Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “AIR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,405 records · Page 78

Dry Air Cooler Modeling for Supercritical Carbon Dioxide Brayton Cycle Analysis

Modeling for commercially available and cost effective dry air coolers such as those manufactured by Harsco Industries has been implemented in the Argonne National Laboratory Plant Dynamics Code for system level dynamic analysis of supercritical carbon dioxide (sCO 2 ) Brayton cycles. The modeling can now be utilized to optimize and simulate sCO 2 Brayton cycles with dry air cooling whereby heat is rejected directly to the atmospheric heat sink without the need for cooling towers that require makeup water for evaporative losses. It has sometimes been stated that a benefit of the sCO 2 Brayton cycle is that it enables dry air cooling implying that the Rankine steam cycle does not. A preliminary and simple examination of a Rankine superheated steam cycle and an air-cooled condenser indicates that dry air cooling can be utilized with both cycles provided that the cycle conditions are selected appropriately

42 ENGINEERING↗

User-Oriented Modeling Tools for Advanced Hybrid and Climate-Appropriate Rooftop Air Conditioners

Hybrid unitary air conditioning systems offer a pathway to substantially reduce energy use and peak electrical demand for cooling, heating, and ventilation in commercial buildings. Hybrid air conditioners incorporate multiple subsystems that are carefully orchestrated to provide climate- and application-specific efficiency advantages. There are a multitude of hybrid system architectures, but common subsystems include: heat recovery ventilation, indirect evaporative cooling, desiccant dehumidification, variable speed fans, modulating dampers, and multi-stage or variable-speed vapor compression cooling. Categorically, hybrid systems can operate in numerous discrete modes. For example: indirect evaporative cooling may operate for periods when the subsystem provides adequate sensible cooling, then vapor compression cooling will be included when more cooling or dehumidification is necessary. Laboratory assessments, field studies, and simulations have demonstrated that hybrid unitary air conditioners could reduce energy use for cooling and ventilation by 30-90% depending on climate and application. Heretofore, it has been challenging - if not impossible - for practitioners to model hybrid air conditioners as part of building energy simulations; and the limitation has severely obstructed broader adoption of technologies in this class. In this project, we developed a new feature for EnergyPlus that enables modeling hybrid unitary air conditioning equipment for building energy simulations. This is a significant advancement for both theory and practice, and confers public benefit by enabling practitioners to evaluate this compelling efficiency technology as a part of building energy simulations. The feature is a black-box model that requires extensive performance data for each hybrid unitary product. In parallel, we also developed new features for the Technology Performance Exchange to enable manufacturers to submit performance data in a standard format that can be used with the hybrid unitary model in EnergyPlus. Additionally, through this project we expanded university educational resources, and university- manufacturing industry collaborations in the field of energy efficiency technology. Over two years, we involved 20 undergraduate students in ambitious research projects focused on modeling complex multi-mode mechanical systems, supported three mechanical engineering bachelor theses, established undergraduate apprenticeships with multiple industry partners, and involved those partners in the process of design, validation, and debugging for the new EnergyPlus feature. The EnergyPlus feature is described and discussed in an academic article, as well as in an engineering reference, and input/output reference documentation for EnergyPlus. The Technology Performance Exchange features are live and publicly accessible, our manufacturer partners are primed to submit initial product information and performance data to the exchange, and the EnergyPlus feature is scheduled for public release in Spring 2018 as a part of EnergyPlus v8.9.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Improving Energy Efficiency of Air Separation via Hollow Fiber Sorbents

This report summarizes the work performed under the Department of Energy’s National Energy Technology Laboratory (DOE-NETL) Advanced Energy Systems Program award number DE-FE0026163 Improving Energy Efficiency of Air Separation via Hollow Fiber Sorbents. The overall objective of the project was to develop technology to produce oxygen for use in coal gasification processes at a significantly lower cost than that of the commercial state-of-the-art technology. The focus of the project was development and optimization of hollow fiber sorbents for use in a pressure swing adsorption (PSA) process for producing oxygen from air. The key technical advancement under this program was the development of a hollow fiber sorbent capable of producing oxygen in a PSA process. PSAs produce oxygen by using a beaded zeolite material (typically lithium exchanged zeolites or LiX) that selectively adsorb nitrogen over oxygen. For a fiber to adsorb nitrogen, LiX needed to be integrated into a polymer fiber and then activated at over 350C to remove residual moisture. After screening multiple materials and process techniques, Matrimid/LiX hollow fibers were produced that were able to withstand the activation and had crystalline nitrogen capacity close to pure LiX crystals. The fibers were dual layer fibers with a barrier layer isolating the hollow bore from the LiX embedded layer. The barrier layer was formed from an Ultem® based solution. The hollow bore was intended for encapsulating phase change materials to ensure isothermal PSA operation. Modeling work from the project suggested that the benefits of this additional complexity were marginal, thus the team fabricated non-hollow fibers comprised of Matrimid and LiX. The Matrimid/LiX fibers were loaded into a module and tested on a bench scale PSA unit. The fibers were able to separate oxygen from air, but the purity and recovery were lower than expected and lower than traditional beaded LiX zeolites, although modeling results suggested that the bed sizes for fiber sorbents could be half the size of a beaded LiX bed. Additional work will be needed to understand the shortfall and to produce fiber sorbent modules with performance equal to the targets set for this program. In addition to producing fibers, modeling work was carried out at both the fiber level and process level to guide both fiber sorbent development and to determine the optimal process conditions for a PSA using fiber sorbents. A 2D hollow fiber model was developed in gPROMS Model Builder. This model was based on literature data for mass transfer and other parameters. This model used a basic single bed PSA process to determine important fiber properties and process conditions for achieving high oxygen recovery. The preliminary 2D fiber model was a valuable tool, however, for step-out technologies, such as a PSA process with fiber sorbents, intelligent optimization and plant control was needed to effectively determine minimum power designs. Therefore, a gPROMS Process Builder-based optimization tool was developed with an “Automated Cycle Optimizer” model that was able to determine optimal cycle conditions for a fiber sorbent PSA. The results from the optimizer were used in the final power analysis. Flow sheet analysis and techno-economic analysis (TEA) was carried out to determine a lower power solution versus the baseline case. The original project scope suggested that the fiber sorbent PSA could be used to debottleneck a cryogenic air separation plant (cryo-ASU) with the combined plant having lower power than a standalone cryo-ASU. However, early flowsheet analysis showed that the PSA/cryo-ASU concept would not lead to a lower power solution. However, further flowsheet analysis suggested that an oxygen PSA combined with a nitrogen PSA could have lower power versus state-of-the-art air separation technology. Work concluded with the TEA showing a fiber sorbent oxygen PSA combined with an advanced nitrogen PSA could be up to 8% lower power versus the base case cryo-ASU. Overall, there is significant potential remaining for the zeolite hollow fiber sorbent concept, and this project successfully identified -- and ultimately remedied -- many technical challenges associated with scale-up.

01 COAL, LIGNITE, AND PEAT↗

Counterflow Virtual Impactor (CVI) Inlet Aboard Aircraft (INLETCVI-AIR) Instrument Handbook

The counterflow virtual impactor (CVI) inlet separates out and samples cloud elements via inertial impaction. Warm, dry, particle-free carrier gas of known composition is pumped to the tip of the inlet in the direction opposite of the flow of air. The flow lines of the incoming free stream air are split. Larger droplets and ice crystals suspended in the sample air have enough inertia to penetrate the counterflow and enter the sample flow, while smaller, unactivated particles follow the streamlines of the air flowing around the inlet’s tip (Noone et al. 1988). The instrument is capable of sampling cloud elements as a function of cut size by changing the velocity of counterflow at the probe tip. The CVI cut size is usually defined as a diameter of a smallest particle for which penetration rate is 50%. For the U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) user facilityGulfstream-159 aircraft’s CVI inlet, that value is usually around 13 microns. The dry heated air, normally used as the carrier gas, also serves to evaporate water from the hydrometeor, leaving the residuals to be sampled by in-cabin aerosol instrumentation. The number concentration of the droplet residue in the CVI sample line is usually increased with respect to corresponding cloud element number concentration. The CVI performance as a concentrator is usually described via CVI enhancement factor, which is a conversion factor between ambient volumetric concentration (not adjusted to standard temperature and pressure) and volumetric concentration in the CVI sample line.

54 ENVIRONMENTAL SCIENCES↗

Accelerated Scaling to Rapid Open-Air Fabrication of Durable Perovskite Solar Modules

The goals of this SETO project (DE-EE0008559, Accelerated Scaling to Rapid Open-Air Fabrication of Durable Perovskite Solar modules) are to address the principal challenges towards the successful commercialization of perovskite solar modules utilizing scalable, high-throughput open-air spray deposition. The successful outcome of the project will provide the foundation of an all open-air spray deposited perovskite solar module with hole transport layer (HTL), perovskite, electron transport layer (ETL), and barrier layer development while establishing a fundamental understanding of perovskite device behavior under accelerated aging conditions. Through this program, we have made significant progress towards a commercializable pathway for perovskites. (1) We’ve demonstrated the successful open-air deposition of perovskite and transport layer materials. These deposition methods were chosen for their inherent scalability, and open-air processing enables a significant reduction in processing costs. These methods are also compatible with high throughputs, demonstrating the fastest perovskite film deposition at these performance levels. (2) Development of a unique all-fiber laser scribing procedure provides a high-performance, low-cost method for further improvements in scalability. (3) Our group has also placed a unique emphasis on device stability. The development of testing standards for perovskite modules is required to thoroughly evaluate potential candidates for commercialization, and we’ve taken inspiration from current industry standards to provide an honest insight into the performance and reliability of our devices. (4) An extensive cost model detailing the specific contributions of each device layer and production component provides the most thorough evaluation of any perovskite technology against conventional silicon and compound semiconductor solar devices. The cost model is a critical advancement that will provide the foundation for evaluating the levelized cost of energy (LCOE) of this technology.

14 SOLAR ENERGY↗

End-Use Savings Shapes Measure Documentation: Console Water-to-Air Geothermal Heat Pump

Executive Summary Building on the successfully completed effort to calibrate and validate the U.S. Department of Energy’s ResStock™ and ComStock™ models over the past several years, the objective of this work is to produce national datasets that empower analysts working for federal, state, utility, city, and manufacturer stakeholders to answer a broad range of analysis questions. The goal of this work is to develop energy efficiency, electrification, and demand flexibility end-use load shapes (electricity, gas, propane, or fuel oil) that cover most of the high-impact, market-ready (or nearly market-ready) measures. An end-use savings shape is the difference in energy consumption between a baseline building and a building with an energy efficiency, electrification, or demand flexibility measure applied. It results in a time series profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each time step. ComStock is a highly granular, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual sub-hourly energy consumption of the commercial building stock across the United States. The baseline model intends to represent the U.S. commercial building stock as it existed in 2018. This measure models the conversion of an existing heating, ventilating, and air-conditioning (HVAC) system to a series of “console” water-to-air heat pumps served by a ground heat exchanger. Console water-to-air geothermal heat pumps (GHP) are all-in-one packages that have no or minimal ductwork and serve individual spaces. Properly designed ground heat exchanger-coupled systems can offer benefits in energy efficiency relative to “conventional” HVAC systems, as well as facilitating beneficial electrification. Console GHPs can be coupled to a ground loop on the source side and can directly replace electric baseboard heaters or air-source packaged terminal heat pumps. Console GHPs can also bring in outdoor air for ventilation. This measure will be referred to throughout the document as the “Console GHP” upgrade.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Ash Fouling Free Regenerative Air Preheater for Deep Cyclic Operation

The University of Kentucky (UKy) project titled “Ash Fouling Free Regenerative Air Preheater for Deep Cyclic Operation”, DE-FE0031757, was conducted from 8/15/2019 to 8/14/2024 in two Budget Periods. Other participants included PPL Corporation and Black Dragon Double Boiler. The overall goal was to investigate the proposed self-cleaning technology to achieve ash fouling free air preheater operation in a coal-fired power plant, especially during deep cycling. All project deliverables, milestones, and success criteria were met. UKy obtained the following scientific findings. • Temporary and periodic high temperature of heating elements (450 ~ 500 °F) can prevent ash accumulation and maintain air preheater free of clogging. • The ash samples analysis and unit operation provide solid evidence of ABS formed during low load with SCR ammonia slip being the major cause of ash accumulation, and air preheater clogging can be prevented by raising the heating element temperature up to 450 °F~ 500 °F at which ABS is decomposed. • In-situ self-cleaning can be controlled by monitoring temperature and/or presetting fixed number of cleanings per day. Both approaches in pilot testing show positive results for maintaining an ash free state for the air preheater. • Temperature criteria (cold end or gas outlet temperature) for entering self-cleaning service is critical to balance the number of cleaning cycles with maintaining the ash level. • Temperature criteria (cold end or gas outlet temperature) for exiting self-cleaning service is critical to balance the duration of the cleaning cycles with maintaining the ash level.

01 COAL, LIGNITE, AND PEAT↗

ComStock Measure Documentation: Ideal Thermal Air Loads

This study provides hypothetical thermal heating and cooling loads for ComStock models representing the U.S. commercial building stock. This measure scenario removes all HVAC models from the baseline ComStock building model and instead uses "ideal air" to meet loads. "Ideal air" can be thought of as an HVAC unit that mixes air at the zone exhaust condition with the specified amount of outdoor air, and then adds or removes heat and moisture at 100% efficiency to produce a supply air stream at the specified conditions. The resulting ideal thermal loads are represented under the "district" fuel type for both heating and cooling and can be found in both annual and timeseries results in the ComStock public dataset. This measure scenario does not represent any real technology or improvement, but rather, serves as a resource for thermal heating and cooling loads for buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

High Efficiency and Transient Air Systems for Affordable Load-Following Heavy Duty Truck Fuel Cells

Hydrogen fuel cell powered vehicles are one of the potential paths to reducing vehicle emissions. An important subsystem of the hydrogen fuel cell system is an air handling system that provides the needed oxygen (in air) to react with hydrogen in the fuel cell stack for electric power generation. Today’s systems use an electric motor to power an air compressor that supplies oxygen to the fuel cell stack. This process requires significant electrical power and is the largest parasitic power loss in hydrogen fuel cell vehicles. In addition to parasitic power loss, hydrogen fuel cell systems often have reliability issues associated with the air handling system. Reliability is of significant concern for heavy duty applications (especially long-haul applications). This project aims to improve both the electrical power consumption and reliability of hydrogen fuel cell air handling systems to meet the needs of heavy duty on-highway vehicle applications.

08 HYDROGEN↗

Laser sintering of Al nanoparticles for Al-air batteries

With the growing price of lithium material and associated safety concerns, there is an urgent need for developing new efficient, cost-effective battery systems as a successor for lithium ion batteries. Metal-air batteries have drawn huge attention and interest as energy storage devices due to their high theoretical energy density when Al, Zn, Ni, and Fe are used. In particular, Al-air batteries have the potential to become a promising primary battery system with their relatively low prices and significantly high energy density. In this paper, the authors report a printed Al anode for Al-air battery combined with a laser sintering method. The anode was fabricated by Al nanoparticle ink using squeezing printing. Furthermore, a laser sintering method was applied to remove the organic solvent in the slurry and increase the conductivity of the printed anode. By application of infrared laser sintering, the authors significantly improved electrical conductivity of Al nanoparticles and electrochemical performance of Al-air cells. A Pt/C coated hydrophobicity carbon paper was used for the air cathode to provide a good electrical conductivity, an oxygen flow ability, and the water vapor sealing. Gel-style KOH was introduced as the electrolyte, and waterways were also utilized in the chemical reaction. The authors show a full battery cell with a printed Al anode on flexible substrates. This microbattery can provide a 227 mWh/g energy density and a 239 mAh/g capacity at an operation voltage of 0.95 V.

25 ENERGY STORAGE↗

National Park Air Quality Index Dataset

The National Park Air Quality Index dataset (NPS-AQI) consists of webcam images taken from the National Park Service's publicly available air quality web cameras and associated measurements for air pollutants, AQI, and meteorological data obtained via the publicly available NPS Gaseous Pollutant Monitoring Program. The full dataset is a collection of 146,822 images paired with air quality measurements. The specific measurements reported are: ozone ppm, 8-hour running average ozone ppm, so2 ppm, AQI (derived from ozone), temperature, and humidity. The images are 1500X1000 pixel PNG files arranged into folders by NPS site and named according to the time and date the image was taken. There are three CSV files (representing "training", "validation", and "testing" images splits) containing image names and associated NPS site names, air pollutant measurements, and meteorlogical data.

Svinth, Christian N↗

A framework for calibrating and validating an air loop dynamic model in an HVAC system in Modelica

The use of Modelica for simulating the dynamic behaviors of building heating, ventilation, and air conditioning (HVAC) systems has gained popularity. Calibration of a model that represents large and complex HVAC systems in Modelica involves the determination of hundreds of parameters using real-world operation data. Considering the coupling effects among various components, such a calibration process is complex and time-consuming. In this study, we propose a systematic framework to efficiently calibrate and validate a complex HVAC system model in Modelica. The framework includes strategies to solicit real-system operation data and to decouple the model. The goal of this calibration framework is to accurately and efficiently determine a set of Modelica model parameters that provide a good match between the simulated and real system behaviors. To demonstrate the validity of the framework, it was applied to calibrate the parameters of a Modelica model of the air loop subsystem of a real AHU-VAV system. The results show that the calibrated model can generate simulated results, including VAV air flow rate, outdoor air flow, and fan power consumption, that match well with the operational data of the real system. The coefficient of the variation of the root mean square error, CV(RMSE), of the air flow rate and power consumption are 14.6 % and 11.5 %, respectively. The results prove that the framework is valid and effective, and it can be used to calibrate other complex HVAC system Modelica models in the future.

Li, Yicheng↗

Impacts of a Prescribed Fire on Air Quality in Central New Mexico

A short-duration but high-impact air quality event occurred on 28 November 2018 along the Rio Grande Valley of New Mexico. This fire occurred outside the typical wildfire season, and greatly impacted the air quality in Socorro, NM, and the surroundings. Measurements were taken during the event using an aerosol light scattering technique (integrating nephelometer) and a particulate mass concentration monitor (DustTrak PM optical monitor). The instruments sampled the ambient air during the event on the campus of the New Mexico Institute of Mining and Technology in Socorro, New Mexico. The peak values on a 5-min basis of light scattering and the PM mass concentration reached 470 Mm -1 and 270 µg/m 3 , respectively. We examined the meteorological context of the event using local meteorological data and back trajectories using the NOAA HYSPLIT model to determine atmospheric transport and possible sources. Several fires, both prescribed and wildfires, occurred in the region including a prescribed burn at Bosque del Apache National Wildlife Refuge (17 km south-southeast of the receptor site). The data suggest that the prescribed burn at Bosque del Apache was the dominant contributor due to transport evidence and the event’s narrow spatiotemporal extent. The increasing importance of restoring ecosystem function using prescribed fire in wildland fire management will likely lead to more frequent air quality impacts and sets up policy tradeoffs that require a balance between these public goals. This study examines the evidence of the effects of a prescribed fire in a protected wildland area impacting the air quality in a nearby populated area.

54 ENVIRONMENTAL SCIENCES↗

Atmospheric teleconnection processes linking winter air stagnation and haze extremes in China with regional Arctic sea ice decline

Abstract. Recent studies suggested significant impacts of boreal cryosphere changes on wintertime air stagnation and haze pollution extremes in China. However, the underlying mechanisms of such a teleconnection relationship remains unclear. Here we use the Whole Atmosphere Community Climate Model (WACCM) to investigate dynamic processes leading to atmospheric circulation and air stagnation responses to Arctic sea ice changes. We conduct four climate sensitivity experiments by perturbing sea ice concentrations (SIC) and corresponding sea surface temperature (SST) in autumn and early winter over the whole Arctic and three subregions in the climate model. The results indicate distinct responses in circulation patterns and regional ventilation to the region-specific Arctic changes, with the largest increase of both the probability (by 132 %) and the intensity (by 30 %) of monthly air stagnation extremes being found in the experiment driven by SIC and SST changes over the Pacific sector of the Arctic (the East Siberian and Chukchi seas). The increased air stagnation extremes are mainly driven by an amplified planetary-scale atmospheric teleconnection pattern that resembles the negative phase of the Eurasian (EU) pattern. Dynamical diagnostics suggest that convergence of transient eddy forcing in the vicinity of Scandinavia in winter is largely responsible for the amplification of the teleconnection pattern. Transient eddy vorticity fluxes dominate the transient eddy forcing and produce a barotropic anticyclonic anomaly near Scandinavia and wave train propagation across Eurasia to the downstream regions in East Asia. The piecewise potential vorticity inversion analysis reveals that this long-range atmospheric teleconnection of Arctic origin takes place primarily via the middle and upper troposphere. The anomalous ridge over East Asia in the middle and upper troposphere worsens regional ventilation conditions by weakening monsoon northwesterlies and enhancing temperature inversions near the surface, leading to more and stronger air stagnation and pollution extremes over eastern China in winter. Ensemble projections based on state-of-the-art climate models in the Coupled Model Intercomparison Project Phase 6 (CMIP6) corroborate this teleconnection relationship between high-latitude environmental changes and midlatitude weather extremes, though the tendency and magnitude vary considerably among each participating model.

54 ENVIRONMENTAL SCIENCES↗

Technical note: AQMEII4 Activity 1: evaluation of wet and dry deposition schemes as an integral part of regional-scale air quality models

We present in this technical note the research protocol for phase 4 of the Air Quality Model Evaluation International Initiative (AQMEII4). This research initiative is divided into two activities, collectively having three goals: (i) to define the current state of the science with respect to representations of wet and especially dry deposition in regional models, (ii) to quantify the extent to which different dry deposition parameterizations influence retrospective air pollutant concentration and flux predictions, and (iii) to identify, through the use of a common set of detailed diagnostics, sensitivity simulations, model evaluation, and reduction of input uncertainty, the specific causes for the current range of these predictions. Activity 1 is dedicated to the diagnostic evaluation of wet and dry deposition processes in regional air quality models (described in this paper), and Activity 2 to the evaluation of dry deposition point models against ozone flux measurements at multiple towers with multiyear observations (to be described in future submissions as part of the special issue on AQMEII4). The scope of this paper is to present the scientific protocols for Activity 1, as well as to summarize the technical information associated with the different dry deposition approaches used by the participating research groups of AQMEII4. In addition to describing all common aspects and data used for this multi-model evaluation activity, most importantly, we present the strategy devised to allow a common process-level comparison of dry deposition obtained from models using sometimes very different dry deposition schemes. The strategy is based on adding detailed diagnostics to the algorithms used in the dry deposition modules of existing regional air quality models, in particular archiving diagnostics specific to land use–land cover (LULC) and creating standardized LULC categories to facilitate cross-comparison of LULC-specific dry deposition parameters and processes, as well as archiving effective conductance and effective flux as means for comparing the relative influence of different pathways towards the net or total dry deposition. This new approach, along with an analysis of precipitation and wet deposition fields, will provide an unprecedented process-oriented comparison of deposition in regional air quality models. Examples of how specific dry deposition schemes used in participating models have been reduced to the common set of comparable diagnostics defined for AQMEII4 are also presented.

54 ENVIRONMENTAL SCIENCES↗

The CHRONOS mission: capability for sub-hourly synoptic observations of carbon monoxide and methane to quantify emissions and transport of air pollution

The CHRONOS space mission concept provides time-resolved abundance for emissions and transport studies of the highly variable and highly uncertain air pollutants carbon monoxide and methane, with sub-hourly revisit rate at fine (-4 km) horizontal spatial resolution across a North American domain. CHRONOS can provide complete synoptic air pollution maps ("snapshots") of the continental domain with less than 10 min of observations. This rapid mapping enables visualization of air pollution transport simultaneously across the entire continent and enables a sentinel-like capability for monitoring evolving, or unanticipated, air pollution sources in multiple locations at the same time with high temporal resolution. CHRONOS uses a compact imaging gas filter correlation radiometer for these observations, with heritage from more than 17 years of scientific data and algorithm advances by the science teams for the Measurements of Pollution in the Troposphere (MOPITT) instrument on NASA's Terra spacecraft in low Earth orbit. To achieve continental-scale sub-hourly sampling, the CHRONOS mission would be conducted from geostationary orbit, with the instrument hosted on a communications or meteorological platform. CHRONOS observations would contribute to an integrated observing system for atmospheric composition using surface, suborbital and satellite data with atmospheric chemistry models, as defined by the Committee on Earth Observing Satellites. Addressing the U.S. National Academy's 2007 decadal survey direction to characterize diurnal changes in tropospheric composition, CHRONOS observations would find direct societal applications for air quality management and forecasting to protect public health.

54 ENVIRONMENTAL SCIENCES↗

A novel Whole Air Sample Profiler (WASP) for the quantification of volatile organic compounds in the boundary layer

The emission and fate of reactive VOCs is of inherent interest to those studying chemical biosphere-atmosphere interactions. In-canopy VOC observations are obtainable using tower-based samplers, but the lack of suitable sampling systems for the full boundary 5 layer has limited the data characterizing the vertical structure of such gases above the canopy height and still in the boundary layer. This is the important region where many reactive VOCs are oxidized or otherwise removed. Here we describe an airborne sampling system designed to collect a vertical profile of air into a 3/800 OD tube 150m in length. The inlet ram air pressure is used to flow sampled air through the 10 tube, which results in a varying flow rate based on aircraft speed and altitude. Since aircraft velocity decreases during ascent, it is necessary to account for the variable flow rate into the tube. This is accomplished using a reference gas that is pulsed into the air stream so that the precise altitude of the collected air can be reconstructed post-collection. The pulsed injections are also used to determine any significant effect 15 from diffusion/mixing within the sampling tube, either during collection or subsequent extraction for gas analysis. This system has been successfully deployed, and we show some measured vertical profiles of isoprene and its oxidation products methacrolein and methyl vinyl ketone from a mixed canopy near Columbia, Missouri.

Mak, J. E.↗

Pneumatic power is transmitted through air bearing

A more efficient method for supplying high pressure air to an air bearing and pneumatic equipment mounted on it has been developed. The system uses a conventional air bearing and an air-supported sphere with a central passage. High pressure air is channeled through it into the pneumatic equipment on the sphere.

Johnson, H. I.↗