Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “3D model”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,405 records · Page 78

Rapid Model Import Tool (RMIT)

Our project is about developing a tool to implement conversion of 3D Computer Aided Design (CAD) models produced with software such as Delmia, 3DS Max, or Maya, into a size and format compatible with the Unity 3D environment. RMIT will be used to aid KSC engineering personnel in the design, development, testing, operations, and training on spacecraft, launch vehicles, facilities, and ground support equipment. For our project, we are using Blender, a free/open-source 3D graphics software, with the goal of developing, testing, and deploying a 3D CAD model converter tool. I worked on using Blender to import 3D CAD models exported from CATIA software into Collada file format. The Collada file format has file extension DAE. Importing the Collada DAE file as is into Blender, generates dots and dashes. In 3DS Max, there is an existing OpenCollada plugin and with that plugin, 3DS Max can import the DAE file successfully. But, Blender does not seem to have an OpenCollada plugin, so I worked on writing a new OpenCollada plugin for Blender. Since 3DS Max was able to display the image, I looked into comparing differences between the original DAE file and the DAE file exported from 3DS Max using the OpenCollada plugin. As Collada documents describing digital assets are XML files with file extension DAE, Collada files contains XML tags, making them easily modifiable. After some research, it appears that Blender does not like primitive 2D tags like tristrips and trifans. Changing those tags to polygons slightly improved the image, but the pieces were exploded. I found after further research comparing differences between the original file and the file exported from 3DS Max that the values inside the translate tags in the original file are scaled down by a factor of 25.4 in the exported file from 3DS Max, representing the millimeters to inches conversion (1 inch = 25.4 millimeters). After scaling down values inside all of the translate tags by 25.4, the exploded pieces stuck back in, but the image needed further improvement. I have been able to create a new plugin in Blender that takes the original DAE file, replaces the primitive 2D tags tristrips and trifans with polygons, scales down the values inside the translate tags by a factor of 25.4, and saves the changes into a temporary DAE file. After the temporary DAE file is imported into Blender, the temp file is then deleted, keeping the original DAE file intact. Starting with a DAE file that is exported using the NASA Enterprise Visualization Application (NEVA), a Collada exporter, from CATIA gives better results. NEVA is a Design Visualization product that is used for exporting 3D models from CATIA. With NEVA, the up axis is defined in the top-level node if navigation gravity is enabled. With that file, just replacing the primitive tags tristrips and trifans with polygons in yields a much improved image in Blender. As we identify more differences between the original DAE file and the DAE file exported from 3DS Max, this plugin can be improved further. Our goal is to have a model that is formatted and sized for import into Unity, and we are trying out different 3D programs to see which will work best.

Ayyangar, Arjun↗

Transient Analysis of Thermal Protection System for X-33 Aircraft using MSC/NASTRAN

X-33 is an advanced technology demonstrator vehicle for the Reusable Launch Vehicle (RLV) program. The thermal protection system (TPS) for the X-33 is composed of complex layers of materials to protect internal components, while withstanding severe external temperatures induced by aerodynamic heating during high speed flight. It also serves as the vehicle aeroshell in some regions using a stand-off design. MSC/NASTRAN thermal analysis capability was used to predict transient temperature distribution (within the TPS) throughout a mission, from launch through the cool-off period after landing. In this paper, a typical analysis model, representing a point on the vehicle where the liquid oxygen tank is closest to the outer mold line, is described. The maximum temperature difference between the outer mold line and the internal surface of the liquid oxygen tank can exceed 1500 F. One dimensional thermal models are used to select the materials and determine the thickness of each layer for minimum weight while insuring that all materials remain within the allowable temperature range. The purpose of working with three dimensional (3D) comprehensive models using MSC/NASTRAN is to assess the 3D radiation effects and the thermal conduction heat shorts of the support fixtures.

Miura, Hirokazu↗

Final Report for USGS NEHRP Project 08HQGR0022

This is the final report for United States Geological Survey (USGS) National Earthquake Hazard Reduction Program (NEHRP) Project 08HQGR0022, entitled “Quantifying Uncertainties in Ground Motion Simulations for Scenario Earthquakes on the HaywardRodgers Creek Fault System Using the USGS 3D Seismic Velocity Model and Realistic Pseudodynamics Ruptures”. Work for this project involved three-dimensional (3D) simulations of ground motions for Hayward Fault (HF) earthquakes. We modeled moderate events on the HF and used them to evaluate the USGS 3D model of the San Francisco Bay Area. We also contributed to ground motions modeling effort for a large suite of scenario earthquakes on the HF. Results were presented at conferences (see appendix) and in one peer-reviewed publication (Aagaard et al., 2010).

58 GEOSCIENCES↗

Error analysis of marker-based object localization using a single-plane XRII

The role of imaging and image guidance is increasing in surgery and therapy, including treatment planning and follow-up. Fluoroscopy is used for two-dimensional (2D) guidance or localization; however, many procedures would benefit from three-dimensional (3D) guidance or localization. Three-dimensional computed tomography (CT) using a C-arm mounted x-ray image intensifier (XRII) can provide high-quality 3D images; however, patient dose and the required acquisition time restrict the number of 3D images that can be obtained. C-arm based 3D CT is therefore limited in applications for x-ray based image guidance or dynamic evaluations. 2D-3D model-based registration, using a single-plane 2D digital radiographic system, does allow for rapid 3D localization. It is our goal to investigate - over a clinically practical range - the impact of x-ray exposure on the resulting range of 3D localization precision. In this paper it is assumed that the tracked instrument incorporates a rigidly attached 3D object with a known configuration of markers. A 2D image is obtained by a digital fluoroscopic x-ray system and corrected for XRII distortions ({+-}0.035 mm) and mechanical C-arm shift ({+-}0.080 mm). A least-square projection-Procrustes analysis is then used to calculate the 3D position using the measured 2D marker locations. The effect of x-ray exposure on the precision of 2D marker localization and on 3D object localization was investigated using numerical simulations and x-ray experiments. The results show a nearly linear relationship between 2D marker localization precision and the 3D localization precision. However, a significant amplification of error, nonuniformly distributed among the three major axes, occurs, and that is demonstrated. To obtain a 3D localization error of less than {+-}1.0 mm for an object with 20 mm marker spacing, the 2D localization precision must be better than {+-}0.07 mm. This requirement was met for all investigated nominal x-ray exposures at 28 cm FOV, and for all but the lowest two at 40 cm FOV. However, even for those two nominal exposures, the expected 3D localization error is less than {+-}1.2 mm. The tracking precision was {+-}0.65 mm for the out-of-plane translations, {+-}0.05 mm for in-plane translations, and {+-}0.05 deg. for the rotations. The root mean square (RMS) difference between the true and projection-Procrustes calculated location was 1.07 mm. It is believed these results show the potential of this technique for dynamic evaluations or real-time image guidance using a single x-ray source and XRII detector.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Technical Review of the CENWP Computational Fluid Dynamics Model of the John Day Dam Forebay

The US Army Corps of Engineers Portland District (CENWP) has developed a computational fluid dynamics (CFD) model of the John Day forebay on the Columbia River to aid in the development and design of alternatives to improve juvenile salmon passage at the John Day Project. At the request of CENWP, Pacific Northwest National Laboratory (PNNL) Hydrology Group has conducted a technical review of CENWP's CFD model run in CFD solver software, STAR-CD. PNNL has extensive experience developing and applying 3D CFD models run in STAR-CD for Columbia River hydroelectric projects. The John Day forebay model developed by CENWP is adequately configured and validated. The model is ready for use simulating forebay hydraulics for structural and operational alternatives. The approach and method are sound, however CENWP has identified some improvements that need to be made for future models and for modifications to this existing model.

54 ENVIRONMENTAL SCIENCES↗

pCalc User's Manual

pCalc is a software tool that computes travel-time predictions, ray path geometry and model queries. This software has a rich set of features, including the ability to use custom 3D velocity models to compute predictions using a variety of geometries. The pCalc software is especially useful for research related to seismic monitoring applications. The pCalc software is available on the web at: www.sandia.gov/salsa3d/Software.html The software is packaged with this user's manual and a set of example datasets, the use of which is described in this manual.

97 MATHEMATICS AND COMPUTING↗

PCalc User's Manual

PCalc is a software tool that computes travel-time predictions, ray path geometry and model queries. This software has a rich set of features, including the ability to use custom 3D velocity models to compute predictions using a variety of geometries. The PCalc software is especially useful for research related to seismic monitoring applications.

58 GEOSCIENCES↗

Developing regionalized models of lithospheric thickness and velocity structure across Eurasia and the Middle East from jointly inverting P-wave and S-wave receiver functions with Rayleigh wave group and phase velocities

In this project, we are developing models of lithospheric structure for a wide variety of tectonic regions throughout Eurasia and the Middle East by regionalizing 1D velocity models obtained by jointly inverting P-wave and S-wave receiver functions with Rayleigh wave group and phase velocities. We expect the regionalized velocity models will improve our ability to predict travel-times for local and regional phases, such as Pg, Pn, Sn and Lg, as well as travel-times for body-waves at upper mantle triplication distances in both seismic and aseismic regions of Eurasia and the Middle East. We anticipate the models will help inform and strengthen ongoing and future efforts within the NNSA labs to develop 3D velocity models for Eurasia and the Middle East, and will assist in obtaining model-based predictions where no empirical data are available and for improving locations from sparse networks using kriging. The codes needed to conduct the joint inversion of P-wave receiver functions (PRFs), S-wave receiver functions (SRFs), and dispersion velocities have already been assembled as part of ongoing research on lithospheric structure in Africa. The methodology has been tested with synthetic 'data' and case studies have been investigated with data collected at an open broadband stations in South Africa. PRFs constrain the size and S-P travel-time of seismic discontinuities in the crust and uppermost mantle, SRFs constrain the size and P-S travel-time of the lithosphere-asthenosphere boundary, and dispersion velocities constrain average S-wave velocity within frequency-dependent depth-ranges. Preliminary results show that the combination yields integrated 1D velocity models local to the recording station, where the discontinuities constrained by the receiver functions are superimposed to a background velocity model constrained by the dispersion velocities. In our first year of this project we will (i) generate 1D velocity models for open broadband seismic stations in the western half of the study area (Eurasia and the Middle East) and (ii) identify well located seismic events with event-station paths isolated to individual tectonic provinces within the study area and collect broadband waveforms and source parameters for the selected events. The 1D models obtained from the joint inversion will then be combined with published geologic terrain maps to produce regionalized models for distinctive tectonic areas within the study area, and the models will be validated through full waveform modeling of well-located seismic events recorded at local and regional distances.

58 GEOSCIENCES↗

Precision bootstrap for the $\mathcal{N}$ = 1 super-Ising model

In this note we report an improved determination of the scaling dimensions and OPE coefficients of the minimal supersymmetric extension of the 3d Ising model using the conformal bootstrap. We also show how this data can be used as input to the Lorentzian inversion formula, finding good agreement between analytic calculations and numerical extremal spectra once mixing effects are resolved.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Real-time simulation of dynamically deformable finite element models using modal analysis and spectral Lanczos decomposition methods

We present two efficient methods for simulating real-time behavior of a dynamically deformable 3D object modeled by finite element equations. The first method is based on modal analysis, which uses the most significant vibration modes of the object to compute the deformations in real-time for applied forces. The second method uses the spectral Lanczos decomposition to obtain the explicit solutions of the finite element equations.

medical↗

Synthesis, Spectra, and Theoretical Investigations of 1,3,5-Triazines Compounds as Ultraviolet Rays Absorber Based on Time-Dependent Density Functional Calculations and three-Dimensional Quantitative Structure-Property Relationship

A series of 1,3,5-triazines were synthesized and their UV absorption properties were tested. The computational chemistry methods were used to construct quantitative structure-property relationship (QSPR), which was used to computer aided design of new 1,3,5-triazines ultraviolet rays absorber compounds. The experimental UV absorption data are in good agreement with those predicted data using the Time-dependent density functional theory (TD-DFT) [B3LYP/6–311 + G(d,p)]. A suitable forecasting model (R > 0.8, P < 0.0001) was revealed. Predictive three-dimensional quantitative structure-property relationship (3D-QSPR) model was established using multifit molecular alignment rule of Sybyl program, which conclusion is consistent with the TD-DFT calculation. The exceptional photostability mechanism of such ultraviolet rays absorber compounds was studied and confirmed as principally banked upon their ability to undergo excited-state deactivation via an ultrafast excited-state proton transfer (ESIPT). The intramolecular hydrogen bond (IMHB) of 1,3,5-triazines compounds is the basis for the excited state proton transfer, which was explored by IR spectroscopy, UV spectra, structural and energetic aspects of different conformers and frontier molecular orbitals analysis.

74 ATOMIC AND MOLECULAR PHYSICS↗

Revealing the unusual rate-dependent mechanical behaviors of nematic liquid crystal elastomers

Liquid crystal elastomers (LCEs) exhibit unique mechanical properties of soft elasticity and enhanced energy dissipation with rate dependency. They are potentially transformative materials for applications in mechanical impact mitigation and vibration isolation. However, previous studies have primarily focused on the mechanics of LCEs under equilibrium and quasistatic loading conditions. Critical knowledge gaps exist in understanding their rate-dependent behaviors, which are a complex mixture of traditional network viscoelasticity and the soft elastic behaviors with changes in the mesogen orientation and order parameter. Together, these inelastic mechanisms lead to unusual rate-dependent energy absorption responses of LCEs. In this work, we developed a viscoelastic constitutive theory for monodomain nematic LCEs to investigate how multiple underlying sources of inelasticity manifest in the rate-dependent and dissipative behaviors of monodomain LCEs. Here, the theoretical modeling framework combines the neo-classical network theory with evolution rules for the mesogen orientation and order parameter with conventional viscoelasticity. The model is calibrated with uniaxial tension and compression data spanning six decades of strain rates. The established 3D constitutive model enables general loading predictions taking the initial mesogen orientation and order parameter as inputs. Additionally, parametric studies were performed to further understand the rate dependence of monodomain LCEs in relation to their energy absorption characteristics. Based on the parametric studies, particularly loading scenarios are identified as conditions where LCEs outperform conventional elastomers regarding energy absorption.

42 ENGINEERING↗

MO-DE-202-00: Image-Guided Interventions: Advances in Intraoperative Imaging, Guidance, and An Emerging Role for Medical Physics in Surgery

At least three major trends in surgical intervention have emerged over the last decade: a move toward more minimally invasive (or non-invasive) approach to the surgical target; the development of high-precision treatment delivery techniques; and the increasing role of multi-modality intraoperative imaging in support of such procedures. This symposium includes invited presentations on recent advances in each of these areas and the emerging role for medical physics research in the development and translation of high-precision interventional techniques. The four speakers are: Keyvan Farahani, “Image-guided focused ultrasound surgery and therapy” Jeffrey H. Siewerdsen, “Advances in image registration and reconstruction for image-guided neurosurgery” Tina Kapur, “Image-guided surgery and interventions in the advanced multimodality image-guided operating (AMIGO) suite” Raj Shekhar, “Multimodality image-guided interventions: Multimodality for the rest of us” Learning Objectives: Understand the principles and applications of HIFU in surgical ablation. Learn about recent advances in 3D–2D and 3D deformable image registration in support of surgical safety and precision. Learn about recent advances in model-based 3D image reconstruction in application to intraoperative 3D imaging. Understand the multi-modality imaging technologies and clinical applications investigated in the AMIGO suite. Understand the emerging need and techniques to implement multi-modality image guidance in surgical applications such as neurosurgery, orthopaedic surgery, vascular surgery, and interventional radiology. Research supported by the NIH and Siemens Healthcare.; J. Siewerdsen; Grant Support - National Institutes of Health; Grant Support - Siemens Healthcare; Grant Support - Carestream Health; Advisory Board - Carestream Health; Licensing Agreement - Carestream Health; Licensing Agreement - Elekta Oncology.; T. Kapur, P41EB015898; R. Shekhar, Funding: R42CA137886 and R41CA192504 Disclosure and CoI: IGI Technologies, small-business partner on the grants.

61 RADIATION PROTECTION AND DOSIMETRY↗

MO-DE-202-01: Image-Guided Focused Ultrasound Surgery and Therapy

At least three major trends in surgical intervention have emerged over the last decade: a move toward more minimally invasive (or non-invasive) approach to the surgical target; the development of high-precision treatment delivery techniques; and the increasing role of multi-modality intraoperative imaging in support of such procedures. This symposium includes invited presentations on recent advances in each of these areas and the emerging role for medical physics research in the development and translation of high-precision interventional techniques. The four speakers are: Keyvan Farahani, “Image-guided focused ultrasound surgery and therapy” Jeffrey H. Siewerdsen, “Advances in image registration and reconstruction for image-guided neurosurgery” Tina Kapur, “Image-guided surgery and interventions in the advanced multimodality image-guided operating (AMIGO) suite” Raj Shekhar, “Multimodality image-guided interventions: Multimodality for the rest of us” Learning Objectives: Understand the principles and applications of HIFU in surgical ablation. Learn about recent advances in 3D–2D and 3D deformable image registration in support of surgical safety and precision. Learn about recent advances in model-based 3D image reconstruction in application to intraoperative 3D imaging. Understand the multi-modality imaging technologies and clinical applications investigated in the AMIGO suite. Understand the emerging need and techniques to implement multi-modality image guidance in surgical applications such as neurosurgery, orthopaedic surgery, vascular surgery, and interventional radiology. Research supported by the NIH and Siemens Healthcare.; J. Siewerdsen; Grant Support - National Institutes of Health; Grant Support - Siemens Healthcare; Grant Support - Carestream Health; Advisory Board - Carestream Health; Licensing Agreement - Carestream Health; Licensing Agreement - Elekta Oncology.; T. Kapur, P41EB015898; R. Shekhar, Funding: R42CA137886 and R41CA192504 Disclosure and CoI: IGI Technologies, small-business partner on the grants.

60 APPLIED LIFE SCIENCES↗

MO-DE-202-02: Advances in Image Registration and Reconstruction for Image-Guided Neurosurgery

At least three major trends in surgical intervention have emerged over the last decade: a move toward more minimally invasive (or non-invasive) approach to the surgical target; the development of high-precision treatment delivery techniques; and the increasing role of multi-modality intraoperative imaging in support of such procedures. This symposium includes invited presentations on recent advances in each of these areas and the emerging role for medical physics research in the development and translation of high-precision interventional techniques. The four speakers are: Keyvan Farahani, “Image-guided focused ultrasound surgery and therapy” Jeffrey H. Siewerdsen, “Advances in image registration and reconstruction for image-guided neurosurgery” Tina Kapur, “Image-guided surgery and interventions in the advanced multimodality image-guided operating (AMIGO) suite” Raj Shekhar, “Multimodality image-guided interventions: Multimodality for the rest of us” Learning Objectives: Understand the principles and applications of HIFU in surgical ablation. Learn about recent advances in 3D–2D and 3D deformable image registration in support of surgical safety and precision. Learn about recent advances in model-based 3D image reconstruction in application to intraoperative 3D imaging. Understand the multi-modality imaging technologies and clinical applications investigated in the AMIGO suite. Understand the emerging need and techniques to implement multi-modality image guidance in surgical applications such as neurosurgery, orthopaedic surgery, vascular surgery, and interventional radiology. Research supported by the NIH and Siemens Healthcare.; J. Siewerdsen; Grant Support - National Institutes of Health; Grant Support - Siemens Healthcare; Grant Support - Carestream Health; Advisory Board - Carestream Health; Licensing Agreement - Carestream Health; Licensing Agreement - Elekta Oncology.; T. Kapur, P41EB015898; R. Shekhar, Funding: R42CA137886 and R41CA192504 Disclosure and CoI: IGI Technologies, small-business partner on the grants.

60 APPLIED LIFE SCIENCES↗

MO-DE-202-03: Image-Guided Surgery and Interventions in the Advanced Multimodality Image-Guided Operating (AMIGO) Suite

At least three major trends in surgical intervention have emerged over the last decade: a move toward more minimally invasive (or non-invasive) approach to the surgical target; the development of high-precision treatment delivery techniques; and the increasing role of multi-modality intraoperative imaging in support of such procedures. This symposium includes invited presentations on recent advances in each of these areas and the emerging role for medical physics research in the development and translation of high-precision interventional techniques. The four speakers are: Keyvan Farahani, “Image-guided focused ultrasound surgery and therapy” Jeffrey H. Siewerdsen, “Advances in image registration and reconstruction for image-guided neurosurgery” Tina Kapur, “Image-guided surgery and interventions in the advanced multimodality image-guided operating (AMIGO) suite” Raj Shekhar, “Multimodality image-guided interventions: Multimodality for the rest of us” Learning Objectives: Understand the principles and applications of HIFU in surgical ablation. Learn about recent advances in 3D–2D and 3D deformable image registration in support of surgical safety and precision. Learn about recent advances in model-based 3D image reconstruction in application to intraoperative 3D imaging. Understand the multi-modality imaging technologies and clinical applications investigated in the AMIGO suite. Understand the emerging need and techniques to implement multi-modality image guidance in surgical applications such as neurosurgery, orthopaedic surgery, vascular surgery, and interventional radiology. Research supported by the NIH and Siemens Healthcare.; J. Siewerdsen; Grant Support - National Institutes of Health; Grant Support - Siemens Healthcare; Grant Support - Carestream Health; Advisory Board - Carestream Health; Licensing Agreement - Carestream Health; Licensing Agreement - Elekta Oncology.; T. Kapur, P41EB015898; R. Shekhar, Funding: R42CA137886 and R41CA192504 Disclosure and CoI: IGI Technologies, small-business partner on the grants.

60 APPLIED LIFE SCIENCES↗

MO-DE-202-04: Multimodality Image-Guided Surgery and Intervention: For the Rest of Us

At least three major trends in surgical intervention have emerged over the last decade: a move toward more minimally invasive (or non-invasive) approach to the surgical target; the development of high-precision treatment delivery techniques; and the increasing role of multi-modality intraoperative imaging in support of such procedures. This symposium includes invited presentations on recent advances in each of these areas and the emerging role for medical physics research in the development and translation of high-precision interventional techniques. The four speakers are: Keyvan Farahani, “Image-guided focused ultrasound surgery and therapy” Jeffrey H. Siewerdsen, “Advances in image registration and reconstruction for image-guided neurosurgery” Tina Kapur, “Image-guided surgery and interventions in the advanced multimodality image-guided operating (AMIGO) suite” Raj Shekhar, “Multimodality image-guided interventions: Multimodality for the rest of us” Learning Objectives: Understand the principles and applications of HIFU in surgical ablation. Learn about recent advances in 3D–2D and 3D deformable image registration in support of surgical safety and precision. Learn about recent advances in model-based 3D image reconstruction in application to intraoperative 3D imaging. Understand the multi-modality imaging technologies and clinical applications investigated in the AMIGO suite. Understand the emerging need and techniques to implement multi-modality image guidance in surgical applications such as neurosurgery, orthopaedic surgery, vascular surgery, and interventional radiology. Research supported by the NIH and Siemens Healthcare.; J. Siewerdsen; Grant Support - National Institutes of Health; Grant Support - Siemens Healthcare; Grant Support - Carestream Health; Advisory Board - Carestream Health; Licensing Agreement - Carestream Health; Licensing Agreement - Elekta Oncology.; T. Kapur, P41EB015898; R. Shekhar, Funding: R42CA137886 and R41CA192504 Disclosure and CoI: IGI Technologies, small-business partner on the grants.

60 APPLIED LIFE SCIENCES↗

Report From BPTCS Project Team On Evaluation Of Additive Manufacturing For Pressure Retaining Equipment

ASME is evaluating the use of additive manufacturing (AM) for the construction of pressure equipment. The information in this report assesses available AM technologies for direct metal fabrication of pressure equipment. Background information is included in the report to provide context for those not experienced in AM technology. Only commercially available technologies for direct metal fabrication are addressed in the report because these AM methods are the only viable approaches for the construction of pressure equipment. Metal AM technologies can produce near-net shape parts by using multiple layers of material from a three dimensional (3D) design model of the geometry. Additive manufacturing of metal components was developed from polymer based rapid prototyping or 3D printing. At the current maturity level, AM application for pressure equipment has the potential to reduce delivery times and costs for complex shapes. AM will also lead to a reduction in the use of high cost materials, since parts can be created with corrosion resistant layers of high alloy material and structural layers of lower cost materials.

42 ENGINEERING↗