Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Accelerators, Instrumentation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,405 records · Page 78

GRIPS-Gamma-Ray burst Investigation via Polarimetry and Spectroscopy

The primary scientific goal of the GRIPS mission [1] is to revolutionize our understanding of the early universe using {gamma}-ray bursts. We propose a new generation gamma-ray observatory capable of unprecedented spectroscopy over a wide range of {gamma}-ray energies (200 keV-50 MeV) and of polarimetry (200-1000 keV). Secondary goals achievable by this mission include direct measurements of supernova interiors through {gamma}-rays from radioactive decays, nuclear astrophysics with massive stars and novae, and studies of particle acceleration near compact stars, interstellar shocks, and clusters of galaxies.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Experimental Methods in Reduced-gravity Soldering Research

The National Center for Microgravity Research, NASA Glenn Research Center, and NASA Johnson Space Center are conducting an experimental program to explore the influence of reduced gravity environments on the soldering process. An improved understanding of the effects of the acceleration environment is important to application of soldering during current and future human space missions. Solder joint characteristics that are being considered include solder fillet geometry, porosity, and microstructural features. Both through-hole and surface mounted devices are being investigated. This paper focuses on the experimental methodology employed in this project and the results of macroscopic sample examination. The specific soldering process, sample configurations, materials, and equipment were selected to be consistent with those currently on-orbit. Other apparatus was incorporated to meet requirements imposed by operation onboard NASA's KC-135 research aircraft and instrumentation was provided to monitor both the atmospheric and acceleration environments. The contingent of test operators was selected to include both highly skilled technicians and less skilled individuals to provide a population cross-section that would be representative of the skill mix that might be encountered in space mission crews.

Pettegrew, Richard D.↗

Methods for extracting aerodynamic accelerations from Orbiter High Resolution Accelerometer Package flight data

This report presents a process for extracting the aerodynamic accelerations of the Shuttle Orbiter Vehicle from the High Resolution Accelerometer Package (HiRAP) flight data during reentry. The methods for obtaining low-level aerodynamic accelerations, principally in the rarefied flow regime, are applied to 10 Orbiter flights. The extraction process is presented using data obtained from Space Transportation System Flight 32 (Mission 61-C) as a typical example. This process involves correcting the HiRAP measurements for the effects of temperature bias and instrument offset from the Orbiter center of gravity, and removing acceleration data during times they are affected by thruster firings. The corrected data are then made continuous and smooth and are further enhanced by refining the temperature bias correction and removing effects of the auxiliary power unit actuation. The resulting data are the current best estimate of the Orbiter aerodynamic accelerations during reentry and will be used for further analyses of the Orbiter aerodynamics and the upper atmosphere characteristics.

Thompson, J. M.↗

Twinac: A Universal Framework for Virtual Accelerator Controls

We propose a universal framework for a system of virtual accelerator controls (Twinac), a standard toolkit for research institutions to design, maintain, and use a real-time, end-to-end "digital twin" of their particle accelerator facility. This virtual counterpart will mirror any physical accelerator to provide (1) predictive maintenance; (2) surveillance of hidden environmental factors, such as seasonal temperature variations, which could impact performance of power supplies, magnets, and other instruments; and (3) a capability to model novel ways to operate the accelerator without risking equipment damage. Twinac is envisioned as accelerator facility agnostic, allowing institutions to share and reuse myriad simulation approaches (analytics-based, A.I.-driven, or combinations of the like) across facilities. The Twinac system lays the groundwork for a collaborative network of institutions to maintain and update this shared virtual accelerator technology.

Miceli, Tia M. [Fermilab] (ORCID:0000000265577789)↗

IMPULSIVE ACCELERATION OF CORONAL MASS EJECTIONS. I. STATISTICS AND CORONAL MASS EJECTION SOURCE REGION CHARACTERISTICS

We use high time cadence images acquired by the STEREO EUVI and COR instruments to study the evolution of coronal mass ejections (CMEs) from their initiation through impulsive acceleration to the propagation phase. For a set of 95 CMEs we derived detailed height, velocity, and acceleration profiles and statistically analyzed characteristic CME parameters: peak acceleration, peak velocity, acceleration duration, initiation height, height at peak velocity, height at peak acceleration, and size of the CME source region. The CME peak accelerations we derived range from 20 to 6800 m s{sup -2} and are inversely correlated with the acceleration duration and the height at peak acceleration. Seventy-four percent of the events reach their peak acceleration at heights below 0.5 R{sub sun}. CMEs that originate from compact sources low in the corona are more impulsive and reach higher peak accelerations at smaller heights. These findings can be explained by the Lorentz force, which drives the CME accelerations and decreases with height and CME size.

79 ASTRONOMY AND ASTROPHYSICS↗

Accelerated electrons and hard X-ray emission from X-pinches

The generation of accelerated electrons in the X-pinch minidiode is studied experimentally. It is well known that the explosion of an X-pinch consisting of two or more wires is accompanied by the formation of a minidiode, in which electrons are accelerated. The subsequent slowing down of electrons in the products of wire explosion causes the generation of hard X-ray (HXR) emission with photon energies higher than 10 keV. In this work, the spatial and temporal characteristics of X-pinch HXR emission are studied, the specific features of HXR generation are discussed, and the capability of applying this radiation to point-projection X-ray imaging of various plasma and biological objects is considered. The parameters of the electron beam produced in the X-pinch are measured using a Faraday cup and X-ray diagnostics. The experiments were performed with the XP generator (550 kA, 100 ns) at Cornell University (United States) and the BIN generator (270 kA, 150 ns) at the Lebedev Physical Institute (Russia).

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Very low frequency waves stimulated by an electron accelerator in the auroral ionosphere

The sounding rocket, Polar 5, carrying a 10 keV electron accelerator in a mother-daughter configuration and other diagnostic instruments, was launched into a slightly disturbed ionosphere with weak auroral activity on February 1, 1976 from Northern Norway to study VLF wave phenomena. The rocket trajectory crossed two auroral regions: one, between 86 and 111 s flight time, and a secondary region between 230 and 330 s. The daughter, carrying the accelerator, was separated axially from the mother in a forward direction at an altitude of 90 km. The VLF experiment, carried by the mother payload, recorded both electromagnetic and electrostatic waves. The receiving antenna was an electric dipole, 0.3 m tip-to-tip, oriented 90 degrees to the rocket spin axis. The onboard particle detector recorded increased electron fluxes in the two auroral regions. A double peaked structure was observed in the fluxes of 4-5 and 12-27 keV electrons within the northern auroral form. The number density of thermal plasma varied during the flight, with maximum density within the main auroral region. To the north of this aurora a slow, steady decrease in the density was observed, with no enhancement in the region of the second aurora.

Holtet, J. A.↗

Study of beam loading and its compensation in the Compact Ultrafast Terahertz Free-Electron Laser injector linac

The RF properties of an accelerating structure, and the pulse structure and charge per bunch in the electron beam propagating through it are important parameters that determine the impact of beam loading in the structure. The injector linac of the Compact Ultrafast Terahertz Free-Electron Laser (CUTE-FEL) has been operated with two different pulse structures during initial commissioning experiments and the effect of beam loading on the accelerated electron beam parameters has been studied analytically for these two pulse structures. This paper discusses the analytical study of beam loading in a Standing Wave, Plane Wave Transformer linac employed in the CUTE-FEL setup, and a possible technique for its compensation for the electron beam parameters of the CUTE-FEL. A parametric study has been performed to study beam loading for different beam currents and to optimize injection time of the electron beam to compensate beam loading. Results from the parametric study have also been used to explain previously observed results from acceleration experiments in the CUTE-FEL setup.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

2-D energy analyzer for low energy electrons

A 2-D electron energy analyzer is designed and constructed to measure the transverse and longitudinal energy distribution of low energy (<1 eV) electrons. The analyzer operates on the principle of adiabatic invariance and motion of low energy electrons in a strong longitudinal magnetic field. The operation of the analyzer is studied in detail and a design to optimize the energy resolution, signal to noise ratio, and physical size is presented. An energy resolution better than 6 meV has been demonstrated. Such an analyzer is a powerful tool to study the process of photoemission which limits the beam quality in modern accelerators.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

International Space Station Modal Correction Analysis

This paper summarizes the on-orbit modal test and the related modal analysis, model validation and correlation performed for the ISS Stage ULF4, DTF S4-1A, October 11,2010, GMT 284/06:13:00.00. The objective of this analysis is to validate and correlate analytical models with the intent to verify the ISS critical interface dynamic loads and improve fatigue life prediction. For the ISS configurations under consideration, on-orbit dynamic responses were collected with Russian vehicles attached and without the Orbiter attached to the ISS. ISS instrumentation systems that were used to collect the dynamic responses during the DTF S4-1A included the Internal Wireless Instrumentation System (IWIS), External Wireless Instrumentation System (EWIS), Structural Dynamic Measurement System (SDMS), Space Acceleration Measurement System (SAMS), Inertial Measurement Unit (IMU) and ISS External Cameras. Experimental modal analyses were performed on the measured data to extract modal parameters including frequency, damping and mode shape information. Correlation and comparisons between test and analytical modal parameters were performed to assess the accuracy of models for the ISS configuration under consideration. Based on the frequency comparisons, the accuracy of the mathematical models is assessed and model refinement recommendations are given. Section 2.0 of this report presents the math model used in the analysis. This section also describes the ISS configuration under consideration and summarizes the associated primary modes of interest along with the fundamental appendage modes. Section 3.0 discusses the details of the ISS Stage ULF4 DTF S4-1A test. Section 4.0 discusses the on-orbit instrumentation systems that were used in the collection of the data analyzed in this paper. The modal analysis approach and results used in the analysis of the collected data are summarized in Section 5.0. The model correlation and validation effort is reported in Section 6.0. Conclusions and recommendations drawn from this analysis are included in Section 7.0.

Fotz[atrocl. Lrostom↗

On angiography with a Thomson laser-electron X-ray generator

We consider a possibility of application of laser-electron X-ray generators for diagnosing the vessel status of internal organs. It is shown that modern lasers and linear accelerators can be used for the development of angiographic instruments of a new type with an increased spatial and temporal resolution while maintaining or reducing the radiation load on the patient and medical staff. Such improvements in diagnostic and ambient factors cannot be achieved with the use of X-ray tubes. All particular estimates and calculations have been performed for a contrast agent based on iodine compounds. (paper)

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Superconducting six-axis accelerometer

A new superconducting accelerometer, capable of measuring both linear and angular accelerations, is under development at the University of Maryland. A single superconducting proof mass is magnetically levitated against gravity or any other proof force. Its relative positions and orientations with respect to the platform are monitored by six superconducting inductance bridges sharing a single amplifier, called the Superconducting Quantum Interference Device (SQUID). The six degrees of freedom, the three linear acceleration components and the three angular acceleration components, of the platform are measured simultaneously. In order to improve the linearity and the dynamic range of the instrument, the demodulated outputs of the SQUID are fed back to appropriate levitation coils so that the proof mass remains at the null position for all six inductance bridges. The expected intrinsic noise of the instrument is 4 x 10(exp -12)m s(exp -2) Hz(exp -1/2) for linear acceleration and 3 x 10(exp -11) rad s(exp -2) Hz(exp -1/2) for angular acceleration in 1-g environment. In 0-g, the linear acceleration sensitivity of the superconducting accelerometer could be improved by two orders of magnitude. The design and the operating principle of a laboratory prototype of the new instrument is discussed.

Paik, H. J.↗

An absolute dose determination of helical tomotherapy accelerator, TomoTherapy High-Art II

Purpose: A helical tomotherapy accelerator presents a dosimetric challenge because, to this day, there is no internationally accepted protocol for the determination of the absolute dose. Because of this reality, we investigated the different alternatives for characterizing and measuring the absolute dose of such an accelerator. We tested several dosimetric techniques with various metrological traceabilities as well as using a number of phantoms in static and helical modes. Methods: Firstly, the relationship between the reading of ionization chambers and the absorbed dose is dependent on the beam quality value of the photon beam. For high energy photons, the beam quality is specified by the tissue phantom ratio (TPR{sub 20,10}) and it is therefore necessary to know the TPR{sub 20,10} to calculate the dose delivered by a given accelerator. This parameter is obtained through the ratio of the absorbed dose at 20 and 10 cm depths in water and was measured in the particular conditions of the tomotherapy accelerator. Afterward, measurements were performed using the ionization chamber (model A1SL) delivered as a reference instrument by the vendor. This chamber is traceable in absorbed dose to water in a Co-60 beam to a water calorimeter of the American metrology institute (NIST). Similarly, in Switzerland, each radiotherapy department is directly traceable to the Swiss metrology institute (METAS) in absorbed dose to water based on a water calorimeter. For our research, this traceability was obtained by using an ionization chamber traceable to METAS (model NE 2611A), which is the secondary standard of our institute. Furthermore, in order to have another fully independent measurement method, we determined the dose using alanine dosimeters provided by and traceable to the British metrology institute (NPL); they are calibrated in absorbed dose to water using a graphite calorimeter. And finally, we wanted to take into account the type of chamber routinely used in clinical practice and therefore measured the dose using a Farmer-type instrument (model NE 2571) as well. Results: We found the tomotherapy TPR{sub 20,10} value to be around 0.629, which is close to a 4 MV conventional linear accelerator value. During static irradiation, the secondary standard and the alanine dosimeters were compatible within 0.5%. The A1SL relative deviation to the secondary standard was 1.2% and the NE2571 relative deviation to the secondary standard was -1.7%. The measurement in dynamic helical mode found the different dosimeters compatible within 1.4% and the alanine dosimeters and the secondary standard were even found under 0.2%. Conclusions: We found that the different methods are all within uncertainties as well as globally coherent, and the specific limitations of the various dosimeters are discussed in order to help the medical physicist design an independent reference system. We demonstrated that, taking into account the particular reference conditions, one can use an ionization chamber calibrated for conventional linear accelerators to assert the absolute dose delivered by a tomotherapy accelerator.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

In-Flight Line-Of-Sight Pointing Performance for the GOES-16 and GOES-17 Spacecraft

The Geostationary Operational Environmental Satellite-R program (GOES-R) has launched two of the next generation geostationary weather satellites, both of which are now fully operational. GOES-16 launched in November 2016, and GOES-17 launched in March 2017. In this paper, we present the pointing and pointing stability results of the two spacecraft, with specific focus on aspects of the design related to mitigating jitter. The flight instrument suite includes 6 seismic accelerometers sampled at approximately 2 kilohertz, allowing in-flight verification of pointing stability and comparison back to simulation predictions. This paper compares the observed flight results with the simulation predictions for acceleration and shock response spectrum (SRS) for various operational scenarios and instrument observation modes. Passive isolation of both the reaction wheels and the payload deck have proved to be effective in reducing jitter responses. Active Vibration Damping (AVD) of flexible-body modes attenuates the low frequency motion of the vehicle appendages, improving the low-frequency pointing performance. Knowledge of the instrument scan mirror motion is fed forward to the reaction wheel control, reducing disturbances on the spacecraft bus. Attitude knowledge and rate data are provided to the primary Earth-observing instrument with an accuracy defined by the Integrated Rate Error (IRE) requirements. The data are used to adjust instrument scanning. As we show in this paper, the in-flight performance of the GN&C (Guidance, Navigation and Control) design provides the necessary capabilities to achieve the demanding GOES-R mission objectives while its robustness enabled the simultaneous operation of the Advanced Baseline Imager (ABI) prime and redundant cryocoolers (CCs) to resolve an in-flight cooling anomaly on GOES-17.

Line-of-Sight↗

Overview of SNS accelerator shielding analyses

The Spallation Neutron Source is an accelerator driven neutron scattering facility for materials research. During all phases of SNS development, including design, construction, commissioning and operation, extensive neutronics work was performed in order to provide adequate shielding, to assure safe facility operation from radiation protection point of view, and to optimize performance of the accelerator and target facility. Presently, most of the shielding work is concentrated on the beam lines and instrument enclosures to prepare for commissioning, safe operation and adequate radiation background in the future. Although the accelerator is built and in operation mode, there is extensive demand for shielding and activation analyses. It includes redesigning some parts of the facility, facility upgrades, designing additional structures, storage and transport containers for accelerator structures taken out of service, and performing radiation protection analyses and studies on residual dose rates inside the accelerator. (authors)

43 PARTICLE ACCELERATORS↗

A hybrid data acquisition system for magnetic measurements of accelerator magnets

A hybrid data acquisition system was developed for magnetic measurement of superconducting accelerator magnets at LBNL. It consists of a National Instruments dynamic signal acquisition (DSA) card and two Metrolab fast digital integrator (FDI) cards. The DSA card records the induced voltage signals from the rotating probe while the FDI cards records the flux increment integrated over a certain angular step. This allows the comparison of the measurements performed with two cards. In this note, the setup and test of the system is summarized. With a probe rotating at a speed of 0.5 Hz, the multipole coefficients of two magnets were measured with the hybrid system. The coefficients from the DSA and FDI cards agree with each other, indicating that the numerical integration of the raw voltage acquired by the DSA card is comparable to the performance of the FDI card in the current measurement setup.

43 PARTICLE ACCELERATORS↗

Review of the Lujan neutron scattering center: basic energy sciences prereport February 2009

The Lujan Neutron Scattering Center (Lujan Center) at LANSCE is a designated National User Facility for neutron scattering and nuclear physics studies with pulsed beams of moderated neutrons (cold, thermal, and epithermal). As one of five experimental areas at the Los Alamos Neutron Science Center (LANSCE), the Lujan Center hosts engineers, scientists, and students from around the world. The Lujan Center consists of Experimental Room (ER) 1 (ERl) built by the Laboratory in 1977, ER2 built by the Office of Basic Energy Sciences (BES) in 1989, and the Office Building (622) also built by BES in 1989, along with a chem-bio lab, a shop, and other out-buildings. According to a 1996 Memorandum of Agreement (MOA) between the Defense Programs (DP) Office of the National Nuclear Security Agency (NNSA) and the Office of Science (SC, then the Office of Energy Research), the Lujan Center flight paths were transferred from DP to SC, including those in ERI. That MOA was updated in 2001. Under the MOA, NNSA-DP delivers neutron beam to the windows of the target crypt, outside of which BES becomes the 'landlord.' The leveraging nature of the Lujan Center on the LANSCE accelerator is a substantial annual leverage to the $11 M BES operating fund worth approximately $56 M operating cost of the linear accelerator (LINAC)-in beam delivery.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Use of indentation to study the degradation of photovoltaic backsheets

The ability of electrical insulating materials within a module to act as insulators is a key safety requirement for photovoltaic (PV) technology. Presently, however, the durability of backsheets may not be readily assessed. For example, the mechanical tensile test continues to be developed, and its use has not been validated such that a technically based pass/fail criteria may be established. This study examines the use of simple indentation methods, including durometer hardness and instrumented indentation, as a means to quantitively assess the degradation of PV backsheets. Characteristics including: hardness, modulus, load/displacement profile, creep hold response, and residual impression are explored in an empirical study. Glass/encapsulant/backsheet mini-modules constructed using backsheets including: polyamide (PA), poly(ethylene terephthalate) (PET), polyvinyl fluoride (PVF) laminate ('TPE'), and polyvinylidene fluoride (PVDF) were examined. An M-type durometer as well as Berkovich and cube-corner tips were used in the indentation experiments. Additional characterizations were performed to interpret the indentation measurements including: surface roughness measurements using atomic force microscopy (AFM), a chemical integrity study using Fourier-transform infrared spectroscopy (FTIR), and phase-transition measurements using differential scanning calorimetry (DSC). The results are analyzed in the context of the combined accelerated stress test (C-AST) also explored in this study. Instrumented indentation (i.e., using a Berkovich tip) was able to distinguish between backsheets and quantify the effects of accelerated testing (including up to 60%, 25%, and 20% change in hardness, modulus, and creep displacement, respectively). The embrittlement of the backsheets was not readily assessable using cube-corner indentation. Cracking of the known-bad polyamide backsheet was observed from the C-AST, which was not observed to result from steady state UV weathering.

14 SOLAR ENERGY↗