Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Computer Science - Operating Systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,405 records · Page 78

SU-E-J-222: Evaluation of Deformable Registration of PET/CT Images for Cervical Cancer Brachytherapy

Purpose: PET/CT provides important functional information for radiotherapy targeting of cervical cancer. However, repeated PET/CT procedures for external beam and subsequent brachytherapy expose patients to additional radiation and are not cost effective. Our goal is to investigate the possibility of propagating PET-active volumes for brachytherapy procedures through deformable image registration (DIR) of earlier PET/CT and ultimately to minimize the number of PET/CT image sessions required. Methods: Nine cervical cancer patients each received their brachytherapy preplanning PET/CT at the end of EBRT with a Syed template in place. The planning PET/CT was acquired on the day of brachytherapy treatment with the actual applicator (Syed or Tandem and Ring) and rigidly registered. The PET/CT images were then deformably registered creating a third (deformed) image set for target prediction. Regions of interest with standardized uptake values (SUV) greater than 65% of maximum SUV were contoured as target volumes in all three sets of PET images. The predictive value of the registered images was evaluated by comparing the preplanning and deformed PET volumes with the planning PET volume using Dice's coefficient (DC) and center-of-mass (COM) displacement. Results: The average DCs were 0.12±0.14 and 0.19±0.16 for rigid and deformable predicted target volumes, respectively. The average COM displacements were 1.9±0.9 cm and 1.7±0.7 cm for rigid and deformable registration, respectively. The DCs were improved by deformable registration, however, both were lower than published data for DIR in other modalities and clinical sites. Anatomical changes caused by different brachytherapy applicators could have posed a challenge to the DIR algorithm. The physiological change from interstitial needle placement may also contribute to lower DC. Conclusion: The clinical use of DIR in PET/CT for cervical cancer brachytherapy appears to be limited by applicator choice and requires further investigation.

60 APPLIED LIFE SCIENCES↗

SU-D-213-05: Design, Evaluation and First Applications of a Off-Site State-Of-The-Art 3D Dosimetry System

Purpose: To design, construct and commission a prototype in-house three dimensional (3D) dose verification system for stereotatic body radiotherapy (SBRT) verification at an off-site partner institution. To investigate the potential of this system to achieve sufficient performance (1mm resolution, 3% noise, within 3% of true dose reading) for SBRT verification. Methods: The system was designed utilizing a parallel ray geometry instigated by precision telecentric lenses and an LED 630nm light source. Using a radiochromic dosimeter, a 3D dosimetric comparison with our gold-standard system and treatment planning software (Eclipse) was done for a four-field box treatment, under gamma passing criteria of 3%/3mm/10% dose threshold. Post off-site installation, deviations in the system’s dose readout performance was assessed by rescanning the four-field box irradiated dosimeter and using line-profiles to compare on-site and off-site mean and noise levels in four distinct dose regions. As a final step, an end-to-end test of the system was completed at the off-site location, including CT-simulation, irradiation of the dosimeter and a 3D dosimetric comparison of the planned (Pinnacle{sup 3}) to delivered dose for a spinal SBRT treatment(12 Gy per fraction). Results: The noise level in the high and medium dose regions of the four field box treatment was relatively 5% pre and post installation. This reflects the reduction in positional uncertainty through the new design. This At 1mm dose voxels, the gamma pass rates(3%,3mm) for our in-house gold standard system and the off-site system were comparable at 95.8% and 93.2% respectively. Conclusion: This work will describe the end-to-end process and results of designing, installing, and commissioning a state-of-the-art 3D dosimetry system created for verification of advanced radiation treatments including spinal radiosurgery.

60 APPLIED LIFE SCIENCES↗

TU-A-304-02: Treatment Simulation, Planning and Delivery for SBRT

Increased use of SBRT and hypo fractionation in radiation oncology practice has posted a number of challenges to medical physicist, ranging from planning, image-guided patient setup and on-treatment monitoring, to quality assurance (QA) and dose delivery. This symposium is designed to provide updated knowledge necessary for the safe and efficient implementation of SBRT in various linac platforms, including the emerging digital linacs equipped with high dose rate FFF beams. Issues related to 4D CT, PET and MRI simulations, 3D/4D CBCT guided patient setup, real-time image guidance during SBRT dose delivery using gated/un-gated VMAT or IMRT, and technical advancements in QA of SBRT (in particular, strategies dealing with high dose rate FFF beams) will be addressed. The symposium will help the attendees to gain a comprehensive understanding of the SBRT workflow and facilitate their clinical implementation of the state-of-art imaging and planning techniques. Learning Objectives: Present background knowledge of SBRT, describe essential requirements for safe implementation of SBRT, and discuss issues specific to SBRT treatment planning and QA. Update on the use of multi-dimensional (3D and 4D) and multi-modality (CT, beam-level X-ray imaging, pre- and on-treatment 3D/4D MRI, PET, robotic ultrasound, etc.) for reliable guidance of SBRT. Provide a comprehensive overview of emerging digital linacs and summarize the key geometric and dosimetric features of the new generation of linacs for substantially improved SBRT. Discuss treatment planning and quality assurance issues specific to SBRT. Research grant from Varian Medical Systems.

60 APPLIED LIFE SCIENCES↗

TU-CD-304-11: Veritas 2.0: A Cloud-Based Tool to Facilitate Research and Innovation

Purpose: We introduce Veritas 2.0, a cloud-based, non-clinical research portal, to facilitate translation of radiotherapy research ideas to new delivery techniques. The ecosystem of research tools includes web apps for a research beam builder for TrueBeam Developer Mode, an image reader for compressed and uncompressed XIM files, and a trajectory log file based QA/beam delivery analyzer. Methods: The research beam builder can generate TrueBeam readable XML file either from scratch or from pre-existing DICOM-RT plans. DICOM-RT plan is first converted to XML format and then researcher can interactively modify or add control points to them. Delivered beam can be verified via reading generated images and analyzing trajectory log files. Image reader can read both uncompressed and HND-compressed XIM images. The trajectory log analyzer lets researchers plot expected vs. actual values and deviations among 30 mechanical axes. The analyzer gives an animated view of MLC patterns for the beam delivery. Veritas 2.0 is freely available and its advantages versus standalone software are i) No software installation or maintenance needed, ii) easy accessibility across all devices iii) seamless upgrades and iv) OS independence. Veritas is written using open-source tools like twitter bootstrap, jQuery, flask, and Python-based modules. Results: In the first experiment, an anonymized 7-beam DICOM-RT IMRT plan was converted to XML beam containing 1400 control points. kV and MV imaging points were inserted into this XML beam. In another experiment, a binary log file was analyzed to compare actual vs expected values and deviations among axes. Conclusions: Veritas 2.0 is a public cloud-based web app that hosts a pool of research tools for facilitating research from conceptualization to verification. It is aimed at providing a platform for facilitating research and collaboration. I am full time employee at Varian Medical systems, Palo Alto.

60 APPLIED LIFE SCIENCES↗

WE-D-204-06: An Open Source ImageJ CatPhan Analysis Tool

Purpose: The CatPhan is a popular QA device for assessing CT image quality. There are a number of software options which perform analysis of the CatPhan. However, there is often little ability for the user to adjust the analysis if it isn’t running properly, and these are all expensive options. An open source tool is an effective solution. Methods: To use the software, the user imports the CT as an image sequence in ImageJ. The user then scrolls to the slice with the lateral dots. The user then runs the plugin. If tolerance constraints are not already created, the user is prompted to enter them or to use generic tolerances. Upon completion of the analysis, the plugin calls pdfLaTex to compile the pdf report. There is a csv version of the report as well. A log of the results from all CatPhan scans is kept as a csv file. The user can use this to baseline the machine. Results: The tool is capable of detecting the orientation of the phantom. If the CatPhan was scanned backwards, one can simply flip the stack of images horizontally and proceed with the analysis. The analysis includes Sensitometry (estimating the effective beam energy), HU values and linearity, Low Contrast Visibility (using LDPE & Polystyrene), Contrast Scale, Geometric Accuracy, Slice Thickness Accuracy, Spatial resolution (giving the MTF using the line pairs as well as the point spread function), CNR, Low Contrast Detectability (including the raw data), Uniformity (including the Cupping Effect). Conclusion: This is a robust tool that analyzes more components of the CatPhan than other software options (with the exception of ImageOwl). It produces an elegant pdf and keeps a log of analyses for long-term tracking of the system. Because it is open source, users are able to customize any component of it.

60 APPLIED LIFE SCIENCES↗

SU-F-I-59: Quality Assurance Phantom for PET/CT Alignment and Attenuation Correction

Purpose: This study utilizes a commercial PET/CT phantom to investigate two specific properties of a PET/CT system: the alignment accuracy of PET images with those from CT used for attenuation correction and the accuracy of this correction in PET images. Methods: A commercial PET/CT phantom consisting of three aluminum rods, two long central cylinders containing uniform activity, and attenuating materials such as air, water, bone and iodine contrast was scanned using a standard PET/CT protocol. Images reconstructed with 2 mm slice thickness and a 512 by 512 matrix were obtained. The center of each aluminum rod in the PET and CT images was compared to evaluate alignment accuracy. ROIs were drawn on transaxial images of the central rods at each section of attenuating material to determine the corrected activity (in BQML). BQML values were graphed as a function of slice number to provide a visual representation of the attenuation-correction throughout the whole phantom. Results: Alignment accuracy is high between the PET and CT images. The maximum deviation between the two in the axial plane is less than 1.5 mm, which is less than the width of a single pixel. BQML values measured along different sections of the large central rods are similar among the different attenuating materials except iodine contrast. Deviation of BQML values in the air and bone sections from the water section is less than 1%. Conclusion: Accurate alignment of PET and CT images is critical to ensure proper calculation and application of CT-based attenuation correction. This study presents a simple and quick method to evaluate the two with a single acquisition. As the phantom also includes spheres of increasing diameter, this could serve as a straightforward means to annually evaluate the status of a modern PET/CT system.

60 APPLIED LIFE SCIENCES↗

SU-F-T-258: Efficacy of Exit Fluence-Based Dose Calculation for Prostate Radiation Therapy

Purpose: To investigate the efficacy of exit-fluence-based dose computation for prostate radiotherapy by determining if it estimates true dose more accurately than the original planning dose. Methods: Virtual exit-fluencebased dose computation was performed for 19 patients, each with 9–12 repeat CT images. For each patient, a 78 Gy treatment plan was created utilizing 5 mm CTV-to-PTV and OAR-to-PRV margins. A Monte Carlo framework was used to compute dose and exit-fluence images for the planning image and for each repeat CT image based on boney-anatomyaligned and prostate-centroid-aligned CTs. Identical source particles were used for the MC dose-computations on the planning and repeat CTs to maximize correlation. The exit-fluence-based dose and image were computed by multiplying source particle weights by FC(x,y)=FP(x,y)/FT(x,y), where (x,y) are the source particle coordinates projected to the exit-fluence plane and we denote the dose/fluence from the plan by (DP,FP), from the repeat-CT as (DT,FT), and the exit-fluence computation by (DFC,FFC). DFC mimics exit-fluence backprojection through the planning image as FT=FFC. Dose estimates were intercompared to judge the efficacy of exit-fluence-based dose computation. Results: Boney- and prostate-centroid aligned results are combined as there is no statistical difference between them, yielding 420 dose comparisons per dose-volume metric. DFC is more accurate than DP for 46%, 33%, and 44% of cases in estimating CTV D98, D50, and D2 respectively. DFC improved rectum D50 and D2 estimates 54% and 49% respectively and bladder D50 and D2 47 and 49% respectively. While averaged over all patients and images DFC and DP were within 3.1% of DT, they differed from DT by as much as 22% for GTV D98, 71% for the Bladder D50, 17% for Bladder D2, 19% for Rectum D2. Conclusion: Exit-fluence based dose computations infrequently improve CTV or OAR dose estimates and should be used with caution. Research supported in part by Varian Medical Systems.

60 APPLIED LIFE SCIENCES↗

MO-D-BRB-02: SBRT Treatment Planning and Delivery

Increased use of SBRT and hypofractionation in radiation oncology practice has posted a number of challenges to medical physicist, ranging from planning, image-guided patient setup and on-treatment monitoring, to quality assurance (QA) and dose delivery. This symposium is designed to provide current knowledge necessary for the safe and efficient implementation of SBRT in various linac platforms, including the emerging digital linacs equipped with high dose rate FFF beams. Issues related to 4D CT, PET and MRI simulations, 3D/4D CBCT guided patient setup, real-time image guidance during SBRT dose delivery using gated/un-gated VMAT/IMRT, and technical advancements in QA of SBRT (in particular, strategies dealing with high dose rate FFF beams) will be addressed. The symposium will help the attendees to gain a comprehensive understanding of the SBRT workflow and facilitate their clinical implementation of the state-of-art imaging and planning techniques. Learning Objectives: Present background knowledge of SBRT, describe essential requirements for safe implementation of SBRT, and discuss issues specific to SBRT treatment planning and QA. Update on the use of multi-dimensional and multi-modality imaging for reliable guidance of SBRT. Discuss treatment planning and QA issues specific to SBRT. Provide a comprehensive overview of emerging digital linacs and summarize the key geometric and dosimetric features of the new generation of linacs for substantially improved SBRT. NIH/NCI; Varian Medical Systems; F. Yin, Duke University has a research agreement with Varian Medical Systems. In addition to research grant, I had a technology license agreement with Varian Medical Systems.

60 APPLIED LIFE SCIENCES↗

High Velocity AI Cache (HVAC)

HVAC is a high-performance caching system designed for large-scale AI training workloads.

Khan, Awais [Oak Ridge National Laboratory (ORNL),↗

olcf/hsi_xfer

A wrapper for the `hsi` tool that provides a simple user interface to allow the most efficient and least stressful (to the system) way to migrate data off of HPSS filesystems

Wynne, JamesRiley [Oak Ridge National Laboratory (↗

Clickstream data yields high-resolution maps of science

Intricate maps of science have been created from citation data to visualize the structure of scientific activity. However, most scientific publications are now accessed online. Scholarly web portals record detailed log data at a scale that exceeds the number of all existing citations combined. Such log data is recorded immediately upon publication and keeps track of the sequences of user requests (clickstreams) that are issued by a variety of users across many different domains. Given these advantagees of log datasets over citation data, we investigate whether they can produce high-resolution, more current maps of science.

99 GENERAL AND MISCELLANEOUS↗

Accelerated Climate Modeling For Energy

This is the final report on the work of the New York University team to the DOE Accelerated Climate Modeling For Energy (ACME) project. NYU was one of the original developers of the UV-CDAT tool for climate data analysis, which is being used in ACME. NYU primarily focused on the analysis package graphical user interface, workflow and provenance functionality. The most significant activities in the last year of the grant were the development of the new plotting system in UVCMetrics package and the package EzLinePlot for 1D plots which are described in detail.

54 ENVIRONMENTAL SCIENCES↗

ComPort: Rigorous Testing Methods to Safeguard Software Porting (Final UW Report)

This report summarizes the University of Washington’s contributions to the ComPort project, Rigorous Testing Methods to Safeguard Software Porting, funded under the U.S. Department of Energy, Office of Science, Office of Advanced Scientific Computing Research (ASCR), award number DE-SC0022081. UW’s work addressed numerics-driven correctness challenges arising in heterogeneous and rapidly evolving computing environments. Our efforts focused on developing interactive analysis tools, correctness-preserving rewriting systems, semantic-aware code-transformation infrastructure, and multi-language support for reproducible numerical experiments.

97 MATHEMATICS AND COMPUTING↗

Digital Twin: Visualizing the Future of the Power Grid [Slides]

The energy systems are generating data at a scale and complexity that increasingly outpaces our ability to analyze it. This talk argues that rigorous, large-scale visualization is a critical tool for meeting that challenge. Drawing on recent work in the Computational Science Center at the National Laboratory of the Rockies, we trace a progression of visualization research culminating in an immersive digital twin of a real campus power grid. Along the way, we examine why visualization matters at all, where widely-used techniques quietly fail, and what becomes analytically possible when you match the display environment to the scale of the problem.

24 POWER TRANSMISSION AND DISTRIBUTION↗

iGlobe: an interactive visualization and analysis framework for geospatial data

We demonstrate an interactive visualization and analysis system for integrating climate data with other geospatial data sets, such as environmental and demographic data. The \eviz system is a desktop-based visualization and analysis environment which allows seamless integration of multiple geospatial data sets from varied sources and provides an interface to interactively analyze the different data sets and apply sophisticated data analysis and mining algorithms in a near real time fashion. The framework is highly desirable in domains such as earth and climate sciences where great emphasis is placed on simultaneous analysis of different data sets such as remote sensing images, climate model simulation outputs, and other environmental and demographic databases, to understand weather and climate systems and the impact of climate change on nature and people.

54 ENVIRONMENTAL SCIENCES↗

A shallow water model for dense gas simulation in urban areas

Large quantities of toxic chemicals are stored at industrial facilities and transported around the country via train and truck. In the event of an accidental release, many of these chemicals are released as heavier-than-air gases that stay low to the ground as they are transported by the wind . Breathing height concentrations can remain high due to reduced vertical mixing and hazard zone coverage area can be larger due to near-source gravitational slumping . A number of fast-response dense gas dispersion models have been developed and are routinely used to deal with heavier-than-air releases over unobstructed terrain. If a release were to occur in a built-up environment, however, the effects of buildings and other obstacles will significantly alter the initial spreading, the transport direction, and the amount of mixing of the dense gas cloud . We have developed a new fast-running dense gas dispersion model that is intended for handling releases in cities and at large industrial facilities. In this paper we describe the scheme employed and how the model has been integrated into the Quick Urban & Industrial Complex (QUIC) dispersion modeling system.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Quantum Information: Opportunities and Challenges

Modern society is shaped by the ability to transmit, manipulate, and store large amounts of information. Although we tend to think of information as abstract, information is physical, and computing is a physical process. How then should we understand information in a quantum world, in which physical systems may exist in multiple states at once and are altered by the very act of observation? This question has evolved into an exciting new field of research called Quantum Information (QI). QI challenges many accepted rules and practices in computer science. For example, a quantum computer would turn certain hard problems into soft problems, and would render common computationally-secure encryption methods (such as RSA) insecure. At the same time, quantum communication would provide an unprecedented kind of intrinsic information security at the level of the smallest physical objects used to store or transmit the information. This talk provides a general introduction to the subject of quantum information and its relevance to cyber security. In the first part, two of the stranger aspects of quantum physics namely, superposition and uncertainty are explained, along with their relation to the concept of information. These ideas are illustrated with a few examples: quantum ID cards, quantum key distribution, and Grover s quantum search algorithm. The state-of-the-art in quantum computing and communication hardware is then discussed, along with the daunting technological challenges that must be overcome. Relevant experimental and theoretical efforts at ORNL are highlighted. The talk concludes with speculations on the short- and long-term impact of quantum information on cyber security.

97 MATHEMATICS AND COMPUTING↗

Macro-System Model: A Federated Object Model for Cross-Cutting Analysis of Hydrogen Production, Delivery, Consumption and Associated Emissions

The introduction of hydrogen as an energy carrier for light-duty vehicles involves concomitant technological progress in several directions, such as production, delivery, consumption, and related emissions. To analyze each of these, a suite of corresponding models have been developed by the DOE, involving inputs from several national laboratories. The macro-system model is being developed as a cross-cutting analysis tool which combines a set of hydrogen technology analysis models. Within the macro-system model (MSM), federated simulation framework used for consistent data transfer between the component models. The framework is built to suit cross-model as well as cross-platform data exchange and will involve features of 'over-the-net' computation.

08 HYDROGEN↗