Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “storage”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,387 records · Page 77

Optimal economic dispatch policy for prosumer with energy storage considering self-consumption demand

This paper analyzed the effects of self-consumption demand on the joint economic dispatch of prosumers (energy consumers who are also producers), particularly for prosumers with both energy storage and distributed energy sources (DERs). Studies in the existing literature on the economic dispatch scheduling policy of energy storage, mostly from the perspective of electricity merchants, do not address the impacts of self-consumption demand. However, due to the intermittent and high levels of uncertainty regarding DERs generation and the dynamic demand of the prosumer, production and consumption are not always simultaneous; there are two possible scenarios in each period depending on whether DERs generation can meet prosumers' self-consumption or not. Incorporating the self-consumption demand will pose modeling challenges since these two scenarios cannot occur simultaneously in each period, and different scenarios require different decisions for prosumers. Further, this paper analyzed the two scenarios separately to find the optimal storage scheduling strategy, and the results were combined to get the optimal global solution. We focused on prosumers' economic decision-making while considering self-consumption demand and the physical constraints of a battery based on dynamic programming. Our study showed that the feasible state of charge (SOC) range of storage can be segmented into several sub-ranges by SOC reference points under the above two scenarios. As a result, a prosumer's optimal scheduling can be uniquely and conveniently selected based on the sub-ranges within which the current SOC falls. The results, therefore, provided multistage decision-making guidance for prosumers with energy storage.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Evaluating the Suitability for CO 2 Storage at the FutureGen 2.0 Site, Morgan County, Illinois, USA

FutureGen 2.0 site will be the first near-zero emission power plant with fully integrated long-term storage in a deep, non-potable saline aquifer in the United States. The proposed FutureGen 2.0 CO 2 storage site is located in northeast Morgan County, Illinois, U.S.A., forty-eight kilometres from the Meredosia Energy Center where a large-scale oxy-combustion demonstration will be conducted. The demonstration will involve > 90% carbon capture, which will produce more than one million metric tons (MMT) of CO 2 per year. The CO 2 will be compressed at the power plant and transported via pipeline to the storage site. To examine CO 2 storage potential of the site, a 1,467m characterization well (FGA#1) was completed in December 2011. The target reservoir for CO 2 storage is the Mt. Simon Sandstone and Elmhurst Sandstone Member of the lower Eau Claire Formation for a combined thickness of 176 m. Confining beds of the overlying Lombard and Proviso Members (upper Eau Claire Formation) reach a thickness of 126 m. Characterization of the target injection zone and the overlying confining zone was based on wellbore data, cores, and geophysical logs, along with surface geophysical (2-D seismic profiles, magnetic and gravity), and structural data collected during the initial stage of the project . Based on this geological model, 3D simulations of CO 2 injection and redistribution were conducted using STOMP-CO 2 , a multiphase flow and transport simulator. After this characterization stage, it appears that the injection site is a suitable geologic system for CO 2 sequestration and that the injection zone is sufficient to receive up to 33 MMT of CO 2 at a rate of 1.1 MMT/yr. GHGT-11 conference

54 ENVIRONMENTAL SCIENCES↗

Which Reservoir for Low Cost Capture, Transportation, and Storage?

Quality and location of a carbon dioxide (CO 2 ) storage reservoir are critical for low cost carbon capture and storage (CCS). This analysis models the combination of capture, transportation, and storage costs to estimate a total cost of CCS. Cost of capture at the source is available for annual rates between 4.1 and 0.7 million tonnes of CO 2 . Cost of transportation is modeled for the distance between the source and the storage reservoir. Cost of CO 2 storage is modeled for four representative reservoirs, two Rose Run and two Mt Simon reservoirs, each reservoir in a dome or regional dip structural setting.

03 NATURAL GAS↗

Design and optimization of flexible decoupled high-temperature gas-cooled reactor plants with thermal energy storage

Advanced nuclear power plants are well-positioned for future zero-carbon grids, however, the need for flexible power generation will be required over the traditional emphasis on baseload generation for meeting historical demands. To achieve such flexibility, this work examines viable configurations for coupling nuclear energy production with thermal energy storage. Previous designs on nuclear-thermal energy storage configurations for advanced reactor designs, which utilized reactor steam as the heat source for charging the thermal energy storage, are restricted by the heat diversion ratio and efficiency losses, thus their impacts can be limited. In this context, this study proposes configurations for fully decoupling the nuclear reactor from the power cycle and positioning the storage as an intermediate loop, thereby achieving an unconstrained heat diversion ratio and improved efficiency. Compared with a standard high-temperature gas-cooled reactor’s power cycle, steady-state thermodynamic modeling and dispatch optimizations quantify the benefits of a steam reheat cycle within the fully decoupled thermal energy system to separate the plant cycle from the high-pressure primary side. These benefits are further detailed, compatible with required high-temperature and high-pressure conditions, through (1) open-source dynamic transient models that examine the impact of off-design operation on the systems, (2) the investigation of components design and costing and finally (3) sizing and dispatch optimization. The fully-decoupled design achieves a cycle efficiency of 43.1%, an enhancement over the vendor’s standard efficiency of 42.2% (Xe-100 design). Here, the proposed design offers strengthened physical barriers from the nuclear island as well as superior operational flexibility and power boosting. Dispatch optimization and market analysis reveal that thermal energy storage size is highly dependent on the peak patterns of electricity prices and the minimum generation level constraint imposed on the balance of plant. Evaluation of off-design operation demonstrates that the full decoupling design with the suggested fail-safe control mechanisms ensures a minimal impact on reactor parameters, even during rapid power ramping.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Laboratory evaluation of cyclic underground hydrogen storage in the Temblor sandstone of the San Joaquin Basin, California

Underground Hydrogen Storage (UHS) in depleted oil and gas reservoirs could provide a cost-effective solution to balance seasonal fluctuations in renewable energy generation. However, data and knowledge on UHS at subsurface conditions are limited so it is difficult to estimate how effective this type of storage could be. In this study, we perform high pressure experiment to measure the effectiveness of cyclic hydrogen (H 2 ) storage in a specimen of Temblor sandstone retrieved from the San Joaquin Basin of California. Our experiment mimics reservoir pressure conditions to measure H 2 -brine relative permeability and fluid-rock interactions over the course of ten charging and discharging cycles. Initial gas breakthrough occurred at 15 % to 25 % H2 saturation in the specimen with 3 % NaCl brine as the resident fluid. Continuing injecting to 4 pore volumes (PV) of H 2 yielded an asymptotic H 2 saturation of 38 % to 41 %, a level often referred to as the irreducible gas saturation based on two-phase flow. The boundary condition in this study mimics the near wellbore region, which experiences bi-directional H 2 flow. This bi-directional flow led to evaporative drying of the specimen resulting in 94 % H 2 saturation at the end of 10th cycle. This indicates that cyclic flow and evaporative drying can lead to more efficient reservoir storage where a larger fraction of the reservoir porosity is usable to store H 2 . The produced gas stream consisted of H 2 mixed with 8 % to 22 % H 2 O, indicating formation dry-out by evaporation. Meanwhile, produced water chemistry indicated calcite and silicate dissolution, with calcite sourced from fossil fragments. This led to a loss of cementation and weakened the rock sample. Combined, our results indicate dry-out, compaction, increased H 2 saturation, rock weakening, and permeability loss during cyclic UHS. Overall, we anticipate that the combined effects should lead to higher than anticipated UHS storage efficiency per volume of sandstone reservoir rock.

08 HYDROGEN↗

Opportunities for increasing CO 2 storage in deep, saline formations by active reservoir management and treatment of extracted formation water: Case study at the GreenGen IGCC facility, Tianjin, PR China

Carbon capture, utilization and storage (CCUS) seeks beneficial applications for CO 2 recovered from fossil fuel combustion. This study evaluated the potential for removing formation water to create additional storage capacity for CO 2 , while simultaneously treating the produced water for beneficial use. Furthermore, the process would control pressures within the target formation, lessen the risk of caprock failure, and better control the movement of CO 2 within that formation. The project plans to highlight the method of using individual wells to produce formation water prior to injecting CO 2 as an efficient means of managing reservoir pressure. Because the pressure drawdown resulting from pre-injection formation water production will inversely correlate with pressure buildup resulting from CO 2 injection, it can be proactively used to estimate CO 2 storage capacity and to plan well-field operations. The project studied the GreenGen site in Tianjin, China where Huaneng Corporation is capturing CO 2 at a coal fired IGCC power plant. Known as the Tianjin Enhanced Water Recovery (EWR) project, local rock units were evaluated for CO 2 storage potential and produced water treatment options were then developed. Average treatment cost for produced water with a cooling water treatment goal ranged from 2.27 to 2.96 US$/m 3 (recovery 95.25%), and for a boiler water treatment goal ranged from 2.37 to 3.18 US$/m 3 (recovery 92.78%). Importance analysis indicated that water quality parameters and transportation are significant cost factors as the injection-extraction system is managed over time. Our study found that in a broad sense, active reservoir management in the context of CCUS/EWR is technically feasible. In addition, criteria for evaluating suitable vs. unsuitable reservoir properties, reservoir storage (caprock) integrity, a recommended injection/withdrawal strategy and cost estimates for water treatment and reservoir management are proposed.

54 ENVIRONMENTAL SCIENCES↗

Management and dewatering of brines extracted from geologic carbon storage sites

Subsurface pressure management is a significant challenge in geologic CO 2 storage. Elevated pressure generated from the injection of supercritical CO 2 can be managed by the withdrawal of brine from saline formations before or during CO 2 injection; however, management of the extracted brines is non-trivial because they may have high concentrations of dissolved solids and other contaminants. Dewatering a brine can reduce the volume needing disposal; in addition, water separated from the brine can be a source of usable low salinity water. This review will summarize the composition of brines extracted from select domestic geologic CO 2 storage sites, will calculate the minimum of work of dewatering, and will provide a critical review of developed and developing desalination/dewatering technologies that could be applied to brines extracted from saline formations before or during geologic CO 2 storage operations. Herein are also highlighted, when appropriate, the similarities and the differences between dewatering brines produced from oil/gas operations and brines extracted from geologic CO 2 storage. Since a source of steam or natural gas is likely unavailable/unsuitable for dewatering brines extracted during CO 2 storage, the ideal treatment processes should have a high electrical efficiency and, if possible, should be able to take advantage of the inherent elevated temperature of these brines.

42 ENGINEERING↗

A risk-based approach to evaluating the Area of Review and leakage risks at CO 2 storage sites

The U.S. Environmental Protection Agency’s Class VI regulations for underground carbon dioxide (CO 2 ) injection require owners and operators of storage projects to identify (1) an Area of Review (AoR) that represents the region that may be affected by the injection of CO 2 , and (2) leakage risks that might impact the quality of underground sources of drinking water (USDWs). This article describes how such risks can be determined by accounting for the physical and chemical properties of all components of a CO 2 storage site using elements of the National Risk Assessment Partnership Integrated Assessment Model for Carbon Storage (NRAP-IAM-CS). For this work we used practical data from three sites that are part of two CarbonSAFE (Carbon Storage Assurance Facility Enterprise) projects to demonstrate application of the NRAP-IAM-CS toolset to determine project risk areas. NRAP-IAM-CS was used to estimate the project risk area that could represent the AoR and the impact of leakage through legacy wells to overlying drinking waters at these candidate CO 2 storage sites. Our study shows that risk to USDWs is minimal despite (1) the presence of multiple legacy wells at these sites where the AoR approximates the maximum extent of injected CO 2 or (2) the presence of a much larger AoR approximating the pressure front caused by the injection of CO 2 .

54 ENVIRONMENTAL SCIENCES↗

Thermal and solubility effects on fault leakage during geologic carbon storage

Geologic carbon storage (GCS) is a promising method for reducing anthropogenic CO 2 emissions to the atmosphere. To safely deploy GCS in the field, it is necessary to assess risks and the effect of uncertainty on safe storage. The effect of uncertainty can be quantified using batches of simulations, but the high computational costs of high-resolution simulations necessitate use of reduced-order models (ROMs). Previous work involves ROMs for quantifying the risk of different potential leakage paths from storage reservoirs to shallow formations. However, previous studies on development of fault-leakage ROMs have limited numbers of uncertain parameters and do not explicitly examine impacts of CO 2 solubility and thermal stresses on fault reactivation, which can generate high-permeability pathways and compromise CO 2 storage. Here, we analyze an ensemble of simulations considering CO 2 leakage from a storage reservoir to a shallow aquifer through a fault while varying a number of uncertain parameters related to thermo-hydro-mechanical properties and CO 2 injection. We show the effects of solubility on: free-phase CO 2 -leakage rates, brine-leakage rates, and poroelastic fault destabilization. We find that CO 2 solubility is more important for estimating free-phase CO 2 -leakage rates compared to brine-leakage rates or poroelastic fault destabilization. We also find that thermal stresses and overpressures have different spatial distributions within the fault, indicating that the spatial variability of overpressures due to variation in flow parameters does not necessarily make the spatial variability of thermal stresses negligible. We suggest the use of the CO 2 phase-change path as a variable in future fault-leakage ROMs.

03 NATURAL GAS↗

Machine-learning and first-principles investigation of lightweight medium-entropy alloys for hydrogen-storage applications

The transition to a low-carbon economy demands efficient and sustainable energy-storage solutions, with hydrogen emerging as a promising clean-energy carrier and with metal hydrides recognized for their hydrogen-storage capacity. Here, we leverage machine learning (ML) to predict hydrogen-to-metal (H/M) ratios and solution energy by incorporating thermodynamic parameters and local lattice distortion (LLD) as key features. Our best-performing ML model provides improvements to H/M ratios and solution energies over a broad class of medium-entripy alloys (easily extendable to multi-principal-element alloys), such as Ti–Nb-X (X = Mo, Cr, Hf, Ta, V, Zr) and Co–Ni-X (X = Al, Mg, V). Ti–Nb–Mo alloys reveal compositional effects in H-storage behavior, in particular Ti, Nb, and V enhance H-storage capacity, while Mo reduces H/M and hydrogen weight percent by 40–50 %. We attributed results in molybdenum-rich alloys to slow hydrogen kinetics, as validated by our pressure-composition-temperature (PCT) isotherm experiments on pure Ti and Ti 5 Mo 95 alloys. Density functional theory (DFT) and molecular dynamics (MD) simulations also confirm that Ti and Nb promote H diffusion, whereas Mo hinders it, highlighting the interplay between electronic structure, lattice distortions, and hydrogen uptake. Notably, our Gradient Boosting Regression model identifies LLD as a critical factor in H/M predictions. Here, to aid material selection, we present two periodic tables illustrating elemental effects on (a) H 2 wt% and (b) solution energy, derived from ML, and provide a reference for identifying alloying elements that enhance hydrogen solubility and storage.

08 HYDROGEN↗

Coupled thermal-hydrological-mechanical behavior of rock mass surrounding a high-temperature thermal energy storage cavern at shallow depth

The present study is aimed at numerically examining the thermal-hydrological-mechanical (THM) processes within the rock mass surrounding a cavern used for thermal energy storage (TES). We considered a cylindrical rock cavern with a height of 50 m and a radius of 10 m storing thermal energy of 350ºC as a conceptual TES model and simulated its operation for 30 years using THM coupled numerical modeling. At first, the insulator performance was not considered for the purpose of investigating the possible coupled THM behavior of the surrounding rock mass; then, the effects of an insulator were examined for different insulator thicknesses. The key concerns were focused on the hydro-thermal multiphase flow and heat transport in the rock mass around the thermal storage cavern, the effect of evaporation of rock mass, thermal impact on near the ground surface and the mechanical behavior of the surrounding rock mass. It is shown that the rock temperature around the cavern rapidly increased in the early stage and, consequently, evaporation of groundwater occurred, raising the fluid pressure. However, evaporation and multiphase flow did not have a significant effect on the heat transfer and mechanical behavior in spite of the high-temperature (350ºC) heat source. The simulations showed that large-scale heat flow around a cavern was expected to be conductiondominated for a reasonable value of rock mass permeability. Thermal expansion as a result of the heating of the rock mass from the storage cavern led to a ground surface uplift on the order of a few centimeters and to the development of tensile stress above the storage cavern, increasing the potentials for shear and tensile failures after a few years of the operation. Finally, the analysis showed that high tangential stress in proximity of the storage cavern can some shear failure and local damage, although large rock wall failure could likely be controlled with appropriate insulators and reinforcement.

58 GEOSCIENCES↗

Holocene cold storage practices on the eastern Snake River Plain: A risk-mitigation strategy for lean times

Previous archaeological research in southern Idaho has suggested that climate change over the past 8000 years was not dramatic enough to alter long-term subsistence practices in the region. However, recent isotopic analyses of bison remains from cold storage caves on the Snake River Plain contest this hypothesis. Our results, when examined against an archaeoclimate model, suggest that cold storage episodes coincided with drier, warmer phases that likely reduced forage and water, and thus limited the availability of bison on the open steppe. Within this context we build a risk model to illustrate how environment might have motivated cold storage behaviors. Caching bison in cold lava tubes would have mitigated both intra-annual and inter-annual food shortages under these conditions. This analysis also suggests that skeletal fat, more than meat, may have influenced the selection, transport and storage of bison carcass parts. We deciphered when and how cold storage caves which was used to provide a more comprehensive understanding of foraging behaviors in a broad range of hunting-gathering economies.

54 ENVIRONMENTAL SCIENCES↗

Risk assessment of wellbore leakage during underground hydrogen storage

The expansion of renewable energy sources would require large-scale energy storage options to overcome the intermittent nature of these sources. Underground hydrogen storage (UHS) in depleted hydrocarbon reservoirs offers a scalable and practical energy storage solution. These reservoirs are chosen for their availability and large capacity, but the unique properties of hydrogen raise concerns about potential leakage pathways, particularly through wellbores. In this study, we develop and apply, for the first time, reduced-order models (ROMs) specifically designed for efficient leakage risk prediction in UHS systems operating in depleted hydrocarbon reservoirs. Using 3,000 high-fidelity simulation scenarios, we examine the influence of 11 key parameters, including reservoir and aquifer depths, wellbore permeability and porosity, initial saturations of water, oil and gas fractions (hydrogen, light, intermediate, and heavy hydrocarbons), reservoir pressure multiplier, and the aquifer-to-reservoir volume ratio, to simulate leakage behavior over a 1,000-year timescale. We train ROMs using a two-step classification-regression approach, achieving R 2 values exceeding 99 % across all targets. These ROMs effectively capture the leakage evolution and identify critical controls of leakage, guiding the design of mitigation strategies. Results indicate that gas leakage occurs in about 27 % of scenarios as early as five years post-operation, reaching volumes of up to 106 ft3. Oil leakage is less frequent (~17 %) and typically begins decades later. Our findings also show that hydrogen often migrates first, owing to its smaller molecular size and higher buoyancy, followed by heavier hydrocarbons. Over time, these heavier components contribute significantly to the total leaked volume, reinforcing the need for targeted monitoring and remediation strategies. Our analysis highlights that deeper storage reservoirs, shallower aquifers, and low-permeability wellbores significantly reduce leakage risks. In conclusion, this work offers a robust framework for risk-informed UHS deployment, supporting energy security through reliable large-scale hydrogen storage while safeguarding environmental integrity.

08 HYDROGEN↗

Multiscale characterization of phase change materials for building thermal energy storage applications

Phase change materials (PCMs) store and release large amounts of thermal energy because of their high latent energy storage capacity. However, long-term cyclic stability, supercooling and performance-scalability are some of the major challenges for their use in building thermal energy storage (TES) applications. Here, in this study, we present a comprehensive multiscale characterization of two commercially available organic PCMs, Puretemp 18 and Puretemp 23. At the microscale, differential scanning calorimetry (DSC) was used to characterize phase change temperature, specific heat, and latent heat. At the mesoscale, a heat flow meter apparatus (HFMA), following the ASTM C1784 standard, was employed to measure the phase change temperature, specific heat, and latent heat properties. A comparative analysis of latent heat as a function of temperature was conducted by integrating the DSC and HFMA results. At the macroscale, the thermal performance and cyclic stability of the TES system was evaluated using Puretemp 23. The TES system consisted of a finned tube heat exchanger with a storage volume of 0.0189 m 3 (5 gal), which represents a compact, real-world TES solution suitable for building energy storage. The results showed consistent thermal stability of the PCM over 200 cycles, and the supercooling temperature remained within 0.2 °C, which was not detected in smaller-scale characterization methods. Additionally, the macroscale testing methodology of the PCM revealed that the TES is able to charge and discharge stored latent energy within 2 h under a temperature differential of 16.67 °C measured between the inlet water temperature and the phase transition temperature of the PCM. The proposed multiscale PCM characterization method provides a systematic basis for comparing important thermal storage properties while also investigating the scalability, reliability and integration challenges in large scale TES applications.

Latent heat↗

Energy transfer for storage or recovery in capacitive deionization using a DC-DC converter

Energy recovery from capacitive deionization (CDI) has the potential to increase overall desalination efficiency. We here define the storage (one-way) and utilization (round-trip) efficiencies between a CDI cell and an energy storage device using a generic direct current/direct current (DC/DC) converter circuit. Presented is a closed-form analytical model for the case of a supercapacitor (SC) as the energy storage device and a buck-boost converter as the DC/DC converter. The model is benchmarked with a numerical model, showing good agreement. Also presented is a comparison among energy transfer methods wherein desalination productivity is fixed. For constant current operation, this condition requires higher currents to compensate for the inactive time introduced by the converter. For fixed productivity, the mean current of the converter circuit approaches the constant current value for higher initial voltages and lower capacitances in the supercapacitor. Finally, we show the effect of relevant parameters of the SC in the storage and utilization efficiency. The model predicts storage and utilization efficiencies of at least 90% for an initial voltage of 1 V or higher and reasonable CDI and SC parameters. Finally, we provide engineering operational parameters to maximize the efficiency of energy transfer and guidance in the selection of electronic components.

25 ENERGY STORAGE↗

First-principles study of hydrogen storage on Ti-decorated B{sub 2}C sheet

The hydrogen storage capacity of Ti decorated B{sub 2}C sheet has been investigated by first-principles plane-wave calculation. It is revealed that a single Ti atom adsorbed on the B{sub 2}C sheet can strongly bind up to four hydrogen molecules. The adsorption energy is in the range of -0.36--0.82 eV/H{sub 2}, which is suitable for ambient temperature hydrogen storage. Considering the fact that Ti can be loaded on both sides of B{sub 2}C sheet, corresponding gravimetric storage capacity of Ti/B{sub 2}C system was also calculated and it can reach to about 7.0 wt%, exceeding the minimum requirement of 6.0 wt% for applications. - Graphical abstract: We investigated the hydrogen storage capacity of Ti decorated B{sub 2}C sheet. The most favorable adsorption geometries for every number of hydrogen molecules on Ti/B{sub 2}C complex are given in the figure. Highlights: Black-Right-Pointing-Pointer Ti decorated B{sub 2}C sheet serve as hydrogen storage medium. Black-Right-Pointing-Pointer A single Ti atom adsorbed on the B{sub 2}C sheet can strongly bind up to four hydrogen molecules. Black-Right-Pointing-Pointer The adsorption energy is in moderate range of -0.36--0.82 eV/H{sub 2}.

36 MATERIALS SCIENCE↗

Effect of p-type multi-walled carbon nanotubes for improving hydrogen storage behaviors

In this study, the hydrogen storage behaviors of p-type multi-walled carbon nanotubes (MWNTs) were investigated through the surface modification of MWNTs by immersing them in sulfuric acid (H{sub 2}SO{sub 4}) and hydrogen peroxide (H{sub 2}O{sub 2}) at various ratios. The presence of acceptor-functional groups on the p-type MWNT surfaces was confirmed by X-ray photoelectron spectroscopy. Measurement of the zeta-potential determined the surface charge transfer and dispersion of the p-type MWMTs, and the hydrogen storage capacity was evaluated at 77 K and 1 bar. From the results obtained, it was found that acceptor-functional groups were introduced onto the MWNT surfaces, and the dispersion of MWNTs could be improved depending on the acid-mixed treatment conditions. The hydrogen storage was increased by acid-mixed treatments of up to 0.36 wt% in the p-type MWNTs, compared with 0.18 wt% in the As-received MWNTs. Consequently, the hydrogen storage capacities were greatly influenced by the acceptor-functional groups of p-type MWNT surfaces, resulting in increased electron acceptor–donor interaction at the interfaces. - Graphical abstract: Hydrogen storage behaviors of the p-type MWNTs with the acid-mixed treatments are described. Display Omitted Display Omitted.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Hydrogen trapping and storage in the group IVB-VIB transition metal carbides

The transition metal carbides have been known to act as traps for hydrogen in steels as well as potential materials for hydrogen storage. Despite numerous experimental and a few theoretical studies, what impacts hydrogen trapping and storage in the transition metal carbides is not well understood. In this work, we use density functional theory to systematically investigate the bulk trapping and storage capabilities of the transition metal carbides. We specifically examine how trapping and storage changes with the transition metal, from the group IVB to group VIB, carbon concentration, and structure. Our results demonstrate a strong correlation between the trap energy and the number of valence electrons in the transition metal, suggesting that the group IVB transition metal carbides are the best carbides for trapping and storage. Hydrogen preferentially sits at octahedral interstices, e.g., the carbon vacancies, in the structure except in certain cases near the Me 2 C concentration when tetrahedral interstices, devoid of nearest neighbor carbon, can become more favorable. Our results further demonstrate that the lower the carbon concentration, the more hydrogen the transition metal carbide can store. These results demonstrate which carbides will act as the best traps for hydrogen.

08 HYDROGEN↗