Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Computational imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,405 records · Page 78

Advanced ballistic range technology

Optical images, such as experimental interferograms, schlieren, and shadowgraphs, are routinely used to identify and locate features in experimental flow fields and for validating computational fluid dynamics (CFD) codes. Interferograms can also be used for comparing experimental and computed integrated densities. By constructing these optical images from flow-field simulations, one-to-one comparisons of computation and experiment are possible. During the period from February 1, 1992, to November 30, 1992, work has continued on the development of CISS (Constructed Interferograms, Schlieren, and Shadowgraphs), a code that constructs images from ideal- and real-gas flow-field simulations. In addition, research connected with the automated film-reading system and the proposed reactivation of the radiation facility has continued.

Yates, Leslie A.↗

Plot2Spectra: an automatic spectra extraction tool

Scientists cannot easily make use of numerical data encoded in plot images, such as of spectroscopy data, in scientific literature. Plot2Spectra was developed to use computer vision tools to automatically digitize plot images.

Jiang, Weixin↗

Image Matching Using Generalized Hough Transforms

An image matching system specifically designed to match dissimilar images is described. A set of blobs and ribbons is first extracted from each image, and then generalized Hough transform techniques are used to match these sets and compute the transformation that best registers the image. An example of the application of the approach to one pair of remotely sensed images is presented.

Davis, L. S.↗

LANDSAT-4 Radiometric and Geometric Correction and Image Enhancement Results

Techniques were developed or improved to calibrate, enhance, and geometrically correct LANDSAT-4 satellite data. Statistical techniques to correct data radiometry were evaluated and were found to minimize striping and banding. Conventional techniques cause striping even with perfect calibration parameters. Intensity enhancement techniques were improved to display image data with large variation in intensity or brightness. Data were geometrically corrected to conform to a 1:100,000 map reference and image products produced with the map overlay. It is shown that these products can serve as accurate map products. A personal computer was experimentally used for digital image processing.

Bernstein, R.↗

Multisensor Data Integration Techniques

The availability of data from sensors operating in several different wavelength regions had led to the development of new techniques and strategies for both data management and image analysis. Work is ongoing to develop computer techniques for analysis of integrated data sets. These techniques include coregistration of multisensor images, rectification of radar images in areas of topographic relief to ensure pixel to pixel registration with planimetric data sets, calibration of data so that signatures can be applied to remote areas, normalization of data acquired with disparate sensors and determination of extended spectral signatures of surface units. In addition, software is being developed to analyze coregistrated digital terrain and image data so that automated stratigraphic and structural analyses can be performed. These software procedures include: strike and dip determination, terrain profile generation, stratigraphic column generation, stratigraphic thickness measurements, structural cross-section generation, and creation of 3-D block diagrams. These techniques were applied to coregistered LANDSAT 4 Thematic Mapper (TM), Thermal Infrared Multispectral Scanner (TIMS), and multipolarization synthetic aperture radar (SAR) data of the Wind River Basin in Wyoming.

Evans, D. L.↗

Examining The Subroutine Structure Of A VAX Image

Command program analyzes executable components of another program. SCANEXE, a command program for DEC VAX computer used to scan VMS run-time image and print information about routines it uses. Lists each routine, with entry point, and how many times called. Information on progress of program printed at user's option as analyzing various executable components. Relies on "debug" records included by default in ".EXE" files. If image linked with "/NOTRACEBACK" option, cannot provide necessary information. Written in C (83 percent), FORTRAN 77 (13 percent), and Assembler (4 percent).

Scott, Peter J.↗

Image processing software for imaging spectrometry

The paper presents a software system, Spectral Analysis Manager (SPAM), which has been specifically designed and implemented to provide the exploratory analysis tools necessary for imaging spectrometer data, using only modest computational resources. The basic design objectives are described as well as the major algorithms designed or adapted for high-dimensional images. Included in a discussion of system implementation are interactive data display, statistical analysis, image segmentation and spectral matching, and mixture analysis.

Mazer, Alan S.↗

Temperature, Pressure, and Infrared Image Survey of an Axisymmetric Heated Exhaust Plume

The focus of this research is to numerically predict an infrared image of a jet engine exhaust plume, given field variables such as temperature, pressure, and exhaust plume constituents as a function of spatial position within the plume, and to compare this predicted image directly with measured data. This work is motivated by the need to validate computational fluid dynamic (CFD) codes through infrared imaging. The technique of reducing the three-dimensional field variable domain to a two-dimensional infrared image invokes the use of an inverse Monte Carlo ray trace algorithm and an infrared band model for exhaust gases. This report describes an experiment in which the above-mentioned field variables were carefully measured. Results from this experiment, namely tables of measured temperature and pressure data, as well as measured infrared images, are given. The inverse Monte Carlo ray trace technique is described. Finally, experimentally obtained infrared images are directly compared to infrared images predicted from the measured field variables.

Nelson, Edward L.↗

Quantifying Impacts of Biomass Pelletization on Fast Pyrolysis Using a Single-Particle Reactor, X-ray Computed Tomography, and Computational Modeling

The pore structure and density of lignocellulosic feedstocks dictate intraparticle transport phenomena and thereby play an important role in thermochemical conversion processes such as fast pyrolysis for biofuel and biochemical production. Variations in microstructure are inherent from different biomass species and can be introduced by preprocessing techniques such as cutting and pelletization. Morphological changes also occur during conversion and lead to vastly different pore structures and behavior during pyrolysis, which impact required conversion times and product distributions. The current work presents a comprehensive comparison of fast pyrolysis of neat and pelletized pine feedstocks, which includes single-particle experiments, modeling, and 3D imaging by X-ray computed tomography (XCT). The particle-scale model included anisotropic heat and mass transport in a shrinking particle with pyrolysis reactions based on the CRECK mechanism with boundary conditions informed by reactor-scale simulations of the single-particle reactor. The models were validated by measurements of the temperature and mass loss from single-particle pyrolysis experiments of neat and pelletized pine. Quantitative analysis of XCT geometries revealed that pyrolytic conversion yielded chars with increased porosity and permeability compared to the unpyrolyzed materials, along with decreased tortuosity and anisotropy. Pelletization of the pine feedstock resulted in a much denser, less permeable material, which converted slower and produced more residual char after pyrolysis compared to neat pine. The results from particle modeling revealed that accounting for the dynamic and anisotropic heat and mass transport caused by differences in pore structure is critical to achieving agreement with experimental results. Overall, this study highlights the dramatic differences in conversion behavior imparted by pelletization and the importance of capturing microstructural attributes in computational models to guide the design and optimization of pyrolysis processes for specific biomass feedstocks.

09 BIOMASS FUELS↗

Modeling Images of Natural 3D Surfaces: Overview and Potential Applications

Generative models of natural images have long been used in computer vision. However, since they only describe the of 2D scenes, they fail to capture all the properties of the underlying 3D world. Even though such models are sufficient for many vision tasks a 3D scene model is when it comes to inferring a 3D object or its characteristics. In this paper, we present such a generative model, incorporating both a multiscale surface prior model for surface geometry and reflectance, and an image formation process model based on realistic rendering, the computation of the posterior model parameter densities, and on the critical aspects of the rendering. We also how to efficiently invert the model within a Bayesian framework. We present a few potential applications, such as asteroid modeling and Planetary topography recovery, illustrated by promising results on real images.

Jalobeanu, Andre↗

Pyramid image codes

All vision systems, both human and machine, transform the spatial image into a coded representation. Particular codes may be optimized for efficiency or to extract useful image features. Researchers explored image codes based on primary visual cortex in man and other primates. Understanding these codes will advance the art in image coding, autonomous vision, and computational human factors. In cortex, imagery is coded by features that vary in size, orientation, and position. Researchers have devised a mathematical model of this transformation, called the Hexagonal oriented Orthogonal quadrature Pyramid (HOP). In a pyramid code, features are segregated by size into layers, with fewer features in the layers devoted to large features. Pyramid schemes provide scale invariance, and are useful for coarse-to-fine searching and for progressive transmission of images. The HOP Pyramid is novel in three respects: (1) it uses a hexagonal pixel lattice, (2) it uses oriented features, and (3) it accurately models most of the prominent aspects of primary visual cortex. The transform uses seven basic features (kernels), which may be regarded as three oriented edges, three oriented bars, and one non-oriented blob. Application of these kernels to non-overlapping seven-pixel neighborhoods yields six oriented, high-pass pyramid layers, and one low-pass (blob) layer.

Watson, Andrew B.↗

Experimental Investigation of Jet Impingement Heat Transfer Using Thermochromic Liquid Crystals

Jet impingement cooling of a hypersonic airfoil leading edge is experimentally investigated using thermochromic liquid crystals (TLCS) to measure surface temperature. The experiment uses computer data acquisition with digital imaging of the TLCs to determine heat transfer coefficients during a transient experiment. The data reduction relies on analysis of a coupled transient conduction - convection heat transfer problem that characterizes the experiment. The recovery temperature of the jet is accounted for by running two experiments with different heating rates, thereby generating a second equation that is used to solve for the recovery temperature. The resulting solution requires a complicated numerical iteration that is handled by a computer. Because the computational data reduction method is complex, special attention is paid to error assessment. The error analysis considers random and systematic errors generated by the instrumentation along with errors generated by the approximate nature of the numerical methods. Results of the error analysis show that the experimentally determined heat transfer coefficients are accurate to within 15%. The error analysis also shows that the recovery temperature data may be in error by more than 50%. The results show that the recovery temperature data is only reliable when the recovery temperature of the jet is greater than 5 C, i.e. the jet velocity is in excess of 100 m/s. Parameters that were investigated include nozzle width, distance from the nozzle exit to the airfoil surface, and jet velocity. Heat transfer data is presented in graphical and tabular forms. An engineering analysis of hypersonic airfoil leading edge cooling is performed using the results from these experiments. Several suggestions for the improvement of the experimental technique are discussed.

Dempsey, Brian Paul↗

Improved Scanners for Microscopic Hyperspectral Imaging

Improved scanners to be incorporated into hyperspectral microscope-based imaging systems have been invented. Heretofore, in microscopic imaging, including spectral imaging, it has been customary to either move the specimen relative to the optical assembly that includes the microscope or else move the entire assembly relative to the specimen. It becomes extremely difficult to control such scanning when submicron translation increments are required, because the high magnification of the microscope enlarges all movements in the specimen image on the focal plane. To overcome this difficulty, in a system based on this invention, no attempt would be made to move either the specimen or the optical assembly. Instead, an objective lens would be moved within the assembly so as to cause translation of the image at the focal plane: the effect would be equivalent to scanning in the focal plane. The upper part of the figure depicts a generic proposed microscope-based hyperspectral imaging system incorporating the invention. The optical assembly of this system would include an objective lens (normally, a microscope objective lens) and a charge-coupled-device (CCD) camera. The objective lens would be mounted on a servomotor-driven translation stage, which would be capable of moving the lens in precisely controlled increments, relative to the camera, parallel to the focal-plane scan axis. The output of the CCD camera would be digitized and fed to a frame grabber in a computer. The computer would store the frame-grabber output for subsequent viewing and/or processing of images. The computer would contain a position-control interface board, through which it would control the servomotor. There are several versions of the invention. An essential feature common to all versions is that the stationary optical subassembly containing the camera would also contain a spatial window, at the focal plane of the objective lens, that would pass only a selected portion of the image. In one version, the window would be a slit, the CCD would contain a one-dimensional array of pixels, and the objective lens would be moved along an axis perpendicular to the slit to spatially scan the image of the specimen in pushbroom fashion. The image built up by scanning in this case would be an ordinary (non-spectral) image. In another version, the optics of which are depicted in the lower part of the figure, the spatial window would be a slit, the CCD would contain a two-dimensional array of pixels, the slit image would be refocused onto the CCD by a relay-lens pair consisting of a collimating and a focusing lens, and a prism-gratingprism optical spectrometer would be placed between the collimating and focusing lenses. Consequently, the image on the CCD would be spatially resolved along the slit axis and spectrally resolved along the axis perpendicular to the slit. As in the first-mentioned version, the objective lens would be moved along an axis perpendicular to the slit to spatially scan the image of the specimen in pushbroom fashion.

Mao, Chengye↗

Advances in Measurement of Skin Friction in Airflow

The surface interferometric skin-friction (SISF) measurement system is an instrument for determining the distribution of surface shear stress (skin friction) on a wind-tunnel model. The SISF system utilizes the established oil-film interference method, along with advanced image-data-processing techniques and mathematical models that express the relationship between interferograms and skin friction, to determine the distribution of skin friction over an observed region of the surface of a model during a single wind-tunnel test. In the oil-film interference method, a wind-tunnel model is coated with a thin film of oil of known viscosity and is illuminated with quasi-monochromatic, collimated light, typically from a mercury lamp. The light reflected from the outer surface of the oil film interferes with the light reflected from the oil-covered surface of the model. In the present version of the oil-film interference method, a camera captures an image of the illuminated model and the image in the camera is modulated by the interference pattern. The interference pattern depends on the oil-thickness distribution on the observed surface, and this distribution can be extracted through analysis of the image acquired by the camera. The oil-film technique is augmented by a tracer technique for observing the streamline pattern. To make the streamlines visible, small dots of fluorescentchalk/oil mixture are placed on the model just before a test. During the test, the chalk particles are embedded in the oil flow and produce chalk streaks that mark the streamlines. The instantaneous rate of thinning of the oil film at a given position on the surface of the model can be expressed as a function of the instantaneous thickness, the skin-friction distribution on the surface, and the streamline pattern on the surface; the functional relationship is expressed by a mathematical model that is nonlinear in the oil-film thickness and is known simply as the thin-oil-film equation. From the image data acquired as described, the time-dependent oil-thickness distribution and streamline pattern are extracted and by inversion of the thin-oil-film equation it is then possible to determine the skin-friction distribution. In addition to a quasi-monochromatic light source, the SISF system includes a beam splitter and two video cameras equipped with filters for observing the same area on a model in different wavelength ranges, plus a frame grabber and a computer for digitizing the video images and processing the image data. One video camera acquires the interference pattern in a narrow wavelength range of the quasi-monochromatic source. The other video camera acquires the streamline image of fluorescence from the chalk in a nearby but wider wavelength range. The interference- pattern and fluorescence images are digitized, and the resulting data are processed by an algorithm that inverts the thin-oil-film equation to find the skin-friction distribution.

Brown, James L.↗

Seismic Imager Space Telescope

A concept has been developed for a geostationary seismic imager (GSI), a space telescope in geostationary orbit above the Pacific coast of the Americas that would provide movies of many large earthquakes occurring in the area from Southern Chile to Southern Alaska. The GSI movies would cover a field of view as long as 300 km, at a spatial resolution of 3 to 15 m and a temporal resolution of 1 to 2 Hz, which is sufficient for accurate measurement of surface displacements and photometric changes induced by seismic waves. Computer processing of the movie images would exploit these dynamic changes to accurately measure the rapidly evolving surface waves and surface ruptures as they happen. These measurements would provide key information to advance the understanding of the mechanisms governing earthquake ruptures, and the propagation and arrest of damaging seismic waves. GSI operational strategy is to react to earthquakes detected by ground seismometers, slewing the satellite to point at the epicenters of earthquakes above a certain magnitude. Some of these earthquakes will be foreshocks of larger earthquakes; these will be observed, as the spacecraft would have been pointed in the right direction. This strategy was tested against the historical record for the Pacific coast of the Americas, from 1973 until the present. Based on the seismicity recorded during this time period, a GSI mission with a lifetime of 10 years could have been in position to observe at least 13 (22 on average) earthquakes of magnitude larger than 6, and at least one (2 on average) earthquake of magnitude larger than 7. A GSI would provide data unprecedented in its extent and temporal and spatial resolution. It would provide this data for some of the world's most seismically active regions, and do so better and at a lower cost than could be done with ground-based instrumentation. A GSI would revolutionize the understanding of earthquake dynamics, perhaps leading ultimately to effective warning capabilities, to improved management of earthquake risk, and to improved public safety policies. The position of the spacecraft, its high optical quality, large field of view, and large field of regard will make it an ideal platform for other scientific studies. The same data could be simply reused for other studies. If different data, such as multi-spectral data, is required, additional instruments could share the telescope.

Sidick, Erkin↗

Image quality against metric capability of an aerial camera

Glass plate targets containing multiple contrast three bar patterns and a military standard resolution target were photographed through a light-source collimator-camera system. The glass plate targets and images were then scanned. Through a computer plotting program selected portions of the scanned items were presented. The plots were then measured and analyzed to obtain information of image quality parameters and effects. The measurement errors are discussed together with aspects of resolution determination.

Ghosh, S. K.↗

Software For Monitoring VAX Computer Systems

VAX Continuous Monitoring System (VAXCMS) computer program developed at NASA Headquarters to aid system managers in monitoring performances of VAX computer systems through generation of graphic images summarizing trends in performance metrics over time. VAXCMS written in DCL and VAX FORTRAN for use with DEC VAX-series computers running VMS 5.1 or later.

Farkas, Les↗

Discrete Fourier Transform in a Complex Vector Space

An image-based phase retrieval technique has been developed that can be used on board a space based iterative transformation system. Image-based wavefront sensing is computationally demanding due to the floating-point nature of the process. The discrete Fourier transform (DFT) calculation is presented in "diagonal" form. By diagonal we mean that a transformation of basis is introduced by an application of the similarity transform of linear algebra. The current method exploits the diagonal structure of the DFT in a special way, particularly when parts of the calculation do not have to be repeated at each iteration to converge to an acceptable solution in order to focus an image.

Dean, Bruce H.↗