Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Coils”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,405 records · Page 78

Low Distortion Welded Joints for NCSX

The National Compact Stellarator Experiment (NCSX) required precise positioning of the field coils in order to generate suitable magnetic fields. A set of three modular field coils were assembled to form the Half Field-Period Assemblies (HPA). Final assembly of the HPA required a welded shear plate to join individual coils in the nose region due to the geometric limitations and the strength constraints. Each of the modular coil windings was wound on a stainless steel alloy (Stellalloy) casting. The alloy is similar to austenitic 316 stainless steel. During the initial welding trials, severe distortion, of approximately 1/16", was observed in the joint caused by weld shrinkage. The distortion was well outside the requirements of the design. Solutions were attempted through several simultaneous routes. The joint design was modified, welding processes were changed, and specialized heat reduction techniques were utilized. A final joint design was selected to reduce the amount of weld material needed to be deposited, while maintaining adequate penetration and strength. Several welding processes and techniques using Miller Axcess equipment were utilized that significantly reduced heat input. The final assembly of the HPA was successful. Distortion was controlled to 0.012", well within the acceptable design tolerance range of 0.020" over a 3.5 foot length.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Shell-Based Support Structures for Nb3Sn Accelerator Quadrupole Magnets

Shell-based support structures are being fabricated and tested as part of the development of large-aperture Nb{sub 3}Sn superconducting quadrupoles for future upgrades of the LHC Interaction Regions. These structures utilize water pressurized bladders for room-temperature pre-load control, and rely on a pre-tensioned aluminum shell to deliver a substantial part of the coil pre-stress during cool-down. The coil final pre-load is therefore monotonically approached from below, without overstressing the strain-sensitive conductor. This method has been adopted by the US LARP collaboration to test subscale racetrack coils (SQ series), 1 m long cos-theta coils (TQS series), and 4 m long magnets (LRS and LQS series). We present recent progress in the development of shell-based support structures, with a description of the principles of operations and the future plans.

43 PARTICLE ACCELERATORS↗

Permanent magnet machine with windings having strand transposition

This document discusses, among other things, a stator with transposition between the windings or coils. The coils are free from transposition to increase the fill factor of the stator slots. The transposition at the end connections between an inner coil and an outer coil provide transposition to reduce circulating current loss. The increased fill factor reduces further current losses. Such a stator is used in a dual rotor, permanent magnet machine, for example, in a compressor pump, wind turbine gearbox, wind turbine rotor.

17 WIND ENERGY↗

High magnetic field ohmically decoupled non-contact technology

Methods and apparatus are described for high magnetic field ohmically decoupled non-contact treatment of conductive materials in a high magnetic field. A method includes applying a high magnetic field to at least a portion of a conductive material; and applying an inductive magnetic field to at least a fraction of the conductive material to induce a surface current within the fraction of the conductive material, the surface current generating a substantially bi-directional force that defines a vibration. The high magnetic field and the inductive magnetic field are substantially confocal, the fraction of the conductive material is located within the portion of the conductive material and ohmic heating from the surface current is ohmically decoupled from the vibration. An apparatus includes a high magnetic field coil defining an applied high magnetic field; an inductive magnetic field coil coupled to the high magnetic field coil, the inductive magnetic field coil defining an applied inductive magnetic field; and a processing zone located within both the applied high magnetic field and the applied inductive magnetic field. The high magnetic field and the inductive magnetic field are substantially confocal, and ohmic heating of a conductive material located in the processing zone is ohmically decoupled from a vibration of the conductive material.

36 MATERIALS SCIENCE↗

Stueckelberg oscillations in nonadiabatic spin transitions of an electron spin-polarized {sup 4}He{sup +} ion beam

We investigated the nonadiabatic transition of an electron spin-polarized {sup 4}He{sup +} ion beam in the energy range of 0.2-2 keV. We successfully evaluated the spin polarization of the He{sup +} ion beam passing through a solenoid coil by measuring the elastically scattered ion intensity from the magnetized Fe(100) target. We observed that the beam polarization exhibited sinusoidal magnetic oscillation after passing through the coil. Furthermore, the beam polarization almost completely reversed with single periodicity in this oscillation. By comparison with the theory of the double-passage nonadiabatic transition, we concluded that this oscillation corresponds to the Stueckelberg oscillation in beam polarization. Thus, we propose that the quantum interference between the nonadiabatic transitions using a single solenoid coil acts as an effective spin flipper.

74 ATOMIC AND MOLECULAR PHYSICS↗

Over Voltage in a Multi-sectioned Solenoid during a Quenching

Accurate analysis of over voltage in the superconducting solenoid during a quench is one of the bases for quench protection system design. Classical quench simulation methods can only give rough estimation of the over voltage within a magnet coil. In this paper, for multi-sectioned superconducting solenoid, based on the classical assumption of ellipsoidal normal zone, three-dimension al temperature results are mapped to the one-dimension of the wire, the temperature distribution along the wire and the resistances of each turn are obtained. The coil is treated as circuit comprised of turn resistances, turn self and mutual inductances. The turn resistive voltage, turn inductive voltage, and turn resultant voltage along the wire are calculated. As a result, maximum internal voltages, the layer-to-layer voltages and the turn-to-turn voltages are better estimated. Utilizing this method, the over voltage of a small solenoid and a large solenoid during quenching have been studied. The result shows that this method can well improve the over voltage estimate, especially when the coil is larger.

42 ENGINEERING↗

Descriptions of a linear device developed for research on advanced plasma imaging and dynamics

The research on advanced plasma imaging and dynamics (RAPID) device is a newly developed linear electron cyclotron resonance (ECR) plasma device. It has a variety of axial magnetic field profiles provided by eight water-cooled magnetic coils and two dc power supplies. The positions of the magnetic coils are freely adjustable along the axial direction and the power supplies can be operated with many combinations of electrical wiring to the coils. A 6 kW 2.45 GHz magnetron is used to produce steady-state ECR plasmas with central magnetic fields of 875 and/or 437.5 G (second harmonic). The cylindrical stainless steel vacuum chamber is 300 mm in diameter and 750 mm in length and has eight radial and ten axial ports including 6-in. and 8-in. viewing windows for heating and diagnostics. Experimental observation of ECR plasma heating has been recently carried out during the initial plasma operation. The main diagnostic systems including a 94 GHz heterodyne interferometer, a high-resolution 25 channel one-dimensional array spectrometer, a single channel survey spectrometer, and an electric probe have been also prepared. The RAPID device is a flexible simulator for the understanding of tokamak edge plasma physics and new diagnostic system development. In this work, we describe the RAPID device and initial operation results.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Pantechnik new superconducting ion source: PantechniK Indian Superconducting Ion Source

The new ECR ion source PantechniK Indian Superconducting Ion Source (PKISIS) was recently commissioned at Pantechnik. Three superconducting coils generate the axial magnetic field configuration, while the radial magnetic field is done with the multi-layer permanent magnets. Special care was devoted to the design of the hexapolar structure, allowing a maximum magnetic field of 1.32 T at the wall of the 82 mm diameter plasma chamber. The three superconducting coils using low temperature superconducting wires are cooled by a single double stage cryo-cooler (4.2 K). Cryogen-free technology is used, providing reliability and easy maintenance at low cost. The maximum installed RF power (18.0 GHz) is of 2 kW. Metallic beams can be produced with an oven (T{sub max}= 1400 deg. C) installed with an angle of 5 deg. with respect to the source axis or a sputtering system, mounted on the axis of the source. The beam extraction system is constituted of three electrodes in accel-decel configuration. The new source of Pantechnik is conceived for reaching optimum performances at 18 GHz RF frequencies. PKISIS magnetic fields are 2.1 T axial B{sub inj} and 1.32 T radial field in the wall, variable B{sub min} with an independent coil and a large and opened extraction region. Moreover, PKISIS integrates modern design concepts, like RF direct injection (2 kW availability), dc-bias moving disk, out-of-axis oven and axial sputtering facility for metal beams. Finally, PKISIS is also conceived in order to operate in a high-voltage platform with minor power consumption.

43 PARTICLE ACCELERATORS↗

Note: Experimental platform for magnetized high-energy-density plasma studies at the omega laser facility

Here, an upgrade of the pulsed magnetic field generator magneto-inertial fusion electrical discharge system [O. Gotchev et al., Rev. Sci. Instrum. 80, 043504 (2009)] is described. The device is used to study magnetized high-energy-density plasma and is capable of producing a pulsed magnetic field of tens of tesla in a volume of a few cubic centimeters. The magnetic field is created by discharging a high-voltage capacitor through a small wire-wound coil. The coil current pulse has a duration of about 1 μs and a peak value of 40 kA. Compared to the original, the updated version has a larger energy storage and improved switching system. In addition, magnetic coils are fabricated using 3-D printing technology which allows for a greater variety of the magnetic field topology.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Extending the operational boundaries of RMP-ELM suppression with optimized 3D field control

The use of 3D magnetic fields is one of the promising approaches to control edge localized modes (ELMs), and ITER has plans to utilize a flexible 3D coil set for ELM suppression using 3D fields. This study focuses on optimizing the 3D field spectrum to expand the operational window for n = 1 resonant magnetic perturbation (RMP) ELM suppression in KSTAR. The optimized n = 1 RMP effectively suppresses ELMs throughout the entire H-mode discharge, including the first ELM crash, while avoiding the onset of disruptive locked modes in low-density L-mode plasmas. The predicted suppression window aligns well with experimental data, highlighting the challenges and solutions of using n = 1 RMP at low densities. Moreover, the optimization successfully achieved n = 1 RMP ELM suppression for the first time in ITER-relevant q 95 and shaping conditions, including cases with q95 as low as 3.6, as well as other q 95 and shape configurations. This highlights the importance and utility of 3D coil optimization while emphasizing the potential of long-wavelength low-n RMP, which will be valuable for ex-vessel coils designed to avoid complications of nuclear degradation.

3D magnetic field control↗

Progress in the Long ${\rm Nb}_{3}{\rm Sn}$ Quadrupole R&D by LARP

After the successful test of the first long Nb 3 Sn quadrupole (LQS01) the US LHC Accelerator Research Program (LARP, a collaboration of BNL, FNAL, LBNL and SLAC) is assessing training memory, reproducibility, and other accelerator quality features of long Nb 3 Sn quadrupole magnets. LQS01b (a reassembly of LQS01 with more uniform and higher pre-stress) was subjected to a full thermal cycle and reached the previous plateau of 222 T/m at 4.5 K in two quenches. A new set of four coils, made of the same type of conductor used in LQS01 (RRP 54/61 by Oxford Superconducting Technology), was assembled in the LQS01 structure and tested at 4.5 K and lower temperatures. The new magnet (LQS02) reached the target gradient (200 T/m) only at 2.6 K and lower temperatures, at intermediate ramp rates. The preliminary test analysis, here reported, showed a higher instability in the limiting coil than in the other coils of LQS01 and LQS02.

43 PARTICLE ACCELERATORS↗

SU-G-JeP2-15: Proton Beam Behavior in the Presence of Realistic Magnet Fields

Purpose: To investigate the effects of magnetic fields on proton therapy beams for integration with MRI. Methods: 3D magnetic fields from an open-bore superconducting MRI model (previously developed by our group) and 3D magnetic fields from an in-house gradient coil design were applied to various mono energetic proton pencil beam (80MeV to 250MeV) simulations. In all simulations, the z-axis of the simulation geometry coincided with the direction of the B0 field and magnet isocentre. In each simulation, the initial beam trajectory was varied. The first set of simulations performed was based on analytic magnetic force equations (analytic simulations), which could be rapidly calculated yet were limited to propagating proton beams in vacuum. The second set is full Monte Carlo (MC) simulations, which used GEANT4 MC toolkit. Metrics such as the beam position and dose profiles were extracted. Comparisons between the cases with and without magnetic fields present were made. Results: The analytic simulations served as verification checks for the MC simulations when the same simulation geometries were used. The results of the analytic simulations agreed with the MC simulations performed in vacuum. The presence of the MRI’s static magnetic field causes proton pencil beams to follow a slight helical trajectory when there were some initial off-axis components. The 80MeV, 150MeV, and 250MeV proton beams rotated by 4.9o, 3.6o, and 2.8o, respectively, when they reached z=0cm. The deflections caused by gradient coils’ magnetic fields show spatially invariant patterns with a maximum range of 0.5mm at z=0cm. Conclusion: This investigation reveals that both the MRI’s B0 and gradient magnetic fields can cause small but observable deflections of proton beams at energies studied. The MRI’s static field caused a rotation of the beam while the gradient coils’ fields effects were spatially invariant. Dr. B Gino Fallone is a co-founder and CEO of MagnetTx Oncology Solutions (under discussions to license Alberta bi-planar linac MR for commercialization)

60 APPLIED LIFE SCIENCES↗

Simulation and Experimental Validation of Electromagnetic Signatures for Monitoring of Nuclear Material Storage Containers

Previous research at the Pacific Northwest National Laboratory (PNNL) has demonstrated that the low frequency electromagnetic (EM) response of a sealed metallic container interrogated with an encircling coil is a strong function of its contents and can be used to form a distinct signature which can confirm the presence of specific components without revealing hidden geometry or classified design information. Finite element simulations have recently been performed to further investigate this response for a variety of configurations composed of an encircling coil and a typical nuclear material storage container. Excellent agreement was obtained between simulated and measured impedance signatures of electrically conducting spheres placed inside an AT-400R nuclear container. Simulations were used to determine the effects of excitation frequency and the geometry of the encircling coil, nuclear container, and internal contents. The results show that it is possible to use electromagnetic models to evaluate the application of the EM signature technique to proposed versions of nuclear weapons containers which can accommodate restrictions imposed by international arms control and treaty verification legislation.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Dry coupled magnetostrictive transducers for robotic inspection of dry storage casks - 15304

The lack of a national repository for used nuclear fuel has lead to the usage of dry storage casks as the de facto long term storage solution, the usage of which is prevalent throughout the United States. Furthermore, as shown in figure 3, the usage of dry storage is only expected to increase over time. Because these casks were originally intended as only an interim measure, there is an urgent need to develop methods to monitor their structural health over the long-term. Additionally, when concerns about the susceptibility of these casks to cracking is considered, the need for inspection becomes even more apparent. The use of robotic devices to inspect the interior of these casks for signs of damage has been proposed, but in order for this to be realized, advances in sensing technology must occur. We develop a novel type of transducer for non-destructive evaluation to aid in these efforts. We construct a prototype sensor, demonstrate simple defect detection with it, and present a design for an inspection robot equipping these transducers. Ultrasonic inspection is a well known method of non-destructive evaluation which works by measuring the response of ultrasonic waves propagating through a material. In through-transmission inspection, a transmitter and receiver are used to generate and detect waves in the material to be inspected. The presence of a crack or defect in the material will scatter some of the transmitted wave's energy, reducing the strength of the response at the receiver. Magnetostrictive transducers are often used to generate and detect guided waves. These transducers depend on the magnetostrictive effect, where certain materials will deform in the presence of a magnetic field. The typical construction of one of these transducers is shown in figure 5, consisting of a magnetostrictive foil, meandering coil, and a biasing magnet. Materials typically used for the foil include Fe-Co and Terfenol-D. For wave generation, a high-frequency alternating current is supplied to the coil of the transducer, which generates an oscillating magnetic field that causes the foil to deform. For reception, the inverse occurs: deformation of the foil results in a current in the coil that can be detected. The deformation of the foil is usually coupled to the material to be inspected with an adhesive, and waves are transmitted through this bond. Obviously, an inspection robot cannot have its sensors bound to the surface of the cask. A robot is being designed for inspection, and it must deal with many challenges inside the cask, including tight confines, right-angle transitions, high temperatures, and radiation. For our initial design, we consider only the geometrical constraints, and present a design for a prototype that can be assembled from COTS components. The robot needs to be articulated to navigate the bends in the cask, so each wheel is individually actuated. The robot is controlled via a tether, which also supplies electrical power and compressed air. For localization, ultrasonic range-finders and a camera are equipped. Using the basic transducer, we experimented with various configurations of materials and geometry. In order to gather relevant data, we used force sensitive resistors to measure applied force, and a Matec computer system to generate and measure ultrasonic waves. A testing rig was constructed to simulate the geometrical constraints of the interior of the cask, and we experimented using deadweights, a pneumatic cylinder, and an air bladder to apply the force. It was discovered early in the testing process that the performance of the transducer was very sensitive to the alignment of the components, and the method by which the foil was attached. To maximize performance, we designed an enclosure that would hold the components in alignment while still allowing the foil to float. To test the effectiveness of our new transducer, we cut circular holes of varying diameter in 2 mm aluminum plate, and measured the response across them. It can be seen that there is a clear relationship between the strength of the received signal and the force applied, and to a lesser extent, the size of the defect. This design performs adequately as a proof of concept, and a more precisely fabricated enclosure should further increase the accuracy of its measurements.

42 ENGINEERING↗

High slot utilization systems for electric machines

Two new High Slot Utilization (HSU) Systems for electric machines enable the use of form wound coils that have the highest fill factor and the best use of magnetic materials. The epoxy/resin/curing treatment ensures the mechanical strength of the assembly of teeth, core, and coils. In addition, the first HSU system allows the coil layers to be moved inside the slots for the assembly purpose. The second system uses the slided-in teeth instead of the plugged-in teeth. The power density of the electric machine that uses either system can reach its highest limit.

42 ENGINEERING↗

Multilayer radiation shield

A power generation system including: a generator including a rotor including a superconductive rotor coil coupled to a rotatable shaft; a first prime mover drivingly coupled to the rotatable shaft; and a thermal radiation shield, partially surrounding the rotor coil, including at least a first sheet and a second sheet spaced apart from the first sheet by centripetal force produced by the rotatable shaft. A thermal radiation shield for a generator including a rotor including a super-conductive rotor coil including: a first sheet having at least one surface formed from a low emissivity material; and at least one additional sheet having at least one surface formed from a low emissivity material spaced apart from the first sheet by centripetal force produced by the rotatable shaft, wherein each successive sheet is an incrementally greater circumferential arc length and wherein the centripetal force shapes the sheets into a substantially catenary shape.

42 ENGINEERING↗