Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “BEAM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,405 records · Page 78

Extension of Ko Straight-Beam Displacement Theory to Deformed Shape Predictions of Slender Curved Structures

The Ko displacement theory originally developed for shape predictions of straight beams is extended to shape predictions of curved beams. The surface strains needed for shape predictions were analytically generated from finite-element nodal stress outputs. With the aid of finite-element displacement outputs, mathematical functional forms for curvature-effect correction terms are established and incorporated into straight-beam deflection equations for shape predictions of both cantilever and two-point supported curved beams. The newly established deflection equations for cantilever curved beams could provide quite accurate shape predictions for different cantilever curved beams, including the quarter-circle cantilever beam. Furthermore, the newly formulated deflection equations for two-point supported curved beams could provide accurate shape predictions for a range of two-point supported curved beams, including the full-circular ring. Accuracy of the newly developed curved-beam deflection equations is validated through shape prediction analysis of curved beams embedded in the windward shallow spherical shell of a generic crew exploration vehicle. A single-point collocation method for optimization of shape predictions is discussed in detail

Ko, William L.↗

Beam Tests of the PIP-II Injector Test Radio Frequency Quadrupole

In modern high intensity ion-particle accelerators, a Radio Frequency Quadrupole (RFQ) is utilized to prepare a high-quality beam for injection to the main accelerating section. Since an RFQ governs the initial beam parameters, characterization of the beam coming out from the RFQ is foremost step toward commissioning of an accelerator facili-ty. It allows validating the RFQ design as well as attaining a better understanding of charged-particle beams. This pa-per describes the beam-performance of the Proton Improvement Plan-II Injector Test (PIP2IT) Continuous Wave (CW) four vane-type RFQ. It is designed to operate at a frequency of 162.5 MHz and accelerate a nominal H- beam of 5 mA from 30 keV to 2.1 MeV. The paper details beam tests performed to validate the RFQ design specifications for trans-mission, beam kinetic energy and, RMS emittances. The paper also presents beam profile measurements and implica-tion of the beam-jitters on the effective beam emittance at the RFQ exit.

43 PARTICLE ACCELERATORS↗

Space Charge Effects in Low Energy Magnetized Electron Beams

Magnetized electron cooling of the ion beam is one of the major approaches towards obtaining the required high luminosity in the proposed Electron-Ion Collider (EIC). To increase the cooling efficiency, a bunched electron beam with a high bunch charge and high repetition rate is required. However, these features can combine to enhance the collective interactions, such as the space charge effect. A magnetized electron beam was successfully generated at the Thomas Jefferson National Accelerator Facility (JLab) using a compact, 300 kV DC high voltage photo-gun with an inverted insulator geometry and bi-alkali antimonide photocathode. The beam magnetization was characterized using a modest diagnostic beamline to measure beam sizes, rotation angles, and normalized transverse emittance as a function of magnetic field at the photocathode, laser spot size, and gun high-voltage. Simultaneously, simulations were performed using the A Space Charge Tracking Algorithm (ASTRA) and General Particle Tracer (GPT) programs. Further, sustained high average current magnetized beam up to 28 mA was demonstrated, and the photocathode lifetime for different magnetized electron beam currents was investigated. In the second part of the project, the space charge effect in low-energy magnetized electron beams was studied and compared with GPT simulations. The high bunch charge studies showed evidence of space charge current limitations starting at 0.3 nC and limited the maximum delivered bunch charge to 0.7 nC. To reach the high bunch charge goal of a few nC, the existing DC photo-gun design was modified using CST Studio Suite’s electromagnetic field solver, and a way to cancel the beam deflection exerted by the non-symmetric nature of the inverted insulator photo-gun geometry was discovered. This thesis presents a detailed description of the generation, characterization, and simulation of high current, high bunch charge magnetized electron beams at JLab, as well as the modified photo-gun design. Together with measurements and simulations, the purpose of this thesis is to provide a solid background on the theoretical aspects and the experimental challenges associated with magnetized electron beams for accelerator applications.

Wijethunga, W M Sajini↗

CoSyR: A novel beam dynamics code for the modeling of synchrotron radiation effects

The self-consistent nonlinear dynamics of a relativistic charged particle beam interacting with its complete self-fields is a fundamental problem underpinning many of the accelerator design issues in high brightness beam applications, as well as the development of advanced accelerators. Particularly, synchrotron radiation induced effects in a magnetic dispersive beamline element can lead to collective beam instabilities and emittance growth. A novel beam dynamics code is developed based on a Lagrangian method for the calculation of the particles’ radiation near-fields using wavefront/wavelet meshes via the Green’s function of the Maxwell equations. These fields are then interpolated onto a moving mesh for dynamic update of the beam. This method allows radiation co-propagation and self-consistent interaction with the beam in 2D/3D simulations at greatly reduced numerical errors. Multiple levels of parallelisms are inherent in this method and implemented in our code CoSyR to enable at-scale simulations of nonlinear beam dynamics on modern computing platforms using MPI, multi-threading, and GPUs. Here, the current 2D implementation of CoSyR has been used to evaluate the transverse and longitudinal coherent radiation effects on the beam and to investigate beam optics designs proposed for mitigation of beam brightness degradation in a magnetic bunch compressor. In this paper, the design of CoSyR, as well as the benchmark with other coherent synchrotron radiation models, are described and discussed. Extension of the core algorithms to 3D is possible and planned.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Expanded beam deflection method for simultaneous measurement of displacement and vibrations of multiple microcantilevers

Here we present an extension of optical beam deflection (OBD) method for measuring displacement and vibrations of an array of microcantilevers. Instead of focusing on the cantilever, the optical beam is either focused above or below the cantilever array, or focused only in the axis parallel to the cantilevers length, allowing a wide optical line to span multiple cantilevers in the array. Each cantilever reflects a part of the incident beam, which is then directed onto a photodiode array detector in a manner allowing distinguishing between individual beams. Each part of reflected beam behaves like a single beam of roughly the same divergence angle in the bending sensing axis as the incident beam. Since sensitivity of the OBD method depends on the divergence angle of deflected beam, high sensitivity is preserved in proposed expanded beam deflection (EBD) method. At the detector, each spot's position is measured at the same time, without time multiplexing of light sources. This provides real simultaneous readout of entire array, unavailable in most of competitive methods, and thus increases time resolution of the measurement. Expanded beam can also span another line of cantilevers allowing monitoring of specially designed two-dimensional arrays. In this paper, we present first results of application of EBD method to cantilever sensors. We show how thermal noise resolution can be easily achieved and combined with thermal noise based resonance frequency measurement.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The effect of electron beam pitch angle and density gradient on solar type III radio bursts

1.5D particle-in-cell simulations of a hot, low density electron beam injected into magnetized, maxwellian plasma were used to further explore the alternative non-gyrotropic beam driven electromagnetic (EM) emission mechanism, first studied in Tsiklauri, Phys. Plasmas 18, 052903 (2011). Variation of beam injection angle and background density gradient showed that the emission process is caused by the perpendicular component of the beam injection current, whereas the parallel component only produces Langmuir waves, which play no role in the generation of EM waves in our mechanism. Particular emphasis was put on the case, where the beam is injected perpendicularly to the background magnetic field, as this turned off any electrostatic wave generation along the field and left a purely electromagnetic signal in the perpendicular components. The simulations establish the following key findings: (i) Initially, waves at a few {omega}{sub ce}/{gamma} are excited, mode converted and emitted at Almost-Equal-To {omega}{sub pe} (ii) The emission intensity along the beam axis is proportional to the respective component of the kinetic energy of the beam; (iii) The frequency of the escaping EM emission is independent of the injection angle; (iv) A stronger background density gradient causes earlier emission; (v) The beam electron distribution function in phase space shows harmonic oscillation in the perpendicular components at the relativistic gyrofrequency; (vi) The requirement for cyclotron maser emission, ({partial_derivative}f/{partial_derivative}v{sub Up-Tack })>0, is fulfilled; (vii) The degree of linear polarization of the emission is strongly dependent on the beam injection angle; (viii) The generated electromagnetic emission is left-hand elliptically polarized as the pitch angle tends to 90 Degree-Sign ; and (ix) The generated electromagnetic energy is of the order of 0.1% of the initial beam kinetic energy.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

An overview of the facilities, activities, and developments at the University of North Texas Ion Beam Modification and Analysis Laboratory (IBMAL)

The Ion Beam Modification and Analysis Laboratory (IBMAL) at the University of North Texas includes several accelerator facilities with capabilities of producing a variety of ion beams from tens of keV to several MeV in energy. The four accelerators are used for research, graduate and undergraduate education, and industrial applications. The NEC 3MV Pelletron tandem accelerator has three ion sources for negative ions: He Alphatross and two different SNICS-type sputter ion sources. Presently, the tandem accelerator has four high-energy beam transport lines and one low-energy beam transport line directly taken from the negative ion sources for different research experiments. For the low-energy beam line, the ion energy can be varied from {approx}20 to 80 keV for ion implantation/modification of materials. The four post-acceleration beam lines include a heavy-ion nuclear microprobe; multi-purpose PIXE, RBS, ERD, NRA, and broad-beam single-event upset; high-energy ion implantation line; and trace-element accelerator mass spectrometry. The NEC 3MV single-ended Pelletron accelerator has an RF ion source mainly for hydrogen, helium and heavier inert gases. We recently installed a capacitive liner to the terminal potential stabilization system for high terminal voltage stability and high-resolution microprobe analysis. The accelerator serves a beam line for standard RBS and RBS/C. Another beamline for high energy focused ion beam application using a magnetic quadrupole lens system is currently under construction. This beam line will also serve for developmental work on an electrostatic lens system. The third accelerator is a 200 kV Cockcroft-Walton accelerator with an RF ion source. The fourth accelerator is a 2.5 MV Van de Graaff accelerator, which was in operation for last several decades is currently planned to be used mainly for educational purpose. Research projects that will be briefly discussed include materials synthesis/modification for photonic, electronic, and magnetic applications, surface sputtering and micro-fabrication of materials, development of high-energy ion microprobe systems, and educational and outreach activities.

43 PARTICLE ACCELERATORS↗

Study of beam loading and its compensation in the Compact Ultrafast Terahertz Free-Electron Laser injector linac

The RF properties of an accelerating structure, and the pulse structure and charge per bunch in the electron beam propagating through it are important parameters that determine the impact of beam loading in the structure. The injector linac of the Compact Ultrafast Terahertz Free-Electron Laser (CUTE-FEL) has been operated with two different pulse structures during initial commissioning experiments and the effect of beam loading on the accelerated electron beam parameters has been studied analytically for these two pulse structures. This paper discusses the analytical study of beam loading in a Standing Wave, Plane Wave Transformer linac employed in the CUTE-FEL setup, and a possible technique for its compensation for the electron beam parameters of the CUTE-FEL. A parametric study has been performed to study beam loading for different beam currents and to optimize injection time of the electron beam to compensate beam loading. Results from the parametric study have also been used to explain previously observed results from acceleration experiments in the CUTE-FEL setup.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A multiple gap plasma cathode electron gun and its electron beam analysis in self and trigger breakdown modes

In the present paper, a pseudospark discharge based multiple gap plasma cathode electron gun is reported which has been operated separately in self and trigger breakdown modes using two different gases, namely, argon and hydrogen. The beam current and beam energy have been analyzed using a concentric ring diagnostic arrangement. Two distinct electron beams are clearly seen with hollow cathode and conductive phases. The hollow cathode phase has been observed for ∼50 ns where the obtained electron beam is having low beam current density and high energy. While in conductive phase it is high current density and low energy electron beam. It is inferred that in the hollow cathode phase the beam energy is more for the self breakdown case whereas the current density is more for the trigger breakdown case. The tailor made operation of the hollow cathode phase electron beam can play an important role in microwave generation. Up to 30% variation in the electron beam energy has been achieved keeping the same gas and by varying the breakdown mode operations. Also, up to 32% variation in the beam current density has been achieved for the trigger breakdown mode at optimized trigger position by varying the gas type.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Study of a high power hydrogen beam diagnostic based on secondary electron emission

In high power neutral beams for fusion, beam uniformity is an important figure of merit. Knowing the transverse power profile is essential during the initial phases of beam source operation, such as those expected for the ITER heating neutral beam (HNB) test facility. To measure it a diagnostic technique is proposed, based on the collection of secondary electrons generated by beam-surface and beam-gas interactions, by an array of positively biased collectors placed behind the calorimeter tubes. This measurement showed in the IREK test stand good proportionality to the primary beam current. To investigate the diagnostic performances in different conditions, we developed a numerical model of secondary electron emission, induced by beam particle impact on the copper tubes, and reproducing the cascade of secondary emission caused by successive electron impacts. The model is first validated against IREK measurements. It is then applied to the HNB case, to assess the locality of the measurement, the proportionality to the beam current density, and the influence of beam plasma.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Excitation of kinetic Alfvén waves by fast electron beams

Energetic electron beams, which are ubiquitous in a large variety of active phenomena in space and astrophysical plasmas, are one of the most important sources that drive plasma instabilities. In this paper, taking account of the return-current effect of fast electron beams, kinetic Alfvén wave (KAW) instability driven by a fast electron beam is investigated in a finite-β plasma of Q < β < 1 (where β is the kinetic-to-magnetic pressure ratio and Q ≡ m{sub e} /m{sub i} is the mass ratio of electrons to ions). The results show that the kinetic resonant interaction of beam electrons is the driving source for KAW instability, unlike the case driven by a fast ion beam, where both the kinetic resonant interaction of beam ions and the return-current are the driving source for the KAW instability. KAW instability has a nonzero growth rate in the range of the perpendicular wave number, 0<k{sub ⊥}<k{sub ⊥}{sup u}, and the maximum growth rate, γ {sup m}, occurs between 0.5k{sub ⊥}{sup u}<k{sub ⊥}{sup m}<0.8k{sub ⊥}{sup u}. Both the maximal growing perpendicular wave number k{sub ⊥}{sup m} and the maximal growth rate γ {sup m} depend sensitively on the velocity of electron beam v{sub b} , and the most favorable beam velocity occurs between 8v{sub A} < v{sub b} < 10v{sub A} . On the other hand, the excited KAWs are weakly dispersive with k ρ {sub i} < 1 and have the maximum growth rate at relatively low perpendicular wave numbers in the range 0.3<k{sub ⊥}{sup m}ρ{sub i}<0.6 for a beam velocity v{sub b} < 10v{sub A} . A possible application to the upward electron beams in the terrestrial magnetosphere is briefly discussed.

79 ASTRONOMY AND ASTROPHYSICS↗

Unified Beam Control System of J-PARC Linac

A beam control system has been developed for the J-PARC linac to achieve strict design goals of beam performance and beam loss suppression in the high-intensity beams. An emerging concept of unified beam control has been adopted in the system, where a unified data source, standardized control units, a unified online model, and uniform high-level application frameworks have been designed and implemented. For precise beam controls, various beam tuning algorithms have been developed and tested. Design goals of beam performance, beam stability, and beam loss suppression have been achieved in the linac.

43 PARTICLE ACCELERATORS↗

Can volumetric modulated arc therapy with flattening filter free beams play a role in stereotactic body radiotherapy for liver lesions? A volume-based analysis

Purpose: To compare volumetric modulated arc therapy with flattening filter free (FFF) and flattening filter (FF) beams in patients with hepatic metastases subject to hypofractionated radiotherapy (RT). Methods: A planning study on 13 virtual lesions of increasing volume was performed. Two single arc plans were optimized with the RapidArc technique using either FFF or FF beams. A second planning study was performed on ten patients treated for liver metastases to validate conclusions. In all cases, a dose of 75 Gy in 3 fractions was prescribed to the planning target volume (PTV) and plans were evaluated in terms of coverage, homogeneity, conformity, mean dose to healthy liver and to healthy tissue. For each parameter, results were expressed in relative terms as the percentage ratio between FFF and FF data. Results: In terms of PTV coverage, conformity index favored FFF for targets of intermediate size while FF resulted more suitable for small (<100 cm{sup 3}) and large (>300 cm{sup 3}) targets. Plans optimized with FFF beams resulted in increased sparing of healthy tissue in {approx_equal}85% of cases. Despite the qualitative results, no statistically significant differences were found between FFF and FF results. Plans optimized with un-flattened beams resulted in higher average MU/Gy than plans with FF beams. A remarkable and significant difference was observed in the beam-on time (BOT) needed to deliver plans. The BOT for FF plans was 8.2 {+-} 1.0 min; for FFF plans BOT was 2.2 {+-} 0.2 min. Conclusions: RapidArc plans optimized using FFF were dosimetrically equivalent to those optimized using FF beams, showing the feasibility of SBRT treatments with FFF beams. Some improvement in healthy tissue sparing was observed when using the FFF modality due to the different beam's profile. The main advantage was a considerable reduction of beam-on time, relevant for SBRT techniques.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

MO-AB-BRA-07: Prompt Gamma-Ray Spectroscopy for Range Verification of Clinical Proton Beams

Purpose: We developed a pre-clinical prototype system for range verification of proton pencil-beam scanning fields. The system was evaluated using phantom treatment plans delivered with a clinical dose rate. Methods: The absolute range of proton pencil-beams was verified through an optimization procedure, which matches energy- and time-resolved prompt gamma-ray measurements with models, based on cross sections for discrete prompt gamma-ray line excitations. Phantom experiments were performed with a pre-clinical prototype detector, using treatment plans delivered with a clinical pencil-beam scanning system. The detector consisted of an actively shielded lanthanum(III) bromide scintillator. Tungsten was used to collimate the gamma-rays. To support high event rates, the detector readout featured custom amplifiers and an active voltage divider for the photomultiplier. The detector signals were acquired by fast analog-to-digital converters and processed using digital algorithms. The data acquisition was also synchronized with the pencil-beam scanning and dosimetry systems. Results: We successfully acquired prompt gamma-ray spectra during the delivery of proton pencil-beams with a clinical beam current of 2 nA at the exit of the treatment head. The number of events in the primary detector ranged from 1 x 10{sup 6} to 2 x 10{sup 6} per second. In phantom experiments, non-uniform range errors were introduced by placing strips of plastic in the beam path. The magnitudes and positions of these range errors were correctly detected in two-dimensional range maps that were generated from the measurements. With our small scale prototype, a 1.0 mm standard deviation on the absolute range required about 5 x 10{sup 8} protons per delivered pencil-beam. Conclusions: Prompt gamma-ray spectroscopy to verify the absolute range of proton beams was demonstrated under clinical pencil-beam delivery conditions. A 1 mm to 2 mm range verification accuracy for a field delivering 1 Gy, appears feasible with a full scale system. This work was supported by the Federal Share of program income earned on C06-CA059267, Proton Therapy Research and Treatment Center.

60 APPLIED LIFE SCIENCES↗

Beam dynamics in an ultra-low energy storage rings (review of existing facilities and feasibility studies for future experiments)

Storage rings operating at ultra-low energies and in particular electrostatic storage rings have proven to be invaluable tools for atomic and molecular physics. Due to the mass independence of the electrostatic rigidity, these machines are able to store a wide range of different particles, from light ions to heavy singly charged bio-molecules. However, earlier measurements showed strong limitations on beam intensity, fast decay of ion current, reduced life time etc. The nature of these effects was not fully understood. Also a large variety of experiments in future generation ultra-low energy storage and decelerator facilities including in-ring collision studies with a reaction microscope require a comprehensive investigation of the physical processes involved into the operation of such rings. In this paper, we present review of non-linear and long term beam dynamics studies on example of the ELISA, AD Recycler, TSR and USR rings using the computer codes BETACOOL, OPERA-3D and MAD-X. The results from simulations were benchmarked against experimental data of beam losses in the ELISA storage ring. We showed that decay of beam intensity in ultra-low energy rings is mainly caused by ion losses on ring aperture due to multiple scattering on residual gas. Beam is lost on ring aperture due to small ring acceptance. Rate of beam losses increases at high intensities because of the intra-beam scattering effect adds to vacuum losses. Detailed investigations into the ion kinetics under consideration of the effects from electron cooling and multiple scattering of the beam on a supersonic gas jet target have been carried out as well. The life time, equilibrium momentum spread and equilibrium lateral spread during collisions with this internal gas jet target were estimated. In addition, the results from experiments at the TSR ring, where low intensity beam of CF{sup +} ions at 93 keV/u has been shrunk to extremely small dimensions have been reproduced. Based on these simulations, conditions for stable ring operation with extremely low emittance beam are presented. Finally, results from studies into the interaction of ions with a gas jet target at 3–30 keV energy range are summarized.

43 PARTICLE ACCELERATORS↗

Multiple Beam Triode Driven RF Sources for Accelerator Applications Phase I Final Report

Calabazas Creek Research, Inc, (CCR), in collaboration with Microwave Power Products, Inc. (MPP), formerly Communications & Power Industries, LLC (CPI,) and JP Accelerator Works, Inc. (JPAW), embarked on a program to develop multiple beam triodes to produce RF power from 350 – 800 MHz with an average power exceeding 200 kW. The effort was motivated by the performance of a triode-based RF source which produces 25 kW of UHF power at 90% efficiency. The CCR effort focused on implementing this technology into a multiple beam device to increase the output power while retaining the low cost, compact size, and high efficiency. The program performed extensive simulations indicating that the goals could be achieved, and a prototype multiple beam triode was built, baked, and tested. Unfortunately, a grid to cathode short terminated the testing before the tube could generate RF power. Nevertheless, the effort demonstrated that a multiple beam triode could be designed, built, baked, and energized to high voltage. The multiple beam triode used oxide cathodes, which are only capable of pulsed operation. The multiple beam triode will be rebuilt using dispenser cathodes, which will allow high duty or continuous operation. The grids were also modified to be more robust to avoid previous issues. The MB triode will provide the beam power for RF generation. The RF is generated by surrounding the triode with input and output cavities to convert beam power to RF power. RF cavities to generate 200 kW CW at 350-450 MHz using the MB triode with dispenser cathodes was assembled during the program. The next Phase of this effort is to assemble the multiple beam triode using the subassemblies built in the Phase I program and test with the RF cavities. The Phase I program also initiated design of a higher frequency, higher power multiple beam triode. That design is forecast to produce approximately 500 kW CW from 350 - 500 MHz.

43 PARTICLE ACCELERATORS↗

Dose-Response Effect of Charged Carbon Beam on Normal Rat Retina Assessed by Electroretinography

Purpose: To compare the effects of carbon beam irradiation with those of proton beam irradiation on the physiology of the retina of rats. Methods and Materials: Eight-week-old Wister rats were used. The right eyes were irradiated with carbon beam (1, 2, 4, 8, and 16 Gy) or proton beam (4, 8, 16, and 24 Gy) with the rats under general anesthesia. Electroretinograms were recorded 1, 3, 6, and 12 months after the irradiation, and the amplitudes of the a and b waves were compared with those of control rats. Results: The amplitude of b waves was reduced more than that of a waves at lower irradiation doses with both types of irradiation. With carbon ion irradiation, the amplitudes of the b wave were significantly reduced after radiation doses of 8 and 16 Gy at 6 months and by radiation doses of 4, 8, and 16 Gy at 12 months. With proton beam irradiation, the b-wave amplitudes were significantly reduced after 16 and 24 Gy at 6 months and with doses of 8 Gy or greater at 12 months. For the maximum b-wave amplitude, a significant difference was observed in rats irradiated with carbon beams of 4 Gy or more and with proton beams of 8 Gy or more at 12 months after irradiation. Conclusions: These results indicate that carbon beam irradiation is about two times more damaging than proton beam irradiation on the rat retina at the same dose.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Innovative approaches to neutron beam optimization: A case study of FP14 at LANSCE

This paper describes an experimental method to acquire high resolution energy- and spatially- resolved neutron beam spots using the time-gated neutron imaging system with Teledyne Pi-MAX4 camera. These experimental data offer a unique opportunity for benchmarking beam spot simulations. High-quality simulations depend significantly on a high-fidelity geometry model, which can be challenging for legacy facilities. We informed our MCNPX geometry model by latest metrology survey employing Leica laser tracker ATS600. It gave us a high fidelity description of our facility geometry. Such a robust integration of novel tools and methods yields a previously unattainable level of accuracy in both predicting and capturing neutron beam spots, marking a notable advancement over traditional methods reliant on static image plates. Here, to demonstrate the practical application of these tools, we are showing a non-uniform beam spot challenge at our Flight Path 14 (FP14) at the Los Alamos Neutron Science Center (LANSCE). Our precise MCNPX prediction of beam spot shifting as function of neutron energy was confirmed by experimental beam spot measured with extremely high level of detail. Results of this research demonstrate a significant leap in neutron beam optimization at LANSCE and set a new benchmark in beam spot characterization. The advanced methods presented here have potential for adoption at similar research facilities worldwide, aiming at substantial improvement in neutron beam delivery for experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗