Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Condition Monitoring”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,405 records · Page 78

Using onset times from frequent seismic surveys to understand fluid flow at the Peace River Field, Canada

With our limited knowledge of the relationship between changes in the state of an aquifer or reservoir and the corresponding changes in the elastic moduli, that is the rock physics model, hampers the effective use of time-lapse seismic observations for estimating flow properties within the Earth. A central problem is the complicated dependence of the magnitude of time-lapse changes on the saturation, pressure, and temperature changes within an aquifer or reservoir. We describe an inversion methodology for reservoir characterization that uses onset times, the calendar time of the change in seismic attributes, rather than the magnitude of the changes. We find that onset times are much less sensitive than magnitudes to the rock physics model used to relate time-lapse observations to changes in saturation, temperature and fluid pressure. We apply the inversion scheme to observations from daily monitoring of enhanced oil recovery at the Peace River field in Canada. An array of 1492 buried hydrophones record seismic signals from 49 buried sources. Time-shifts for elastic waves traversing the reservoir are extracted from the daily time-lapse cubes. In our analysis 175 images of time-shifts are transformed into a single map of onset times, leading to a substantial reduction in the volume of data. These observations are used in conjunction with bottom hole pressure data to infer the initial conditions prior to the injection, and to update the reservoir permeability model. The combination of a global and local inversion scheme produces a collection of reservoir models that are best described by three clusters. The updated model leads to a nearly 70 percent reduction in seismic data misfit. The final set of solutions successfully predict the observed normalized pressure history during the soak and flow-back into the wells between 82 and 175 days into the cyclic steaming operation.

58 GEOSCIENCES↗

An adaptable technique for comparative image assessment: Application to crosswell electromagnetic survey design for fluid monitoring

Reservoir integrity stewardship accompanying carbon capture and sequestration considers fluid extraction and reinjection as a risk-mitigating method against overpressuring that could lead to caprock damage and ensuing [Formula: see text] leakage. Crosswell electromagnetics offers a technically viable monitoring method with the spatial volume coverage necessary for reservoir-encompassing pressure management. However, a certain logistic dilemma for deep gas sequestration into saline and thus electrically conductive aquifers is that crosswell magnetic-field measurements underperform in the imaging of more resistive plume bodies, further exacerbated when vertical arrays intersect, as opposed to surround, plumes. Furthermore, comparative synthetic-data plume imaging of such scenarios rates the information content of magnetic-field versus electric-field 3D crosswell layouts for reservoir and infrastructure conditions of a representative pilot site in a coastal area in Florida. The image quality of the resulting plume replications can be ranked numerically through a newly proposed semblance qualifier, appraising the model goodness of fit to a given reference. In contrast to common least-squares measures for goodness of fit, the semblance formulation uses classifying logistic function types, thus enabling a better distinction of predefined anomaly features.

58 GEOSCIENCES↗

2025 Intern Poster

The Hot Fuel Examination Facility (HFEF) at the Materials and Fuels Complex (MFC) houses the largest U.S. inert atmosphere hot cell for nuclear material research. Key features include the precision gamma scanning (PGS), Fuel Accident Condition Simulator (FACS), Neutron Radiography Reactor (NRAD), and the focus of this project, the Metallograph Loading Cell (MET Cell). The MET Cell performs tests on spent nuclear fuel, such as microhardness testing, microscopy, and neutron radiography. However, the MET Cell’s existing pressure and lighting control systems are outdated and inefficient, with inadequate documentation for system changes over time. This project aims to design a new automated control system for the MET Cell, ensuring longevity (minimum ten years), ease of troubleshooting/repair, and integration into the building monitoring system. The design process addressed challenges such as space restrictions, varied voltages within enclosures, sourcing new components, and security limitations. Compliance with NFPA 70, UL508A, MFC Physical Security, and INL Engineering standards was essential. The project involves repurposing an existing PLC to manage lighting and pressure control using digital and analog signals, simplifying wiring, and ensuring thorough documentation for future reference.

42 - ENGINEERING↗

Model 9975 O Ring Fixture LongTerm Leak Performance (FY2021 Status Report)

Leak testing experiments to monitor the aging performance of Viton® GLT and GLT-S O-rings used in the model 9975 shipping package has been ongoing since 2004 at Savannah River National Laboratory. Seventy tests using mock-up 9975 primary containment vessels (PCVs) with GLT O-rings were assembled and heated to temperatures ranging from 200 to 450 °F. Due to material substitution, fourteen tests with GLT-S O-rings were initiated in 2008 and heated to temperatures ranging from 200 to 400 °F. The conditioning temperatures are elevated compared to the calculated maximum O-ring temperature in a 9975 package in storage, 158 °F, to accelerate aging and enable observations of O-ring failures in a reasonable time frame. The fixtures are leak tested periodically and all GLT O-ring fixtures aging at 350 °F or above have failed to maintain a leak-tight seal. Eight GLT O-ring fixtures aging at 300 °F have failed after 2.8 to 5.7 years at temperature while the remaining fixtures at 300 °F were retired from testing following more than five years without failure. There has been one GLT O-ring fixture which failed after 13.4 years aging at 200 °F. However, 19 other GLT O-rings aging at 200 °F have remained leak-tight for over 14 years and remain in test. No failures have yet been observed in GLT O-ring fixtures aging at 270 °F for 9.5 years. All GLT-S O-ring fixtures aging at 300 °F or above have failed their leak test. No failures have yet been observed in GLT-S O-ring fixtures aging at 200 and 250 °F for 11.5 years. Data from the O-ring fixtures are generally consistent with results from compression stress-relaxation testing, and provide confidence in the predictive models based on those results. However, uncertainty exists in extrapolating these elevated temperature results to the lower temperatures of interest for normal storage in K-Area Complex (KAC). Oxygen consumption testing, which includes results from temperatures near KAC normal storage temperatures, is ongoing to provide further confidence and corroborate these extrapolations. The collective data from these test efforts suggest the minimum O-ring service life at KAC normal storage conditions should be at least 34 years for GLT and GLT-S O-rings. Measurement of compression set in O-rings removed from failed fixtures, compared to that from KAC surveillance O-rings, indicate significant margin remains for O-rings still in service in 9975 packages in KAC. Aging and periodic leak testing will continue for the remaining 26 mock-up PCV fixtures.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Model 9975 O-Ring Fixture Long-Term Leak Performance (FY2022 Status Report)

Leak testing experiments to monitor the aging performance of Viton® GLT and GLT-S O-rings used in the model 9975 shipping package has been ongoing since 2004 at Savannah River National Laboratory. Seventy tests using mock-up 9975 primary containment vessels (PCVs) with GLT O-rings were assembled and heated to temperatures ranging from 200 to 450 °F. Due to material substitution, fourteen tests with GLT-S O-rings were initiated in 2008 and heated to temperatures ranging from 200 to 400 °F. The conditioning temperatures are elevated compared to the calculated maximum O-ring temperature in a 9975 package in storage, 158 °F, to accelerate aging and enable observations of O-ring failures in a reasonable time frame. The fixtures are leak tested periodically and all GLT O-ring fixtures aging at 350 °F or above have failed to maintain a leak-tight seal. Eight GLT O-ring fixtures aging at 300 °F have failed after 2.8 to 5.7 years at temperature while the remaining fixtures at 300 °F were retired from testing following more than five years without failure. There has been one GLT O-ring fixture which failed after 13.4 years aging at 200 °F. However, 20 other GLT O-rings aging at 200 °F have remained leak-tight for over 14 years and remain in test. No failures have yet been observed in GLT O-ring fixtures aging at 270 °F for 10.4 years. All GLT-S O-ring fixtures aging at 300 °F or above have failed their leak test. No failures have yet been observed in GLT-S O-ring fixtures aging at 250 °F for 12.5 years. This year, one GLT-S O-ring fixture failed after 12.4 years aging at 200 °F. Data from the O-ring fixtures are generally consistent with results from compression stress-relaxation testing, and provide confidence in the predictive models based on those results. However, uncertainty exists in extrapolating these elevated temperature results to the lower temperatures of interest for normal storage in K-Area Complex (KAC). Oxygen consumption testing, which includes results from temperatures near KAC normal storage temperatures, is ongoing to provide further confidence and corroborate these extrapolations. The collective data from these test efforts suggest the minimum O-ring service life at KAC normal storage conditions should be at least 34 years for GLT and GLT-S O-rings. Measurement of compression set in O-rings removed from failed fixtures, compared to that from KAC surveillance O-rings, indicate significant margin remains for O-rings still in service in 9975 packages in KAC. Aging and periodic leak testing will continue for the remaining 25 mock-up PCV fixtures.

36 MATERIALS SCIENCE↗

FY2023 Status Report: Model 9975 O-Ring Fixture Long-Term Leak Performance

Leak testing experiments to monitor the aging performance of Viton ® GLT and GLT-S O-rings used in the model 9975 shipping package has been ongoing since 2004 at Savannah River National Laboratory. Seventy tests using mock-up 9975 primary containment vessels (PCVs) with GLT O-rings were assembled and heated to temperatures ranging from 200 to 450 °F. Due to material substitution, fourteen tests with GLT-S O-rings were initiated in 2008 and heated to temperatures ranging from 200 to 400 °F. The conditioning temperatures are elevated compared to the calculated maximum O-ring temperature in a 9975 package in storage, 158 °F, to accelerate aging and enable observations of O-ring failures in a reasonable time frame.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Model 9975 O Ring Fixture Long-Term Leak Performance (FY2024 Status Report)

Leak testing experiments to monitor the aging performance of Viton ® GLT and GLT-S O-rings used in the model 9975 shipping package have been ongoing since 2004 at Savannah River National Laboratory. Seventy tests using mock-up 9975 primary containment vessels (PCVs) with GLT O-rings were assembled and heated to temperatures ranging from 200 to 450 °F. Due to material substitution, fourteen tests with GLT-S O-rings were initiated in 2008 and heated to temperatures ranging from 200 to 400 °F. The conditioning temperatures are elevated compared to the calculated maximum O-ring temperature in a 9975 package in storage, 158 °F, to accelerate aging and enable observations of O-ring failures in a reasonable time frame. The mock-up PCV fixtures are leak tested periodically, and all GLT O-ring fixtures aging at 350 °F or above have failed to maintain a leak-tight seal. Eight GLT O-ring fixtures aging at 300 °F have failed after 2.8 to 5.7 years at temperature while the remaining fixtures at 300 °F were retired from testing following more than five years of aging without failure. Two of these retired fixtures were returned to testing and heated to 350 °F to evaluate the impact of additional heating at higher temperature for aged O-rings. Fixture #20 failed after 3 months of testing while fixture #18 remained leak tight. These O-rings demonstrated that aged and in-service O-rings can continue to be used, even at higher temperatures, after being in storage, and their leak performance are consistent with other samples at 350 °F.

42 ENGINEERING↗

FY2025 Status Report: Model 9975 O Ring Fixture Long-Term Leak Performance

Leak testing experiments to monitor the aging performance of Viton® GLT and GLT-S O-rings used in the model 9975 shipping package have been ongoing since 2004 at Savannah River National Laboratory. Seventy tests using mock-up 9975 primary containment vessels (PCVs) with GLT O-rings were assembled and heated to temperatures ranging from 200 to 450 °F. Due to material substitution, fourteen tests with GLT-S O-rings were initiated in 2008 and heated to temperatures ranging from 200 to 400 °F. The conditioning temperatures are elevated compared to the calculated maximum O-ring temperature in a 9975 package in storage, 158 °F, to accelerate aging and enable observations of O-ring failures in a reasonable time frame. The mock-up PCV fixtures are leak tested periodically, and all GLT O-ring fixtures aged at 350 °F or above have failed to maintain a leak-tight seal. Eight GLT O-ring fixtures aged at 300 °F have failed after 2.8 to 5.7 years at temperature while the remaining fixtures at 300 °F were retired from testing following more than five years of aging without failure. Two of these retired fixtures were returned to testing and heated to 350 °F to evaluate the impact of additional heating at higher temperature for aged O-rings. Fixture #20 failed after 3 months while fixture #18 failed after 9 months at 350 °F. These O-rings demonstrated that aged and in-service O-rings can continue to be used, even at higher temperatures, after being in storage, and their leak performance are consistent with other samples at 350 °F. There has been one GLT O-ring fixture which failed after 13.4 years of aging at 200 °F. However, 20 other GLT O-rings aging at 200 °F have remained leak-tight for over 16.9 years and remain in test. There are two GLT O-ring fixtures at 270 °F; one fixture has failed after 12.9 years while the other fixture remains in test after 12.5 years. All GLT-S O-ring fixtures aged at 300 °F or above have failed their leak test. No failures have yet been observed in GLT-S O-ring fixtures aging at 250 °F for 14.9 years, while one GLT-S O-ring fixture failed after 12.4 years at 200 °F. The leak testing data to date suggest the GLT and GLT-S O-rings aging in the K-Area Complex (KAC) storage at temperatures of 158 °F might maintain a leak-tight seal for up to 59 years. Data from the O-ring fixtures are generally consistent with results from compression stress-relaxation testing and provide confidence in the predictive models based on those results. However, uncertainty exists in extrapolating these elevated temperature results to the lower temperatures of interest for normal storage in KAC. The collective data from these test efforts suggest the minimum O-ring service life at KAC normal storage conditions should be at least 34 years for GLT and GLT-S O-rings. Measurement of compression set in O-rings removed from failed fixtures, compared to that from KAC surveillance O-rings, indicate significant margin remains for O-rings still in service in 9975 packages in KAC. Aging and periodic leak testing will continue for the remaining 24 mock-up PCV fixtures.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Visualizing plant cell wall changes proves the superiority of hydrochloric acid over sulfuric acid catalyzed γ-valerolactone pretreatment

Thermochemical pretreatment is one of the key steps to process lignocellulosic biomass for production of biofuels and biomaterials. γ-valerolactone (GVL) has been used as a green and renewable solvent to efficiently dissolve lignin under acidic conditions and enhance subsequent enzyme digestibility. Further improvement is still required to lower the pretreatment temperature in order to reduce sugar degradation and irreversible lignin condensation, as well as the capital cost. In this study, we compared the use of HCl and H 2 SO 4 as catalysts during GVL pretreatment, and found the performance of GVL-HCl at 100 °C was comparable to that of GVL-H 2 SO 4 at 120 °C in terms of xylan and lignin removal and enzyme digestibility. We further monitored the lignin removal and cellulose accessibility in the cell walls at different pretreatment time points by imaging the changes in lignin auto-fluorescence and in CtCBM3-GFP binding with confocal laser scanning microscopy (CLSM), respectively. We found GVL-HCl pretreatment at a relative low temperature (100 °C) could rapidly remove lignin in the compound middle lamella and cell corner areas, which concurred with the increase of CtCBM3-GFP binding in these areas. Real-time imaging of cell wall degradation by cellulases further revealed that the secondary cell walls could be digested from both cell lumen and CML sides, and eventually fully deconstructed within 24 h. Furthermore, our results provide new insight into the effects of chloride anions on plant cell wall structure during GVL pretreatment, and offer potential routes to further optimize and enhance the efficiency of GVL-based pretreatment.

09 BIOMASS FUELS↗

Identification of beneficial and detrimental bacteria impacting sorghum responses to drought using multi-scale and multi-system microbiome comparisons

Abstract Drought is a major abiotic stress limiting agricultural productivity. Previous field-level experiments have demonstrated that drought decreases microbiome diversity in the root and rhizosphere. How these changes ultimately affect plant health remains elusive. Toward this end, we combined reductionist, transitional and ecological approaches, applied to the staple cereal crop sorghum to identify key root-associated microbes that robustly affect drought-stressed plant phenotypes. Fifty-three Arabidopsis-associated bacteria were applied to sorghum seeds and their effect on root growth was monitored. Two Arthrobacter strains caused root growth inhibition (RGI) in Arabidopsis and sorghum. In the context of synthetic communities, Variovorax strains were able to protect plants from Arthrobacter-caused RGI. As a transitional system, high-throughput phenotyping was used to test the synthetic communities. During drought stress, plants colonized by Arthrobacter had reduced growth and leaf water content. Plants colonized by both Arthrobacter and Variovorax performed as well or better than control plants. In parallel, we performed a field trial wherein sorghum was evaluated across drought conditions. By incorporating data on soil properties into the microbiome analysis, we accounted for experimental noise with a novel method and were able to observe the negative correlation between the abundance of Arthrobacter and plant growth. Having validated this approach, we cross-referenced datasets from the high-throughput phenotyping and field experiments and report a list of bacteria with high confidence that positively associated with plant growth under drought stress. In conclusion, a three-tiered experimental system successfully spanned the lab-to-field gap and identified beneficial and deleterious bacterial strains for sorghum under drought.

59 BASIC BIOLOGICAL SCIENCES↗

An ML-based terrestrial data fusion and augmentation framework to enable advanced understanding of the terrestrial carbon and water interactions

Soil moisture is essential to the terrestrial carbon and water cycles and land–atmosphere interactions. There are various types of soil moisture data, and each type has the distinct spatiotemporal strengths and limitations, depending on the diverse applications and retrieval methodologies of different data types (Li et al., in review; The PNNL-82151 FY23 Report). However, the limitations of different soil moisture data in terms of accuracy and spatiotemporal coverage hinder our ability to further understand the soil moisture dynamics across scales. To have a gap free soil moisture data product with a fine spatiotemporal coverage and vertical profiles, we train extreme gradient boosting (XGBoost) models by using (1) in-situ soil moisture measurements from the International Soil Moisture Network (ISMN), (2) soil moisture from the ECMWF reanalysis (ERA) at the 9 km and sub-daily spatiotemporal resolution, (3) the Daymet meteorological fields, and (4) data products that characterize surface conditions, including soil texture, organic content, topography, vegetation type, and rooting depth. We use the trained XGBoost models that have consistent performance across seven soil layers, i.e., 0–5 cm, 5–10 cm, 10–20 cm, 20–40 cm, 40–60 cm, 60–100 cm, and 100–200 cm, and the gridded model predictors to generate a soil moisture data at the 1 km and daily spatiotemporal resolution for the Continental United States (CONUS) from 2001–2020. This dataset can be broadly used for Earth system model benchmark, monitoring extreme weathers, making informed decisions regarding agriculture, water resource management, climate change mitigation, and ecosystem preservation.

58 GEOSCIENCES↗

A spatially regularized detector for emergent/re-emergent disease outbreaks

Early detection of outbreaks caused by emergent pathogens, using epidemiological surveillance data i.e., daily case counts, is difficult. This is because the data tend to be noisy during the early epoch of the outbreak. In contrast, the spread-rate of the disease tends to be well-behaved, as it depends only on the mixing patterns of the population and the characteristics of the pathogen, neither of which behave erratically in space-time. In this report, we explore whether the spread-rate can be used for epidemiological surveillance, conditional on case count data. Estimating the spread-rate from case count data allows us to exploit exogenous information, e.g., incubation period distributions etc., which can considerably smooth out any erratic temporal behavior. Further, epidemiological dynamics are spatially correlated, and if case counts are available for multiple areal units e.g., counties, these correlations could potentially be used to suppress noise in the early epoch data. These exogenous information and structure are not exploited by conventional syndromic surveillance detectors to extract a well-behaved latent variable for monitoring purposes. The technical challenge lies in the estimation of the spread-rate field jointly over a collection of areal units; further, the spread-rate varies over time. We develop a method based on mean-field variational inference to approximately estimate the spread-rate field, using a Gaussian Random Field Model for spatial regularization. The method is tested on the estimation of spread-rate in the thirty-three counties of New Mexico and detect the arrival of the Fall 2020 COVID-19 wave in September 2020. We find that the method is scalable, but underestimates the uncertainty in the estimated spread-rate field. We detect the arrival of the Fall 2020 wave a week ahead of conventional syndromic surveillance algorithms, but our simplistic detection algorithm, based on simple anomaly detection, suffers from a high false positive rate, similar to conventional detectors.

59 BASIC BIOLOGICAL SCIENCES↗

On the formation of swelling and related flaws in laser powder bed fusion

Process monitoring in laser powder bed fusion additive manufacturing can provide insights into stochastic anomalies, melt pool and plume dynamics, and part quality. Swelling, a build anomaly where overbuilt material protrudes through the powder layer after recoating, is readily detectable in post-recoat visible light images of the powder bed. Here, this work identifies several of the underlying mechanisms driving swelling formation by analyzing the influence of processing parameters, laser scan paths, and build plate locations on the presence of swelling detected in situ. Swelling near the edge of the part and swelling in the internal region of the part are shown to correlate with different process conditions. Edge and internal swelling may be driven by different phenomena, with edge swelling predominately occurring on the edge of a part facing the laser module and correlated to clusters of near-surface voids (detected with X-ray computed tomography). A larger spot size, higher laser power, and lower scan velocity also increased the presence of edge swelling. Laser spot size and scan path influenced internal swelling, which occurred preferentially with a larger spot size and in regions with large melt pools, caused by localized heat accumulation due to non-optimal processing parameters or scan path strategies. For coupons processed with a slicer-defined maximum scan vector length, swelling seldom occurred at internal vector-stripe boundaries. These results provide a mechanistic understanding of how swelling can be linked to material flaws, insight into how some instances of swelling can be avoided, and evidence supporting the use of swelling as an in situ indicator for quality assurance and part qualification.

Anomaly↗

Combined Raman and Turbidity Probe for Real-Time Analysis of Variable Turbidity Streams

We know that real-time and in situ process monitoring is a powerful tool that can empower operators of hazardous processes to better understand and control their chemical systems without increased risk to themselves. However, applying monitoring techniques to complex chemical processes can face challenges. An example of this is the application of optical spectroscopy, otherwise capable of providing detailed chemical composition information, to processes exhibiting variable turbidity. Here, details on a novel combined Raman spectroscopy and turbidimetry probe are discussed. Furthermore, the analytical approach to accurately account for both Raman signal and turbidity while quantifying chemical targets is detailed. Through leveraging Raman and turbidity data simultaneously collected from the combined probe within chemometric models, accurate quantification of multiple chemical targets can be achieved under conditions of variable concentrations and turbidity.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Low Count and Background Radionuclides Analysis - 20488

The US Department of Energy (DOE) is often faced with the need to evaluate radionuclides at low concentrations. When site sample data are likely to be close to threshold activity concentrations of interest, then the means by which the radiochemical analysis is performed and reported is critical. This situation can occur when differentiating from zero (presence/absence) for radionuclides that do not occur naturally, close comparison with environmental background for naturally occurring radionuclides, close comparison with a risk- or dose-based threshold concentrations of interest, or even comparisons across studies. There are several analytical issues that are of concern, but the two that appear to cause incorrect decisions to be made most often involve establishing detection limits and subtracting ambient background conditions in the laboratory. These issues are not critical when radionuclide activity concentrations are large relative to thresholds of concern, but they seem to be poorly understood when it matters. When the comparisons are important and are likely to be close to a threshold of interest, then the general contract with the analytical laboratories needs to be changed so that the right or appropriate data are obtained. The concern is that important decisions are made incorrectly more often as greater scrutiny is placed on DoE's radionuclide cleanup or monitoring decisions by the public and other stakeholders. Examples are presented of problems that have been observed for different projects, both within and outside the realm of DOE and NRC remediation and radioactive waste disposal problems, and solutions are offered that should lead to better data from which important decisions need to be made. The first example is from Los Alamos National Laboratory (LANL) and involves radionuclide concentrations in soil and rock beneath LANL's Material Disposal Area (MDA) G. An initial review of the data led to a conclusion that americium and plutonium are a long way present beneath MDA G. A more thorough review of the data that accounted properly for ambient background and the detection limits that had been established led to the opposite conclusion. Another example is from the Nevada National Security Site where tritium results from one of the wells were unexpectedly high. Proper understanding and analysis of ambient background led to the conclusion that the increased concentrations were not so obvious, and that a different contract with the analytical laboratory was needed to provide more appropriate data to support a better determination. Other examples are used from regulatory review of projects in Nevada, where background levels and secular equilibrium for naturally occurring radionuclides are not established correctly because of analytical issues. The same basic issues have also been found to create difficulties analyzing historical data from the West Valley Demonstration Project. There is evidence in the data that the apparent lack of secular equilibrium where it is expected to exist is related to ambient background subtraction or other analytical issues. A final example is presented for analysis of Tc-99 in samples of depleted uranium. In this case, two different studies that were performed only three months apart provide quite different results. The US Environmental Protection Agency (EPA) established the data quality objectives (DQO) process in the mid-1980's to establish decision performance criteria for data collection. EPA guidance (EPA G-4, for example) clearly distinguishes between DQOs and measurement performance objectives (MQOs) that should be addressed for laboratory analysis of samples. The language of DQOs and MQOs has become confused over time it seems, and the subsequent effects seem to include a lack of attention to decision performance and a routine approach to measurement quality. In order to better address radionuclide sample analysis when the concentrations are close to thresholds of concern, which might be zero for some radionuclides, background for others, and risk-based thresholds for yet others, it is important that routine laboratory analysis methods are adjusted, and that the project team and the laboratory work closely together to ensure that the data meets the MQO requirements of laboratory analysis and reporting of results, and that the MQOs effectively support project-specific DQOs. This basic approach will be applied in Los Alamos in the coming year to the collection of moisture data from underneath MDA T that will be analyzed for americium and neptunium isotopes. Proper understanding of the radiochemistry methods and reporting, and of appropriate statistical methods is critical to the success of such projects, ensuring that the right decisions are made. (authors)

07 ISOTOPE AND RADIATION SOURCES↗

Photovoltaic inverter-based quantification of snow conditions and power loss

Snow is a significant challenge for photovoltaic (PV) systems at northern latitudes, where the pace of deployment is rapid but snow-related power losses can exceed 30% of annual production. Accurate snow-related power loss estimation methods for utility-scale sites can support snow mitigation strategies, inform resource planning and validate predictive snow-loss models. This study builds on our previous work on inverter-based detection of snow, and its implications for utility-scale power production, by validating the accuracy of our snow-loss method across different PV sites and system designs and highlighting its value in bringing greater visibility to PV plant operations in winter. Our estimation method is both novel and scalable, requiring only standard monitoring data to correlate snow-related losses with meteorological data. As demonstrated here, our validation method involved three main steps: 1) estimation of performance losses for multiple systems by comparing measured inverter data to modeled data; 2) application of a detection framework to identify which performance losses are snow-related; and 3) comparison of snow-related losses among three utility-scale sites differing in tilt angle. Results show that utility-scale systems at higher tilt angles consistently shed snow more quickly/completely than their lower-tilt counterparts. Further, monthly and seasonal snow losses are inversely and non-linearly correlated with tilt angle when normalized for cumulative snowfall. These results are consistent with the findings of previous studies and support the broad applicability of this method to fixed-tilt utility-scale PV systems around the world that routinely experience snow-related performance losses.

Cooper, Emma C. (ORCID:0000000190554098)↗

Performance Assessment for the Environmental Restoration Disposal Facility (Annual Status Report FY 2021)

DOE O 435.1 and DOE M 435.1-1 require that a determination of continued adequacy of the performance assessment (PA) (CP-60089), composite analysis (CA), and disposal authorization statement (DAS) be made on an annual basis, and that the determination must consider the results of data collection and analysis from research, field studies, and monitoring as well as the need to update any Radioactive Waste Management Basis (RWMB) documents. Beginning in 1996, the Environmental Disposal Facility (ERDF) started accepting low-level radioactive, hazardous, and mixed wastes that were generated during cleanup activities at the Hanford Site. ERDF is composed of a series of cells or disposal areas and can accommodate future design expansions as needed. Currently, there are eight cells and two supercells in ERDF. Each supercell is the equivalent of two cells. During this reporting period (fiscal year 2021, extending from October 1, 2020, through September 30, 2021), approximately 9.14E+04 metric tons (1.01E+05 U.S. tons) of waste was disposed at ERDF. From ERDF inception through September 30, 2021, approximately 16.9 million metric tons (18.9 U.S. tons) of waste has been disposed of at ERDF, which equates to consumption of approximately 88.7% of the currently constructed disposal volume. According to the design of ERDF, the facility has the ability to be expanded as needed. As a condition of the DAS, disposal operation within ERDF must be in accordance with the waste acceptance criteria (ERDF-00011) that provide specific radionuclide disposal limits, waste form restrictions, and descriptions of acceptable waste packages in compliance with the requirements of DOE M 435-1.1. The ERDF waste acceptance criteria stipulate that waste destined for disposal at ERDF be controlled based on source, physical form, and contaminant concentration and activity levels. There have been no changes to the physical configuration of ERDF or to the waste forms (source, physical form, etc.). No new unreviewed disposal question screenings or evaluations have been generated in this reporting period. Therefore, there are no noted impacts to the PA, CA, DAS, or RWMB resulting from the evaluations and screenings. Sum-of-fractions analysis shows that the disposed inventory meets both the concentration and inventory threshold requirements. A sum-of-fractions value is computed for ERDF sensitive radionuclides contributing to the all pathways and the air pathway inventory limits. Computed values were 7.63E-03 and 1.49E-03, respectively. The disposed waste inventory remained well under the PA imposed limits, as shown in Table 4 and Table 5 in the main text of this report. Required monitoring was satisfactorily completed during the fiscal year reporting period. Compliance with performance objectives were met as each of the reported values were well below the established limit. Overall, there are no substantive changes to primary PA assumptions or changes to the PA analysis conclusion; therefore, compliance with DOE O 435.1 and the DAS is maintained.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Performance Assessment for the Environmental Restoration Disposal Facility (Annual Status Report FY 2022)

DOE O 435.1 and DOE M 435.1-1 require that a determination of continued adequacy of the performance assessment (PA) (CP-60089), composite analysis (CA), and disposal authorization statement (DAS) be made on an annual basis, and that the determination must consider the results of data collection and analysis from research, field studies, and monitoring as well as the need to update any Radioactive Waste Management Basis (RWMB) documents. Beginning in 1996, the Environmental Restoration Disposal Facility (ERDF) started accepting low-level radioactive, hazardous, and mixed wastes that were generated during cleanup activities at the Hanford Site. ERDF is composed of a series of cells or disposal areas and can accommodate future design expansions as needed. Currently, there are eight cells and two supercells in ERDF. Each supercell is the equivalent of two cells. During this reporting period (fiscal year 2022, extending from October 1, 2021, through September 30, 2022), approximately 8.52E+04 metric tons (9.39E+04 U.S. tons) of waste was disposed at ERDF. From ERDF inception through September 30, 2022, approximately 17.0 million metric tons (18.7 million U.S. tons) of waste has been disposed at ERDF, which equates to consumption of approximately 89.1% of the currently constructed disposal volume. According to the design of ERDF, the facility has the ability to be expanded as needed. As a condition of the DAS, disposal operations within ERDF must be in accordance with the waste acceptance criteria (ERDF-00011) that provide specific radionuclide disposal limits, waste form restrictions, and descriptions of acceptable waste packages in compliance with the requirements of DOE M 435-1.1. The ERDF waste acceptance criteria stipulate that waste destined for disposal at ERDF be controlled based on source, physical form, and contaminant concentration and activity levels. There have been no changes to the physical configuration of ERDF or to the waste forms (source, physical form, etc.). No new unreviewed disposal question screenings or evaluations have been generated in this reporting period. Therefore, there are no noted impacts to the PA, CA, DAS, or RWMB resulting from the evaluations and screenings. Sum-of-fractions analysis shows that the disposed inventory meets both the concentration and inventory threshold requirements. A sum-of-fractions value is computed for ERDF sensitive radionuclides contributing to the groundwater pathways and the air pathway inventory limits. Computed values were 5.50E-04 and 3.30E-03, respectively. The disposed waste inventory remained well under the PA imposed limits, as shown in Table 4 and Table 5 in the main text of this report. Required monitoring was satisfactorily completed during the fiscal year reporting period. Compliance with performance objectives were met as each of the reported values were well below the established limit. Overall, there are no substantive changes to primary PA assumptions or changes to the PA analysis conclusion; therefore, compliance with DOE O 435.1 and the DAS is maintained.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗