Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “DETECTOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,405 records · Page 78

A Simple Way to Overcome the Shortage of {sup 3}He Detectors in the IPEN/MB-01 Nuclear Reactor

The presented work shows the preliminary results of an experimental procedure to overcome the helium-3 detectors shortage in the IPEN/MB-01 nuclear reactor and be feasible the study of the high subcritical states with less sensitivity detectors. The main principle was employing the input logic nuclear module which was possible to execute logic operations with the neutron signals. Though these signals was possible to construct the Auto Power Spectral Densities (APSD) and obtain the Prompt Neutron Constant Decay (α). Two different kinds of thermal neutron detectors were used ({sup 3}He and BF{sub 3}). The arrangement was initially constituted by one of each type detector and, posteriorly, for a more complete data acquisition, in groups of two detectors for all subcritical configurations. The experiment was carried out using the control banks (BC-1 and BC-2) insertion to achieve all the subcritical states studied in this work. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Diamond dose rate detector testing at KURRI- A joint UK-Japan research project - 17126

Measurements of radiation dose rates in highly active environments, such as nuclear plant decommissioning or following a nuclear disaster, is challenging due to the extreme environments encountered and restricted access. Therefore, novel radiation detector technology is required to address these challenges. One such example of a radiation detection material is diamond, as it is able to withstand and measure high radiation intensities, is chemically inert and formable into extremely small, sensitive detectors. These detectors generate small currents when exposed to radiation, and if the radiation levels are high enough this can be measured. Testing of such detectors is not possible in routine laboratories due to the requirement to have high active radiation sources. However, through a new collaboration formed through the University of Bristol- Kyoto University bilateral symposia such facilities are accessible for UK researchers at Kyoto University Research Reactor Institute. This paper presents an overview of the collaborative research project, the accessible facilities for device manufacture and testing and some early results from radiation testing of diamond detectors at KURRI. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Collimated CZT Detector for Quantitative Gamma Assays - 17250

Cadmium-Zinc-Telluride [CZT] detectors for gamma spectroscopic measurements and room-temperature operation have had a long history of promising good performance. Very small detectors [0.05-0.5 cm{sup 3}] have been commercially available for many years, but their small size creates problems for spectroscopy because of very low photopeak efficiency, especially at medium and high energies. Large CZT [4-6 cm{sup 3}] detectors have been shown to work nicely in a research environment when complicated electronic and data processing algorithms are applied. We report here test results from a commercially available 1 cubic centimeter CZT detector housed in a portable custom Tungsten shield with a set of collimators with different apertures. The detector has 2-2.5% FWHM resolution at Cs-137 energies, and near-Gaussian shaped peaks. Efficiency calibrations can be quickly made for a wide variety of geometries using the ISOCS mathematical efficiency software. We show successful validation tests comparing accuracy of measurements on reference calibration point sources, line sources, and 200 liter drums. The low weight of the device [9 kg including the shield and collimator] and low power [powered via USB from the PC] makes these devices particularly suitable for human-deployed in-situ measurements of large objects containing medium levels of activity - e.g. characterization of objects encountered during decommissioning, emergency response, truck alarm investigation, or waste being shipped to a disposal facility. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Electronics Upgrades to the Green is Clean Phoswich Detector Systems and Programmatic Implementation at LANL - Phase II Completion - 18403

Los Alamos National Laboratory (LANL) radiological facilities produce low-density room trash that, in many cases, is not contaminated with radioactivity. It has been estimated that 50 to 90% of low-density room trash is free of radioactive contamination and eligible for inclusion in LANL's Green is Clean (GIC) program. The GIC program is a verification program for non-regulated waste from radiation controlled areas that has been actively segregated as nonradioactive through the use of the waste generator's acceptable knowledge. The GIC program has employed two large area Phoswich gamma ray detector systems (HERCULES and ZEUS) to verify that GIC candidate low-density waste contains no radioactivity above background. The large area (127 cm{sup 2}) Phoswich detectors consist of a thin NaI front crystal (3 mm thick) that is optically coupled to a thick CsI back crystal (50 mm thick). The scintillation properties of the two crystals are different enough to allow the system's electronic components to identify the origin of any pulse. The original systems utilize Nuclear Instrumentation Module (NIM) electronics to process the detector signals. The electronics currently in use by the systems are out of date and some components are no longer manufactured. In 2015, phase I upgrades to the GIC detector systems were completed. Phase I objectives included identifying more modern commercially available electronics that could replace the NIM electronics. A pulse shape discriminator (PSD) module, the Digital Gamma Finder (DGF) Pixie-4 made by XIA LLC, that fits in a compact National Instruments{sup TM} PXI chassis was identified to replace the majority of the original NIM bin electronics - a single Pixie-4 module replaces four NIM amplifiers and four NIM pulse shape analyzers (PSAs). Another phase I objective was to show that that new PSD could separate out the NaI and CsI detector signals in a manner equivalent to or better than the NIM electronics. Proof of concept was achieved in 2015 when a prototype upgrade system on ZEUS was built and tested and gating parameter settings were determined that successfully separated the NaI and CsI signals. Phase II required establishing a LabVIEW software interface with Pixie-4 electronics in lieu of the manufacturer provided Pixie-4 software called the Pixie Viewer. In addition, phase II included 1) final optimization of the gating parameters on the prototype Pixie-4 ZEUS system, 2) finalizing Requirements, Design and Test Plan documents, 3) LabVIEW software interface quality assurance (QA) testing, 4) setting up the HERCULES system with the Pixie-4 upgrade electronics, 5) check source and background calibration of both systems, 6) absolute efficiency determination on both systems and 7) procedure revisions and implementation of both systems into routine operations. In 2017 phase II was completed including the preparation of detailed Requirements, Design and Test Plan documents. The LabVIEW interface software that communicates and controls the Pixie-4 has been completed, merged with the preexisting LabVIEW operations software and fully tested. Gating parameter optimization, configuration of HERCULES with the Pixie-4 electronics, check source and background calibrations and absolute efficiency determinations have all been performed - quantitative results are presented in the full paper. For performance validation, comparison measurements of actual GIC bags on both the HERCULES system using the old NIM Bin electronics and the ZEUS system using the upgraded Pixie-4 electronics have been done and evaluated. Finally, procedure revisions and implementation of both systems into routine operations is currently in process and planned to be complete by the end of calendar year 2017. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Development of a Phoswich Neutron Detector with Energy Spectroscopy Capability

Neutron measurement technology is critical to the detection and identification of nuclear materials and sources. Portable neutron detectors that enable thermal neutron and fast neutron measurements with a single system are still an experimental area. The ability to employ three signatures (photons, thermal neutrons, and fast neutrons) simultaneously for identification provides an extra element of certainty in results. The energy of fast neutrons can also provide a unique spectral signature for source quantification. A phoswich detector is based on the use of two dissimilar scintillators with a single photomultiplier tube (PMT) for the purpose of radiation detection. Past development was focused primarily on the application of the multi-scintillator design to gamma-ray, alpha- and beta-particle measurements. To this end, the work presented here has focused on the development of a phosphor sandwich ('phoswich') detector capable of differentiating between photons, thermal neutrons, and fast neutrons. The portable phoswich neutron detector was designed using two solid-sate scintillators: the {sup 6}Li-loaded glass and the EJ-299-33A plastic. Experiments showed that detector provides simultaneously count rates of photons, thermal neutrons, and fast neutrons with the energy spectroscopy option. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A novel photomultiplier tube neutron time-of-flight detector

A traditional neutron time-of-flight (nTOF) detector used in inertial confinement fusion consists of a scintillator coupled with a photomultiplier tube (PMT). The instrument response function (IRF) of such a detector is dominated by the scintillator-light decay. At DT neutron yields larger than 1013 a novel detector consisting of a microchannel-plate photomultiplier tube in a housing without a scintillator (PMT nTOF) can be used to measure DT yield, ion temperature, and neutron velocity. Most of the neutron signal in PMT nTOF is produced from neutron interaction with a PMT window. The direct interaction of neutrons with MCP has negligible contribution. The elimination of the scintillator removes the scintillator decay from the instrument response function and makes the IRF of the PMT nTOF faster, which makes the ion temperature and neutron velocity measurements more accurate. Three PMT nTOFs were deployed on the OMEGA Laser System for the first time to diagnose inertial confinement fusion plasma. Here, the design details, characteristics, and calibration results of these detectors in DT implosions on OMEGA are presented. Recommendations on the use of different PMTs for specific applications are provided.

47 OTHER INSTRUMENTATION↗

Muon counting using silicon photomultipliers in the AMIGA detector of the Pierre Auger observatory

Here, AMIGA (Auger Muons and Infill for the Ground Array) is an upgrade of the Pierre Auger Observatory designed to extend its energy range of detection and to directly measure the muon content of the cosmic ray primary particle showers. The array will be formed by an infill of surface water-Cherenkov detectors associated with buried scintillation counters employed for muon counting. Each counter is composed of three scintillation modules, with a 10 m 2 detection area per module. In this paper, a new generation of detectors, replacing the current multi-pixel photomultiplier tube (PMT) with silicon photo sensors (aka. SiPMs), is proposed. The selection of the new device and its front-end electronics is explained. A method to calibrate the counting system that ensures the performance of the detector is detailed. This method has the advantage of being able to be carried out in a remote place such as the one where the detectors are deployed. High efficiency results, i.e. 98% efficiency for the highest tested overvoltage, combined with a low probability of accidental counting (~2%), show a promising performance for this new system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design, upgrade and characterization of the silicon photomultiplier front-end for the AMIGA detector at the Pierre Auger Observatory

AMIGA (Auger Muons and Infill for the Ground Array) is an upgrade of the Pierre Auger Observatory to complement the study of ultra-high-energy cosmic rays (UHECR) by measuring the muon content of extensive air showers (EAS). It consists of an array of 61 water Cherenkov detectors on a denser spacing in combination with underground scintillation detectors used for muon density measurement. Each detector is composed of three scintillation modules, with 10 m 2 detection area per module, buried at 2.3 m depth, resulting in a total detection area of 30 m 2 . Silicon photomultiplier sensors (SiPM) measure the amount of scintillation light generated by charged particles traversing the modules. In this paper, the design of the front-end electronics to process the signals of those SiPMs and test results from the laboratory and from the Pierre Auger Observatory are described. Compared to our previous prototype, the new electronics shows a higher performance, higher efficiency and lower power consumption, and it has a new acquisition system with increased dynamic range that allows measurements closer to the shower core. The new acquisition system is based on the measurement of the total charge signal that the muonic component of the cosmic ray shower generates in the detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The EXO-200 detector, part II: auxiliary systems

The EXO-200 experiment searched for neutrinoless double-beta decay of 136 Xe with a single-phase liquid xenon detector. It used an active mass of 110 kg of 80.6%-enriched liquid xenon in an ultra-low background time projection chamber with ionization and scintillation detection and readout. Here, this paper describes the design and performance of the various support systems necessary for detector operation, including cryogenics, xenon handling, and controls. Novel features of the system were driven by the need to protect the thin-walled detector chamber containing the liquid xenon, to achieve high chemical purity of the Xe, and to maintain thermal uniformity across the detector.

47 OTHER INSTRUMENTATION↗

ATHENA detector proposal—a totally hermetic electron nucleus apparatus proposed for IP6 at the Electron-Ion Collider

ATHENA has been designed as a general purpose detector capable of delivering the full scientific scope of the Electron-Ion Collider. Careful technology choices provide fine tracking and momentum resolution, high performance electromagnetic and hadronic calorimetry, hadron identification over a wide kinematic range, and near-complete hermeticity. This article describes the detector design and its expected performance in the most relevant physics channels. It includes an evaluation of detector technology choices, the technical challenges to realizing the detector and the R&D required to meet those challenges.

47 OTHER INSTRUMENTATION↗

High-energy X-ray imaging with a Germanium MM-PAD hybrid pixel detector

Germanium is a high-Z sensor material with excellent energy resolution and attractive properties for high-energy photon detection. Despite its advantages, the need for cryogenic operation and challenges in the fabrication of pixelated high-purity germanium have hindered the development of segmented detectors. We report on the fabrication and performance of a germanium imaging detector with 150 μm pixel pitch hybridized to the MM-PAD ASIC. The detector was capable of high-resolution radiographic imaging and has a fast temporal response. Additionally, we describe the detector's upper operating temperature limits using both the MM-PAD and MARS ASICs, achieving stable operation up to 130 K and 190 K, respectively.

36 MATERIALS SCIENCE↗

Impact of proton irradiation on 4H-SiC Low Gain Avalanche Detectors (LGADs)

Silicon carbide (SiC) particle detectors have the potential to provide time resolutions and robust performance in extreme environments which exceed that of silicon detectors. In this work 4H-SiC low gain avalanche detectors (LGADs) and complementary PiN diodes were irradiated with 2.5 GeV protons at fluences up to 3.33 × 10 14 p/cm 2 . The electrostatic performance of both irradiated and non-irradiated devices was evaluated using I-V and C-V measurements. Moreover, charge collection measurements using α particles were also conducted. SiC LGADs displayed a loss in rectification, high ON-state resistances >10 10 Ω-cm 2 , and the complete removal of gain when exposed to the highest proton fluence. Additionally, the reductions in capacitance and OFF-state current pointed to compensation of the gain layer as a gain reducing mechanism. The introduction of radiation-induced defects also hinders carrier acceleration, which reduces impact ionization and further gain reduction. LGADs exposed to a fluence of 1 × 10 14 p/cm 2 experienced a partial recovery in gain (originally having a value of ∼ 2) with a value of ∼ 1.65 when applying a bias of 500 V. Charge trapping was also seen in the reduction of charge collection efficiency (CCE) to ∼ 65% for the PiN diode. However, despite the reduction in device performance, the demonstration of a measurable signal after irradiation points to the potential of SiC LGAD detectors for future high energy physics applications.

43 PARTICLE ACCELERATORS↗

Charge readout electronics for the DUNE horizontal drift far detector: design and performance in ProtoDUNE-HD

DUNE (Deep Underground Neutrino Experiment) is a long-baseline neutrino oscillation experiment currently under construction, whose far detectors will be the largest liquid argon time projection chambers ever built. This detector design calls for custom-built cryogenic front-end electronics to meet its performance requirements. This paper describes the charge readout electronics that will be used in the DUNE horizontal drift (HD) far detector and presents performance results using data from the ProtoDUNE-HD detector, a 770 ton liquid argon time projection chamber operated at the CERN Neutrino Platform in 2024 that served as the final prototype of the DUNE HD design.

Front-end electronics for detector readout↗

A low cost network of spectrometer radiation detectors based on the ArduSiPM a compact transportable Software/Hardware Data Acquisition system with Arduino DUE

The necessity to use Photo Multipliers (PM) as light detector limited in the past the use of crystals in radiation handled device preferring the Geiger approach. The Silicon Photomultipliers (SiPMs) are very small and cheap, solid photon detectors with good dynamic range and single photon detection capability, they are usable to supersede cumbersome and difficult to use Photo Multipliers (PM). A SiPM can be coupled with a scintillator crystal to build efficient, small and solid radiation detector. A cost effective and easily replicable Hardware software module for SiPM detector readout is made using the ArduSiPM solution. The ArduSiPM is an easily battery operable handled device using an Arduino DUE (an open Software/Hardware board) as processor board and a piggy-back custom designed board (ArduSiPM Shield), the Shield contains all the blocks features to monitor, set and acquire the SiPM using internet network. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Joint measurement of the atmospheric muon flux through the Puy de Dome volcano with plastic scintillators and Resistive Plate Chambers detectors

The muographic imaging of volcanoes relies on the measured transmittance of the atmospheric muon flux through the target. An important bias affecting the result comes from background contamination mimicking a higher transmittance. The MU-RAY and TOMUVOL collaborations measured independently in 2013 the atmospheric muon flux transmitted through the Puy de Dôme volcano using their early prototype detectors, based on plastic scintillators and on Glass Resistive Plate Chambers, respectively. These detectors had three (MU-RAY) or four (TOMUVOL) detection layers of 1 m 2 each, tens (MU-RAY) or hundreds (TOMUVOL) of nanosecond time resolution, a few millimeter position resolution, an energy threshold of few hundreds MeV, and no particle identification capabilities. The prototypes were deployed about 1.3 km away from the summit, where they measured, behind rock depths larger than 1000 m, remnant fluxes of 1.83±0.50(syst)±0.07(stat) m –2 d –1 deg –2 (MU-RAY) and 1.95±0.16(syst)±0.05(stat) m –2 d –1 deg –2 (TOMUVOL), that roughly correspond to the expected flux of high-energy atmospheric muons crossing 600 meters water equivalent (mwe) at 18° elevation. This implies that imaging depths larger than 500 mwe from 1 km away using such prototype detectors suffer from an overwhelming background. These measurements confirm that a new generation of detectors with higher momentum threshold, time-of-flight measurement, and/or particle identification is needed. As a result, the MU-RAY and TOMUVOL collaborations expect shortly to operate improved detectors, suitable for a robust muographic imaging of kilometer-scale volcanoes.

79 ASTRONOMY AND ASTROPHYSICS↗

Dark matter directionality revisited with a high pressure xenon gas detector

An observation of the anisotropy of dark matter interactions in a direction-sensitive detector would provide decisive evidence for the discovery of galactic dark matter. Directional information would also provide a crucial input to understanding its distribution in the local Universe. Most of the existing directional dark matter detectors utilize particle tracking methods in a low-pressure gas time projection chamber. These low pressure detectors require excessively large volumes in order to be competitive in the search for physics beyond the current limit. In order to avoid these volume limitations, we consider a novel proposal, which exploits a columnar recombination effect in a high-pressure gas time projection chamber. The ratio of scintillation to ionization signals observed in the detector carries the angular information of the particle interactions. In this paper, we investigate the sensitivity of a future directional detector focused on the proposed high-pressure Xenon gas time projection chamber. We study the prospect of detecting an anisotropy in the dark matter velocity distribution. We find that tens of events are needed to exclude an isotropic distribution of dark matter interactions at 95% confidence level in the most optimistic case with head-to-tail information. However, one needs at least 10-20 times more events without head-to-tail information for light dark matter below ~50 GeV. For an intermediate mass range, we find it challenging to observe an anisotropy of the dark matter distribution. Our results also show that the directional information significantly improves precision measurements of dark matter mass and the elastic scattering cross section for a heavy dark matter.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The simulation on absorption properties of metamaterial/GaAs/electrode layer hybrid structure based Terahertz photoconductive detector

Terahertz (THz) photodetectors have attracted great attention from scientists worldwide for their application in security checking, biomedical treatment and astronomical observation of remote stars and distant galaxies. As a typical THz detector, extrinsic GaAs based photoconductive detector is facing critical technical bottlenecks in the epitaxial growth of sufficiently thick and high-quality GaAs absorption layer. In this work, a novel THz photoconductive detector based on metamaterial/GaAs/electrode layer hybrid structure was designed and simulated. By setting the periodic split ring resonator (SRR) structure as 88 μm pitch with 8 μm width, the absorption peaks exist at the wavelength of about 142 and 367 μm, which originate from the resonant cavity and the SRR dipole resonance effect, and the novel device shows a significant enhancement compared with the conventional GaAs photoconductive detector. Thus, the necessary thickness of GaAs absorption-layer is largely reduced, and the resonant absorption peak can be modulated by changing the thickness of absorption layer. This work provides a novel device structure which can solve the critical epitaxial growth bottleneck of GaAs photoconductive detector and used for the astronomical observation, security check, etc.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Optimization of the frequency response of a novel GaAs plasmonic terahertz detector

Previously there was reported a new type of high-speed plasmonic THz detector that can operate at room temperature. As an extension of that work, the sensitivity of the detector was investigated over a wide range of sub-THz frequencies. The measured frequency response is not purely monotonic but exhibits oscillatory behaviour with a number of maxima and minima. Our study reveals that such frequency dependence is caused by the interference of electromagnetic waves inside the detector substrate, as the frequencies of these extrema are found to be governed by the substrate thickness. We demonstrate that sensitivity of this type of detector can be optimized for the desired operating frequency within 0.06–0.7 THz spectrum by adjusting the substrate thickness. We also show that a monotonic frequency response with eliminated minima can be achieved by mounting the detector on a specially designed silicon lens.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗