Creep-fatigue analysis by strain-range partitioning.

The framework of a new method is outlined for treating creep-fatigue behavior of metals. Inelastic strain-ranges are partitioned into the components of (1) completely reversed plasticity, (2) tensile plasticity reversed by compressive creep, or tensile creep reversed by compressive plasticity, and (3) completely reversed creep. Each of these components is shown to be related to cyclic life by a Manson-Coffin type power-law equation. A linear life fraction rule is used to combine the damaging effects of the individual components enabling the prediction of life. Test results are presented for a 2.25 Cr-1 Mo steel as well as limited information for a Type 316 stainless steel.

Manson, S. S.↗

Analysis of RAE-B attitude data

Attempts made to obtain a description of the in-orbit dynamic behavior of the RAE-B spacecraft and account for the discrepancies between predicted and actual in-orbit performance are reported. In particular, attitude dynamics during the final despin operations in lunar orbit, throughout all deployment operations, and into the final steady state mission mode were investigated. Attempts made to match computer simulation results to the observed equilibrium data are discussed. Due to a damaged antenna boom and the unavailability of sufficient attitude and dynamics data, most of the objectives were not realized.

Hedland, D. A.↗

Electron-Diffraction Analysis of Growth of GaAs

Report describes experiments that used reflection high-energy-electron diffraction (RHEED) to investigate behavior of GaAs surfaces during and after growth by molecular-beam epitaxy (MBE). Experimental results show dynamic RHEED measurements useful both as probes of surface and growth kinetics and as methods for determining and reproducing surface and growth conditions.

Lewis, B. F.↗

Spectral behavior of Hercules X-1 - Its long-term variability and pulse phase spectroscopy

Results are presented of the analysis of the broad-energy-band Her X-1 spectra obtained by HEAO 1. Data from 13 pointed observations covered three 35-day cycles in February, August, and September of 1978. The pulse phase-averaged spectrum did not show any apparent variation during the main-on state, except for the overall intensity. The pulse phase-resolved spectrum, on the other hand, showed a moderately strong phase dependence in each of the main-on state pointings. This may imply that the orientation of the emission region is not changing on a monthly time frame, but the geometry of that region may evolve with time.

Soong, Y.↗

Program For Analysis Of Metal-Matrix Composites

METCAN (METal matrix Composite ANalyzer) is computer program used to simulate computationally nonlinear behavior of high-temperature metal-matrix composite structural components in specific applications, providing comprehensive analyses of thermal and mechanical performances. Written in FORTRAN 77.

Murthy, P. L. N.↗

Frequency domain analysis of the random loading of cracked panels

The primary effort concerned the development of analytical methods for the accurate prediction of the effect of random loading on a panel with a crack. Of particular concern was the influence of frequency on the stress intensity factor behavior. Many modern structures, such as those found in advanced aircraft, are lightweight and susceptible to critical vibrations, and consequently dynamic response plays a very important role in their analysis. The presence of flaws and cracks can have catastrophic consequences. The stress intensity factor, K, emerges as a very significant parameter that characterizes the crack behavior. In analyzing the dynamic response of panels that contain cracks, the finite element method is used, but because this type of problem is inherently computationally intensive, a number of ways of calculating K more efficiently are explored.

Doyle, James F.↗

The Cepheid mode problem

The modal behavior of RR Lyrae stars and low mass Cepheids has been investigated using a nonlinear relaxation technique and stability analysis. The advantages of this type of numerical approach in investigations of preferred mode of pulsation are discussed. The results obtained for both classes of variable stars are quite similar: first harmonic pulsation toward the blue, fundamental pulsation toward the red, and mixed-mode behavior at the extreme red edge of the instability strip. In addition, stars near the center of the strip can pulsate in either the fundamental or the first harmonic mode. Possible implications for observational results, including the Oosterhoff dichotomy of globular clusters and the beat Cepheids, are discussed.

Stellingwerf, R. F.↗

Test Bed for Investigating Anomalous Pump Behavior in a Single Phase Mechanically Pumped Flow Loop and Lessons Learned

NASA’s Europa Clipper mission is tasked with investigating the habitability of this icy moon of Jupiter and determining if it is capable of supporting life. The suite of powerful instruments necessary for this mission, combined with the harsh environment, require an elaborate single phase, mechanically pumped flow loop (MPFL) to redistribute waste heat around the spacecraft, thus minimizing energy requirements and avoiding the need for constant heating of the propulsion tanks. At the heart of this MPFL is a pump which will circulate fluid for the entirety of the 12-year mission; however, during initial qualification testing, anomalous behavior raised serious concerns regarding the pump and system design. Due to the critical nature of the pump, a major investigation was launched to evaluate the pump, system design, and the testing methodology employed to investigate this anomaly. This investigation resulted in a highly detailed analysis of the test loop, revised procedures, and the isolation/removal of variables impacting the quality of the observed pump behavior. The resulting test loop permitted comprehensive monitoring of the pump in the MPFL, including: flow rate, inlet and outlet static pressures, temperature, power consumption, and pump speed. Additionally, the investigation of the anomaly revealed several key lessons learned and helped institute a new set of best practices for future MPFL tests.

Miers, Collier↗

Cardiovascular responses of snakes to hypergravity

Snakes have provided useful vertebrate models for understanding circulatory adaptation to gravity, attributable to their elongate body shape and evolutionary diversificaton in terms of ecology and behavior. Recently we have studied cardiovascular responses of snakes to hypergravic acceleration forces produced acutely in the head-to-tail direction (+Gz) on a short-arm centrifuge. Snakes were held in a nearly straight position within a horizontal plastic tube and subjected to a linear force gradient during acceleration. Carotid blood flow provided an integrated measure of cardiovascular performance. Thus, cardiovascular tolerance of snakes to stepwise increments of Gz was measured as the caudal Gz force at which carotid blood flow ceased. Tolerance to increasing Gz varies according to adaptive evolutionary history inferred from the ecology and behavior of species. With respect to data for six species we investigated, multiple regression analysis demonstrates that Gz tolerance correlates with gravitational habitat, independently of body length. Relative to aquatic and non-climbing species, carotid blood flow is better maintained in arboreal or scansorial species, which tolerate hypergravic forces of +2 to +3.5 Gz. Additionally, semi-arboreal rat snakes (Elaphe obsoleta) exhibit plasticity of responses to long-term, intermittent +1.5 Gz stress. Compared to non-acclimated controls, acclimated snakes show greater increases of heart rate during head-up tilt or acceleration, greater sensitivity of arterial pressure to circulating catecholamines, higher blood levels of prostaglandin ratios favorable to maintenance of arterial blood pressure, and medial hypertrophy in major arteries and veins. As in other vertebrates, Gz tolerance of snakes is enhanced by acclimation, high arterial pressure, comparatively large blood volume, and body movements. Vascular studies of snakes suggest the importance to acclimation of local responses involving vascular tissue, in addition to centrally mediated responses to fluid shifts.

Review, Tutorial↗

Implementation of J-A Methodology Elastic-Plastic Crack Instability Analysis Capability into the WARP-3D Code

Characterization of the near crack-tip stress/strain fields is the foundation of fracture mechanics. The description of the near tip stress field and the prediction of when fracture occurs is well established for brittle materials that exhibit linear elastic behavior. However, in ductile materials or conditions that violate linear elastic assumptions (Aluminum alloys, Al 2024-T3, Al 2024- T351 etc.), the elastic-plastic crack-tip stress fields are characterized by the Hutchison-Rice-Rosengren (HRR) field. The J-integral is commonly used to characterize amplitude of the HRR field under elastic-plastic conditions. The J-integral has been demonstrated for crack-tip fields that are under high constraint conditions (i.e., small-scale plasticity where the J-dominance is maintained). However, as the external load increases, yielding changes from small- to largescale plasticity and usually a loss of constraint (i.e., reduction in the triaxial stress field along the crack front). The loss of constraint leads to the deviation of the crack-tip stress fields from that given by the HRR field. Hence, the J-dominance will be gradually lost and additional parameter(s) are required to quantify the crack-tip stress fields and predict fracture behavior. The assessment objectives were to: 1) implement a two-parameter (i.e., J-A) fracture criterion into an elastic-plastic three-dimensional (3D) finite element analysis (FEA), 2) validate the implementation by comparison with the A parameter from literature data, 3) conduct material characterization tests to quantify the material behavior and provide fracture data for validation of the J-A fracture criteria, and (4) perform evaluations to establish if the J-A criteria can be used to predict fracture in a ductile metallic material (e.g., aluminum alloys). The A parameter in these criteria is the second parameter in a three-term elastic-plastic asymptotic expansion of the neartip stress behavior. A series of extensive FEAs were performed using WARP3D software package to obtain solutions for the A parameter for different specimen configurations. The methodology needed for the estimation of the A parameter in the asymptotic expansion was developed and implemented using Matlab®. A user material (UMAT) routine was used to model the material stress-strain response using a Ramberg-Osgood power law with a hardening exponent (n) and a material coefficient (alpha). This UMAT routine was successfully implemented in WARP3D software and validated through comparison with the experimental data. Three configurations were extracted from published results: 1) center cracked plate (CCP), 2) single edge-cracked plate (SECP), and 3) double edge-cracked plate (DECP). These configurations and four other configurations (three-hole tension (THT)), three-point bend (3PTB), three-hole compact tension (3PCT), and compact tension (CT)) were analyzed to verify the methodology that was developed and implemented into WARP3D. Solutions of the A parameter were obtained for remote tension loading conditions that started with small-scale yielding and continued into the large-scale plasticity regime. The results indicate that the methodology developed can be used to calculate the elastic-plastic J-A parameters for test specimens with a range of crack geometries, material strain hardening behaviors, and loading conditions. The J-A parameters were implemented as fracture criteria and used to predict the test results. For comparison, other fracture criteria were used to predict the same test results. Major findings include: The A constraint parameter A varies with specimen type and applied load thus accurate determination is crucial in predicting the failure load, and the A parameter is asymptotic as the failure load is approached, making an accurate determination difficult (i.e., small differences in the A parameter can cause large variations in failure load) for materials exhibiting elastic-plastic behavior. The failure predictions from J-A methodology were more accurate than the traditionally used KC and J methods, and have comparable scatter to that observed when using the crack-tip opening angle (CTOA) method. However, the J-A methodology requires considerable effort (expertise level and labor) to implement and to evaluate the A parameter for different specimen types and materials, or to apply this methodology to part-through crack (e.g., 3D problems) structural applications.

Hamm, Kenneth R., Jr.↗

Discrete time domain modelling and analysis of dc-dc converters with continuous and discontinuous inductor current

Using discrete time state variable representation, a generalized computer-aided modeling and analysis of dc-dc converters is presented. The methodology provides exact modeling and is applicable to all types of power stages and duty-cycle control, including continuous and discontinuous inductor current operation. Converter stability, transient behavior and audio susceptibility can be analytically evaluated and predicted. The generalized theory of the proposed approach to converter modeling and analysis is presented first, followed by a demonstrative example applying the theory to a constant frequency buck converter operating in continuous and discontinuous inductor current mode. Excellent agreement with laboratory test data has been observed.

Iwens, R. P.↗

Vascular mechanics of the coronary artery

This paper describes our research into the vascular mechanics of the coronary artery and plaque. The three sections describe the determination of arterial mechanical properties using intravascular ultrasound (IVUS), a constitutive relation for the arterial wall, and finite element method (FEM) models of the arterial wall and atheroma. METHODS: Inflation testing of porcine left anterior descending coronary arteries was conducted. The changes in the vessel geometry were monitored using IVUS, and intracoronary pressure was recorded using a pressure transducer. The creep and quasistatic stress/strain responses were determined. A Standard Linear Solid (SLS) was modified to reproduce the non-linear elastic behavior of the arterial wall. This Standard Non-linear Solid (SNS) was implemented into an axisymetric thick-walled cylinder numerical model. Finite element analysis models were created for five age groups and four levels of stenosis using the Pathobiological Determinants of Atherosclerosis Youth (PDAY) database. RESULTS: The arteries exhibited non-linear elastic behavior. The total tissue creep strain was epsilon creep = 0.082 +/- 0.018 mm/mm. The numerical model could reproduce both the non-linearity of the porcine data and time dependent behavior of the arterial wall found in the literature with a correlation coefficient of 0.985. Increasing age had a strong positive correlation with the shoulder stress level, (r = 0.95). The 30% stenosis had the highest shoulder stress due to the combination of a fully formed lipid pool and a thin cap. CONCLUSIONS: Studying the solid mechanics of the arterial wall and the atheroma provide important insights into the mechanisms involved in plaque rupture.

NASA Program Biomedical Research and Countermeasur↗

Thermal behavior spiral bevel gears

An experimental and analytical study of the thermal behavior of spiral bevel gears is presented. Experimental data were taken using thermocoupled test hardware and an infrared microscope. Many operational parameters were varied to investigate their effects on the thermal behavior. The data taken were also used to validate the boundary conditions applied to the analytical model. A finite element-based solution sequence was developed. The three-dimensional model was developed based on the manufacturing process for these gears. Contact between the meshing gears was found using tooth contact analysis to describe the location, curvatures, orientations, and surface velocities. This information was then used in a three-dimensional Hertzian contact analysis to predict contact ellipse size and maximum pressure. From these results, an estimate of the heat flux magnitude and the location on the finite element model was made. The finite element model used time-averaged boundary conditions to permit the solution to attain steady state in a computationally efficient manner.Then time- and position-varying boundary conditions were applied to the model to analyze the cyclic heating and cooling due to the gears meshing and transferring heat to the surroundings, respectively. The model was run in this mode until the temperature behavior stabilized. The transient flash temperature on the surface was therefore described. The analysis can be used to predict the overall expected thermal behavior of spiral bevel gears. The experimental and analytical results were compared for this study and also with a limited number of other studies. The experimental and analytical results attained in the current study were basically within 10% of each other for the cases compared. The experimental comparison was for bulk thermocouple locations and data taken with an infrared microscope. The results of a limited number of other studies were compared with those obtained herein and predicted the same basic behavior.

Handschuh, Robert F.↗

A plasma-based non-intrusive point source for acoustic beamforming applications

A laser-generated plasma acoustic point source is used to directly measure the point spread function (PSF) of a microphone phased array. In beamforming analysis of microphone phased array data, the true acoustic field is convolved with the array's PSF. By directly measuring the PSF, corrections to the array analysis can be computed and applied. The acoustic source is measured in an open-jet aeroacoustic facility to evaluate the effects of sampling rate, microphone installation, source shift, reflections, shear layer refraction and model presence. Results show that measurements exhibit behavior consistent with theory with regard to source shift and shear layer refraction. Application of a measured PSF in beamforming analysis shows the process provides an effective in-situ method for array calibration both with and without flow and allows for corrections to incorporate reflections and scattering. The technique improves the agreement of beamforming results with the true spectrum of a known source, especially in the presence of reflections.

phased array↗

Bolt Analysis Program

In designing and testing bolted joints there are multiple parameters to be considered and calculations that must be performed to predict the joint behavior. Each different set of parameters may call for a different set of equations. Determining every parameter in each bolted joint is impractical and in many cases impossible. On the other hand, it is much easier to reduce these calculations to a universal set that can be used for all bolted joints. This is the purpose of the Bolt Analysis Program. My project under the Mechanical and Rotating Systems branch of the Engineering Development and Analysis Division was to take the Bolt Analysis Program Version 2.0 and update the program to a modem and user-friendly format. Version 2.0 of the Bolt Analysis Program is a useful program, but lacks the dynamic capabilities that are needed for current applications. Version 2.0 of the Bolt Analysis Program was written in 1993 using the Pascal programming language in a DOS format. This program allows you to input data in a step-by-step format, calculates the data, and then on a final screen displays the input and the output fiom the calculations. Version 2.0 is still applicable for all bolted joint anaiysis, but has updates that are desired. First, the program runs in DOS format. With the applications available today, my mentor decided it would be best to update the program into Excel using Visual Basic for Applications (VBA). This would allow the program to have multiple Graphical User Interfaces (GUI s) while retaining all functions of the previous program. Version 2.0 only allows you to input data in a step-by-step process. If you make a mistake and need to go back, you must run through the entire program before you can return to fix your error. This becomes tedious when needing to change one parameter or test multiple sets of data. In Version 3.0, the program allows you to enter and change data at any time while displaying real-time output data. If you realize an error, it is as simple as scrolling back to your mistake and changing the data. Additional information is included in the original extended abstract.

Travis, Brandon E.↗

Open Science for Life in Space: Data Sharing and Tools for Knowledge Discovery

The next era in human space exploration is rapidly approaching and will require the use of countermeasures to deep space health hazards. The development of countermeasures (or, there-purposing of existing agents) will be highly dependent on our understanding of basic biological responses to space stressors (e.g. ionizing radiation, altered gravitational fields, altered day-night cycles, confinement, isolation, hostile-closed environments, distance-duration from Earth, exposure to celestial regolith, etc.). The fast-growing array of space biological data, which in the past was simply archived after minimal analysis, holds great potential if it can be reorganized and formatted for Open Science. Organizing the data for such analysis is a challenge because of its diverse nature (molecular, cellular, tissue, imaging, whole organism and behavior). We will discuss here several strategies that NASA's Biological and Physical Science Division has put in place to maximize the return on investment for spaceflight bioscience data. Open Science, as a scientific philosophy, is the concept that the more people who have access to the data, the more knowledge will be gained from it. This guiding principle led NASA to develop GeneLab in 2015. GeneLab houses spaceflight and relevant ground-based multi-omics data, and has grown to ~400 transcriptomatic, proteomic, metabolomic and epigenomic datasets from plant, rodent, small animal, and microbial space experiments. GeneLab provides users with various tools for data analysis and a visualization portal that allows users to interact with gene expression data from space-related 'omics experiments. Open Science is also about building scientific communities, and with this spirit in mind, GeneLab has spawned several Analysis Working Groups (AWGs), comprised of more than 200 volunteer scientists. The AWGs initially provided feedback on the processing pipeline and metadata 'omics standards for GeneLab. Over the last few years, they have become a community-driven science enterprise, engaging in large meta-analysis of GeneLab datasets, resulting in 10 publications (beyond the originally submitted research). Overall, the Open Science nature of GeneLab has resulted in a high degree of data-use, resulting in 40 enabled publications by open data. The enormous success and knowledge gained from GeneLab has led to a collection of sister NASA "Open Science Data Repositories (OSDR)" and research support groups. These include the NASA Ames Life Sciences Data Archive (ALSDA), the NASA Biological Institutional Scientific Collection (NBISC), and the Biospecimen Sharing Program (BSP). All are adopting the GeneLab data architecture system to maximize open-access, find-ability, accessibility, interoperability, and reusability (FAIR). ALSDA collects and curates phenotypic-physiological bioimaging-behavioral data from space and space-relevant non-human experiments, oftentimes coming from the same omics-associated experimental datasets found in GeneLab. Since 2021, a community of ~100 researchers have rallied around ALSDA, to provide feedback in a new ALSDA AWG focused on phenotypic-physiological investigation-sample-assay metadata standards (e.g., Micro-Computed Tomography, Light/Flourescence Microscopy, Western Blot, Flow Cytometry, Novel Object Recognition, Elevated Plus Maze, etc. of ~50 assays collected). These standards are part of a new single point-of-entry data submission portal for all non-human Space Biology and Human Research Program principal investigators, to submit, curate, and share their research data. With open-access space biological data now collected and curated together with rich metadata, and with the potential for linkage to "big data" from the international biological and medical communities (NIH, EBI, etc.), the artificial intelligence and machine learning (AI/ML) era has started for Space Biology.

omics↗

Plasticity - Theory and finite element applications.

A unified presentation is given of the development and distinctions associated with various incremental solution procedures used to solve the equations governing the nonlinear behavior of structures, and this is discussed within the framework of the finite-element method. Although the primary emphasis here is on material nonlinearities, consideration is also given to geometric nonlinearities acting separately or in combination with nonlinear material behavior. The methods discussed here are applicable to a broad spectrum of structures, ranging from simple beams to general three-dimensional bodies. The finite-element analysis methods for material nonlinearity are general in the sense that any of the available plasticity theories can be incorporated to treat strain hardening or ideally plastic behavior.

Armen, H., Jr.↗