Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Counties”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,405 records · Page 78

OPALCO - Decatur Island Solar and Energy Storage Project: An Assessment of Battery Technical Performance

Orcas Power & Light Cooperative (OPALCO) is a member-owned, nonprofit cooperative utility that provides energy services to approximately 11,200 customers across 20 islands in San Juan County, Washington. OPALCO’s mostly hydroelectric power is generated by Bonneville Power Administration and delivered to the islands by submarine cables. In 2016, as part of the second round of funding from the Washington state Clean Energy Fund, OPALCO received a $1 million matching grant to support a project that deployed a 504-kW LG community photovoltaic (PV) system in combination with a 1 MW/2 MWh lithium-iron-phosphate battery energy storage system (BESS) on Decatur Island, Washington. The Decatur Island Substation is essential to ensuring reliable energy for the residents of the San Juan Islands as it is the point of interconnection with the mainland transmission system. The BESS, in combination with the community solar array, will deliver an innovative method to both defer the costly upgrade of the transmission system and allow for other high-value applications intended to benefit the utility and its customers. In 2018, Pacific Northwest National Laboratory (PNNL) completed a preliminary economic assessment for several identified use cases in collaboration with OPALCO. Between August 2021 and May 2022, extensive testing was conducted, and the results were used to assess the technical performance of the BESS subjected to actual field operations. Both reference performance and use case tests were performed: (a) Reference performance tests assess the general technical capabilities of the BESS, such as energy capacity, round-trip efficiency (RTE), ramp rate, and signal tracking capability. These are the first tests performed (baseline) and are repeated after use case tests (post cycle). A standardized U.S. Department of Energy (DOE) energy storage performance protocol was used to characterize the BESS, including representative duty cycle profiles, test procedure guidance, and calculation guidance for determining key characteristics. (b) Use case tests examine the performance of the BESS for specific use cases using duty cycles developed by PNNL in collaboration with OPALCO. Four use cases were selected for testing: 1) demand charge reduction, 2) load shaping, 3) outage mitigation, and 4) transmission deferral. The use case duty cycles were developed based on utility and site-specific characteristics in addition to the technical characteristics and physical capabilities of the BESS. Use case tests were performed between the baseline and post cycle tests. This report describes the BESS and its components, presents testing and performance analysis results, and shares key insights and lessons learned from this project. Outcomes of the tests and analyses will help OPALCO understand the performance of the Decatur Island BESS in its current state and design appropriate operational strategies for this and other BESSs over the long term.

14 SOLAR ENERGY↗

Distributed Wind Development Potential at United States Correctional Facilities

The goal of this assessment was to provide a high-level overview of distributed wind development potential at correctional facilities across the United States. The assessment considered the wind resource, electricity rates, and electricity consumption at facilities. In total, Pacific Northwest National Laboratory (PNNL) estimates that 2,421 facilities in 1,280 counties, projected to consume a combined 12,000 GWh/year, have the potential to host distributed wind projects.

17 WIND ENERGY↗

TRACER-Uncrewed Aircraft System (TRACER-UAS) Field Campaign Report

Convective processes drive the development of clouds across a variety of scales, thereby playing a central role in governing weather and climate globally. These processes help to set the stage for circulations that redistribute heat and moisture throughout the lower atmosphere, and simultaneously develop storms that supply precipitation to regions that depend on such rain events for supporting a variety of societal needs. At the same time, extreme precipitation events can result in localized flooding of low-lying areas, posing hazards to transportation and regional inhabitants, and potentially damaging structures and infrastructure. As a result, there is an inherent need to better understand the drivers and modulators of clouds and precipitation and leverage such understanding to make projections of how these important systems may evolve with a changing climate. With nearly three billion of Earth’s human inhabitants living within 200 km of a shoreline, development of such understanding is particularly important in coastal regimes. Central drivers of convective cloud development and life cycle in coastal environments include synoptic forcing, local meso- and microscale circulation regimes, microphysical evolution, and aerosol properties. Atmospheric boundary layer (ABL) development and its evolution can help drive the formation and organization of convective clouds, which then impart their own controls through dynamic processes related to latent heating and cooling (including cold-pool formation and propagation), three-dimensional radiative effects, and background environmental conditions (Fan et al. 2016). Such clouds have been contributing to record precipitation events in southeast Texas in recent years, relative to the last several decades of data from regional precipitation gauges (Fagnant et al. 2020). The greater Houston urban area has experienced particularly large increases in the frequency of extreme rainfall events, with enhanced intensity of extreme events (stretching of distribution tails) having potentially significant implications for watershed floodplain planning and mapping in greater Houston and Harris County. While the most extreme precipitation events were associated with tropical cyclones (e.g., Tropical Storm Allison and Hurricane Harvey; Blood 2014, Kao et al. 2019), strong thunderstorms can also deliver large amounts of precipitation over the area over relatively short periods.

54 ENVIRONMENTAL SCIENCES↗

Territorial Economic Impact Index: Measuring the ongoing effects of long-term disruptions to Pacific Island Territories

The Territorial Economic Impact Index (TEII) estimates the change in overall territory-level economic activity during the COVID-19 pandemic relative to January 2020. It shows which Pacific Island Territories may be more susceptible to large reductions in economic activity compared to normal conditions by looking at which industries make up each territory’s economy and then tracking monthly changes in industry employment at the U.S. national level. Economic activity in the TEII is measured by the total value added of all industries within the territory. Territories with economic activities dominated by industries experiencing rising unemployment can expect larger direct impacts to their local economies, particularly if the industries account for a large portion of the economic output of that county. Results are available for all three Pacific Island Territories: American Samoa, Guam, and the Commonwealth of the Northern Mariana Islands.

99 GENERAL AND MISCELLANEOUS↗

Computed Tomography Scanning and Petrophysical Measurements of the Lively Grove #1 Well Core

The computed tomography (CT) facilities and the Multi-Sensor Core Logger (MSCL) at the National Energy Technology Laboratory (NETL) in Morgantown, West Virginia were used to characterize core from the Lively Grove #1 Well (API 121892494700), drilled near Marissa, Washington County, Illinois. Core from the well was obtained as part of the Illinois Storage Corridor’s Carbon Storage Assurance Facility Enterprise (CarbonSAFE) project (DE FE0031892). The primary impetus of this work was to capture a detailed digital representation of the core from the Lively Grove #1 Well. The collaboration between the U.S. Department of Energy’s (DOE) NETL and the Illinois State Geological Survey (ISGS) enables other research entities to access information about this potential carbon storage location and Cambro-Ordovician Storage Complex formations of the Illinois Basin. The resultant datasets are presented in this report and can be accessed from NETL’s Energy Data eXchange (EDX) online system. All equipment and techniques used were non-destructive, enabling future examinations and analyses to be performed on these cores. Fractures, discontinuities, and millimeter-scale features were readily detectable with the medical CT scanner-acquired images. Imaging with the NETL medical CT scanner was performed on entire cores. Qualitative analysis of the medical CT images, coupled with X-ray fluorescence (XRF), gamma density, and magnetic susceptibility measurements from the MSCL were useful in identifying zones of interest for potential future analysis. Higher-resolution industrial and micro-CT images were acquired from selected zones along the depth of the core to visualize the structure in higher detail. The ability to quickly identify key areas for more detailed study with higher resolution will save time and resources in future studies. The combination of methods used provides a multi-scale analysis of the core; with the resulting macro- and micro-descriptions relevant to many subsurface energy related examinations traditionally performed at NETL.

54 ENVIRONMENTAL SCIENCES↗

2020 Postclosure Groundwater Monitoring and Inspection Report, Central Nevada Test Area, Subsurface Corrective Action Unit 443

This report presents the groundwater monitoring data collected by the U.S. Department of Energy (DOE) Office of Legacy Management (LM) from the Central Nevada Test Area (CNTA), Nevada, Site, Subsurface Corrective Action Unit (CAU) 443 in Nye County, Nevada (Figure 1). The CNTA is the site of an underground nuclear test in 1968 that resulted in residual contamination near the detonation depth of 3200 feet (ft); the contamination requires long-term monitoring. Responsibility for the environmental restoration and long-term monitoring was transferred from DOE’s National Nuclear Security Administration, Nevada Field Office, to LM on October 1, 2006. The environmental restoration and site closure process were completed in 2015 in accordance with the amended 1996 Nevada Federal Facility Agreement and Consent Order (FFACO) (State of Nevada et al. 1996, as amended) and all applicable Nevada Division of Environmental Protection (NDEP) policies and regulations. The Closure Report, Central Nevada Test Area, Subsurface Corrective Action, Unit 443 (DOE 2018), also called the Closure Report, originally was completed in January 2016 and revised in October 2018; it describes LM’s plan for long-term postclosure monitoring. This includes monitoring of the radioisotopes of interest and water elevations, inspecting the site and maintaining the institutional controls (ICs), evaluating and reporting data, and documenting the site’s records and data management processes (DOE 2018).

54 ENVIRONMENTAL SCIENCES↗

Plant Growth Study: Growth of Three Plant Species in 100-OL-1 Operable Unit Soils

Soil contamination from historical application of lead arsenate pesticides persists in the 100-OL-1 Operable Unit (OU) of the U.S. Department of Energy’s Hanford Site in Benton County, Washington. A remedial investigation used a portable X-ray fluorescence analyzer to estimate and map the concentrations of metals in surface soil in the 133 decision units comprising the OU. There is variability in lead and arsenic concentrations among the non-contiguous decision units, and an incomplete understanding of the ecological and human risks from soil contamination. While general screening criteria for lead are reported in literature, limited information is available on the impacts of heavy metals on site-specific plant and animal life. To address this information gap, a study on plant growth in Hanford soils was conducted using native bluegrass (Poa secunda), invasive cheatgrass (Bromus tectorum), and buttercrunch lettuce (Lactuca sativa). The latter is included because it is a common species used in plant growth studies. Soil samples were collected from a single general location within the 100-OL-1 OU, prepared, and categorized as having low, medium, or high concentrations of lead and arsenic, with the high concentration soil having concentrations of up to 3,400 and 790 mg/kg lead and arsenic, respectively. Additionally, a synthetic soil was prepared and used as a control, in accordance with standard plant growth protocols. Fifty-four seeds of each plant species were planted in each of the four soil types following the procedure outlined by the Washington State Department of Ecology. Germination rates and biomass measurements were recorded for 20 days. Both bluegrass and lettuce germination rates appeared to be reduced at the highest lead and arsenic concentrations (Pb: 3400 mg/kg, As: 790 mg/kg), while cheatgrass germination rates were unaffected. Total biomass for all species appeared to be related to the relative concentrations of lead and arsenic in the soil. Results of this growth study agree reasonably well with previous Hanford Site plant growth studies and provide additional data for assessing ecological risk at the Hanford Site.

54 ENVIRONMENTAL SCIENCES↗

Onshore U.S. Carbon Pipeline Deployment: Siting, Safety, and Regulation

Carbon capture, utilization, and storage (CCUS) technology has significant potential to reduce greenhouse gas (GHG) emissions and mitigate the impact of climate change, particularly in hard to decarbonize industrial and commercial sectors. CCUS involves capturing carbon dioxide (CO 2 ) from industrial processes or power generation and utilizing it for other purposes, such as enhanced oil recovery (EOR), or storing the captured CO 2 underground. CCUS technology can reduce the environmental impact of continued fossil fuel use while smoothing the transition to a low-carbon economy. CCUS can create new economic opportunities, such as the development of new industries and job creation, and can enhance energy security by diversifying energy sources. For these reasons, enabling CCUS has become a key objective of the Biden-Harris administration’s clean energy policy and has received bipartisan support. Despite its environmental and economic potential, CCUS faces multiple barriers to widespread deployment. One of the main challenges is the high cost and technical difficulty of implementing and operating large-scale CCUS infrastructure. CCUS remains a relatively expensive way to reduce carbon emissions (e.g., compared to solar photovoltaic technology’s displacement of coal generation). Additionally, financial incentives and supportive policies like those enacted to support solar photovoltaic development, especially at the state level, are inconsistent or nonexistent, which can discourage investment in CCUS projects. There are also technical challenges associated with safe and secure underground CO 2 storage and the development of new carbon utilization technologies. Public opposition to various aspects of CCUS technologies, ranging from concerns that CCUS will extend reliance on fossil fuels to CCUS infrastructure being sited in disadvantaged communities, is a growing challenge. This paper focuses on another significant barrier to broad CCUS deployment: the need for considerable expansion of the dedicated land-based CO 2 pipeline network in the United States to meet CCUS goals and the unique regulatory challenges to its development. To reach carbon emissions targets in the United States by 2050, CCUS technology will need to be supported by tens of thousands of miles of CO 2 pipelines. Estimates range from a minimum of roughly 29,000 pipeline miles (according to a 2020 Great Plains Institute study) to 66,000 pipeline miles (as per a 2021 Princeton University–led study). As of October 2022, however, the U.S. Department of Transportation (U.S. DOT) reports fewer than 5,400 miles of U.S. pipelines carrying CO 2 . This deficit—and what it means for the prospect of moving substantially larger quantities of CO 2 from source to use or storage—threatens to stifle the development of CCUS projects and technologies identified as an important tool to meet emissions targets. The current regulatory landscape facing CO 2 pipeline development can best be described as uncertain. At the federal level, the U.S. DOT Pipeline and Hazardous Materials Safety Administration (PHMSA) oversees safety regulation of pipelines transporting hazardous materials, including CO 2 upon commencement of operation. However, PHMSA’s definition of CO 2 as “a fluid consisting of more than 90 percent CO 2 molecules compressed to a supercritical state” has not been updated since its 1991 addition to the Federal Register. Because CO 2 can be transported in a gaseous, liquid, or supercritical state (indeed, the physical state of CO 2 can fluctuate within a single pipeline due to environmental changes), doubts persist about the extent of PHMSA’s purview—and raise questions about what, if anything, states should do to address this apparent gap. PHMSA has begun a major revision of its existing rules, but the agency does not expect a first draft before 2024. Economic oversight of CO 2 pipelines is even less clear. The Federal Energy Regulatory Commission (FERC) and Surface Transportation Board (STB)—which regulate the rates of interstate oil/natural gas and non-energy pipelines, respectively—have both declined jurisdiction over interstate CO 2 pipelines. This presumably leaves economic regulation to state and/or local governments, but few if any states have the laws or resources in place to oversee just and reasonable rates. Further, the interstate nature of CO 2 pipeline development creates questions around how different states should align their rate-making decisions. Onshore U.S. Carbon Pipeline Deployment: Siting, Safety, and Regulation Currently, regulatory responsibilities regarding CO 2 pipeline siting and permitting fall to state and local governments. The variety of laws and regulations across the country, however, creates a maze of requirements for pipeline developers to navigate. To secure necessary permits, most states require pipeline companies to be “common carriers” that provide transport service to the public at uniform rates. However, the specific definition of that term varies. Some states require clear evidence that a pipeline services the public, while others automatically deem any pipeline company transporting energy products or hazardous materials to be a “common carrier”—with little consideration for accessibility to third parties. Other states have eschewed common-carrier terminology entirely, placing private and publicly accessible pipelines on equal footing. Much like the variation in common-carrier requirements, laws governing eminent domain authority to secure rights-of-way (ROW) to commence construction on a planned pipeline route differ by state. Several states have no laws or rules governing CO 2 pipelines. In addition to creating questions about whether long-standing rules for other pipelines (e.g., natural gas or petroleum products) apply to CO 2 , this policy vacuum leaves local governments as the sole authority over sections of pipe within their boundaries. With dozens of counties along a given route, the probability of inconsistent regulation of the same pipeline is significant. Even in states with CO 2 pipeline laws in place, local regulatory attempts to address rising concerns over pipeline routing and safety have triggered lawsuits by pipeline companies seeking to delimit areas of federal, state, and local government responsibility. Meanwhile, legislators across the country have introduced bills to restrict the application of eminent domain to CO 2 pipeline projects, which could threaten a key means of securing ROW that companies cannot secure through negotiation with landowners. Taken separately, any of these regulatory issues—the narrow federal definition of CO 2 , FERC’s and STB’s decisions that CO 2 pipelines are not within their jurisdiction, and the considerable variation in state and local governments’ laws regulating CO 2 pipeline technologies—are extremely difficult to resolve. Adding the required scale of CO 2 pipeline expansion and the currently identified narrow window of time in which to reach climate target goals, the task becomes even more difficult—and raises a host of urgent questions for regulators. How should CO 2 be defined in federal regulations to ensure consistent safety standards across the country? What is the potential impact radius of a CO 2 pipeline rupture, and how should that inform local emergency response? In the absence of centralized federal oversight, what should state legislatures do to increase alignment for interstate CO 2 pipeline projects? This paper intends to serve as a primer for regulators and stakeholders who seek to better understand the regulatory challenges and opportunities facing this critical infrastructure.

42 ENGINEERING↗

Non-Fouling, Low Cost Electrolytic Coagulation & Disinfection for Treating Flowback and Produced Water for Reuse

Executive Summary This Final Report is composed of two major sections. The first section presents experimental results obtained in the laboratory during Budget Period 1. The second section presents results from the field test conducted during Budget Period 2. Laboratory Results This research investigated a novel electrochemical process for producing a ferric iron coagulant for use in treating flowback and produced water from hydraulic fracturing and oil production operations. The treatment system improves the effectiveness and lowers the cost of coagulation processes using Fe3+ as the coagulant. The electrolytic coagulant generation (ECG) system uses an electrochemical cell to produce acid and base from oilfield brine solutions. The acid is used to dissolve scrap iron to provide a Fe3+ coagulating agent. The base is used to neutralize the treated water. Compared to conventional electrocoagulation (EC), the main advantage of the ECG system is an order of magnitude lower cost for the source of iron. The second advantage over conventional EC is that it can deliver Fe3+ doses greater than 1 mM, since it is not limited by the amount of dissolved oxygen in the water required to oxidize ferrous to ferric iron. The capital costs for conventional EC and the ECG system are similar, but the operational costs for the ECG system are an order of magnitude lower than conventional EC. The combined costs for iron and electrical energy for treating 1 m3 of FPW with 1 mM Fe3+ is estimated to be $0.87 for conventional EC, and $0.087 for the ECG system. The estimated all-in cost for treating FPW with a 2 mM Fe3+ dose is $0.73/m3 ($0.12/bbl). Field Test Results The field test was conducted at the Paul Foster Central Tank Battery (CTB) in Lea County, New Mexico from November 10, 2022 through December 15, 2022. The feed water to the system was produced water from the Tatanka 1H formation. After approximately two weeks of testing, the initial batch of produced water had been treated and no untreated produced water was available. Thus, after this time, the feed water to the system consisted of previously treated water (i.e., recycled water). The recycled water had nearly all colloidal particles removed, and had a much lower alkalinity due to precipitation of carbonate minerals during the first pass through the system. Although the recycled water was not an ideal test solution due to its low particulate concentrations, its lower alkalinity did allow us to identify the main problem with the treatment system. The main problem with the treatment system was caused by the high alkalinity of the initial feed water (5.4 meq/L) that consumed a significant fraction of the electrochemically generated acid. This resulted in pH values exiting the iron contact tank that were too high to dissolve enough iron to effectively treat the produced water. Tests performed with recycled water with lower alkalinity did not have this issue, and dissolved iron concentrations greater than 20 mM could be achieved. One consistent observation was that effluent water from the iron contact tank was always free of particulates, even when fed with circumneutral solutions. This suggests that there is no need to dissolve high concentrations of iron if all the water to be treated is passed through the scrap iron canister. In this case, dissolved O2 and hypochlorous acid can promote sufficient iron corrosion to provide an effective coagulating agent – even in neutral pH water. This solves the problem resulting from highly alkaline produced water. Modifications to the design of the treatment system were made based on the field test results. These modifications will add minimal additional cost, and were tested in bench-scale laboratory experiments. In short-term testing, the modified treatment process was able to remove colloidal FeS particulates to levels below detection. Long-term, steady state testing will be required to determine whether the modified process is suitable for commercial treatment systems.

54 ENVIRONMENTAL SCIENCES↗

Graton Rancheria Solar G.R.E.E.N. Project (Final Report)

Final Technical Report Graton Rancheria Solar GREEN Project to install approximately 1.7 megawatts (MW) of rooftop solar to provide electricity to four Tribally owned buildings on Tribal trust land located in Sonoma County. The project is the first solar photovoltaic (PV) installation by the Tribe on Tribal lands and complement previously installed clean energy projects including multiple electric vehicle chargers located at the Tribe’s economic enterprise.

14 SOLAR ENERGY↗

Radiological Dispersal Device (RDD) Recovery Guidance: After Action Report from Pilots - Responding to Feedback from Pilots Reviewing RDD Recovery Guidance

The goal of this After Action report is to utilize feedback from the pilot participants to improve the guidance for responding to radiological dispersal device (RDD) events, which can include deliberate acts to release radioactive materials into the environment using explosives or other means or accidental releases (e.g., release from a medical isotope source). This longer-term recovery guidance is an extension of the initial response guidance that was released in a 2017 interagency report called RDD Response Guidance: Planning for the First 100 Minutes. Recovery teams reviewed the longer-term recovery guidance during pilot sessions that were held in Harris County, Texas (March 8-10, 2022) and Seattle, Washington (May 2-3, 2022). The pilot teams reviewed the RDD Recovery Guidance Presentation, which contains a summary of the more detailed RDD Recovery Guidance draft document. The feedback from both pilots was grouped and binned into unique themes (e.g., “checkpoint challenges”) that align with the recovery missions and tactics that they reviewed. PNNL authors of the recovery guidance then prepared responses that describe how they recommend addressing the feedback for each theme. The responses typically included recommendation plans for improving the guidance document, but also described when no changes are needed because the guidance already contains the suggested improvement. These pilot recommendations will be brought to the interagency team to finalize plans for updating and improving recovery guidance materials.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Surveillance of Site A and Plot M (Report for 2022)

The results of the environmental surveillance program conducted at Site A/Plot M for calendar year (CY) 2022 are presented within this document. Site A/Plot M is in the Palos Area Preserves, operated by the Forest Preserve District of Cook County. The surveillance program consists of the collection and analysis of surface and groundwater samples to determine the amount of hydrogen-3 and strontium-90 present in the environment within and surrounding the site of the former research facility (Site A) and waste burial site (Plot M).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Organic Waste Resource Assessment for the Detroit Region

This study summarizes major sources of organic wastes in the Detroit region to (1) characterize target feedstock magnitudes and distribution in support of techno-economic analysis (TEA), and (2) guide the design of blended feedstock conversion experiments using hydrothermal liquefaction (HTL). Feedstocks considered in this review include municipal wastewater sludge solids (untreated) and scum; bulk municipal solid waste (MSW); the organic fraction of municipal solid waste (OF-MSW); residential food waste, non-residential food waste including institutional, industrial, and commercial (IIC) sources; confined animal manures (i.e., lactating dairy, feedlot beef, and market swine); waste fats, oils and greases (FOG); agricultural residues; forest residues. The scope of the investigation was limited to existing modeled or publicly available reporting datasets. Bulk MSW data were only collected for context and to generate estimates of OF-MSW by waste type and should not be included in total organic waste estimates. Because the TEA analysis boundary was not defined prior to conducting the resource assessment, the data are summarized within six spatial contexts (boundaries), including (1) city of Detroit (census); (2) Great Lakes Water Authority (GLWA) service area; “Tri-county” urban area (census); “Metro” Detroit-Warren-Dearborn Metropolitan Statistical Area (MSA) (census); Detroit-Warren-Ann Arbor Combined Statistical Area (CSA) (census); and the Michigan Councils of Government (COG) Region-1. All of the spatial contexts are entirely within the State of Michigan, and some overlap one another. A broader context could be developed to include data from surrounding states or Canada.

09 BIOMASS FUELS↗

Preliminary Per- and Polyfluoroalkyl Substances Sampling Plan for Pantex Plant

Leidos prepared this Preliminary Per- and Polyfluoroalkyl Substances (PFAS) Sampling Plan for the U.S Department of Energy (DOE) Pantex Plant Consolidated Nuclear Security, LLC (CNS) Pantex, the operations and maintenance (O&M) contractor of Pantex Plant commissioned the Preliminary PFAS Sampling Plan to evaluate the potential risks at the facility and collect preliminary groundwater data at areas within the Plant with the highest potential for PFAS. This plan presents findings from research conducted to assess past and current use of materials containing PFAS and identify areas where these materials were potentially stored, handled, used, or released at Pantex Plant. Pantex Plant is located in Carson County in the Texas Panhandle (Figure 1-1).

54 ENVIRONMENTAL SCIENCES↗

The Port of Los Angeles Zero- and Near-Zero-Emission Freight Facilities "Shore to Store" Project (Final Project Report)

The City of Los Angeles Harbor Department (Harbor Department, POLA) partnered with Equilon Enterprises LLC (d/b/a Shell Oil Products US) (Shell), Toyota Motor North America (Toyota) and Kenworth Truck Company (Kenworth) partnered with the Port of Hueneme (POH), United Parcel Service (UPS), Total Transportation Services Inc. (TTSI), Southern Counties Express (SCE), Toyota Logistics Services (TLS), Air Liquide, National Renewable Energy Laboratory (NREL), Coalition For A Safe Environment, and the South Coast Air Quality Management District (South Coast AQMD) to introduce hydrogen (H 2 ) fuel into the Southern California drayage truck market by demonstrating near-commercial heavy-duty H 2 fuel cell electric trucks at and between freight facilities throughout the region, while continuing to lay the groundwork for battery-electric operations. The "Shore to Store" (S2S) project built on project team experience to help realize our vision of zero-emission freight operations in the future. Ten Kenworth zero-emission Class 8 fuel cell electric trucks, integrated with Toyota's fuel cell drive technology, were operated by UPS, TTSI, SCE, and TLS in revenue service. The demonstration fleet fueled at the S2S hydrogen fueling stations that were built in Ontario, California and Wilmington, California. An additional station at the Port of Long Beach (Portal Station) was available for fueling the fleet. Portal Station was supported by grants from the California Energy Commission (CEC) and South Coast AQMD and used as match funding for the S2S project. POH demonstrated two battery-electric yard tractors, and TLS demonstrated two zero-emission forklifts at their warehouse facility, showcasing elements of the entire supply chain operating on zero-emissions. This project showcased a snapshot of the zero-emission supply chain of the future, providing a model by which freight facilities can support zero-emission operations.

33 ADVANCED PROPULSION SYSTEMS↗

Historic Architectural Resource Survey of the Dosimetry Applications Research (DOSAR) Facility in the 7700 Area of the Oak Ridge National Laboratory

In May 2022, Cultural Resource Analysts, Inc., completed a historic architectural resource survey of buildings associated with the Dosimetry Applications Research Facility at the Oak Ridge National Laboratory. The laboratory is one of three Department of Energy facilities located on the Oak Ridge Reservation in Roane and Anderson Counties, Tennessee. The Dosimetry Applications Research Facility is located approximately 2 mi southeast of the main Oak Ridge National Laboratory campus. The survey included Buildings 7709, 7710, and 7712, which date to the 1960s. An additional DOSAR building (Building 7735) dates to the late 1980s and was not surveyed since it is outside the period of significance. The survey was conducted at the request of UT-Battelle, LLC, on behalf of the Department of Energy. As stipulated by the National Historic Preservation Act of 1966, as amended, the Department of Energy is required to identify any properties under its jurisdiction that are included in or eligible for inclusion in the National Register of Historic Places. In order to identify historic properties at the Oak Ridge National Laboratory, in 2017–2018 Cultural Resource Analysts, Inc., conducted a survey of the main campus as well as outlying facilities, publishing the findings in a 2018 report entitled Oak Ridge National Laboratory Historic Architectural Resource Survey. At the time of the 2017–2018 survey, buildings associated with the Dosimetry Applications Research Facility were not accessible for security reasons and the current report serves as an addendum to the 2018 report. In addition, the current survey incorporates information included in a documentation report on Building 7709 completed in 2019. The properties included in the current survey were also evaluated for their collective potential as a historic district. The identification of archaeological properties that are eligible for inclusion in the National Register of Historic Places is beyond the scope of this report. Cultural Resource Analysts, Inc., recommends that none of the buildings surveyed for the current report are individually eligible for listing in the National Register of Historic Places. However, the collective of buildings represents a facility that made notable contributions to the Oak Ridge National Laboratory’s scientific research endeavors from the 1960s to the 1980s, specifically in the field of Health Physics. The buildings and their associated features have also maintained their integrity of setting, materials, design, location, and association. Therefore, Cultural Resource Analysts, Inc., proposes the Dosimetry Applications Research Facility Historic District, which is recommended eligible for listing under Criterion A. The three buildings addressed in the current survey (Buildings 7709, 7710, and 7712) are recommended eligible as contributing resources of the historic district. The district boundary is scribed to incorporate the environs of these three facilities, as well as additional relevant features.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

Closure Report for the Project Shoal Area: Subsurface Corrective Action Unit 447 Shoal,Nevada, Site

The U.S. Department of Energy (DOE) Office of Legacy Management (LM) has prepared this Closure Report for subsurface Corrective Action Unit (CAU) 447 at the Shoal, Nevada, Site, which was formerly called the Project Shoal Area. The Shoal site was the location of an underground nuclear test in 1963 that resulted in residual radionuclide contamination at the detonation depth of 1211 feet (ft) (DOE 2015a). The environmental restoration process and Corrective Action strategy are conducted in accordance with the Federal Facility Agreement and Consent Order (FFACO) (FFACO 1996, as amended) and all applicable Nevada Division of Environmental Protection (NDEP) statues and regulations. Responsibility for the environmental site restoration was transferred from the DOE, National Nuclear Security Administration, Nevada Field Office, to LM on October 1, 2006. The Shoal site is south of U.S. Highway 50, approximately 30 miles southeast of Fallon, in Churchill County, Nevada (Figure 1). The site was selected for underground nuclear testing in 1961, as part of the Vela Uniform Program. Vela was a research and development program directed toward locating, detecting, and identifying underground and high-altitude nuclear detonations. The Vela Uniform program was specific to underground detonations (AEC 1964). The objective of Project Shoal was to detonate a nuclear device underground in an active seismic area to improve the United States’ ability to detect, identify, and locate underground nuclear detonations. The underground nuclear test at Shoal was a joint effort between the U.S. Department of Defense (DOD) and the U.S. Atomic Energy Commission (AEC), which was the predecessor agency to DOE. Figure 1 is a map showing the site location.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Direct Air Capture Using Novel Structured Adsorbents (DE-FE0031959 Final Technical Report)

The objective of this project was to advance direct air capture (DAC) technology through a novel combination of a vacuum-temperature swing CO 2 adsorption process and structured adsorbent beds (SABs). The technical approach was to construct and operate an Integrated DAC System (IDS) at a test facility in Orange County, California. A 30 kilogram per day (kg/day) integrated field test unit was deployed into the field for testing, producing a concentrated CO 2 stream of at least 95% purity. A novel combination of DAC process and hardware with a transformational structured adsorbent laminate filter was fielded and tested at this site. The field testing also captured operational data on the novel process and material combination under real conditions. Data from this were used to advise techno-economic and life cycle analyses (TEA/LCA) of the technology. Despite the early development status and IDS aiming at field validation at TRL 5 rather than commercial scale operations, these analyses give valuable indications of this new technology route’s potential for cost reductions in DAC-based carbon dioxide removal. Climeworks and Svante are committed to further development of the technology route, including the realization of existing further cost reduction potential.

54 ENVIRONMENTAL SCIENCES↗