was calculated for each breast diameter. Monte Carlo simulations were combined with analytical simulations to generate inverse-geometry and cone-beam images of breast phantoms embedded with tumors. Noise representing the photon fluence of a realistic breast CT scan was added to the simulated projections. Cone-beam data were reconstructed with and without an ideal scatter correction. The CNR between breast tumor and background was compared for the inverse and cone-beam geometries for the three phantom diameters. Results demonstrated an order of magnitude reduction in SPR for the IGCT system compared to the cone-beam system. For example, the peak IGCT SPRs were 0.05 and 0.09 for the 14 and 18 cm phantoms, respectively, compared to 0.42 and 1 for the cone-beam system. For both geometries, the effects of scatter on contrast-to-noise ratio (CNR) were small for the 10 cm diameter phantom. The inverse-geometry improved the CNR by factors of 1.16 for the 14 cm phantom and 1.48 for the 18 cm phantom compared to a cone-beam acquisition without scatter correction. When an ideal scatter correction was applied to the cone-beam acquisition, the IGCT CNR improvements were 1.03 and 1.25 for the 14 and 18 cm phantoms. Overall, the results suggest that the inverse geometry may be advantageous for dedicated breast CT, an application that requires high-contrast resolution, spatial resolution, and dose efficiency.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

GPU Data Access on Complex Geometries for D3Q19 Lattice Boltzmann Method

GPU performance of the lattice Boltzmann method (LBM) depends heavily on memory access patterns. When LBM is advanced with GPUs on complex computational domains, geometric data is typically accessed indirectly, and lattice data is typically accessed lexicographically in the Structure of Array (SoA) layout. Although there are a variety of existing access patterns beyond the typical choices, no study has yet examined the relative efficacy between them. Here, we compare a suite of memory access schemes via empirical testing and performance modeling. We find strong evidence that semi-direct addressing is the superior addressing scheme for the majority of cases examined: Semi-direct addressing increases computational speed and often reduces memory consumption. For lattice layout, we find that the Collected Structure of Arrays (CSoA) layout outperforms the SoA layout. When compared to state-of-the-art practices, our recommended addressing modifications lead to performance gains between 10-40% across different complex geometries, fluid volume fractions, and resolutions. The modifications also lead to a decrease in memory consumption by as much as 17%. Having discovered these improvements, we examine a highly resolved arterial geometry on a leadership class system. On this system we present the first near-optimal strong results for LBM with arterial geometries run on GPUs. We also demonstrate that the above recommendations remain valid for large scale, many device simulations, which leads to an increased computational speed and average memory usage reductions. To understand these observations, we employ performance modeling which reveals that semi-direct methods outperform indirect methods due to a reduced number of total loads/stores in memory, and that CSoA outperforms SoA and bundling due to improved caching behavior.

Herschlag, Gregory↗

The Negative Impact of Stark Law Exemptions on Graduate Medical Education and Health Care Costs: The Example of Radiation Oncology

Purpose: To survey radiation oncology training programs to determine the impact of ownership of radiation oncology facilities by non-radiation oncologists on these training programs and to place these findings in a health policy context based on data from the literature. Methods and Materials: A survey was designed and e-mailed to directors of all 81 U.S. radiation oncology training programs in this country. Also, the medical and health economic literature was reviewed to determine the impact that ownership of radiation oncology facilities by non-radiation oncologists may have on patient care and health care costs. Prostate cancer treatment is used to illustrate the primary findings. Results: Seventy-three percent of the surveyed programs responded. Ownership of radiation oncology facilities by non-radiation oncologists is a widespread phenomenon. More than 50% of survey respondents reported the existence of these arrangements in their communities, with a resultant reduction in patient volumes 87% of the time. Twenty-seven percent of programs in communities with these business arrangements reported a negative impact on residency training as a result of decreased referrals to their centers. Furthermore, the literature suggests that ownership of radiation oncology facilities by non-radiation oncologists is associated with both increased utilization and increased costs but is not associated with increased access to services in traditionally underserved areas. Conclusions: Ownership of radiation oncology facilities by non-radiation oncologists appears to have a negative impact on residency training by shifting patients away from training programs and into community practices. In addition, the literature supports the conclusion that self-referral results in overutilization of expensive services without benefit to patients. As a result of these findings, recommendations are made to study further how physician ownership of radiation oncology facilities influence graduate medical education, treatment patterns and utilization, and health care costs. Patients also need to be aware of financial arrangements that may influence their physician's treatment recommendations.

61 RADIATION PROTECTION AND DOSIMETRY↗