Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “studies”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,387 records · Page 77

A combined experimental and computational study of water-gas shift reaction over rod-shaped Ce 0.75 M 0.25 O 2 (M=Ti, Zr, and Mn) supported Cu catalysts

Water-gas shift (WGS) reaction over a series of ceria-based mixed oxides supported Cu catalysts was investigated using a combined experimental and theoretical method. The mixed rod-shaped Ce 0.75 M 0.25 O 2 (M = Ti 4+ , Zr 4+ , Mn 4+ ) solid solutions, which majorly expose the (110) and (100) facets, are synthesized by hydrothermal method and used to prepare supported Cu catalysts. We found that the Cu/Ce0.75Ti 0.25 O 2 (Cu-CT) exhibits the highest CO conversion in the temperature range of 150-250 °C among all supported Cu catalysts. This is mainly attributed to (i) good dispersion of Cu; (ii) largest amount of moderate copper oxide; and (iii) strongest Cu-support interaction of Cu-CT. And compared to other mixed metals, periodic density functional theory calculations performed, this work further suggest that the introduction of Ti into CeO 2 not only promotes oxygen vacancy formation and CO adsorption, but also facilitates the carboxyl (COOH) formation at the interface of the Cu cluster and the support, which leads to the enhanced catalytic activity of the Cu-CT toward WGS reaction.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

An algorithm to correct saturated mass spectrometry ion abundances for enhanced quantitation and mass accuracy in omic studies

The mass accuracy and peak intensity of ions detected by mass spectrometry (MS) measurements are essential to facilitate compound identification and quantitation. However, high concentration species can easily cause problems if their ion intensities reach beyond the limits of the detection system, leading to distorted and non-ideal detector response (e.g. saturation), and largely precluding the calculation of accurate m/z and intensity values. Here we present an open source computational method to correct peaks above a defined intensity (saturated) threshold determined by the MS instrumentation such as the analog-to-digital converters or time-to-digital converters used in conjunction with time-of-flight MS. In this method, the isotopic envelope for each observed ion above the saturation threshold is compared to its expected theoretical isotopic distribution. The most intense isotopic peak for which saturation does not occur is then utilized to re-calculate the precursor m/z and correct the intensity, resulting in both higher mass accuracy and greater dynamic range. The benefits of this approach were evaluated with proteomic and lipidomic datasets of varying complexities. After correcting the high concentration species, reduced mass errors and enhanced dynamic range were observed for both simple and complex omic samples. Specifically, the mass error dropped by more than 50% in most cases with highly saturated species and dynamic range increased by 1-2 orders of magnitude for peptides in a blood serum sample.

Environmental Molecular Sciences Laboratory↗

A Phase II Study of Synchronous Three-Dimensional Conformal Boost to the Gross Tumor Volume for Patients With Unresectable Stage III Non-Small-Cell Lung Cancer: Results of Korean Radiation Oncology Group 0301 Study

Purpose: We evaluated the efficacy of synchronous three-dimensional (3D) conformal boost to the gross tumor volume (GTV) in concurrent chemoradiotherapy for patients with locally advanced non-small-cell lung cancer (NSCLC). Methods and Materials: Eligibility included unresectable Stage III NSCLC with no pleural effusion, no supraclavicular nodal metastases, and Eastern Cooperative Oncology Group performance score of 0-1. Forty-nine patients with pathologically proven NSCLC were enrolled. Eighteen patients had Stage IIIA and 31 had Stage IIIB. By using 3D conformal radiotherapy (RT) techniques, a dose of 1.8 Gy was delivered to the planning target volume with a synchronous boost of 0.6 Gy to the GTV, with a total dose of 60 Gy to the GTV and 45 Gy to the planning target volume in 25 fractions during 5 weeks. All patients received weekly chemotherapy consisting of paclitaxel and carboplatin during RT. Results: With a median follow-up of 36.8 months (range, 29.0-45.5 months) for surviving patients, median survival was 28.1 months. One-, 2- and 3-year overall survival rates were 77%, 56.4%, and 43.8%, respectively. Corresponding local progression-free survival rates were 71.2%, 53.7%, and 53.7%. Compliance was 90% for RT and 88% for chemotherapy. Acute esophagitis of Grade 2 or higher occurred in 29 patients. Two patients with T4 lesions died of massive bleeding and hemoptysis during treatment (Grade 5). Overall late toxicity was acceptable. Conclusions: Based on the favorable outcome with acceptable toxicity, the acceleration scheme using 3D conformal GTV boost in this trial is warranted to compare with conventional fractionation in a Phase III trial.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

NRG Oncology–Radiation Therapy Oncology Group Study 1014: 1-Year Toxicity Report From a Phase 2 Study of Repeat Breast-Preserving Surgery and 3-Dimensional Conformal Partial-Breast Reirradiation for In-Breast Recurrence

Purpose: To determine the associated toxicity, tolerance, and safety of partial-breast reirradiation. Methods and Materials: Eligibility criteria included in-breast recurrence occurring >1 year after whole-breast irradiation, <3 cm, unifocal, and resected with negative margins. Partial-breast reirradiation was targeted to the surgical cavity plus 1.5 cm; a prescription dose of 45 Gy in 1.5 Gy twice daily for 30 treatments was used. The primary objective was to evaluate the rate of grade ≥3 treatment-related skin, fibrosis, and/or breast pain adverse events (AEs), occurring ≤1 year from re-treatment completion. A rate of ≥13% for these AEs in a cohort of 55 patients was determined to be unacceptable (86% power, 1-sided α = 0.07). Results: Between 2010 and 2013, 65 patients were accrued, and the first 55 eligible and with 1 year follow-up were analyzed. Median age was 68 years. Twenty-two patients had ductal carcinoma in situ, and 33 had invasive disease: 19 ≤1 cm, 13 >1 to ≤2 cm, and 1 >2 cm. All patients were clinically node negative. Systemic therapy was delivered in 51%. All treatment plans underwent quality review for contouring accuracy and dosimetric compliance. All treatment plans scored acceptable for tumor volume contouring and tumor volume dose-volume analysis. Only 4 (7%) scored unacceptable for organs at risk contouring and organs at risk dose-volume analysis. Treatment-related skin, fibrosis, and/or breast pain AEs were recorded as grade 1 in 64% and grade 2 in 7%, with only 1 (<2%) grade ≥3 and identified as grade 3 fibrosis of deep connective tissue. Conclusion: Partial-breast reirradiation with 3-dimensional conformal radiation therapy after second lumpectomy for patients experiencing in-breast failures after whole-breast irradiation is safe and feasible, with acceptable treatment quality achieved. Skin, fibrosis, and breast pain toxicity was acceptable, and grade 3 toxicity was rare.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Route Optimization for Energy Efficient Airport Shuttle Operations - A Case Study from Dallas Fort Worth International Airport

Air travel and requisite surface traffic supporting passenger arrival/departure constitutes a significant portion of travel and emissions in cities with large airports. An airport trip can segment into three parts namely: i) travel from a location in the city to the airport; ii) travel from a parking lot or rental car center to the terminal (i.e., within the airport premises), and iii) travel inside the terminal. Depending on the airport access mode all or a part of these legs comprise a traveler’s journey to the airport. The priority of airport ground transport management teams is to provide passengers with a seamless travel experience within the airport, so it is understandable that within airport shuttle routes might not be optimized for minimizing energy consumption. Solutions that meet the dual objective of reducing energy consumption from airport shuttle operations without compromising on passenger travel experience are key to improving system efficiency. There is currently a dearth of research and tools that can inform airports in making such decisions. Addressing this need, this research effort puts forth an optimization model that generates optimal shuttle routes for a given set of constraints, and a discrete-event simulator that evaluates the optimal solutions in a stochastic environment to understand the tradeoffs between passenger wait times, and within airport shuttle energy consumption. The proposed set of tools are tested in the context of optimizing airport shuttles routes within the Dallas Fort Worth International Airport (DFW). In addition to shuttle spatial positioning, and passenger demand information, high-fidelity vehicle data was collected using data loggers installed on DFW shuttles. Results show that 20% energy reduction in shuttle operations is possible with a modest two-minute increase in average passenger wait times. The tools developed in this research effort are designed to be generalizable and can help optimize shuttle operations planning at any major airport.

air travel↗