Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “software estimations”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,387 records · Page 77

Technical Advances for Sustainable Remediation: In Situ Monitoring and Climate Resiliency - 18436

Recent advances in sustainable remediation techniques show promise as solutions for contaminant removal in soil and groundwater media. Although passive remediation (or natural attenuation) has gained momentum as an acceptable technique, there are still challenges in regulatory frameworks as well as in public acceptance. Leaving contaminants in subsurface requires increased burden of proof to show that plumes are stable and residual contaminants do not pose a significant health risk. Climate changes and frequent extreme climate events contribute another level of complexity and make it difficult to demonstrate system stability and predict future plume conditions. In this study, we show two coupled approaches to tackle this challenge: (1) in situ groundwater monitoring based on advanced sensor and data analytics technologies (i.e., Big Data), and (2) state-of-art modeling for optimizing monitoring and site closure strategies. In the new monitoring approach, in situ sensors are used to continuously measure the key variables that control contaminant plume mobility and its spatial and temporal distribution (such as pH, redox potential, electrical conductivity, and groundwater level). Coupled with a limited number of groundwater sampling, the data analytics methods - data mining and machine learning - allow us to estimate contaminant concentrations, and also to detect any significant changes associated with the plume mobility. In parallel, the state-of-art numerical flow and reactive transport model - ASCEM software under DOE Office of Environmental Management - provides a physical and mechanistic understanding of the system behavior, and predicts the long-term plume migration for optimizing the monitoring and closure strategies. In particular, we focus on the effects of extreme precipitation or drought on the site closure as well as monitoring strategies. We demonstrate this approach at the Savannah River Site (SRS) F-Area, where groundwater is contaminated by various radionuclides, including uranium, tritium and technetium. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Recent SEL experiments and studies

The studies discussed in this paper are all examples of activities that are performed as part of the Software Engineering Laboratory's (SEL's) process improvement model. Using this model, the SEL starts by understanding the product and process, then assesses the impact of new technologies, and finally packages what was learned. The preliminary examination of maintenance effort, error, and change profiles to establish a maintenance baseline exemplifies understanding-phase activities. The ongoing testing study that is examining the effects of various testing approaches on process and product measures is an example of typical assessing efforts. Finally, the derivation of cost and schedule estimation models from locally driven factors such as reuse level, application type, and language is an example of experience packaging. In the SEL, no study is ever really completed. Studies will be repeated and iterated upon in the future as part of the ongoing software improvement process.

Pajerski, Rose↗

Implementation of Pin Point Landing Vision Components in an FPGA System

Pin-point landing is required to enable missions to land close, typically within 10 meters, to scientifically important targets in generally hazardous terrain. In Pin Point Landing both high accuracy and high speed estimation of position and orientation is needed to provide input to the control system to safely choose and navigate to a safe landing site. A proposed algorithm called VISion aided Inertial NAVigation (VISINAV) has shown that the accuracy requirements can be met. [2][3] VISINAV was shown in software only, and was expected to use FPGA enhancements in the future to improve the computational speed needed for pin point landing during Entry Descent and Landing (EDL). Homography, feature detection and spatial correlation are computationally intensive parts of VISINAV. Homography aligns the map image with the descent image so that small correlation windows can be used, and feature detection provides regions that spatial correlation can track from frame to frame in order to estimate vehicle motion. On MER the image Homography, Feature Detection and Correlation would take approximately 650ms tracking 75 features between frames. We implemented Homography, Feature detection and Correlation on a Virtex 4 LX160 FPGA to run in under 25ms while tracking 500 features to improve algorithm reliability and throughput.

aircraft landing guidance↗

Calculating Dose Release Factors to Obtain the Worst-Case Maximally Exposed Location by Sector

The aim of this project was to update the SRS Dose Release Factors (DRF's) for the Maximally Exposed Individual (MEI) for 20 area release points onsite. To update, potential MEIs now include onsite locations and modeled stack heights were updated to match onsite operations. The DRF's and MEI locations are used to ensure DOE and EPA compliance is met for dose standards. The Environmental Protection Agency (EPA) requires the use of the computer model CAP88 to estimate doses for demonstrating compliance with 40 CFR 61, the National Emission Standard for Hazardous Air Pollutants (NESHAP). The location of the maximally exposed individual (MEI) by sector and distance is required for execution of CAP88. The worst-case sector is the sector and distance where an offsite individual would receive the highest dose due to a potential release from a designated release location at a facility. The worst-case sector analysis addresses potential ground-level and stack-height releases from 20 areas of Savannah River Site (SRS). Weather patterns were analyzed at each of these areas relative to sixteen compass points. The analysis makes use of recently updated distance data and meteorological data. The computer model, CAP88 is EPA's software system used by the Department of Energy (DOE) to calculate the receptor dose due to routine atmospheric releases via a gaussian plume at the Savannah River Site (SRS). The dose-release factors (DRFs) are used to estimate the offsite and onsite dose from facility-specific releases and represent the dose to a receptor exposed to 1 Ci of a specified radionuclide being released into the atmosphere. The DRFs are simply a ratio of the TED to the release rate and, therefore, are directly scalable. The DRF values listed in the Appendix can be applied to expected release values from each area to estimate the potential dose to an individual adult at each location. NESHAP DRFs have been supplied to Environmental Compliance and Area Closure Projects (EC and ACP) for many years and are periodically updated to include changes in Cap88. estimate the potential dose to an individual adult at each location DRF in mrem Ci{sup -1} are estimated by modeling the total effective dose (TED) in mrem yr{sup -1} assuming an annual atmospheric release rate of 1 Ci yr-1 of the associated radionuclides. TED = Effective Dose (ED) + Committed Effective Dose (CED). TED = DRF/RR. Approach and Methods: Determine possible MEI locations Onsite/Offsite including buildings and farms; Determine the distances from the release area to the possible MEI location and the direction from the release to the MEI location; Using the most recent meteorological data (2007-2011) and parameters, run CAP88 for each release area for each compass sector and previously calculated distances to MEI locations using a 1 Ci release rate for tritium; Use the calculated the air concentration values to determine the MEI for each sector from CAP88. The relationship between air concentration and received dose is directly proportional and can be used to determine which locations to calculate DRF's and a dose for an MEI; The DRFs are found for each compass sector from 20 SRS release areas using CAP88-PC Version 4.0; Each location is calculated with ground level releases evaluated for each area for a list of radionuclides, some with and some without progenies; Compare the DRFs of the potential onsite MEIs to offsite MEIs. Based on the 2018 MEI Report, the Site worst case sector MEI is located 593 mW of B-Area. This MEI location represents a point along the main road that travels through a tract of land leased to the SC National Guard. While this location is estimated to have the highest exposure, minimal radioactivity is released from B-Area. In 2017, SRS requested and was approved by the EPA to change the location for modeling site releases from the Center of Site to H-Area, and to use six stack heights. H-Area emission account for approximately 90% of all radioactive operations onsite. The MEI for H-Area was found to be 11,458 m NNE which locates the Savannah River Ecology Lab Conference Center. Comparisons for 2018 data and 2014 shows the new methods of calculation are more conservative yet still remain well below the DOE 100 mrem limit.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Software for continuum modeling of controls-structures interactions

It is clear that computer software is needed to assist in the generation of the equations of motion for complex, flexible spacecraft. Daniel Poelaert of ESTEC has developed the software DISTEL with which he has modeled the structural dynamics for different satellites. He is interested in expanding the capabilities of DISTEL to include structural damping and control systems. Unfortunately, the software has not been released. The author has developed similar software, PDEMOD, which has been used to model the Spacecraft control Laboratory Experiment (SCOLE), the Solar Array Flight Experiment (SAFE), the Mini-MAST truss, and the LACE satellite. PDEMOD has been used also for optimal parameter estimation and integrated control-structures design. PDEMOD is also being extended to include structural damping and control systems which are imbedded into the same equations for the structural dynamics. This paper will address the formulation of the equations for the structural dynamics of spacecraft structures which are constructed of a 3-dimensional arrangement of rigid bodies and flexible beam elements. Control system dynamics are imbedded into the same equations so that model order reduction approximations are not necessary. The input data consists of the physical data of the elements and the topological information describing how the elements are connected. PDEMOD accomplishes the following: (1) automatically assembles the equations of motion for the entire structural model; (2) calculates the modal frequencies; (3) calculates the mode shapes; (4) generates perspective views of the mode shapes; and (5) forms selected transfer functions. The software PDEMOD continues to be developed to provide additional features to assist in analyzing and synthesizing control and structural systems for flexible spacecraft.

Taylor, Lawrence W., Jr.↗

Multi Model Monte Carlo with Python (MXMCPy)

Multi Model Monte Carlo with Python (\mxmc {}) is a software package developed as a general capability for computing the statistics of outputs from an expensive, high-fidelity model by leveraging faster, low-fidelity models for speedup. Motivated by uncertainty propagation problems where classical Monte Carlo (MC) simulation is computationally intractable, various multi-model MC approaches have recently emerged that yield unbiased estimators with significantly reduced variance relative to MC for the same cost. These existing methods include multi-level Monte Carlo (MLMC), multi-fidelity Monte Carlo (MFMC), and approximate control variates (ACV). Given a fixed computational budget and a collection of models with varying cost/accuracy, each method seeks a sample allocation strategy across the models that results in an estimator with optimal variance reduction. \mxmc {} is a versatile tool that enables convenient access to many existing multi-model MC approaches within one modular and extensible package. With \mxmc {}, users can easily compare existing methods to determine the best choice for their particular problem, while developers have a basis for implementing and sharing new variance reduction approaches. This report introduces the \mxmc {} software, providing a summary of the problem-solving workflow for users as well as a brief overview of the code layout for developers.

Geoffrey F Bomarito↗

Regional heritability advanced complex trait analysis for GPU and traditional parallel architectures

Motivation: Quantification of the contribution of genetic variation to phenotypic variation for complex traits becomes increasingly computationally demanding with increasing numbers of single-nucleotide polymorphisms and individuals. To meet the challenges in making feasible large-scale studies, we present the REgional heritability advanced complex trait analysis software. Adapted from advanced complex trait analysis (and, in turn, genome-wide complex trait analysis), it is tailored to exploit the parallelism present in modern traditional and graphics processing unit (GPU)-accelerated machines, from workstations to supercomputers. Results: We adapt the genetic relationship matrix estimation algorithm to remove limitations on memory, allowing the analysis of large datasets. Further, we build on this to develop a version of the code able to efficiently exploit GPU-accelerated systems for both the genetic relationship matrix and REstricted maximum likelihood (REML) parts of the analysis, offering substantial speedup over the traditional central processing unit version. We develop the ability to analyze multiple small regions of the genome across multiple compute nodes in parallel, following the ‘regional heritability’ approach. We demonstrate the new software using 1024 GPUs in parallel on one of the world’s fastest supercomputers. Availability: The code is freely available at http://www.epcc.ed.ac.uk/software-products

59 BASIC BIOLOGICAL SCIENCES↗

NASA Tech Briefs, March 2010

Topics covered include: Software Tool Integrating Data Flow Diagrams and Petri Nets; Adaptive Nulling for Interferometric Detection of Planets; Reducing the Volume of NASA Earth-Science Data; Reception of Multiple Telemetry Signals via One Dish Antenna; Space-Qualified Traveling-Wave Tube; Smart Power Supply for Battery-Powered Systems; Parallel Processing of Broad-Band PPM Signals; Inexpensive Implementation of Many Strain Gauges; Constant-Differential-Pressure Two-Fluid Accumulator; Inflatable Tubular Structures Rigidized with Foams; Power Generator with Thermo-Differential Modules; Mechanical Extraction of Power From Ocean Currents and Tides; Nitrous Oxide/Paraffin Hybrid Rocket Engines; Optimized Li-Ion Electrolytes Containing Fluorinated Ester Co-Solvents; Probabilistic Multi-Factor Interaction Model for Complex Material Behavior; Foldable Instrumented Bits for Ultrasonic/Sonic Penetrators; Compact Rare Earth Emitter Hollow Cathode; High-Precision Shape Control of In-Space Deployable Large Membrane/Thin-Shell Reflectors; Rapid Active Sampling Package; Miniature Lightweight Ion Pump; Cryogenic Transport of High-Pressure-System Recharge Gas; Water-Vapor Raman Lidar System Reaches Higher Altitude; Compact Ku-Band T/R Module for High-Resolution Radar Imaging of Cold Land Processes; Wide-Field-of-View, High-Resolution, Stereoscopic Imager; Electrical Capacitance Volume Tomography with High-Contrast Dielectrics; Wavefront Control and Image Restoration with Less Computing; Polarization Imaging Apparatus; Stereoscopic Machine-Vision System Using Projected Circles; Metal Vapor Arcing Risk Assessment Tool; Performance Bounds on Two Concatenated, Interleaved Codes; Parameterizing Coefficients of a POD-Based Dynamical System; Confidence-Based Feature Acquisition; Algorithm for Lossless Compression of Calibrated Hyperspectral Imagery; Universal Decoder for PPM of any Order; Algorithm for Stabilizing a POD-Based Dynamical System; Mission Reliability Estimation for Repairable Robot Teams; Processing AIRS Scientific Data Through Level 3; Web-Based Requesting and Scheduling Use of Facilities; AutoGen Version 5.0; Time-Tag Generation Script; PPM Receiver Implemented in Software; Tropospheric Emission Spectrometer Product File Readers; Reporting Differences Between Spacecraft Sequence Files; Coordinating "Execute" Data for ISS and Space Shuttle; Database for Safety-Oriented Tracking of Chemicals; Apparatus for Cold, Pressurized Biogeochemical Experiments; Growing B Lymphocytes in a Three-Dimensional Culture System; Tissue-like 3D Assemblies of Human Broncho-Epithelial Cells; Isolation of Resistance-Bearing Microorganisms; Oscillating Cell Culture Bioreactor; and Liquid Cooling/Warming Garment.

Source record↗

SU-E-J-92: Validating Dose Uncertainty Estimates Produced by AUTODIRECT, An Automated Program to Evaluate Deformable Image Registration Accuracy

Purpose: Deformable image registration (DIR) is a powerful tool with the potential to deformably map dose from one computed-tomography (CT) image to another. Errors in the DIR, however, will produce errors in the transferred dose distribution. We have proposed a software tool, called AUTODIRECT (automated DIR evaluation of confidence tool), which predicts voxel-specific dose mapping errors on a patient-by-patient basis. This work validates the effectiveness of AUTODIRECT to predict dose mapping errors with virtual and physical phantom datasets. Methods: AUTODIRECT requires 4 inputs: moving and fixed CT images and two noise scans of a water phantom (for noise characterization). Then, AUTODIRECT uses algorithms to generate test deformations and applies them to the moving and fixed images (along with processing) to digitally create sets of test images, with known ground-truth deformations that are similar to the actual one. The clinical DIR algorithm is then applied to these test image sets (currently 4) . From these tests, AUTODIRECT generates spatial and dose uncertainty estimates for each image voxel based on a Student’s t distribution. This work compares these uncertainty estimates to the actual errors made by the Velocity Deformable Multi Pass algorithm on 11 virtual and 1 physical phantom datasets. Results: For 11 of the 12 tests, the predicted dose error distributions from AUTODIRECT are well matched to the actual error distributions within 1–6% for 10 virtual phantoms, and 9% for the physical phantom. For one of the cases though, the predictions underestimated the errors in the tail of the distribution. Conclusion: Overall, the AUTODIRECT algorithm performed well on the 12 phantom cases for Velocity and was shown to generate accurate estimates of dose warping uncertainty. AUTODIRECT is able to automatically generate patient-, organ- , and voxel-specific DIR uncertainty estimates. This ability would be useful for patient-specific DIR quality assurance.

60 APPLIED LIFE SCIENCES↗

Engineering a modular 44 Ti/ 44 Sc generator: eluate evaluation in preclinical models and estimation of human radiation dosimetry

Background: 44 Sc/ 47 Sc is an attractive theranostic pair for targeted in vivo positron emission tomographic (PET) imaging and beta-particle treatment of cancer. The 44 Ti/ 44 Sc generator allows daily onsite production of this diagnostic isotope, which may provide an attractive alternative for PET facilities that lack in-house irradiation capabilities. Early animal and patient studies have demonstrated the utility of 44 Sc. In our current study, we built and evaluated a novel clinical-scale 44 Ti/ 44 Sc generator, explored the pharmacokinetic profiles of 44 ScCl 3 , [ 44 Sc]-citrate and [ 44 Sc]-NODAGA (1,4,7-triazacyclononane,1-glutaric acid-4,7-acetic acid) in naïve mice, and estimated the radiation burden of 44 ScCl 3 in humans. Methods: 44 Ti/ 44 Sc (101.2 MBq) in 6 M HCl solution was utilized to assemble a modular ZR resin containing generator. After assembly, 44 Sc was eluted with 0.05 M HCl for further PET imaging and biodistribution studies in female Swiss Webster mice. Based on the biodistribution data, absorbed doses of 44 / 47 ScCl 3 in human adults were calculated for 18 organs and tissues using the IDAC-Dose software. Results: 44 Ti in 6 M HCl was loaded onto the organic resin generator with a yield of 99.97%. After loading and initial stabilization, 44 ScCl 3 was eluted with 0.05 M HCl in typical yields of 82.9 ± 5.3% (N = 16), which was normalized to the estimated generator capacity. Estimated generator capacity was computed based on elution time interval and the total amount of 44 Ti loaded on the generator. Run in forward and reverse directions, the 44 Sc/ 44 Ti ratio from a primary column was significantly improved from 1038 ± 440 to 3557 ± 680 (Bq/Bq) when a secondary, replaceable, ZR resin cartridge was employed at the flow outlet. In vivo imaging and ex vivo distribution studies of the reversible modular generator for 44 ScCl 3 , [ 44 Sc]-citrate and [ 44 Sc]-NODAGA show that free 44 Sc remained in the circulation significantly longer than the chelated 44 Sc. The dose estimation of 44 ScCl 3 reveals that the radiation burden is 0.146 mSv/MBq for a 70 kg adult male and 0.179 mSv/MBq for a 57 kg adult female. Liver, spleen and heart wall will receive the highest absorbed dose: 0.524, 0.502, and 0.303 mGy/MBq, respectively, for the adult male. Conclusions: A clinical-scale 44 Ti/ 44 Sc generator system with a modular design was developed to supply 44 ScCl 3 in 0.05 M HCl, which is suitable for further radiolabeling and in vivo use. Our data demonstrated that free 44 ScCl 3 remained in the circulation for extended periods, which resulted in approximately 10 times greater radiation burden than stably chelated 44 Sc. Stable 44 Sc/ 47 Sc-complexation will be more favorable for in vivo use and for clinical utility.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Recalibrating software reliability models

In spite of much research effort, there is no universally applicable software reliability growth model which can be trusted to give accurate predictions of reliability in all circumstances. Further, it is not even possible to decide a priori which of the many models is most suitable in a particular context. In an attempt to resolve this problem, techniques were developed whereby, for each program, the accuracy of various models can be analyzed. A user is thus enabled to select that model which is giving the most accurate reliability predictions for the particular program under examination. One of these ways of analyzing predictive accuracy, called the u-plot, in fact allows a user to estimate the relationship between the predicted reliability and the true reliability. It is shown how this can be used to improve reliability predictions in a completely general way by a process of recalibration. Simulation results show that the technique gives improved reliability predictions in a large proportion of cases. However, a user does not need to trust the efficacy of recalibration, since the new reliability estimates produced by the technique are truly predictive and so their accuracy in a particular application can be judged using the earlier methods. The generality of this approach would therefore suggest that it be applied as a matter of course whenever a software reliability model is used.

Brocklehurst, Sarah↗

Recalibrating software reliability models

In spite of much research effort, there is no universally applicable software reliability growth model which can be trusted to give accurate predictions of reliability in all circumstances. Further, it is not even possible to decide a priori which of the many models is most suitable in a particular context. In an attempt to resolve this problem, techniques were developed whereby, for each program, the accuracy of various models can be analyzed. A user is thus enabled to select that model which is giving the most accurate reliability predicitons for the particular program under examination. One of these ways of analyzing predictive accuracy, called the u-plot, in fact allows a user to estimate the relationship between the predicted reliability and the true reliability. It is shown how this can be used to improve reliability predictions in a completely general way by a process of recalibration. Simulation results show that the technique gives improved reliability predictions in a large proportion of cases. However, a user does not need to trust the efficacy of recalibration, since the new reliability estimates prodcued by the technique are truly predictive and so their accuracy in a particular application can be judged using the earlier methods. The generality of this approach would therefore suggest that it be applied as a matter of course whenever a software reliability model is used.

Brocklehurst, Sarah↗

Dynamic Assurance of Autonomous Systems through Ground Control Software

Assurance cases are being increasingly acknowledged as a way to build trust in complex systems with autonomous capabilities [1]. An assurance case is a comprehensive, defensible, and valid justification that a system will function as intended for the specific mission and operating environment. Such justifications for systems with autonomous capabilities are often based on various probabilistic quantifications [2]. Due to the dynamic nature of the environmental conditions in which these systems operate, as well as the changing nature of the autonomous systems themselves, these probabilistic quantifications cannot be simply estimated once during design time. Rather, they need to be continually evaluated during systems operations to ensure that the assurance case justifications are valid. We refer to the assurance case that combines both the static and dynamic elements as a Dynamic Assurance Case (DAC). Such complex systems with autonomous capabilities are often deployed with a Ground Control Software (GCS) component to enable remote operation. Whether the system is composed of a single unit or a fleet of units, deployed distributed or in remote environments, GCS acts as a window into the behavior of the deployed system. It receives telemetry from the system, issues commands to the system and provides various functionalities to visualize the system performance. We propose a dynamic assurance framework where the GCS acts as a relay between the autonomous system and its DAC. GCS can be used to measure both unit-specific as well as system-wide probabilistic quantifications using the incoming telemetry. We embed these quantifications throughout the DAC as variables that can be updated by external sources. We use the GCS to periodically update these variables, which allows us to continually evaluate the formally defined assurance case justifications. We demonstrate our dynamic assurance framework in the NASA Ames project Troupe1 that aims at developing a fleet of rovers capable of au- tonomously mapping their environment. The rovers work cooperatively, each collecting data for different parts of the environment. Each rover runs an identical core Flight System (cFS) [4] application. Troupe1 uses OpenC3 Cosmos [5] as the ground system, and AdvoCATE [3] to capture the system DAC. We show how we can measure both rover-specific and system-wide quantifications in Cosmos using its Ruby scripting editor and pass them into the DAC modelled in AdvoCATE. Then, we show how these incoming variables can be embedded in different parts of the DAC and how effects of their updates can be observed

Irfan Sljivo↗

Integrated In-Situ Resource Utilization Modeling of a Lunar Water Processing System

A key element of achieving a sustained surface presence, such as defined in NASA’s Artemis plan, is In-Situ Resource Utilization (ISRU). ISRU is the practice of using local resources to provide mission consumables that reduce system launch mass requirements, and regenerate resources (chiefly, water and oxygen) for propulsion and life support supporting both Lunar and Martian missions. ISRU systems require multiple complex processes, such as excavation, chemical reactors, and electrolysis subsystems that must operate in harmony to optimize the overall system process from beginning to end. The Mission Analysis and Integration Tool (MAIT) connects individual subsystem models into a customized, flexible framework for the purpose of technology downselect, optimization, and end-to-end process planning. MATLAB was favorable to use as the main software integration tool due to its ability to communicate with a vast number of other programming languages and makes up the backbone of data flow between inputs and outputs to the subsystem models. MAIT initially evaluated a suite of technologies, including but not limited to, the water processing Lunar Auger Dryer for ISRU (LADI) system and an oxygen extraction carbothermal reduction process. With individual models consolidated, the MAIT tool generated over 60,000 cases during its parametric sweeps; these system iterations produced valuable insight into the optimal LADI geometry for minimizing heater energy demands, estimating carbothermal reactor and radiator mass relationships, and calculated the power dynamics of the electrolysis unit. Efforts to update the MAIT tool are ongoing to accommodate and scale ISRU technologies supporting the Space Technology Mission Directorate’s (STMD) commercialization strategy, and increase the MAIT software capability to handle a wide array of ISRU system models beyond the Lunar environment, e.g. production of propellant for a Martian lander.

Avery Carlson↗

SU-C-201-06: Utility of Quantitative 3D SPECT/CT Imaging in Patient Specific Internal Dosimetry of 153-Samarium with GATE Monte Carlo Package

Purpose: Patient-specific 3-dimensional (3D) internal dosimetry in targeted radionuclide therapy is essential for efficient treatment. Two major steps to achieve reliable results are: 1) generating quantitative 3D images of radionuclide distribution and attenuation coefficients and 2) using a reliable method for dose calculation based on activity and attenuation map. In this research, internal dosimetry for 153-Samarium (153-Sm) was done by SPECT-CT images coupled GATE Monte Carlo package for internal dosimetry. Methods: A 50 years old woman with bone metastases from breast cancer was prescribed 153-Sm treatment (Gamma: 103keV and beta: 0.81MeV). A SPECT/CT scan was performed with the Siemens Simbia-T scanner. SPECT and CT images were registered using default registration software. SPECT quantification was achieved by compensating for all image degrading factors including body attenuation, Compton scattering and collimator-detector response (CDR). Triple energy window method was used to estimate and eliminate the scattered photons. Iterative ordered-subsets expectation maximization (OSEM) with correction for attenuation and distance-dependent CDR was used for image reconstruction. Bilinear energy mapping is used to convert Hounsfield units in CT image to attenuation map. Organ borders were defined by the itk-SNAP toolkit segmentation on CT image. GATE was then used for internal dose calculation. The Specific Absorbed Fractions (SAFs) and S-values were reported as MIRD schema. Results: The results showed that the largest SAFs and S-values are in osseous organs as expected. S-value for lung is the highest after spine that can be important in 153-Sm therapy. Conclusion: We presented the utility of SPECT-CT images and Monte Carlo for patient-specific dosimetry as a reliable and accurate method. It has several advantages over template-based methods or simplified dose estimation methods. With advent of high speed computers, Monte Carlo can be used for treatment planning on a day to day basis.

60 APPLIED LIFE SCIENCES↗

Fully iterative scatter corrected digital breast tomosynthesis using GPU-based fast Monte Carlo simulation and composition ratio update

Purpose: In digital breast tomosynthesis (DBT), scatter correction is highly desirable, as it improves image quality at low doses. Because the DBT detector panel is typically stationary during the source rotation, antiscatter grids are not generally compatible with DBT; thus, a software-based scatter correction is required. This work proposes a fully iterative scatter correction method that uses a novel fast Monte Carlo simulation (MCS) with a tissue-composition ratio estimation technique for DBT imaging. Methods: To apply MCS to scatter estimation, the material composition in each voxel should be known. To overcome the lack of prior accurate knowledge of tissue composition for DBT, a tissue-composition ratio is estimated based on the observation that the breast tissues are principally composed of adipose and glandular tissues. Using this approximation, the composition ratio can be estimated from the reconstructed attenuation coefficients, and the scatter distribution can then be estimated by MCS using the composition ratio. The scatter estimation and image reconstruction procedures can be performed iteratively until an acceptable accuracy is achieved. For practical use, (i) the authors have implemented a fast MCS using a graphics processing unit (GPU), (ii) the MCS is simplified to transport only x-rays in the energy range of 10–50 keV, modeling Rayleigh and Compton scattering and the photoelectric effect using the tissue-composition ratio of adipose and glandular tissues, and (iii) downsampling is used because the scatter distribution varies rather smoothly. Results: The authors have demonstrated that the proposed method can accurately estimate the scatter distribution, and that the contrast-to-noise ratio of the final reconstructed image is significantly improved. The authors validated the performance of the MCS by changing the tissue thickness, composition ratio, and x-ray energy. The authors confirmed that the tissue-composition ratio estimation was quite accurate under a variety of conditions. Our GPU-based fast MCS implementation took approximately 3 s to generate each angular projection for a 6 cm thick breast, which is believed to make this process acceptable for clinical applications. In addition, the clinical preferences of three radiologists were evaluated; the preference for the proposed method compared to the preference for the convolution-based method was statistically meaningful (p < 0.05, McNemar test). Conclusions: The proposed fully iterative scatter correction method and the GPU-based fast MCS using tissue-composition ratio estimation successfully improved the image quality within a reasonable computational time, which may potentially increase the clinical utility of DBT.

60 APPLIED LIFE SCIENCES↗

TRIPLICATE SODIUM IODIDE GAMMA RAY MONITORS FOR THE SMALL COLUMN ION EXCHANGE PROGRAM

This technical report contains recommendations from the Analytical Development (AD) organization of the Savannah River National Laboratory (SRNL) for a system of triplicate Sodium Iodide (NaI) detectors to be used to monitor Cesium-137 ({sup 137}Cs) content of the Decontaminated Salt Solution (DSS) output of the Small Column Ion Exchange (SCIX) process. These detectors need to be gain stabilized with respect to temperature shifts since they will be installed on top of Tank 41 at the Savannah River Site (SRS). This will be accomplished using NaI crystals doped with the alpha-emitting isotope, Americium-241({sup 241}Am). Two energy regions of the detector output will be monitored using single-channel analyzers (SCAs), the {sup 137}Cs full-energy {gamma}-ray peak and the {sup 241}Am alpha peak. The count rate in the gamma peak region will be proportional to the {sup 137}Cs content in the DSS output. The constant rate of alpha decay in the NaI crystal will be monitored and used as feedback to adjust the high voltage supply to the detector in response to temperature variation. An analysis of theoretical {sup 137}Cs breakthrough curves was used to estimate the gamma activity expected in the DSS output during a single iteration of the process. Count rates arising from the DSS and background sources were predicted using Microshield modeling software. The current plan for shielding the detectors within an enclosure with four-inch thick steel walls should allow the detectors to operate with the sensitivity required to perform these measurements. Calibration, testing, and maintenance requirements for the detector system are outlined as well. The purpose of SCIX is to remove and concentrate high-level radioisotopes from SRS salt waste resulting in two waste streams. The concentrated high-level waste containing {sup 137}Cs will be sent to the Defense Waste Processing Facility (DWPF) for vitrification and the low-level DSS will be sent to the Saltstone Production Facility (SPF) to be incorporated into grout.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Quantifying System Level Impact of Connected and Automated Vehicles in an Urban Corridor

Numerous studies have demonstrated significant energy reduction for an ego vehicle by up to 20% leveraging Vehicle-to-Everything (V2X) technologies [1-4]. Some studies have also analyzed the impact of such vehicles on the energy consumption of other vehicles in a suburban or a highway corridor [5, 6], but the impact in an urban setting has not been studied yet. Southwest Research Institute (SwRI), in collaboration with Continental and Hyundai, is currently working on a Department of Energy funded project that is focused on quantifying the impact of multiple ego vehicles (smart vehicles) on the total energy consumption of the corridor under various traffic conditions, vehicle electrification level, vehicle-to-vehicle (V2V) technology penetration, and the number of smart (ego) vehicles in an urban setting. A six-kilometer-long urban corridor from Columbus, Ohio was modeled and calibrated with real-world data in PTV Vissim traffic microsimulation software. Five forward-looking powertrain models, consisting of two battery electric vehicles (BEVs), a hybrid electric vehicle (HEV), and two internal combustion engine (ICE) powered vehicles, were developed to estimate the energy consumption of vehicles on the corridor. A comprehensive full factorial simulation study was performed. The simulation results indicate that for a traffic mix based on projected new vehicles sales in 2025, a 15% corridor-level energy consumption reduction can be achieved. The paper details the development and validation of the simulation framework, design of experiments conducted, a discussion of challenges faced, and results under various test conditions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗