Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “vacuum electronics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,387 records · Page 77

Liquid-Phase Surface Alloying of Copper with Stainless Steel Using Low-Energy, High-Current Electron Beam

The paper deals with the formation of the stainless steel-copper surface alloy which occurs during the single vacuum cycle. Deposition of the stainless steel film onto a copper substrate is performed via successive magnetron sputtering followed by its liquid-phase mixing with copper using the low-energy, high-current electron beam of microsecond length. Numerical calculations are used to identify the optimum irradiation modes for the surface alloying. It is found that the optimum irradiation modes provide the homogeneous surface alloying, and the copper concentration in the obtained layer increases with the increase in energy density of the low-energy, high-current electron beam. The formation of the stainless steel-copper surface alloy increases the wear resistance of copper specimens by 7.5 times as compared to the original specimens. In addition, it is ascertained that the wear resistance of the surface alloy exceeds that of the common film coating (1 μm) more than 5 times.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Nanowire growth kinetics in aberration corrected environmental transmission electron microscopy

Here, we visualize atomic level dynamics during Si nanowire growth using aberration corrected environmental transmission electron microscopy, and compare with lower pressure results from ultra-high vacuum microscopy. We discuss the importance of higher pressure observations for understanding growth mechanisms and describe protocols to minimize effects of the higher pressure background gas.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Nonevaporable getter coating chambers for extreme high vacuum

Techniques for NEG coating a large diameter chamber are presented along with vacuum measurements in the chamber using several pumping configurations, with base pressure as low as 1.56x10^-12 Torr (N2 equivalent) with only a NEG coating and small ion pump. We then describe modifications to the NEG coating process to coat complex geometry chambers for ultra-cold atom trap experiments. Surface analysis of NEG coated samples are used to measure composition and morphology of the thin films. Finally, pressure measurements are compared for two NEG coated polarized electron source chambers: the 130 kV polarized electron source at Jefferson Lab and the upgraded 350 kV polarized 2 electron source, both of which are approaching or within the extreme high vacuum (XHV) range, defined as P<7.5x10^-13 Torr.

47 OTHER INSTRUMENTATION↗

Spontaneous multi-keV electron generation in a low-RF-power axisymmetric mirror machine

Title:Spontaneous multi-keV electron generation in a low-RF-power axisymmetric mirror machineAbstract:X-ray emission shows the existence of multi-keV electrons in low-temperature, low-power, capacitively-coupled RF-heated magnetic-mirror plasmas that also contain a warm (300 eV) minority electron population. Though these warm electrons are initially passing particles, we suggest that collisionless scattering -- mu non-conservation in the static vacuum field -- is responsible for a minority of them to persist in the mirror cell for thousands of transits during which time a fraction are energized to a characteristic temperature of 3 keV, with some electrons reaching energies above 30 keV. A heuristic model of the heating by a Fermi-acceleration-like mechanism is presented, with mu non-conservation in the static vacuum field as an essential feature.

Swanson, C↗

Three-axis electron-beam test facility

An electron beam test facility, which consists of a precision multidimensional manipulator built into an ultra-high-vacuum bell jar, was designed, fabricated, and operated at Lewis Research Center. The position within the bell jar of a Faraday cup which samples current in the electron beam under test, is controlled by the manipulator. Three orthogonal axes of motion are controlled by stepping motors driven by digital indexers, and the positions are displayed on electronic totalizers. In the transverse directions, the limits of travel are approximately + or - 2.5 cm from the center with a precision of 2.54 micron (0.0001 in.); in the axial direction, approximately 15.0 cm of travel are permitted with an accuracy of 12.7 micron (0.0005 in.). In addition, two manually operated motions are provided, the pitch and yaw of the Faraday cup with respect to the electron beam can be adjusted to within a few degrees. The current is sensed by pulse transformers and the data are processed by a dual channel box car averager with a digital output. The beam tester can be operated manually or it can be programmed for automated operation. In the automated mode, the beam tester is controlled by a microcomputer (installed at the test site) which communicates with a minicomputer at the central computing facility. The data are recorded and later processed by computer to obtain the desired graphical presentations.

Dayton, J. A., Jr.↗

A Study of the Activated GaAs Surface for Application as an Electron Source in Particle Accelerators

The use of type III-V semiconductor materials as photocathodes has in recent years become a focus for the High Energy Physics community. Once activated to a negative electron affinity (NEA) state and illuminated by a laser, these materials can be used as a high-brightness source of both polarised and un-polarised electrons in some modern accelerators, for example, ALICE (Accelerators and Lasers in Combined Experiments) at Daresbury Laboratory. This paper will focus on the use of gallium arsenide (GaAs) as a photocathode, and detail the reconfiguration and re-commissioning of two vacuum systems that support standard surface science techniques such as ultraviolet/X-ray photoelectron spectroscopy (UPS/XPS), low energy electron diffraction (LEED) and auger electron spectroscopy (AES). The paper will present details of cleaning GaAs in order to maximise quantum efficiency and will provide evidence from XPS and LEED to demonstrate what is happening at the atomic level.

36 MATERIALS SCIENCE↗

Multimodal imaging of oil-in-water bilgewater emulsion and biofilms

Bilgewater emulsions, consisting of oil and surfactant mixtures in water, affect many aquatic species. Thus development of methods and techniques to treat or mitigate the formation and undesired consequences of shipboard emulsions are urgently needed. This work presents new results of the evolution of the bilgewaer chemical and physical properties using in situ imaging. A Navy O/W emulsion consisting of three oils and a detergent mixture was used as the synthetic bilgewater model [1, 2]. Synthetic oil-in-water (O/W) emulsion droplets were seled in a vacuum compatible microfluidic sample holder and imaged using a suite of tools including scanning electron microscopy (SEM), time-of-flight secondary ion mass spectrometry (ToF-SIMS), confocal laser scanning microscopy, and optical microscopy, highlighting the advantage of multiscale analysis and its applications in waste reduction and treatment in the environment. The transferrable and vacuum compatible microfluidic interface, System for Analysis at the Liquid Vacuum Interface (SALVI), was used in this study. SALVI enabled surface analysis of liquids and liquid-solid interactions using ToF-SIMS and SEM [3, 4]. Its detection window is an aperture of 2 ?m in diameter open to vacuum, permitting direct detection of the liquid surface. Liquid is withheld by surface tension within the aperture. The interface is composed of a silicon nitride membrane and polydimethylsiloxane microchannel [3, 4]. A variety of samples including complex liquid mixtures, ionic liquids, single mammalian cells, live biofilms, and solid-electrolyte interface have been analyzed using in situ imaging [5, 6]. The feasibility of using SALVI for in situ SEM imaging of nanoparticles and colloids in liquid was recently demonstrated [7]. This paper shows new findings of multimodal imaging and analysis of synthesized emulsion particles in water. Figure 1 depicts a schematic of multimodal in situ imaging of bilgewater emulsion using SEM and ToF-SIMS. Furthermore, we study the interactions of microbes and bilgewater emulsion. Microbes play an important role in the ocean. We hypothesize that microbes release organics that can act as surfactants that affect bilgewater formation or weakening. We present the first systematic study of emulsions and biofilms and investigate the effects of biofilms on bilgewater emulsions. Pseudomonas was selected as a model strain. Biofilms were cultured in a microchannel to allow culture [8]. Once a thick layer of biofilms was formed, the medium solution was changed to a mixture consisting of 50 % bilgewater emulsion. Dispersed biofilms were collected at 24 hrs. and 48 hrs. after emulsions were introduced into the channel. Bilgewater emulsions, biofilms, and mixtures of bilgewater emulsions and biofilms were analyzed using multiple in situ and ex situ techniques as described earlier. Our findings indicate that biofilms change the chemical makeup of the emulsion surface compositions and emulsion droplet size distribution, confirming the hypothesis that extracellular polymeric substance (EPS) related components released from biofilms can function as surfactants and change the oil-in-water interfaces.

bilgewater, multimodal imaging, biofilms↗

Monte Carlo simulation of initial breakdown phase for magnetised toroidal ICRF discharges

The radio-frequency (RF) plasma production technique in the ion cyclotron range of frequency (ICRF) attracts growing attention among fusion experts because of its high potential for solving several basic problems of reactor-oriented superconducting fusion machines, such as ICRF wall conditioning in tokamaks and stellarators (T{sub e} = 3−5eV, n{sub e}<10{sup 12}cm{sup −3}), ICRF-assisted tokamak start-up and target plasma production (n{sub e} = 10{sup 13}cm{sup −3}) in stellarators. Plasma initiation by ICRF has been studied intensively using single particle descriptions and basic analytic models. To further improve the present understanding on plasma production employing the vacuum RF field of ICRF antennas in toroidal devices in presence of the toroidal magnetic field, and its parametric dependencies a Monte Carlo code has been developed. The 1D code RFdinity1D describes the motion of electrons, accelerated by the RF field in front of the ICRF antenna, along one toroidal magnetic field line. Dependent on their individual energies and the related electron collision cross sections (ionisation, excitation and dissociation) weighted by a Monte Carlo procedure, an electron avalanche may occur. Breakdown conditions are discussed as function of RF discharge parameters (i) RF vacuum electric field strength, (ii) RF frequency and (iii) neutral pressure (H2). The slope of the exponential density increase, taken as measure for the breakdown speed, shows qualitative agreement to experimental breakdown times as found in literature and experimental data of the ASDEX upgrade and TEXTOR tokamak, and is interpreted by studying the characteristic electron velocity distribution functions.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

High-intensity nanosecond-pulsed laser-induced plasma in air, water, and vacuum: A comparative study of the early-stage evolution using a physics-based predictive model

A comparative study has been performed for properties (temperature, density, and electron Coulomb coupling constant) of plasma induced by high-intensity ({approx}GW/cm{sup 2}) nanosecond laser-metal interactions in air, water, and vacuum. The study is for early-stage (t < or approx. 30 ns) plasma evolution, where the above plasma properties are very difficult to measure experimentally and hence a comparative property study has been rarely reported in literature. In this paper a physics-based predictive model is used as the investigation tool. The model was verified based on experimental measurements for the early-stage plasma pressure and front propagation and the late-stage (t > or approx. 30 ns) plasma temperature and electron number density, which are relatively easy to measure. Therefore, the experimentally verified model can provide reasonably accurate information on the difficult-to-measure plasma temperature and density in the early-stage at least in the semiquantitative sense, and the information will be very useful for the fundamental laser plasma study and relevant laser applications. It has been found that plasma with very different temperatures and densities can be created in different media.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Modular ultrahigh vacuum-compatible gas-injection system with an adjustable gas flow for focused particle beam-induced deposition

A gas-injection system (GIS) heats up a powdery substance and transports the resulting gas through a capillary into a vacuum chamber. Such a system can be used to guide a (metal)organic precursor gas very close to the focal area of an electron or ion beam, where a permanent deposit is created and adheres to the substrate. This process is known as focused particle beam-induced deposition. The authors present design principles and give construction details of a GIS suitable for ultrahigh vacuum usage. The GIS is composed of several self-contained components which can be customized rather independently. It allows for a continuously adjustable gas-flow rate. The GIS was attached to a standard scanning electron microscope (JEOL 6100) and tested with the tungsten precursor W(CO){sub 6}. The analysis of the deposits by means of atomic force microscopy and energy dispersive x-ray spectroscopy provides clear evidence that excellent gas-flow-rate stability and ensuing growth rate and metal-content reproducibility are experienced.

36 MATERIALS SCIENCE↗

Measurements of the Propagation of EM Waves through the Vacuum Chamber of the PEP-II Low Energy Ring for Beam Diagnostics

We present the results of our measurements of the electron cloud density in the PEP-II low energy ring (LER) by propagating a TE wave into the beam pipe. By connecting a signal generator to a beam position monitor button we can excite a signal above the vacuum chamber cut-off frequency and measure its propagation through the beam pipe with a spectrum analyzer connected to another button about 50 meters away. The measurement can be performed with different beam conditions and also at different settings of the solenoids used to reduce the build up of electrons. The presence of a modulation in the TE wave transmission, synchronous with the beam revolution frequency, which appear to increase in depth when the solenoids are switched off, seem to be directly correlated to the electron cloud density in the region between the two BPM's. In this paper we present and discuss the measurements taken in the Interaction Region 12 straight of the LER during 2006 and the first part of 2007.

43 PARTICLE ACCELERATORS↗

Observations of electron beam structure in space experiments

Observations of a 100-mA, 1-keV electron beam were made with a low light level TV system and other instruments aboard the space shuttle STS 3 in March 1982. When fired at a moderate pitch angle with respect to the magnetic field, the beam electrons initially moved outward along a classical helical trajectory. Within a short distance, however, the beam electrons were deflected away from the helical trajectory into paths parallel to magnetic field lines threading the primary helix. This resulted in the formation of a thin-walled, cylindrical electron beam structure having a radius equal to the primary beam gyroradius. This structure, which is consistent with earlier laboratory vacuum chamber observations and recent two-dimensional computer electrostatic plasma simulations, has important implications for determining the extent to which pulsed electron beams can radiate electromagnetic energy in the ionosphere.

Banks, Peter M.↗

Simulation study of a 'fission electron-collection' neutron detector

In this work, a 'fission electron-collection' neutron detector was studied using the Monte Carlo method. The detector consists of two metal electrodes mounted in a vacuum, named coated and collection electrodes, respectively. The first electrode is coated with triuranium octoxide. The detector uses the 'fission electron-collection' technique, which does not need an intermediate material but directly collects electrons from the coating. Such a detector can realize a flat energy response and a fast time response, both of which are important in the fluence measurement of pulsed neutron sources. In this paper, the physical processes of detection are presented, as well as Monte Carlo simulation studies using the Geant4 toolkit. From the results, the sensitivity of the detector is approximately 1.5 x 10{sup -21} [C/(n/cm{sup 2})], and the FWHM of response function is 2.5 nanoseconds. Additionally, the characterization of escaping electrons is also presented, and the sensitivity of the detector is determined for various coating thicknesses. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Observation of Plasmon Energy Gain for Emitted Secondary Electron in Vacuo

Plasmon gain by core-level electrons or elastic electrons observed in past studies seems to be of no practical value in material characterization, mainly because of their ultralow signal intensities. Nevertheless, in the emission spectra of Au samples, we have observed plasmon gain in secondary electrons. Here, the electrons gain energy from surface plasmons after escaping from the surface and thereby only carry surface-plasmon information in the vacuum above the surface. Because the intensity of the emitted SEs is strong, rivaling that of core-level or elastic electrons, the observed phenomenon has in practice the potential to image directly in space the surface plasmon near but exterior to the metal surface.

36 MATERIALS SCIENCE↗

Effect of Sn Doping on the Crystallization Kinetics of Amorphous TlInS{sub 2} Films

The crystallization of amorphous Sn-doped TlInS{sub 2} films into three polymorphs has been studied by kinematic electron diffraction. The results demonstrate that the crystallization of 30-nm-thick amorphous films produced by thermal evaporation in high vacuum can be described by the Avrami–Kolmogorov equation: V{sub τ} = V{sub 0}[1–exp(–kτ{sup m})]. Kinematic electron diffraction patterns of the TlIn{sub 1–х}Sn{sub x}S{sub 2} films have been used to assess the effect of doping with Sn on the growth dimensionality and the activation energy for the crystallization of the amorphous films and the unit-cell parameters of the resultant crystalline materials. Doping extends the temperature range and effective activation energy for the crystallization of the amorphous films.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Efficient solar cells by space processing

Thin films of electron beam evaporated silicon were deposited on molybdenum, tantalum, tungsten and molybdenum disilicide under ultrahigh vacuum conditions. Mass spectra from a quadrapole residual gas analyzer were used to determine the partial pressure of 13 residual gases during each processing step. Surface contamination and interdiffusion were monitored by in situ Auger electron spectrometry. The presence of phosphorus in the silicon was responsible for attaining elevated temperatures with silicide formations. Heteroepitaxial silicon growth was sensitive to the presence of oxygen during deposition, the rate and length of deposition as well as the substrate orientation.

Schmidt, F. A.↗