Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Contamination”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,405 records · Page 78

Operational strategies for contamination control of composite materials

Composite materials, used on many instruments, are a potential contamination source for sensitive sensors, especially for sensors or detectors cooled below -80 C. It is a well known fact that composite materials absorb water during fabrication, integration, test, and launch activities and desorb this water under vacuum conditions. Water absorption can be divided into two types: shallow water and deep water. Shallow water is generally about 500 A thick on a clean material surface and is easily desorbed under vacuum conditions. Deep water is a function of the material and is absorbed into the bulk of the material. Deep water can outgas for weeks, months, or years, depending on the vent path, the amount of absorbed water, and the temperature of the material. Several operational strategies have been successfully employed on the Wide Field Planetary Camera. The operational strategies include ultradry gaseous nitrogen purge, dew point of less than -80 C, and vacuum bake-out with verification of outgassing rates. The nitrogen purge is instituted during the fabrication phase and is continued through launch activities. Great care is taken to avoid extended periods of time that the material is exposed to the ambient environment (50 percent relative humidity). On-orbit operational strategies include heat-up and cool-down scenarios which allow the deep water to be sufficiently outgassed before cooling the sensors or detectors.

Hansen, Patricia A.↗

Reclamation with Recovery of Radionuclides and Toxic Metals from Contaminated Materials, Soils, and Wastes

A process has been developed at Brookhaven National Laboratory (BNL) for the removal of metals and radionuclides from contaminated materials, soils, and waste sites. In this process, citric acid, a naturally occurring organic complexing agent, is used to extract metals such as Ba, Cd, Cr, Ni, Zn, and radionuclides Co, Sr, Th, and U from solid wastes by formation of water soluble, metal-citrate complexes. Citric acid forms different types of complexes with the transition metals and actinides, and may involve formation of a bidentate, tridentate, binuclear, or polynuclear complex species. The extract containing radionuclide/metal complex is then subjected to microbiological degradation followed by photochemical degradation under aerobic conditions. Several metal citrate complexes are biodegraded, and the metals are recovered in a concentrated form with the bacterial biomass. Uranium forms binuclear complex with citric acid and is not biodegraded. The supernatant containing uranium citrate complex is separated and upon exposure to light, undergoes rapid degradation resulting in the formation of an insoluble, stable polymeric form of uranium. Uranium is recovered as a precipitate (polyuranate) in a concentrated form for recycling or for appropriate disposal. This treatment process, unlike others which use caustic reagents, does not create additional hazardous wastes for disposal and causes little damage to soil which can then be returned to normal use.

Francis, A. J.↗

Heterogeneous photocatalytic oxidation of atmospheric trace contaminants

The progress report on heterogeneous photocatalytic oxidation of atmospheric trace contaminants covering the period from 1 May - 31 Oct. 1992 is presented. The two topics discussed are photoreactor monolith fundamental studies and monolith reactor operation: batch recirculation system. Concentration profiles are shown.

Ollis, David F.↗

Optical characterization of LDEF contaminant film

Dark brown molecular film deposits were found at numerous locations on the Long Duration Exposure Facility (LDEF) and have been documented in great detail by several investigators. The exact deposition mechanism for these deposits is as yet unknown, although direct and scattered atomic oxygen, and solar radiation interacting with materials outgassing products have all been implicated in the formation process. Specimens of the brown molecular film were taken from below the flange of the experimental tray located at position D10 on the LDEF. The tray was one of two, comprising the same experiment, the other being located on the wake facing side of the LDEF satellite at position B4. Having access to both trays, we were able to directly compare the effect that orientation with respect to the atomic oxygen flux vector had on the formation of the brown molecular film deposits. The film is thickest on surfaces facing toward the exterior, i.e. the tray corner, as can be seen by comparing the lee and wake aspects of the rivets. The patterns appear to be aligned not with the velocity vector but with the corner of the tray suggesting that flux to the surface is due to scattered atomic oxygen rather than direct ram impingement. The role of scattered flux is further supported by more faint plume patterns on the sides of the tray. The angle of these plumes is strongly aligned with the ram direction but the outline of the deposit implies that incident atoms are scattered by collisions with the edges of the opening resulting in a directed, but diffuse, flux of atomic oxygen to the surface. Spectral reflectance measurements in the 2 to 10 micron (4000 to 1000 wavenumbers) spectral range are presented for the film in the 'as deposited' condition and for the free standing film. The material was analyzed by FTIR (Fourier Transform Infrared) microspectroscopy using gold as the reference standard. The 'as deposited' specimen was on an aluminum rivet taken from beneath the tray flange while the free film was obtained by chipping some of the material from the rivet. The transmission spectrum over the 2 to 10 micron range for the free film is presented. This spectrum appears to be essentially the same as that presented by Crutcher et.al. for films formed at vent sites which faced into the ram direction and suggested to originate from urethanes and silicones used on the LDEF. Banks et. al. state that silicones, when exposed to atomic oxygen, release polymeric scission fragments which deposit on surfaces and form a glassy, dark contaminant layer upon further atomic oxygen exposure and solar irradiation.

Blakkolb, Brian K.↗

Contamination design of a Scientific Instrument Protective Enclosure for the Hubble Space Telescope Servicing Mission

A Scientific Instrument Protective Enclosure (SIPE) was designed to accommodate second generation science instruments (SIs) for the Hubble Space Telescope (HST) First Servicing Mission (FSM). One of the main design drivers for the SIPE is to provide a protective environment for the SIs against particulate and molecular contaminants that pose a viable threat to the SI performance. The focus of this paper will detail the methodology incorporated in the design of the SIPE to provide a controlled environment for SI protection at the launch site, during pre-launch/launch activities, and during on-orbit operations in the Shuttle bay.

Hedgeland, Randy J.↗

The bromine content of micrometeorites - Arguments for stratospheric contamination

Bromine-salt nanocrystals are associated with a porous chondritic micrometeorite (W7029E5) that was collected in the lower stratosphere. These salt nanocrystals occur together with volcanic Na and K salt nanocrystals embedded in sulfuric acid droplets that were originally adhered to the particle. These materials were concentrated during hexane rinsing as part of routine curation procedures at the NASA Johnson Space Center Cosmic Dust Curatorial Facility. This observation is fortuitous to the extent that the concentration of nanocrystals and sulfuric acid is an experimental artifact of curation. If bromine is a stratospheric contaminant due to surface adsorption, there should be a positive linear relationship between the mass-normalized residence time and bromine content of individual micrometeorites. I show that the predicted correlation exists using a new model to calculate the stratospheric residence time of individual nonspherical micrometeorites in the slow-settling Wilson-Huang regime of the stratosphere.

Rietmeijer, Frans J. M.↗

Evaluation of capillary electrophoresis for in-flight ionic contaminant monitoring of SSF potable water

Until 1989, ion chromatography (IC) was the baseline technology selected for the Specific Ion Analyzer, an in-flight inorganic water quality monitor being designed for Space Station Freedom. Recent developments in capillary electrophoresis (CE) may offer significant savings of consumables, power consumption, and weight/volume allocation, relative to IC technology. A thorough evaluation of CE's analytical capability, however, is necessary before one of the two techniques is chosen. Unfortunately, analytical methods currently available for inorganic CE are unproven for NASA's target list of anions and cations. Thus, CE electrolyte chemistry and methods to measure the target contaminants must be first identified and optimized. This paper reports the status of a study to evaluate CE's capability with regard to inorganic and carboxylate anions, alkali and alkaline earth cations, and transition metal cations. Preliminary results indicate that CE has an impressive selectivity and trace sensitivity, although considerable methods development remains to be performed.

Mudgett, Paul D.↗

Contamination control and plume assessment of low-energy thrusters

A method for evaluating the effects of gases originating from plumes or other direct sources impinging on sensitive surfaces located within their field of view is presented. The method is applied to an Xe ion plasma generator with a thrust of a few mN located near a cryogenic surface. The method is based on experimentally derived plume descriptions of emitted low-pressure vented gases and test results of plume distributions from a similar ion engine. It is concluded that the plume of the Xe neutrals represented by a cosine squared function of the angle is a possible contamination source for certain surfaces of the spacecraft.

Scialdone, John J.↗

Balloon Catheter Prevents Contamination

Balloon catheter similar to that used in such medical procedures as angioplasty and heart surgery protects small orifices against contamination and blockage by chips generated in machining operations. Includes small, inflatable balloon at end of thin, flexible tube. Contains additional features adapting it to anticontamination service: balloon larger to fit wider channel it must block; made of polyurethane (rather than latex), which does not fragment if bursts; material made thicker to resist abrasion better; and kink-resistant axial wire helps catheter negotiate tight bends.

Higginson, Gregory A.↗

Wave generation by contaminant ions

Investigations dealing with the generation of waves by contaminant ions are reported. The studies included the properties of the velocity distribution function of such ions. It was found that it takes about one ion-cyclotron period for the distribution function to transform from a beam to a ring distribution. A linear instability analysis was performed to examine the possibility of wave excitation by an ion beam streaming perpendicular to the ambient magnetic field in an ionospheric type of plasma. A simulation code was developed to study the nonlinear behavior of the waves excited by beam and ring types of ion distributions. The code treats both electrons and ions as particles kinetically to also factor in the possible involvement of lower-hybrid waves.

Singh, N.↗

Trace element content of chondritic cosmic dust: Volatile enrichments, thermal alterations, and the possibility of contamination

Trace element abundances in 51 chondritic Interplanetary Dust Particles (IDP's) were measured by Synchrotron X-Ray Fluorescence (SXRF). The data allow us to determine an average composition of chondritic IDP's and to examine the questions of volatile loss during the heating pulse experienced on atmospheric entry and possible element addition due to contamination during atmospheric entry, stratospheric residence, and curation.

Flynn, G. J.↗

Possible dust contamination of the early solar system

Measurements carried out over more than twenty years indicate a deficiency of neutrinos emitted from the deep interior of the Sun in conjunction with the neutrino flux expected from canonical solar models. The early measurements were sensitive only to high-energy neutrinos emitted from B-8 on a minor branch of the energy-producing nuclear reactions in the solar interior. Thus these measurements were not widely considered to be a definitive test of solar physics. However the more recent measurements, which are sensitive to lower energy neutrinos, produced primarily by the p-p reaction on the main energy-producing branch of the solar nuclear reactions, pose a far more significant mystery in physics. One possibility is that the Sun's interior opacity is lower than expected due to a paucity of elements. This paper discusses that the Sun formed from material less abundant in heavy elements than usually believed, and the subsequent contamination due to the settling of surrounding dust brought the abundance of heavy elements - in the protoplanetary nebula, and in the Sun's convective envelope - up to the currently observed value.

Levy, E. H.↗

Contamination control and plume assessment of low-energy thrusters

Potential contamination of a spacecraft cryogenic surface by a xenon (Xe) ion generator was evaluated. The analysis involves the description of the plume exhausted from the generator with its relative component fluxes on the spacecraft surfaces, and verification of the conditions for condensation, adsorption, and sputtering at those locations. The data describing the plume fluxes and their effects on surfaces were obtained from two sources: the tests carried out with the Xe generator in a small vacuum chamber to indicate deposits and sputter on monitor slides; and the extensive tests with a mercury (Hg) ion thruster in a large vacuum chamber. The Hg thruster tests provided data on the neutrals, on low-energy ion fluxes, on high-energy ion fluxes, and on sputtered materials at several locations within the plume.

Scialdone, John J.↗

Modeling of LDEF contamination environment

The Long Duration Exposure Facility (LDEF) satellite was unique in many ways. It was a large structure that was in space for an extended period of time and was stable in orientation relative to the velocity vector. There are obvious and well documented effects of contamination and space environment effects on the LDEF satellite. In order to examine the interaction of LDEF with its environment and the resulting effect on the satellite, the Integrated Spacecraft Environments Model (ISEM) was used to model the LDEF-induced neutral environment at several different times and altitudes during the mission.

Carruth, M. Ralph, Jr.↗

Heterogeneous photocatalytic oxidation of atmospheric trace contaminants

Research was conducted on: (1) design and construction of a continuous flow photoreactor to study oxidation of trace atmospheric contaminants; (2) kinetics of acetone oxidation including adsorption equilibrium, variation of oxidatiin rate with acetone concentration and water, and variation of rate and apparent quantum yield with light intensity, and (3) kinetics of butanol oxidation, including rate variations; and (4) kinetics of catalyst deactivation including deactivation rate, influence of dark conditions, and photocatalytic regeneration in alcohol-free air.

Ollis, David F.↗

Analysis of trace halocarbon contaminants in ultra high purity helium

This study describes the analysis of ultra high purity helium. Purification studies were conducted and containment removal was effected by the utilization of solid adsorbent purge-trap systems at cryogenic temperatures. Volatile organic compounds in ultra high purity helium were adsorbed on a solid adsorbent-cryogenic trap, and thermally desorbed trace halocarbon and other contaminants were analyzed by combined gas chromatography-mass spectrometry.

Fewell, Larry L.↗

Device For Sampling Surface Contamination

Specially designed cotton swab suitable for use in clean room. Contamination-sampling device improved version of basic cotton-tipped wooden applicator, designed for extreme cleanliness and to enhance utility for sampling according to exacting specifications. Device does not shed cotton and wood fibers.

Delgado, Felix A.↗